HomeMy WebLinkAboutAPPROVED, 20210331_NOTICE OF ACCEPTANCE (NOA)MIAMNDiADE MIAMI-DADE COUNTY
s PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building
Lawson Industries, Inc.
8501 NW 90 Street
Medley, FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Series "4200/6200 Flange -Frame" Aluminum Fixed Window — L.M.I.
APPROVAL DOCUMENT: Drawing No. L4200-6200-1201, titled "Series-4200-6200 Flange Frame
Impact Fixed Window", sheets 1 through 5 of 5, dated 02/21/12, with revision D dated 04/10/20, prepared by
manufacturer, signed and sealed by Thomas J. Sotos, P.E., bearing the Miami -Dade County Product Control
Revision stamp with the Notice of Acceptance number and expiration date by the Miami —Dade County
Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 17-1212.13 and consists of this page I and evidence pages E-1, E-2, E-3, E-4
and E-5, as well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez, P.E.
NOA No. 20-0428.01
M MM 6DE CCK)N Y CIVExpiration Date: August 22, 2022
Approval Date: June 25, 2020
6/18/20 Page 1
Lawson Industries. Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA No. 12-0307.06)
2. Drawing No. L4200-6200-1201, titled "Series-4200-6200 Flange Frame Impact Fixed
Window", sheets 1 through 5 of 5, dated 02/21/12, with revision C dated on 11/01/17,
prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E.
(Submitted under NOA No. 17-1212.13)
B. TESTS
1. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of an arch and a rectangular
fin -frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test
Reports No. HETI-12-4010 and HETI-11-3363, both dated 03/05/12, signed and
sealed by Rafael Droz—Seda, P.E.
(Submitted under NOA No. 12-0307.06)
2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a rectangular, a circular
arch and an elliptical arch fin -frame fixed window, prepared by Hurricane Engineering
& Testing, Inc., Test Reports No. HETI-09-2614 dated 09/04/09, HETI-09-2612
dated 09/02/09, HETI-09-2586 dated 07/10/09, HETI-09-2584 dated 07/10/09,
HETI-09-2582 dated 07/10/09, and HETI-09-2580 dated 07/10/09, all signed and
sealed by Candido F. Font, P.E.
(Submitted under NOA No. 12-0307.06)
3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
along with marked -up drawings and installation diagram of a rectangular fin -frame
fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.
HETI-09-2613 dated 09/04/09, HETI-09-2611 dated 09/04/09, HETI-09-2585 dated
07/10/09, HETI-09-2581 dated 07/10/09 and HETI-09-2579 dated 07/10/09, all
signed and sealed by Candido F. Font, P.E.
(Submitted under NOA No. 12-0307.06)
4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
along with marked -up drawings and installation diagram of a rectangular fin -frame
fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.
HETI-03-1778 dated 01/30/03, HETI-03-1779 dated 01/30/03 and HETI-03-1776
dated 01/30/03, all signed and sealed by Rafael Droz-Seda, P.E.
(Submitted under NOA No. 03-0327.11)
Manuel et0428
.
Product Control Ee
NOA No. 2 Expiration Date: August22
Approval Date: June 25, 2020
E-1
Lawson Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS (CONTINUED)
5. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a rectangular, a circular
arch and an elliptical arch fin -frame fixed window, prepared by Hurricane Engineering
& Testing, Inc., Test Reports No. HETI-03-1777 dated 01/30/03, HETI-03-1774A
dated 01/30/03, and HETI-03-1774B dated 01/30/03, all signed and sealed by Rafael
Droz-Seda, P.E.
(Submitted under NOA No. 03-0327.11)
6. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
along with marked -up drawings and installation diagram of a circular arch fin —frame
fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.
HETI-02-1215 dated 04/08/02 and HETI-01-1193 dated 04/08/02, both signed and
sealed by Hector Medina, P.E.
(Submitted under NOA No. 02-0701.01)
7. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a rectangular, a circular
arch and an elliptical arch fin -frame fixed window, prepared by Hurricane Engineering
& Testing, Inc., Test Reports No. HETI-02-1158 dated 04/08/02, HETI-01-1103
dated 02/12/02 and HETI-01-1098 dated 02/11/02, all signed and sealed by Hector
Medina, P.E.
(Submitted under NOA No. 02-070L 01)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC,
prepared by manufacturer, dated 03/01/12, signed and sealed by Thomas J. Sotos, P.E.
(Submitted under NOA No. 12-0307.06)
2. Glazing complies with ASTM E1300-04/09
D. QUALITY ASSURANCE
1. Miami —Dade Department of Regulatory and Economic Resources (RER).
Manuel Perez, P.E.
