Loading...
HomeMy WebLinkAboutWhitaker Roofing Permit Information SheetST. LUCIE ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6,7' Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5, Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7, Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. Process No. Contractors Name: C>� License ## L Job Address ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles tal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance roofing ❑ Recovering ROOF SYSTEM INFORMATION t Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) �� Total (SF)_\ Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. eagieview- LENGTH DIAGRAM Total Line Lengths: Ridges = 121 ft Hips = 9 ft Valleys = 76 ft Rakes = 226 ft Eaves = 188 ft Premium Report 2/25/2021 Flashing = 22 ft Step flashing = 86 ft Parapets = 0 ft -It (Vote This diagram contains segment lengths (rounded to the nearest whole number) over 5.0 Feet. In some cases segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). C� 2008-2021 Eagle View Technologies, Inc. and Pictometry Intemational Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered 6y one or more of U.S. Patent Nos. 8,078,436; 8,145,575; 8,170,84J; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 4 Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations Zone 1': _ Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Materi I: Insulation Base Layer: Base Insultation Size a=Thickness:Base Insulation Fastet Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows @ "oo Zone 1:_.._." oc @ Lap, # Rows @ "oc Zone 2:—" oc @ Lap, # Rows @ " o0 Zone 3:_.._." oc @ Lap, # Rows @ "oc Number of Fasteners Per Insulation Board: Zone 1':--Zone 1: Zone 2: Zone 3 Illustrate Components Noted and Details as Applicable: Woodb{ocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. V \ Section D (Steep Slope Roof System) A Roof System Manufacturer: 4' Notice of Acceptance Number: ��A)Q-Vv- T\'-�1C1 • I Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): '�,„ Zone 1: ! Zone 2e: ` -�! Zone 2n: Zone 2r:� +2 Zone 3e: ► P Zone 3r: Deck Type: Type Underlayment: rf Siope: 12 Insulation: Fire Barrier: dge Ventilation? Fastener Type &Spacing:` Adhesive Type: \ Type Cap Sheet: i Mean Roof Height: Roof Covering:" Type & Size Drip Edge: T L 1 1 Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mr values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RAS 12T (Zone 1: x x = j- Mg: = M', Product Approval Mi (Zone 2e: x _ -Mg: = Ma® Product Approval Mf (Zone 2n: x _ - Mg: = Mra, Product Approval Mf (Zone 2r: x _ - - Mg: = M,2,, Product Approval Mf (zone 3e: x?,-= _j-Mg: Mrs Product Approval Mf (Zone 3r: x _ ---- - Mg! = Mra, Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" r �� .+ f Dorm+-. INA_) Grnm Tahla RPInW Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 2.2 33.8 35.1 37.3 5:12 28.4 0.1 31.6 32.8 34.9 6:12 26.4 .0 29.4 30.5 32.4 7:12 24.4 9 7.1 28.2 30.0 *Must be used in conjunctiooMethodVplift T m menL dae • For Uplift based the system3. ompa tl7 equal to the Fr values, for ee ro , the the od 3' plift as (Zone 1: x L =xW. c(Zone 2e: x L =x-W: c(Zone 2n: x L =-W: co (Zone 2r: x L=x- cos (Zone 3e: x L =x W:= ) -W: cos (Zone 3r: x L =x W:= ) -W: cos u a wnu values F' with the values for Fr If the F' values are greater than or ile attachment method is acceptable. e Tile Calculations Per RAS 12T =Fr1 Product Approval F' r =Fr2e Product Approval F' _ r =Fr2n Product Approval F' r =Fr2r Product Approval F' =Fr3e Product Approval F' =Fr3r Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope A Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application.