HomeMy WebLinkAboutrevised energy calcs PERMIT# ISSUE DATE
PLANNING & DEVELOPMENT SERVICES
Building & Code Compliance Division
BUILDING PERT'vHT
SUB-CONTRACTOR AGREEMENT
TOTAL ROOFING SYSTEMS THE METAL ROOF EXPERTS INC. have agreed to be
(Company Naine/Individtial Name)
the ROOFING Sub-contractor for SEGUNDO MALDONADO
(Type of Trad
(Primary Contractor)
For the project located at 5141 NW DUNN RD FORT PIERCE, FL 34981
(Project Street Address or Property Tax ID 9)
It is understood that if there is any change of status regarding our participation with the above mentioned
project, the Building and Code Regulation Division of St.Lucie County will be advised pursuant to the
filing of a Chang of Sub-contractor notice.
e
c6N'rx_a'tToR—siGNATURE(Qualifier)
CTOR SIGNATURE(Qualifier)
"S'V 1.4-,ela 101 o 1/1 ri el_ j DULCE B. LARA I CCCI 332346
PRINT NAME PR M1 NAME
COUNTY CERTIFICATION NUMBER COUNTY CERTIFICATION_NUMBER
State of Florida,County of t4arblo State of Florida,County of MAkTIN
The foregoing instrument was. signed before me this ^ day of The foregoing instrument was signed before me this �_>_day of
20-a-11:by
6— 2q.-_>i by
who is personally know"),—Lor has produced a who is personally known or has produced a
as
I'd C"Hi Ication.
STA414P
Signature I Nota fie Signature of Notar —P SSTAMP0 tnxiT
Print Name of Notary Public Print Name of Notary Public
Ly
THE SA JAFFE
Y PCB Notary Pu
THERESA JAFFE ;kbli -State of Florida
Revised 1111612 Notary Commission GG 202301 Public-State of Florida Commission#GG 202301
My Comm.Expires Apr 1,2022
My Comm.Expires Apr 1,2022 Bonded through National Notary Assn.
Bonded through National Notary Assn.
40
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MALDONADO RESIDENCE Builder Name: FL TREND HOMES
Street: 5141 NW DUNN ROAD Permit Office: ST LUCIE COUNTY
City,State,Zip: FORT PIERCE,FL,34981 Permit Number:02(01-f"0// /Q-7
Owner: SEGUNDO MALDONADO Jurisdiction: ST LUCIE COUNTY
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types (3593.3 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=3.8 3153.30 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 260.00 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 180.00 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (2940.0 sqft.) Insulation Area
a.Roof Deck(Unvented) R=20.0 2940.00 ft2
6. Conditioned floor area above grade(ft2) 2940 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(511.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 125
a. U-Factor: Sgl,U=0.51 216.00 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 175
SHGC: SHGC=0.24
b. U-Factor: Sgi,U=0.65 184.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.22 a.Central Unit 42.0 SEER:16.00
c. U-Factor: Sgl,U=0.39 95.50 ft2 b.Central Unit 18.8 SEER:16.00
SHGC: SHGC=0.25 13.Heating systems kBtu/hr Efficiency
d. U-Factor: other(see details) 16.00 ft2 a.Electric Strip Heat 34.0 COP:1.00
SHGC: other(see details) b.Electric Strip Heat 17.0 COP:1.00
Area Weighted Average Overhang Depth: 6.844 ft.
Area Weighted Average SHGC: 0.234 14.Hot water systems
8. Floor Types (2940.0 sqft'.) Insulation Area a.Electric Tankless Cap:1 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2940.00 ft2 b. Conservation features EF:0.980
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits None
Glass/Floor Area: 0.174
Total Proposed Modified Loads: 93.43 PASS
Total Baseline Loads: 106.32
I hereby certify that the plans and specifications covered by Review of the plans and O��xE S7-
this calculation are in compliance with the Florida Energy specifications covered by this ,y - _ p�
Code. calculation indicates compliance y y� ' `?z,-'� V0
with the Florida Energy Code.
PREPARED BY: Before construction is completed >x � O
DATE: 3-17-202 this building will be inspected for 0I?11�. - X
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Qode.