Product Control Ex r
NOA No. 2 28.0
Expiration Date: August 22, 2
Approval Date: June 25, 2020
E-2
Lawson Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No.16-1117.01 issued to Kuraray America., Inc. for their
"Trosifol® Ultraclear, Clear, and Color PVB Interlayers" dated 01/19/17, expiring
on 07/08/19.
2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America., Inc. for their
"SentryGlas® (Clear and White) Interlayer" dated 06/25/15, expiring on 07/04/18.
3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA)
for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET
Core" dated 06/19/14, expiring on 12/11/18.
F. STATEMENTS
1. Statement letter of conformance to FBC 6a' Edition (2017) and of "no financial
interest" dated 11/17/17, prepared by the manufacturer, signed and sealed by Thomas
J. Sotos, P.E.
(Submitted under NOA No. 17-1212.13)
2. Statement letter dated 01/22/18 of the editorial drawing changes issued by Lawson
Inc, signed by Nelson Erazo, Senior Design Engineer.
(Submitted under NOA No. 17-1212.13)
3. Laboratory compliance letter for Test Reports No. HETI-09-2614 dated 09/04/09,
HETI-09-2612 dated 09/02/09, HETI-09-2586 dated 07/10/09, HETI-09-2584 dated
07/10/09, HETI-09-2582 dated 07/10/09, HETI-09-2580 dated 07/10/09,
HETI-09-2613 dated 09/04/09, HETI-09-2611 dated 09/04/09, HETI-09-2585 dated
07/10/09, HETI-09-2581 dated 07/10/09 and HETI-09-2579 dated 07/10/09, all
issued by Hurricane Engineering & Testing, Inc., signed and sealed by Candido F.
Font, P.E.
(Submitted under NOA No. 12-0307.06)
4. Laboratory compliance letter for Test Reports No. HETI-124010 dated 03/05/12,
HETI-11-3363 dated 03/05/12, HETI-03-1778 dated 01/30/03, HETI-03-1779 dated
01/30/03, HETI-03-1776 dated 01/30/03, HETI-03-1777 dated 01/30/03,
HETI-03-1774A dated 01/30/03 and HETI-03-1774B dated 01/30/03, all issued by
Hurricane Engineering & Testing, Inc., signed and sealed by Rafael Droz-Seda, P.E.
(Submitted under NOA No. 12-0307.06)
G. OTHERS
1. Notice of Acceptance No. 17-0531.05 issued to Lawson Industries, Inc. for their
Series "4200/6200 Flange - Frame" Aluminum Fixed Window — L.M.I., approved on
08/17/17 and expiring on 08/22/22.
Manuel Perez, P.E.
Product Control Ea
NOA No. 20- 28.01
Expiration Date: August 22,
Approval Date: June 25, 2020
E-3
Lawson Industries. Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. L4200-6200-1201, titled "Series-4200-6200 Flange Frame Impact Fixed
Window", sheets 1 through 5 of 5, dated 02/21/12, with revision D dated on 04/10/20,
prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E..
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
5) Large Missile Impact Test per FBC, TAS 201-94
6) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 4200/6200
aluminum fixed window, glazed with'/I6" HS laminated glass, prepared by
Fenestration Testing Laboratory, Inc., Test Report No. FTL-12021, dated 03/20/20,
signed and sealed by Idalmis Ortega, P.E.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 61h
Edition (2017), prepared by manufacturer, dated 04/17/20, signed and sealed by
Thomas J. Sotos, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19,
expiring on 07/08/24.
2. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their
"Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer" dated 05/23/19,
expiring on 05/23/24.
3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA)
for their "Saflez CP - Saflex and Saflez HP Composite Glass Interlayers with PET
Core" dated 05/17/18, expiring on 12/11/23.
Manuel Perez, P.E.
Product Control Exa
NOA No. 20- 28.01
Expiration Date: August 22,
Approval Date: June 25, 2020
E-4
Lawson Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED (CONTINUED)
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 6th Edition (2017), dated April
17, 2020, issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E.
2. Statement letter of no financial interest, dated April 17, 2020, issued by manufacturer,
signed and sealed by Thomas J. Sotos, P.E.
3. Proposal No. 19-1138 issued to Lawson Industries, Inc. by the Product Control
Section, dated October 18, 2019, signed by Ishaq Chanda, P.E.
G. OTHERS
1. Notice of Acceptance No. 17-1212.13, issued to Lawson Industries, Inc. for their
Series "4200/6200 Flange - Frame" Aluminum Fixed Window — L.M.I., approved on
02/01/18 and expiring on 08/22/22.
