HomeMy WebLinkAboutAPPROVED Engineer ReportENGINEERING 86943 1 44279-5269328704 1 Page 1/2 Date: March 24th, 2021 ASCE 7 Components & Cladding Wall Pressure Calculator Prepared For: 6710 Benjamin Rd. ##200 Tampa FL NOTE: This digitally sealed file is being provided in an unlocked format at the building departments request, Project: Mars Please review any changes/markups to ensure integrity of the source document to prevent fraud. Project Address: 5650 S Ocean Dr. Unit 1908 Jensen Beach Florida Digitally signed by Frank s :,ricrac, ;? ilic�ii?:4L,,�rzF. ��.�nrrira inrirs cF TNm , 8ennardo �N1rymiF os�ei cGa F. LEa'.: Date: 2021.03.24 Box for Engineer Seal Only -Original Rqd for Permit & Use Frank Bennardo, PE FL46549 or Richard hfeet, PE FL86488 The following has been considered in determining allowable stress design (ASD) wall opening pressures for the above - referenced location. ASCE: ASCE 7-10 (6TH EDN FLORIDA BUILDING CODE, 2017 FBC, 2015 IBC) Wind Velocity: 170 MPH Exposure Category: C Kd: 0.85 Kzt: 1 Elevation Above Sea Level: 0 FT Minimum Building Dimension: 170FT Mean Roof Height: 1897T Unit Elevation: 150FT ROOF SLOPE: FLAT (<10°) Number Of Openings: 5 Shutter: YES Mark: 1 Height Of Opening: 61 IN Width Of Opening: 72 IN Zone: 4 Mark: 2 Height Of Opening: 95 IN Width Of Opening: 40 IN Zone: 4 Mark: 3 Height Of Opening: 61 IN Width Of Opening: 52 IN Zone: 4 Mark: 4 Height Of Opening: 95 IN Width Of Opening: 110 IN Zone: 4 Mark: 5 Height Of Opening: 95 IN Width Of Opening: 141 IN Zone: 4 Based on the above, the following ASD design pressures apply for the .>-af £LEVAnor4 a, .EA HORIZONTAL C)1,4ENSM jrsi s WIND - FLOW PLAN VIEW COMPLEX ♦ 5... 9WHANG5> 6al NaoF HELGHY =SO%OFt: STHORIYQNSAL OIM[NSION ­4aF MEAN ROOFHEIGWSMANJ, Ww FVEA6IF 9OTNOT<ey,OF LEAST HOAIIONTALNw IISEON ORSFT. " NSE COANERZONE 51FAT ALL IN QUESTION. AT kOMION FORCES OUMT TO HLIGM• NE16NT/3. Corp. Offce: 160 SW 12th Avenue Suite 106, Deerfield Beach, Florida 33442 (954) 354-0660 1 (866) 396-9999 Team@EngineeringExpress,com I EngineeringExpress,com �� ENGINEERING 86943 144279-5269328704 1 Page 212 opening marks which shall correspond with contractor -supplied building layout: a:17FT Mark: 1 Wail Positve Pressure: 54.6PSF Wail Negative Pressure:-57.7PSF Mark: 2 Wall Positve Pressure: 55.3PSF Wall Negative Pressure:-58.2PSF Mark: 3 Wall Positve Pressure: 56.21PSF Wall Negative Pressure:-58.8PSF Mark: 4 Wall Positve Pressure: 50.4PSF Wall Negative Pressure:-54.8PSF Mark: 5 Wall Positve Pressure: 49.2PSF Wall Negative Pressure: -54PSF Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only (Gcpi=+-0.18). Results are based on contractor -supplied data and are not field verified by this off ice. Input shall be verified by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your openings, visit Engineering Express.com/Wind. Corp. Office: 160 SW 121h Avenue Suite 106, Deerfield Beach, Florida 33442 (954) 354-0660 1 (866) 396-9909 Team@EngineeringExpress.com I EngineeringExpress.com