OWNER/AGENT Pa ��"'6 BUILDING OFFICIAL:
DATE: 7�0Z I DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. GOO
3/17/2021 8:53 AM EnergyGaugeA®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant 01 Page 1 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: MALDONADO RESIDENCE Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2940 Lot#
Owner Name: SEGUNDO MALDONADO Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: FL TREND HOMES Rotate Angle: 0 Street: 5141 NW DUNN ROAD
Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie
Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: FORT PIERCE,
Family Type: Detached FL, 34981
New/Ebsting: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 AHU 1 1928 20780
2 AHU 2 1012 10522
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 4 156 1560 No 0 1 1 Yes Yes Yes
2 GREAT ROOM 500 6500 No 0 1 Yes Yes Yes
3 KITCHEN 180 1800 Yes 0 1 No Yes Yes
4 DINING 226 2260 No 0 1 Yes Yes Yes
5 NOOK 160 1600 No 0 1 Yes Yes Yes
6 PANTRY 16 160 No 0 1 No Yes Yes
7 KIDS ROOM 169 1690 No 0 1 Yes Yes Yes
8 BATH 4 60 600 No 0 1 Yes Yes Yes
9 WIC 30 300 No 0 1 Yes Yes Yes
10 BATH 3 54 540 No 0 1 Yes Yes Yes
11 WIC 3 32 320 No 0 1 Yes Yes Yes
12 BEDROOM 3 144 1440 No 0 1 1 Yes Yes Yes
13 UTILITY 80 800 No 0 1 Yes Yes Yes
14 HALLWAY 68 680 No 0 1 No Yes Yes
15 HALL 24 240 No 0 1 Yes Yes Yes
16 STORAGE 29 290 No 0 1 Yes Yes Yes
17 MASTER BEDROO 402 4422 No 0 1 1 Yes Yes Yes
18 M WIC 1 70 700 No 0 1 Yes Yes Yes
19 M W IC 2 30 300 No 0 1 No Yes Yes
20 M TOILET 28 280 No 0 1 Yes Yes Yes
21 M BATH 192 1920 No 0 1 Yes Yes Yes
3/17/2021 8:53 AM EnergyGaugeA®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
22 HALL 2 20 200 No 0 1 No Yes Yes
23 WIC 2 30 300 No 0 1 Yes Yes Yes
24 BATH 2 60 600 No 0 1 Yes Yes Yes
25 BEDROOM 2 180 1800 No 0 1 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulation BEDROOM 4 13 ft 0 156 ft2 ---- 1 0 0
2 Slab-On-Grade Edge Insulation GREAT ROOM 18 ft 0 500 ft2 ---- 1 0 0
3 Slab-On-Grade Edge Insulation KITCHEN 1 ft 0 180 ft2 ---- 1 0 0
4 Slab-On-Grade Edge Insulation DINING 15 ft 0 226 ft2 ---- 1 0 0
5 Slab-On-Grade Edge Insulation NOOK loft 0 160 ft2 ---- 1 0 0
6 Slab-On-Grade Edge Insulation PANTRY 1 ft 0 16 ft2 ---- 1 0 0
7 Slab-On-Grade Edge Insulation KIDS ROOM 13 ft 0 169 ft2 ---- 1 0 0
8 Slab-On-Grade Edge Insulation BATH 4 8 ft 0 60 ft2 ---- 1 0 0
9 Slab-On-Grade Edge Insulation WIC 4 loft 0 30 ft2 ---- 1 0 0
10SIab-On-Grade Edge Insulation BATH 3 8 ft 0 54 ft2 ---- 1 0 0
11SIab-On-Grade Edge Insulation WIC 3 4 ft 0 32 ft2 ---- 1 0 0
12SIab-On-Grade Edge Insulation BEDROOM 3 12 ft 0 144 ft2 ---- 1 0 0
13SIab-On-Grade Edge Insulation UTILITY loft 0 80 ft2 ---- 1 0 0
14SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 68 ft2 ---- 1 0 0
15SIab-On-Grade Edge Insulation HALL 6 ft 0 24 ft2 ---- 1 0 0
16SIab-On-Grade Edge Insulation STORAGE 16 ft 0 29 ft2 ---- 1 0 0
17SIab-On-Grade Edge Insulation MASTER BEDRO 25 ft 0 402 ft2 ---- 1 0 0
18SIab-On-Grade Edge Insulation M W IC 1 loft 0 70 ft2 ---- 1 0 0
19SIab-On-Grade Edge Insulation M W IC 2 1 ft 0 30 ft2 ---- 1 0 0