Manuel PertP.E.'Product Control ExNOA No. 20-Expiration Date: August 2
Approval Date: June 25, 2020
E-5
SERIES-4200 / 6200 FIXED IMPACT WINDOW - FLANGE FRAME
APPROVED WINDOW ELEVATIONS (L.M.IMPACT)
VIN)OW
HEIGHT
WINDOW
WIDTH
OUARTER-ROUND
WINDOW
HEIGHT
jIL.�
HALF
WIN
HEIGHT
LEG HT.
ARCHED
WINDOW VIDTN
WINDOW WIDTH
PICTURE WINDOW
ELEVATION
-ROUND TYPICAL ELEVATION
V1mW
HE0
�vlwnoW
vinrH
HEXAGON TYPWA ELEVATION
WINDOW
HEIGHT
L.WINDOW WIDTH
WINDOW
HEIfiHT
RECTANGULAR
WINDOW WIDTH
TYPICAL ELEVATION
SQUARE PICTURE WINDOW FLVATION
r— 0
WIN
HEIGHT
FULL ROUND TYPICAL ELEVATION
WINDOW _
HEIGHT
VI [D�OV
HE OW LIJ HT.
VM➢OV VIDTN
SQUARES PICTURE WINDOW ELEVATION
VI.. WIDTH
RECTANGULAR TYPICAL ELINATION
WIN0
HEIGHT
WINDOW
WnLj
OVAL TYPICAL ELEVATION
V1N�
HE T
LEG HT.
I OV
WINDOW
HEIGHT
WINDOW WIDTH
t EGGED EYE BROW FLAATION
VINDOV VI➢TH
QUARTER -ROUND NATION
WINDOW
HEIGHT
WIDOW
W.
OCTAGON TYPK& ELNATION
ALLOWABLE LOADS FOR ALTERNATE
SHAPES AS SHOWN, CAN N VERIFIEDHA
BY INSCRIBING PICTURE WINDOW SHAPE
WITHIN A SQUARE OR RECTANGLE, AS
SHOW IN DOTTED LINES AND OBTAINING
ALLOWABLE LOADS FROM THOSE
SHAPES. PROVIDED PERIMETER
FASTENERS ARE AS DESCRIBED HEREIN
FOR SIZE AND SPACING.
WINDOW
HEIGHT
WINDOW WIDTH
1 IPTI e W TYPICAL ELCMILON
74,000'
WINDOW WIDTH
70.81
D.L. OP . 12'
MAX,
A
TYP.
6
MA%.
i
AT C
Lo
�-iWN
.,
p
a
t7
/XX»LLAJA g
D
q�F1
i,
i
TYP.
DRHERS
AX.
iYP.
76,000'
WINI710W WIDTH
S+FI a•
.L. OPG. la' MAX.
TYP.
rDD
z
-Lj i1
rm
3
ii ' ii
12' MA%.
TYP.
V V I I VIV I
TYPICAL ELEVATION
TESTED UNIT
EXT. 6. TNT, FALSE COLONIAL)
MUNTINS ARE APPLIED V/
NOTE: W/ SILICONE AND ARE
TYPICAL ELEVATION AT
TESTED UNIT
MAXIMUM GLASS AREA TESTED APPLIES AVAILABLE AS OPTIONAL. NOTE:
TO GLASS TYPES: E. F, K AND L. - SEE MAXIMUM GLASS AREA TESTED APPLIES
DESIGN LOAD CAPACITY TABLES ON TO GLASS TYPES: J - SEE DESIGN LOAD
SHEET 4 FOR SIZE LIMITATIONS OF EACH CAPACITY TABLES ON SHEET 4.
GLASS TYPE.
WINDOWS ARE L.M. IMPACT
MIAMI-DADS COUNTY APPROVED
General Notes I SHUTTERS NOT REQUIRED
1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS
OF THE FLORIDA BUILDING CODE (2014-5th Edition & 2017-6th Edition) INCLUDING
HIGH VELOCITY HURRICANE ZONE (HVHZ) AND ASTM 1300-09. THIS PRODUCT IS IMPACT
RESISTANT. (SHUTTERS NOT REQUIRED)
2.) WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE BUILDING
RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH THE REQUIREMENTS
OF F.H.C. & TO BE REVIEWED BY BUILDING OFFICIAL.
3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW SIZES
ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.) .
4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO BE ENGINEERED
ON A SITE SPECIFIC BASIS, UNDER SEPARATE APPROVAL AND TO BE REVIEWED BY
BUILDING OFFICIAL.
