HomeMy WebLinkAboutAPPROVED Roofing Permit Information Sheet17 l CLL L' L .Q, ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,45.6,7, Metal Roofs A, B, D 1,2,3.4,5,6,7' Wood Shingles and Shakes A, B, D 1,2,4,5,6.7 Other As Applicable 1,2,3,4.5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Campany Roof Maintenance Roofing Division, LC Contractors Name: License tt Job Address 4330 N A1A, Fort Pierce, FL 32949 ROOF CATEGORY Process No. CCC 1330613 ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes X Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) _ Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. u(woTuol;ewllsaleuae•n mm) uoliewlis3 lepay Aq palannod oY a2ed19 = ylgual jadeaed VOt=Ou14se13 dajS t0S=Oul4se13 uoadd :9 Z£= SABIleA 4ZZZ = sdiH IJZZ£ = saopm W91 = sOILH IJI98 = s8ne3 puaBa-I 6 6u!plin9 pa43elap ` u91d 416ua� c •v_ti*i31.L4'.t..,:....Y-.a«:s.i...�.-.. •-. x...i..�..:x,�.,a.... _S:•a..�..�.i<...d?+.t'YS:�:i4•-c...:.,.�i.._.w-as..-.�_....-._-..'.',. .:�_ri.._.,.: .�. ..:.._:—... ,.�-.._....�... __.::_:..-....�._...........-......... ._._......—._...._'__-....,. _"..�... __—_.....—_'-_"_""._.�..___......,....._.___`._--_.._...�........._.......'.'_..-_.._......,......._....._... �_.. ....... ... __..—�- -�.. ... OZOZ 11 T.aaquaanoN'Aepsanl woo•lui�ooiAuedweo@!Iuoo•allaiuep :liew3 0986Z0000� :aaquanN JOPJO 6t76ti£ 33 'a:)aaid Iao3 'VTV AmH N OZBb OSS9-£98-T9S :ud a�ueua�.uie� boob Rueduae� a.�®dsHjo(DojEg:)jj3LULU(D:) :uollewjo u jewolsn :uollemio u luai Client information: Customer Information: Commercial Repo rt ort Campany Roof Maintenance Roof f� I Ph: 561-863-6550 4310 N Hwy AIA, Fort Pierce, FL 34949 order Number:1000029330 Email: danielle.conti@campanyroofing.com Tuesday, November 17, 2020 Property Photos ,411 + i Y -Ir East Side View West Side View 5 Powered by Aerial Estimation (www aerialestimation.coml RERIFiL ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Johns Manville Product Approval No.: FL 16758-RlB Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: -247.5 Deck: Type: Concrete Gauge Thickness: Slope: 0:12 Anchor/Base Sheet & No. df Ply(s): ASTM D41 Anchor/Base Sheet Fastener/Bonding Material: Primer Insulation Base Layer: 1/4" Poly ISO Base Insultation Size and Thickness: 04, 1/4" Base Insulation Fastener/Bonding Material: JM Roof system Urethane Adhesive (RSUA) Top Insulation Layer: 1/2" Nigh Density Wood Fiberboard Top Insulation Size and Thickness: 4X4, 1/2" Top Insulation Fastener/Bonding Material: JM Roof system Urethane Adhesive (RSUA) Base Sheet(s) & No. of Ply(s): DynaWeld Cap (1) Ply Base Sheet Fastener/Bonding Material: Torch Applied Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: JM 80 Mil PVC Membrane Top Ply Fastener/Bonding Material: JM Two Part UTA (Urethane Insulation Adhesive) Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1'6 " oc @ Lap, # Rows, @ "oc Zone 1• "oc @ Lap, # Rows ® "oc Zone 2:—" oc @ Lap, # Rows ® "0 Zone 3 " oc @ Lap, # Rows_ ® "oo ' Number of Fasteners Per Insulation Board: Zone 1' N/A Zone 1- N/A Zone 2• NA Zone 3: N/A Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc, Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. JM 80 Mil PVC Membrane FT. 4' Parapet Height FT. 1/4" High Density Wood Fiberboard 140' 1/4" Poly ISO Mean DynaWeld Cap (1) Ply Roof Height ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:—Zone 2e:_Zone 2n:_Zone 2r:_Zone 3e:_Zone 3r: Deck Type: Type Underlayment Roof Slope'. 12 Insulation: Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: Adhesive Type: Type Cap Sheet--� Mean Roof Height: Roof Covering: Type & Size Drip ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: _xX_= Mg: _=Mn_ Product Approval M, (Zone 2e:_x,l_= )-Mg:_=M,2•_ Product Approval Mr (Zone 2n: _xA_= Mg: Ma, Product Approval Mr (Zone 2r: _X;L_= _)-Mg:_=Mar Product Approval Mt - (Zone 3e: x]L_= I- Mg: _=Mo•_ Product Approval Mr (Zone 3r: _xk_= _J- Mg: _=Mry_ Product Approval Mr Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval M• M, required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 1 24.4 1 25.9 1 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L_=x W:= ) -W: cos r =F,t (Zone 2e: x L= x W:=) -W: cos r =Fr2•_ (Zone 2n: x L= x W:=_) -W: cos r =F,2n_ (Zone 2r: _x L= x W = ) -W: cos r =Fr2r_ (Zone 3e: x L= x W:=) -W: cos r =F,u_ (Zone 3r: x L= x W:=) -W: cos r =F,a,_ Product Approval F' Product Approval F'. Product Approval F', Product Approval F'. Product Approval F', Product Approval F', Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope B Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity M, Product Approval Attachment Resistance Mr Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L= length W =width Product Approval All calculations must be submitted to the building official at the time of permit application.