20SIab-On-Grade Edge Insulation M TOILET 4 ft 0 28 ft2 ---- 1 0 0
21SIab-On-Grade Edge Insulation M BATH 11 ft 0 192 ft2 ---- 1 0 0
22SIab-On-Grade Edge Insulation HALL 2 1 ft 0 20 ft2 ---- 1 0 0
23Slab-On-Grade Edge Insulation WIC 2 5 ft 0 30 ft2 ---- 1 0 0
24SIab-On-Grade Edge Insulation BATH 2 9 ft 0 60 ft2 ---- 1 0 0
3/17/2021 8:53 AM EnergyGaugeA@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 8
C
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
25SIab-On-Grade Edge Insulation BEDROOM 2 17 ft 0 180 ft2 ---- 1 0 0
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Metal 3185 ft2 0 ft2 Light N 0.1 No 0.9 No 20 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC
1 Full attic Unvented 0 2940 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) BEDROOM 4 0 Blown 156 ft2 0.1 Wood
2 Under Attic(Unvented) GREAT ROOM 0 Blown 500 ft2 0.1 Wood
3 Under Attic(Unvented) KITCHEN 0 Blown 180 ft2 0.1 Wood
4 Under Attic(Unvented) DINING 0 Blown 226ft2 0.1 Wood
5 Under Attic(U nvented) NOOK 0 Blown 160ft2 0.1 Wood
6 Under Attic(U nvented) PANTRY 0 Blown 16ft2 0.1 Wood
7 Under Attic(Unvented) KIDS ROOM 0 Blown 169ft2 0.1 Wood
8 Under Attic(Unvented) BATH 4 0 Blown 60 ft2 0.1 Wood
9 Under Attic(Unvented) WIC 4 0 Blown 30 ft2 0.1 Wood
10 Under Attic(Unvented) BATH 3 0 Blown 54 ft2 0.1 Wood
11 Under Attic(Unvented) WIC 3 0 Blown 32 ft2 0.1 Wood
12 Under Attic(U nvented) BEDROOM 0 Blown 144ft2 0.1 Wood
13 Under Attic(Unvented) UTILITY 0 Blown 80 ft2 0.1 Wood
14 Under Attic(Unvented) HALLWAY 0 Blown 68 ft2 0.1 Wood
15 Under Attic(Unvented) HALL 0 Blown 24 ft2 0.1 Wood
16 Under Attic(Unvented) STORAGE 0 Blown 29 ft2 0.1 Wood
17 Under Attic(Unvented) MASTER BEDRO 0 Blown 402 ft2 0.1 Wood
18 Under Attic(Unvented) M WIC 1 0 Blown 70 ft2 0.1 Wood
19 Under Attic(Unvented) M WIC 2 0 Blown 30 ft2 0.1 Wood
20 Under Attic(Unvented) M TOILET 0 Blown 28 ft2 0.1 Wood
21 Under Attic(Unvented) M BATH 0 Blown 192 ft2 0.1 Wood
22 Under Attic(Unvented) HALL 2 0 Blown 20 ft2 0.1 Wood
23 Under Attic(Unvented) WIC 2 0 Blown 30 ft2 0.1 Wood
24 Under Attic(Unvented) BATH 2 0 Blown 60 ft2 0.1 Wood
25 Under Attic(Unvented) BEDROOM 2 0 Blown 180 ft2 0.1 Wood
3/17/2021 8:53 AM EnergyGaugeA®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
SpaceEt In Et In Areq
1 N Exterior Concrete Block-Int InsuBEDROOM 4 3.85 12 0 10 0 120.0 ft2 0 0 0.1 0
2 S Exterior Concrete Block-Int InsuBEDROOM 4 3.85 12 0 10 0 120.0 ft2 0 0 0.1 0
3 W Exterior Concrete Block-Int InsuBEDROOM 4 3.85 7 0 10 0 70.0 ft2 0 0 0.1 0
4 E Exterior Concrete Block-Int InsuGREAT ROO 3.85 18 0 13 0 234.0 ft2 0 0 0.1 0
5 W Exterior Concrete Block-Int InsuGREAT ROO 3.85 17 0 13 0 221.0 ft2 0 0 0.1 0
6 N Exterior Concrete Block-Int Insul DINING 3.85 13 0 10 0 130.0 ft2 0 0 0.1 0
7 E Exterior Concrete Block-Int Insul DINING 3.85 14 0 10 0 140.0 ft2 0 0 0.1 0
8 S Garage Frame-Wood DINING 11 3 0 10 0 30.0 ft2 0 0.1 0.1 0
9 N Exterior Concrete Block-Int Insul NOOK 3.85 2 0 10 0 20.0 ft2 0 0 0.1 0
10 W Exterior Concrete Block-Int Insul NOOK 3.85 8 0 10 0 80.0 ft2 0 0 0.1 0
11 NW Exterior Concrete Block-Int Insul NOOK 3.85 7 4 10 0 73.3 ft2 0 0 0.1 0