5.) WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS TYPES, AND
FOR USE WITH DOUBLE GLAZE LAMINATED INSULATED GLASS TYPES TABULATED HEREIN;
(SEE SHEET p3 FOR GLASS TYPES AND SHEET #4 FOR MAX. DESIGN PRESSURES).
6.) WINDOWS WITH GLASS TYPES -B, C, F, OR G- INSTALLED ABOVE 304t. IN THE HVHZ, THE
I.G. EXTERIOR LITE SHALL BE TEMPERED TO COMPLY WITH THE SMALL MISSILE IMPACT
RESISTANCE REQUIREMENTS (FBC-Chapter 24 Section 2411.3.3.7).
7.) FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHEETS 2 & 5.
6.) EXT. & INT. FALSE COLONIAL MUNTINS ARE OPTIONAL & AND ARE APPLIED W/ SILICONE
9.) WOOD BUCKS IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED AND ANCHORED
(BY OTHERS), PRIOR TO WINDOW INSTALLATION. (SEE SHEET #2 FOR DETAIL & NOTES)
10.) APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE MULLED UNITS.
11.) MULLING FIXED WINDOWS WITH OTHER TYPES OF MIAMI-DADE COUNTY APPROVED PRODUCTS
USING A MIAMI-DADS COUNTY APPROVED MULLION IN BETWEEN ARE ACCEPTABLE BUT THE
LOWER DESIGN PRESSURE FROM THE WINDOWS OR MULLION APPROVAL WILL APPLY YO THE
ENTIRE MULLED SYSTEM.
12.) SEE SHEET # 5 FOR MULLION/METAL ATTACHMENT DETAILS & OPTIONS.
4,4`TY1Cf i➢NbAd�
014 S.M.S. W/ I I/4'
MIN. EMBEDMENT INTO WGUR
(SEE ELEVATION AT SHEET BI
FOR MAX. FASTENER SPACING) 1/4• MAX. INTERIOR
SHIN SPACE
INTERIOR FINISH ---
NOT BY LAWSON INDUSTRIES, INC.
Li3•mm®
EXT. GRADE BACK BEDDING
TO BE APPLIED BEHIND
WINDOW FRAME FLANGE BY
INSTALLER <TYP.)
<cuY+uiA4lY}JrtiiNTN-h4 .... ,•:{
wc�x+ue«u«wcu n ^
EXTERIOR
.X ;,• :Ct L.N
EXT. GRADE PEAIETER
CAULKING NOT BY
LAW= INDUSTRIES',
TO BE APPLIED BY OTHERS
C 1 IAO
(TYP.)
STUCCO OVER METAL LATH NAILED TO
EXTERIOR GRADE PLYWOOD SHEATHING
TD K SPECIFIED BY ARCHITECT OR G.C.
(EXTERIOR FINISH BY OTHERS)
MOT BY LAWSON INDUSTRIES, INC.
WOOD FRAME INSTALLATION
DETAIL
WINDOW INSTALLATION NOTES:
1. THE WINDOW FRAME FLANGE TO BE BACK -BEDDED W/ AN EXT.
GRADE CAULK THROUGHOUT THE ENTIRE PERIMETER OF FLANGE
BY WINDOW INSTALLER (TYP.)
2. THE EXPOSED EXT. PERIMETER OF THE WINDOW FRAME TO
BE CAULKED AND SEALED W/ AN APPROVED EXTERIOR GRADE
CAULK BY OTHERS (TYPJ
3. WOOD BUCK SPECIFIC GRAVITY = 0.55 MIN.
4. CONCRETE COMPRESSIVE STRENGHT = 2Ks1 MIN.
• WHEN THE GAP BETWEEN THE WINDOW FRAME AND THE BUCK OR
MASONRY IS LESS THAN 1/8-, SHIMS ARE NOT REQUIRED.
ANCHORS NOTE:
ANCHORS TO BE R14 SMS OR WD. SCREWS INTO WOOD, OR 1/4'
ITW BUILDEX TAPCONS or ELCO ULTRACON CONC. FASTENERS
INTO CONCRETE (2KSI MIN.), WITH A MINIMUM OF 1 1/4'
PENETRATION INTO WOOD OR CONC, AT 12' O.C. MAX.
