Date: March 24th, 2021
ASCE 7 Components & Cladding Wall Pressure Calculator
Prepared For:
6710 Benjamin Rd. ##200
Tampa FL NOTE: This digitally sealed file is being provided in an
unlocked format at the building departments request,
Project: Mars Please review any changes/markups to ensure integrity
of the source document to prevent fraud.
Project Address:
5650 S Ocean Dr. Unit 1908
Jensen Beach Florida
Digitally signed
by Frank
s :,ricrac, ;? ilic�ii?:4L,,�rzF.
��.�nrrira inrirs cF TNm ,
8ennardo
�N1rymiF os�ei cGa F. LEa'.:
Date:
2021.03.24
Box for Engineer Seal Only -Original Rqd for Permit & Use
Frank Bennardo, PE FL46549 or Richard hfeet, PE FL86488
The following has been considered in determining allowable stress design (ASD) wall opening pressures for the above -
referenced location.
ASCE: ASCE 7-10 (6TH EDN FLORIDA BUILDING CODE, 2017 FBC,
2015 IBC)
Wind Velocity: 170 MPH
Exposure Category: C
Kd: 0.85
Kzt: 1
Elevation Above Sea Level: 0 FT
Minimum Building Dimension: 170FT
Mean Roof Height: 1897T
Unit Elevation: 150FT
ROOF SLOPE: FLAT (<10°)
Number Of Openings: 5
Shutter: YES
Mark: 1
Height Of Opening: 61 IN
Width Of Opening: 72 IN
Zone: 4
Mark: 2
Height Of Opening: 95 IN
Width Of Opening: 40 IN
Zone: 4
Mark: 3
Height Of Opening: 61 IN
Width Of Opening: 52 IN
Zone: 4
Mark: 4
Height Of Opening: 95 IN
Width Of Opening: 110 IN
Zone: 4
Mark: 5
Height Of Opening: 95 IN
Width Of Opening: 141 IN
Zone: 4
Based on the above, the following ASD design pressures apply for the
.>-af £LEVAnor4 a,
.EA HORIZONTAL C)1,4ENSM
jrsi s
WIND -
FLOW
PLAN VIEW
COMPLEX ♦ 5...
9WHANG5> 6al NaoF HELGHY
=SO%OFt: STHORIYQNSAL OIM[NSION 4aF MEAN ROOFHEIGWSMANJ, Ww FVEA6IF
9OTNOT<ey,OF LEAST HOAIIONTALNw IISEON ORSFT. " NSE COANERZONE 51FAT ALL IN QUESTION.
AT
kOMION FORCES OUMT TO HLIGM• NE16NT/3.
Corp. Offce: 160 SW 12th Avenue Suite 106, Deerfield Beach, Florida 33442
(954) 354-0660 1 (866) 396-9999 Team@EngineeringExpress,com I EngineeringExpress,com
�� ENGINEERING 86943 144279-5269328704 1 Page 212
opening marks which shall correspond with contractor -supplied building
layout:
a:17FT
Mark: 1
Wail Positve Pressure: 54.6PSF
Wail Negative Pressure:-57.7PSF
Mark: 2
Wall Positve Pressure: 55.3PSF
Wall Negative Pressure:-58.2PSF
Mark: 3
Wall Positve Pressure: 56.21PSF
Wall Negative Pressure:-58.8PSF
Mark: 4
Wall Positve Pressure: 50.4PSF
Wall Negative Pressure:-54.8PSF
Mark: 5
Wall Positve Pressure: 49.2PSF
Wall Negative Pressure: -54PSF
Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only
(Gcpi=+-0.18). Results are based on contractor -supplied data and are not field verified by this off ice. Input shall be verified
by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be
within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a
licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your
openings, visit Engineering Express.com/Wind.
Corp. Office: 160 SW 121h Avenue Suite 106, Deerfield Beach, Florida 33442
(954) 354-0660 1 (866) 396-9909 Team@EngineeringExpress.com I EngineeringExpress.com