12 S Exterior Concrete Block-Int InsuKIDS ROOM 3.85 13 0 10 0 130.0 ft2 0 0 0.1 0
13 E Exterior Concrete Block-Int Insul BATH 4 3.85 1 0 10 0 10.0 ft2 0 0 0.1 0
14 S Exterior Concrete Block-Int Insul BATH 4 3.85 6 0 10 0 60.0 ft2 0 0 0.1 0
15 W Exterior Concrete Block-Int Insul BATH 4 3.85 1 0 10 0 10.0 ft2 0 0 0.1 0
16 N Exterior Concrete Block-Int Insul WIC 4 4.1 5 0 10 0 50.0 ft2 0 0 0.1 0
17 S Exterior Concrete Block-Int Insul WIC 4 4.1 5 0 10 0 50.0 ft2 0 0 0.1 0
18 E Exterior Concrete Block-Int Insul BATH 3 3.85 1 0 10 0 10.0 ft2 0 0 0.1 0
19 S Exterior Concrete Block-Int Insul BATH 3 3.85 6 0 10 0 60.0 ft2 0 0 0.1 0
20 W Exterior Concrete Block-Int Insul BATH 3 3.85 1 0 10 0 10.0 ft2 0 0 0.1 0
21 S Exterior Concrete Block-Int Insul WIC 3 3.85 4 0 10 0 40.0 ft2 0 0 0.1 0
22 S Exterior Concrete Block-Int InsuBEDROOM 3 3.85 12 0 10 0 120.0 ft2 0 0 0.1 0
23 S Exterior Concrete Block-Int Insul UTILITY 3.85 10 0 10 0 100.0 ft2 0 0 0.1 0
24 E Garage Frame-Wood UTILITY 11 8 0 10 0 80.0ft2 0 0.1 0.1 0
25 N Garage Frame-Wood UTILITY 11 3 0 10 0 30.0 ft2 0 0.1 0.1 0
26 E Garage Frame-Wood HALLWAY 11 4 0 10 0 40.0 ft2 0 0.1 0.1 0
27 N Exterior Concrete Block-Int Insul HALL 3.85 6 0 10 0 60.0 ft2 0 0 0.1 0
28 N Exterior Concrete Block-Int Insul STORAGE 4.1 5 0 10 0 50.0 ft2 0 0 0.1 0
29 S Exterior Concrete Block-Int Insul STORAGE 4.1 5 0 10 0 50.0 ft2 0 0 0.1 0
30 W Exterior Concrete Block-Int Insul STORAGE 4.1 6 0 10 0 60.0 ft2 0 0 0.1 0
31 N Exterior Concrete Block-Int InsuMASTER BE 3.85 18 0 11 0 198.0 ft2 0 0 0.1 0
32 S Exterior Concrete Block-Int InsuMASTER BE 3.85 18 0 11 0 198.0 ft2 0 0 0.1 0
33 W Exterior Concrete Block-Int InsuMASTER BE 3.85 19 0 11 0 209.0 ft2 0 0 0.1 0
34 N Exterior Concrete Block-Int Insul M W IC 1 3.85 10 0 10 0 100.0 ft2 0 0 0.1 0
35 N Exterior Concrete Block-Int Insul M TOILET 3.85 4 0 10 0 40.0 ft2 0 0 0.1 0
36 N Exterior Concrete Block-Int Insul M BATH 3.85 11 0 10 0 110.0 ft2 0 0 0.1 0
37 N Exterior Concrete Block-Int Insul WIC 2 3.85 5 0 10 0 50.0 ft2 0 0 0.1 0
38 N Exterior Concrete Block-Int Insul BATH 2 3.85 10 0 10 0 100.0 ft2 0 0 0.1 0
39 E Exterior Concrete Block-Int Insul BATH 2 3.85 6 0 10 0 60.0 ft2 0 0 0.1 0
40 E Exterior Concrete Block-Int InsuBEDROOM 2 3.85 12 0 10 0 120.0 ft2 0 0 0.1 0
41 S Exterior Concrete Block-Int InsuBEDROOM 2 3.85 15 0 10 0 150.0 ft2 0 0 0.1 0
3/17/2021 8:53 AM EnergyGaugeA®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N 1 Metal Low-E Single Yes 0.65 0.22 Y 40.0 ft2 6 It 6 in 3 It 5 in None None
2 E 4 Metal Low-E Single Yes 0.39 0.25 Y 12.0 ft2 6 ft 6 in 2 ft 0 in Drapes/blinds Exterior 5
3 E 4 Metal Low-E Single Yes 0.51 0.24 Y 32.0 ft2 1 ft 6 in 4 ft 0 in Drapes/blinds Exterior 5
4 E 4 Metal Low-E Single Yes 0.65 0.22 Y 48.0 ft2 6 ft 6 in 5 ft 0 in Drapes/blinds Exterior 5
5 W 5 Metal Low-E Single Yes 0.65 0.22 Y 96.0 ft2 18 ft 6 in 1 ft 5 in Drapes/blinds Exterior 5
6 E 7 Metal Low-E Single Yes 0.39 0.25 Y 20.0 ft2 1 ft 6 in 2 ft 5 in Drapes/blinds Exterior 5
7 E 7 Metal Low-E Single Yes 0.51 0.24 Y 15.0 ft2 1 ft 6 in 2 ft 5 in Drapes/blinds Exterior 5
8 W 10 Metal Low-E Single Yes 0.39 0.25 Y 12.0 ft2 10 ft 6 in 1 ft 5 in Drapes/blinds Exterior 5