■ TAPCON YIELD STRENGTH, Fy=l00Ksl
ULTIMATE STRENGTH, Fu=125Ks)
ALL WOOD BUCKS IN CONTACT WITH CONCRETE —
(NOT BY LAWSON IND.) TO BE PRESSURE TREATED S
6 TO BE REVIEWED BY BLDG. OFFICIAL (TYP.)
(SEE GENERAL NOTES AT SHEET 81)
EXT. G
CAULK
EXT. GRADE
CAULK --\
#14 S.M.S. W/ 1 I/4'
MIN, EMBEDMENT INTO WOOD,
(SEE ELEVATION AT SHEET Bl
FOR MAX. FASTENER SPACING)
SILICONE ADHESIVE
�/ 10 BEDDING COMPOUND
/ I INTERIOR r-LAMINATED GLASS
a II
EXT, GRADE O EXTERIOR
CAULK EXTERIOR GRADE —
PERIMETER CAULKING
4—WINDOW FRAME WIDTH
R14 S.M.S. W/ 1 1/4'
1/4' TAPCON W/ 1 1/4'
MIN. EMBEDMENT INTO WOOD.
MIN, EMBEDMENT INTO CONC,
(SEE ELEVATION AT SHEET Bl
(SEE ELEVATION AT SHEET 81
FOR MAX. FASTENER SPACING)
FOR MAX. FASTENER SPACING)
1 1/4' NUN. ��, P • , .
EMBEIBIENT ;Y. F '•,e . 6, > .
A2 �•' :• : �' •,'a
EXTERIOR GRADE
PERIMETER CAULKING
C
EXTERIOR
a
MAX.
1IM
YP
EXTERIOR GRADE=
PERIMETER CAULKING
WOOD BUCKS
A
I
b I
<o
' 1/4' TAPCON W/ 1 1/4'
M 0 I
")
MIN. EMBEDMENT INTO CONC.
(SEE ELEVATION AT SHEET #1
.1 �
a
FOR MAX. FASTENER SPACING)
O
q N
l O
d a
Z o
s/a% MtN
I
o
W = �
to x a
11/8, MIN.
EDGE DISTANCE
P.T WOOD BUCK NOT BY LAWSON IND.
MUST SUSTAIN IMPOSED LOADS
P' a
e AEMBQDMENT d`
SILICONE ADHESIVE
BEDDING COMPOUND
INTERIOR
GLASS
e.. • a
y' INA' d'
MBENET.
,.
III
cq
i
i
O
N
i m
I
co
C
z
O
z
m
6
M 4
V)
o
gig
$
F
o
g
3
d
i
0
LAMINATED INSULATED GLASS COMPOSITION TYPE B
ITEM
DESCRIPTION
DETAIL
(a) d/1L
a)IY
aaw
1
1/8' ANN. GLASS
2
0.090' SAFLEX PVB by Eastman Chemical Co.
3
1/8' ANNEALED GLASS
4
1/4' INSULATED AIR SPACE
5 CU
1/8' ANNEALED OR TEMPERED GLASS
LAMINATED INSULATED GLASS COMPOSITION TYPE C
ITEM
DESCRIPTION
I ETAIL
1
1/8' ANNEALED GLASS
3n6•
® w
2
0.090' SAFLEX PVB by Eastnan Chemlcal Co,
3
1/8' ANNEALED GLASS
4
1/4' INSULATED AIR SPACE
5 (a)
3,116' ANNEALED OR TEMPERED GLASS
LAMINATED INSULATED GLASS COMPOSITION TYPE F
ITEM
DESCRIPTION
________._.IL
® v4•I_
T` -- - - - =
1
1/8' HEAT-STRENGHTENED GLASS
2
0.090' TROSIFOL PVH by Kuraray Americo, Inc.
3
4
1/8' HEAT-STRENGHTENED GLASS
1/4' INSULATED AIR SPACE
5 C-)
1/8' ANNEALED OR TEMPERED GLASS
1
LAMINATED INSULATED GLASS COMPOSITION TYPE G
ITEM DESCRIPTION I
DETAIL
1 1/8' HEAT-STRENGHTENED GLASS 2/16 ❑- - ;:L
2 0.090' TROSIFOL PVB by Kuraray America, Inc. ® 1/✓41
3 1/8' HEAT-STRENGHTENED GLASS - -�
w
4 1/4' INSULATED AIR SPACE _
5 C.) 3/16' ANNEALED OR TEMPERED GLASS
LAMINATED INSULATED GLASS COMPOSITION TYPE L
ITEM
DESCRIPTION
DETAIL
I
3/16'
1
3/16' HEAT-STRENGHTENED GLASS
2
0.090' TROSIFOL PVB by Kuraray America, Inc.
3
4
3/16' HEAT-STRENGHTENED GLASS
1/4' INSULATED AIR SPACE
' w'' __ _T7 7
5
3/16' TEMPERED GLASS
1.) SEE SHEET 4 FOR DESIGN LOADS LOAD CAPACITY TABLES.
