Loading...
HomeMy WebLinkAboutroof Inforamation sheet 1 17-0 ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A,B,C 1,2,3,4,5.6,7 Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7 Asphaltic Shingles A,B,D I g,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6.7" Wood Shingles and A,B,D 1,2,4,5.6.7 Shakes Other As Applicable 1,2,3,4,5.6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 �fl�� ®�� ST L UCIE WORKS Section A(General Information) Master Permit No. Process No. Contractors Name: RlChie the Roofer License# CCC058021 Job Address 808 Anita St., Port St Lucie, Florida ROOF CATEGORY XLow Slope E3 Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles Metal Panel/Shingles OWood Shingles/Shakes 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. 0 New roof 0 Repair 0 Maintenance X Reroofing 0 Recovering -ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) 504 Steep Sloped Roof Area(SF) 2300 Total(SF) 2805 Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. I ,K3 [ r N Cq- Cq• Vie- 1A M �i S f , c ■■ LUCIE 'CORKS Section D(Steep Slope Roof System) Roof System Manufacturer: Metal Sales Notice of Acceptance Number: FL14645-R4 Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): .Zone 1:_Zone 2e: Zone 2n:-Zone 2r:-Zone 3e: Zone 3r: 84.5 Deck Type: 5/8 Plywood Type Underiayment: Eagle Armor-self Adhersive Roof Slope: 12 Insulation: n/a Fire.Barrier: n/a Ridge Ventilation? Fastener Type&Spacing: #101.5"Woodscrews with self sealing Wisher n/a Adhesive Type: n/a Type Cap Sheet n/a Mean RooFHeight: 15ft Roof Covering: 26ga 5V Crimp Metal Type&Size Drip 2 x 2 galy steel Edge: Section C (Low Slope Roof) Surfacing: 5/8 Plywood Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone V- if oc @ Lap,#Rows ® "oc (Ifa component is not used,identify as"NA") Zone 1• "oc @ Lap,#Rows ® "0 System Manufacturer: Polyglass Zone 2• "oc @ Lap,#Rows oc Product Approval No.: FL1654-R27 Zone 3- "oc @ Lap,#Rows_® moo Number of Fasteners Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone I" Zone 1• Zone 2- Zone 3-. " Zone 1':—Zone 1: Zone 2: Zone 3: -90 Illustrate Components Noted and Details as Applicable: Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping,Etc.. Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base Type:5/8 Plywood Flashing,Component Material,Material'Thickness,Fastener Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: Comply with RAS 111 and Chapter 16.. Slope: 1.5/12 J Anchor/Base Sheet&No.df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: FT. n/a Insulation Base Layer: 1 Base Insultation Size and Thickness: 4'tapered to 1/4" Parapet Base Insulation Fastener/Bonding Material: Height Dekfast#14 OMG 3"round Metal Plate Top Insulation Layer: n/a Top Insulation Size and Thickness: n/a 15 FT. Top Insulation Fastener/Bonding Material: n/a Mean Base Sheet(s)&No.of Ply(s): APP Self Adhering Roof Base Sheet Fastener/Bonding Material: Height n/a Ply Sheet(s)'&No.of Ply(s): 1 Ply Sheet Fastener/Bonding Material: n/a Top Ply: APP Self Adhering Top Ply Fastener/Bonding Material: n/a