9 W 10 Metal Low-E Single Yes 0.51 0.24 Y 21.3 ft2 10 ft 6 in 1 ft 5 in Drapes/blinds Exterior 5
10 NW 11 Metal Low-E Single Yes 0.39 0.25 Y 22.0 ft2 10 ft 6 in 1 ft 5 in Drapes/blinds Exterior 5
11 NW 11 Metal Low-E Single Yes 0.39 0.25 Y 11.5 ft2 10 ft 6 in 1 ft 5 in Drapes/blinds Exterior 5
12 S 14 Metal Low-E Single Yes 0.39 0.25 Y 6.0 ft2 1 ft 6 in 0 ft 0 in None None
13 S 19 Metal Low-E Single Yes 0.39 0.25 Y 6.0 ft2 1 It 6 in 0 ft 0 in None None
14 S 22 Metal Low-E Single Yes 0.51 0.24 Y 15.0 ft2 1 ft 6 in 0 ft 0 in None None
15 S 23 Metal Low-E Single Yes 0.51 0.24 Y 15.0 ft2 1 ft 6 in 0 ft 0 in None None
16 N 27 Metal Low-E Single Yes 0.51 0.24 Y 20.0 ft2 1 ft 6 in 3 ft 5 in None None
17 W 30 Metal Low-E Single Yes 0.51 0.24 Y 16.7 ft2 1 ft 6 in 3 ft 5 in None None
18 N 31 Metal Low-E Single Yes 0.54 0.23 Y 16.0 ft2 1 ft 6 in 0 ft 0 in None None
19 W 33 Metal Low-E Single Yes 0.51 0.24 Y 40.0 ft2 1 ft 6 in 8 It 5 in None None
20 N 36 Metal Low-E Single Yes 0.51 0.24 Y 6.0 ft2 1 ft 6 in 0 ft 0 in None None
21 N 38 Metal Low-E Single Yes 0.39 0.25 Y 6.0 ft2 1 ft 6 in 0 ft 0 in None None
22 E 40 Metal Low-E Single Yes 0.51 0.24 Y 20.0 ft2 1 ft 6 in 2 ft 5 in None None
23 E 40 Metal Low-E Single Yes 0.51 0.24 Y 15.0 ft2 1 ft 6 in 2 It 5 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 966 ft2 966 ft2 18 ft loft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000338 2608.5 143.11 268.67 .1012 5
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1
2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2
3/17/2021 8:53 AM EnergyGaugeA®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 6 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Single SEER:16 42 kBtu/hr 1260 cfm 0.8 1 sys#1
2 Central Unit/ Split Single SEER:16 18.8 kBtu/hr 564 cfm 0.8 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric Tankless Garage 0.98 1 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 125 ftz Attic 13 ftz Prop.Leak Free Attic ---cfm 57.8 cfm 0.03 0.50 1 1
2 Attic 6 175 ftz Attic 18 ftz Prop.Leak Free Attic ---cfm 30.4 cfm 0.03 0.50 2 2
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
CoolingJan Feb Mar Apr Ma rj Jun rl
Jul rl
Au ri
Se Oct Nov Dec
Heatin HJan Feb f X�Mar f APr f May Jun Jul AuSep f Oct X Nov X Dec
Ventin Jan Feb X Mar [X]A r [ Ma Jun Jul Aug Se [ Oct [X Nov [ ]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Cooling(W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 MASTER BEDROO
Default(8 Ibs/sq.ft. ftz ft 0.3 M BATH
Default(8 Ibs/sq.ft. ft? ft 0.3 M WIC
Default(8 Ibs/sq.ft. ftz ft 0.3 M HALL
Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER/DINING
Default(8 Ibs/sq.ft. ftz ft 0.3 HALL
Default(8 Ibs/sq.ft. ftz ft 0.3 GREAT ROOM
Default(8 Ibs/sq.ft. ftz ft 0.3 PANTRY
Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN
Default(8 Ibs/sq.ft. ftz ft 0.3 NOOK
3/17/2021 8:53 AM EnergyGaugeA®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 7 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY
Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2
Default(8 Ibs/s .ft. ftz ft 0.3 CLST 2