1�0 WINDOWS WITH GLASS TYPES "B, C, F. OR G" INSTALLED
ABOVE 30 FT. IN THE HVHZ, THE I.G. EXTERIOR LITE SHALL
BE TEMPERED TO COMPLY WITH THE SMALL MISSILE IMPACT
RESISTANCE REQUIREMENTS (FBC-2014, Section 2411.3.3.7).
9 5 1:
12
'SILICONE OPTIONS',
---- ---- - DOW CORNING 899 __
SCHNEE-MDREHEAD 5731 _ _ _ _ _ _ _ _
TREMCO SPECTRUM 2
LAMINATED LAMINATED F
INSULATED -0600• INSULATED 0600.
GLAZING DEPTH GLAZING DEPTH
LAMINATED ANSULATED GLASS TYPICAL GLAZING DETAILGLASS TYPICAL GLAZING DETAIL
5 18 LAMINATED GLASS COMPOSITION - TYPE A
DIEM
CLASS DESCRIPTION
1
1/8' ANNEALE➢ GLASS�R4
2
0.090' TROSIFOL PVH by Kuraray America, Inc.3
1/8' ANNEALED GLASS
j
5 18 LAMINATED GLASS COMPOSITION - TYPE D
ITEM
GLASS DESCRIPTION
I
-__DETAIL
-
1 0.�0•
l
I/8' HEAT-STRENGHTENED GLASS
2
0.090' TROSIFOL PVH by Kuraray America, Inc.
3
1/8' HEAT-STRENGHTENED GLASS
13 32 LAMINATED GLASS COMPOSITION - TYPE E
ITEM GLASS DESCRIPTION DETAIL
1 3/16' HEAT-STRENGHTENED GLASS
2 0,090' SAFLEX PVB by Eastnan Chemical Co.
3 1/8• HEAT-STRENGHTENED GLASS 1 0.4�•
7 18 LAMINATED GLASS COMPOSITION - TYPE H
ITEM
CLASS DESCRIPTION
DETAIL-�
1
3/16' ANNEALED GLASS
_
_ a4sr
I,.•
2
0,090' SAFLEX PVB by Eastman Chemic¢t Co.
3
3/16' ANNEALED GLASS
7 18 LAMINATED GLASS COMPOSITION - TYPE I
ITEM GLASS DESCRIPTION DETAIL,
1 3/16' ANNEALED GLASS 3n6 _ :_-T
2 0.090' TROSIFOL PVB by c¢, In Kurnr¢y Amerlc. A. 3n6 = 1
3 3/16' ANNEALED GLASS 1
7 16 LAMINATED GLASS COMPOSITION - TYPE d
ITEM GLASS DESCRIPTION DETAIL
1 3/16' HEAT-STRENGHTENED GLASS 3/16 _
a -0.160
2 0.090' SENTRYGLASS by Kurnray America, Inc. n6
3 3/16' HEAT-STRENGHTENE➢ GLASS
7 18 LAMINATED GLASS COMPOSITION - TYPE K
ITEM
CLASS DESCRIPTION
DETAIL
1
3/16' HEAT-STRENGHTENED GLASS
3n6• ____ __ _ _ _ _�
.0. 0.
1
2
0.090' TROSIFOL PVB by Kuraray America, Inc.
3
3/16' HEAT-STRENGHTENED GLASS
SILICONE
SCHNEE-MOREHEAD SM 5731
DOW CORNING 899
TREMCO SPECTRUM 2
LAMINATED
s HI MONOLITHIC
Ilp 1l�i
141;�i�
GAZING STOP
0 CIRCULAR WOWS.
LAMINATED 3 LAMINATED 4
MONOLITHIC MONOLITHIC
0.600' GLAZING DEPTH DEPTH GLAZING DEPTH
2
LAMINATED
MONOLITHIC
'SILICONE OPTIONS'
DOW CORNING 899
SCHNEE-MDREHEAD 5731
TREMCD SPECTRUM 2
0.600'
GLAZING DEPTH
En
z
10
you Cs
1=
e
m 0 z
� O
m
0 C'
g'v
a
o
J Z c
h
U
Ltd. N
�.a+ 2 il-5
aoin. !
.. S
t
�
Ca
ro
I
o
cq
.4
N
y
C
ca
O .4
R6
M
CO
V
O
O
a
-91
i tit
fj�
gg
rp
y
gQ�
$
y
2
fR N
x
Ix xxx
xxxx$xx
xgxx
xggxx
x$
x$$$xxgggggggg$gggo,
+
O
O
v<
m
v
x xx$xxxxxxxgxx
xgg.....ggxx
xggg%x$$$$$g$$$g$g
+
$,®
Xx
x%xxx
xggxx
xgxxXxx
%$$%x
xggxx
xggxx
S
8
+
_
g
xxxgxx
x$xxxx$$xx%
xggxx..
xgggxx
xgggxxxxg$$gxgxxxxxxggxggop
$
v
Xg8xgxXgxg%%j,gg%%xgggNg%xX$Ngf°T$t°JI$NN$t°Tf°T$gg{TNg(°l,4°'iNYR'gNgNg$gt°T°Tt°TN$Nom
q
p
q
+
T
IN}I
x x
x x
$ %
%
% $
x %
x x
$ six
x
%
x $
$ $ %
x
x
$ $
$ x
x x
$ $
$ $
x x
P. $
$ $
$ g
$ $
g $
g g
$ $
g MIA
g g
o.T
5 (A
D,
to n
ti
x
xxxxx
xx$xx
x$xxxxx
w
soxxxxxm
xg$$xx
x$$$xx$$$$$$$$$$$$$$$$$$$opm-�
v
w
xx
x xxxxxxgxxxxxgxxxxAx
x xxx
%xxx
x�
x
g x
x x
x� ass.
x x
x�
g g
MIX
m m?
x
g x
x x
x g$
g g
O
m
H
pS
9
8
.......gggxx
xgx$xXx?�$-$gx
$$$$$$$�-
q
xxxxXx
%$xxx
X$xxxxXxgg
C!
Z. N
1 O
VV
O N
t o A
a
[VJ � fVT
V
01 W
V
P V
(Vn N
N N
m m
V
O D P w
N N
N UJi
� O�
v
O�
N
V m
0 m
V
00 ��
qJD
OJD �
V
g D m
v
0 0 0
V
V
x
$ $
$ X
$ $
$ $
% N
$ $
$ $
x x
$ $
$ $
ONi $ x
X %
$ $
N $
$ $
$ $
$ N
N $
x $
$ $
$ $
$ $
$ $
N $
N $
N $
to
V
N
T
x$$$xxg$$xx$$$$xxx$$$$$xxx$$$$$$ggg$gggxx$$xg$g$$ggg$$$$gggg$or
9
L
f
^, z--W
ox
z 93
101
w(n
DN �
1_ h4E o
z
g�K IN
oodn„� o
aw
-0
to
0
z
w
ra d M
N
z
m
m?
Y'
Y"P
`:
POIY�
YP
Y'gW
Y'P
Y'�
1"�
Y'
�W_'_P
-1
�_'�
S
,',
i s
°A
`y
^E
yr3�'oo�
'Ir��log41-5im
.yak?
i OP
=
O
xxxxxxxxggxxxgxxxg$$xx$gggg$gg
gg$goa
m
v
p
xggxx.xxgxxxxggxxggg%xgggggg$g$g$gg�m
+
g
x g
g x
x x
x x$$
x
x$ Io
x
x g$$
x x$$$$$$$
g$$$$$
pf1
T
8
xx$$gxxxxggggg$$p
p
a
q
N$$
111a
$$
$$
$g4®11.938
tNn $$$
$$
OO�
a atg$N
$a
V,
m. a
$$
g$
;
9 T
o
q
I-
IsIals
x
x
Ix
x $
$ $
X $
$ $
$ X
$ $
$ $
$ $
$ $
$ $
$ $
$ $
$ $
$ $ $
T
Y fTl
mw
xggxxxxx$$$XX$$gx$$$$$$$$$$$$$g$g$$$oQm
x
gxxxx
Hal-
xxgx
x$gxxggxmm�gxgggg$os
a
z
xggxxx%xggXxggxxaggx,Nggmmx$$g$g$'v-
V J
N NNNm�m
V N
N
Iv.
N® JIl
VV
V V
mC
VN b
OD VOo
.V to
mPP
de00oaOmN
i
D
1Y
ci
4
.�
qq
d
pp
qq
q
pqq
q,
mm p
O
a
y
x
g$g$
X$gggggggggggxxxggggggggxxg
g$
gxor
ro
T
B. Comp6anae'r/ FM ,StA Eddlon (2014)
and ASIM E1500-09
C. Cempugnce r/ 2077 FBC 6tA Edition
`e �y
0. Revised to gwfify QSq.Fl. Mod"
90
L 1 VI' MEDLEY, F LORIDAT 33166
D l]E:E31 I C • PH No. (305) 696-8660
MANUFACTURER OF QUALITY ALUMINUM WINDOWS AND GLASS DOORS
SERIES 4200 6200 FLANGE FRAME IMPACT FIXED WINDOW
LAMINATED GLASS DESIGN PRESSURE CHARTS
L4200-6200-1201 1— 4 OF 5
BILL OF MATERIALS
ITEM
PART /
QUANTITY
DESCRIPTION
MATERIAL
REMARKS
1
L-4201
2
FRAME HEAD/SILL/JAMB
6063-T6
-
2
L-7708
4
GLAZING BEAD (5/16" GLASS)
6063-T6
-
3
L-7708
4
GLAZING BEAD (3/8" & 13/32" GLASS)
6063-T6
-
4
L-7708 TRIMMED
4
GLAZING BEAD (7/16" GLASS)
6063-T6
-
5
L-7711
4
GLAZING BEAD (5/16" GLASS- INSULATED)
6063-T6
-
6
L-6211
4
GLAZING BEAD (7/16" GLASS - INSULATED)
6063-T6
-
7
#8 X 3/4"
2/ CORNER
ASSEMBLY SCREWS
-
P.H. PHILLIPS
8
L-4204
AS REOD.