3/17/2021 8:53 AM EnergyGaugeA®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 8 of 8
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 88
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New(From Plans) 12. Ducts, location &insulation level
a) Supply ducts R 6.0
2. Detached or multiple-family 2. Detached b) Return ducts R 6.0
c) AHU location Attic
3. No. of units (if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13. Cooling system: Capacity 60.8
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 2940 d) Room unit/PTAC EER
e) Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.539
b) Solar Heat Gain Coefficient(SHGC) 7b. 0.234 14. Heating system: Capacity 51.0
c)Area 7c. 511.5 a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights c) Electric resistance COP 1.0
a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE
f)Other
9. Floor type, insulation level:
a) Slab-on-grade(R-value) 9a. 0.0
b) Wood, raised (R-value) 9b. 15.Water heating system
c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
10.Wall type and insulation: c) Gas fired, LPG EF
A. Exterior: d) Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2.varies f) Heat recovery unit HeatRec%
B. Adjacent: g) Other
1.Wood frame(Insulation R-value) 1081. 11.0
2. Masonry(Insulation R-value) 10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 0.0 b) Cross ventilation No
b) Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e) Multizone heating credit
f) Programmable thermostat No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signatur . 4 �Ga�lJ Date:
Address of New Home: 5141 NW DUNN ROAD City/FL Zip: FORT PIERCE, FL 34981
3/17/2021 8:54:30 AM EnergyGauge(D USA 7.0.00-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MALDONADO RESIDENCE Builder Name: FL TREND HOMES
Street: 5141 NW DUNN ROAD Permit Office: ST LUCIE COUNTY
City,State,Zip: FORT PIERCE,FL,34981 Permit Number: U
Owner: SEGUNDO MALDONADO Jurisdiction: ST LUCIE COUNTY W
Design Location: FL,Fort Pierce U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in an dropped ceiling/soffit
/soffit
Ceiling/attic insulation and an gaps in the air barrier shall be sealed. y pp g
y g p shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a
Knee walls shall be sealed. material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to
(including maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation shall
and cantilevered floors) be permitted to be in contact with the top side of
sheathing,or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation
Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building
be sealed to the drywall. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be
on exterior wall tubs shall separate them from the showers and tubs. insulated.
Electrical/phone box on The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Concealed When required to be sealed,concealed fire sprinklers shall only be sealed
sprinklers in a manner that is recommended by the manufacturer.Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
3/17/2021 8:54 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1