GLAZING BEAD AT CIRCULAR WDWS.
6063-T5
-
9
VWS-004
AS REOD.
GLAZING GASKET
SOFT PVC
-
10
+
AS REDD.
GLAZING SILICONE
-
11
PL 75.6020
1 AS REOD.
GLAZING SETTING BLOCK
SOFT PVC
1/8" X 1/8" X 2"
12
812-25H-357
I AS REOD.
"TruSeal" Oura Seal Swiggle Spacer
1/4" BLACK
1/4" AIR SPACE
WINDOW FRAME EXTRUSION DETAILSD�TAI
2.643
310
281
.7B�-.850
TYP
—7
040
—91
050
TYP
808
4�-t5D9
.773
FRAME HEAD/SILL/JAMB
2 GLAZING STOP
(5/16" GLASS)
310
.850.040 � �
272
,OS' O r.250
O50
050
TYP.
TYP. .773 F-
173
3 GLAZING STOP
4 GLAZING STOP (7/16" GLASS)
(3/8" & 13/32" GLASS)
.310
O50
.850
oso
TYP.
L
O50
5 684
INSULATED GLAZING STOP
W/ 5/16" LAMINATED GLASS
6 eoo
INSULATED GLAZING STOP
W/ 7/16" LAMINATED GLASS
.050
TYP. �1
II��UIJI 808
8 .466-" SUTACITEay P
Kury
Qy
.Inc.
GLAZING STOP (CIRCULAR WOW.)
SEE MULLION APPROVALS FOR
MULLION TYPE, 51ZE AND MAX.
DESIGN PRESSURE LIMITATIONS,
ALUMINUM MULLION -
(ALUM. 0.078" MIN. THICK)
NOTE: THE LOWER PRESSURES OF
THE WINDOW OR MULL SHALL GOVERN
INTERIOR
FRAIIF MFAO r;,,re5
'/x' . s- Irw
® �.F.�Sll- HEAD
\ \
FRAME JAMI
7 RECT. OR SQUARE WINDOWS
ryppW$ TYPICAL CORNER CONSTRUCTIO
CIR O CMITERR CORNERS O
FRAME RADIUS
RR JOINT FRAME END CORNER
FRAME CORNER & JOINT DETAILS
JOINT DETAIL
SEALANT
'
FRAME CORNERS, OR JOINTS SEALED WITH A COLORED
SEALANT AND PERIMETER OF GLAZING BEAD WITH CLEAR
SILICONE
It 12 X 3/4' S,D,S,
FLAT HEAD, PHILLIPS.
AT 12' D.C. MAX.
EXTERIOR
EXTERIOR GRADE E2
— WINDOW FRAME
PERIMETER CAULKING
FRAME MULLING
DETAIL
SEE MULLION APPROVALS FOR
MULLION TYPE, SIZE AND MAX.
DESIGN PRESSURE LIMITATIONS.
INTERIOR NOTE: THE LOWER PRESSURES OF
1/4' MAX. THE WINDOW OR MULL SHALL GOVERN
SHIM
12 S.D.S. X 1 1/4" L.
1 AT 12' D.C. MAX.
NOTE:
1. ALL STEEL IN CONTACT WITH
ALUM. TO BE PAINTED OR PLATED.
2. METAL STRUCTURES:
A) STEEL : Fy a 36 KSI MIN.
(STEEL 18 GA. MIN. THICK - 0.0487
B) ALUMINUM 6063-T5 MIN.
(ALUM. 0.078" MIN. THICK)
PERIMETER WINDOW FRAME
SEALANT EXTERIOR E 1
METAL STRUCTURE ATTACHMENT DETAIL
z
oai
;
y
Z.
31i.a
ZLi