HomeMy WebLinkAboutAPPROVED, 20210331_NOTICE OF ACCEPTANCE (NOA)MIAMNDiADE MIAMI-DADE COUNTY s PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building Lawson Industries, Inc. 8501 NW 90 Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "4200/6200 Flange -Frame" Aluminum Fixed Window — L.M.I. APPROVAL DOCUMENT: Drawing No. L4200-6200-1201, titled "Series-4200-6200 Flange Frame Impact Fixed Window", sheets 1 through 5 of 5, dated 02/21/12, with revision D dated 04/10/20, prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami —Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 17-1212.13 and consists of this page I and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 20-0428.01 M MM 6DE CCK)N Y CIVExpiration Date: August 22, 2022 Approval Date: June 25, 2020 6/18/20 Page 1 Lawson Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 12-0307.06) 2. Drawing No. L4200-6200-1201, titled "Series-4200-6200 Flange Frame Impact Fixed Window", sheets 1 through 5 of 5, dated 02/21/12, with revision C dated on 11/01/17, prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No. 17-1212.13) B. TESTS 1. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an arch and a rectangular fin -frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-12-4010 and HETI-11-3363, both dated 03/05/12, signed and sealed by Rafael Droz—Seda, P.E. (Submitted under NOA No. 12-0307.06) 2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a rectangular, a circular arch and an elliptical arch fin -frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-09-2614 dated 09/04/09, HETI-09-2612 dated 09/02/09, HETI-09-2586 dated 07/10/09, HETI-09-2584 dated 07/10/09, HETI-09-2582 dated 07/10/09, and HETI-09-2580 dated 07/10/09, all signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 12-0307.06) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 along with marked -up drawings and installation diagram of a rectangular fin -frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-09-2613 dated 09/04/09, HETI-09-2611 dated 09/04/09, HETI-09-2585 dated 07/10/09, HETI-09-2581 dated 07/10/09 and HETI-09-2579 dated 07/10/09, all signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 12-0307.06) 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 along with marked -up drawings and installation diagram of a rectangular fin -frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-03-1778 dated 01/30/03, HETI-03-1779 dated 01/30/03 and HETI-03-1776 dated 01/30/03, all signed and sealed by Rafael Droz-Seda, P.E. (Submitted under NOA No. 03-0327.11) Manuel et0428 . Product Control Ee NOA No. 2 Expiration Date: August22 Approval Date: June 25, 2020 E-1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a rectangular, a circular arch and an elliptical arch fin -frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-03-1777 dated 01/30/03, HETI-03-1774A dated 01/30/03, and HETI-03-1774B dated 01/30/03, all signed and sealed by Rafael Droz-Seda, P.E. (Submitted under NOA No. 03-0327.11) 6. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 along with marked -up drawings and installation diagram of a circular arch fin —frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-02-1215 dated 04/08/02 and HETI-01-1193 dated 04/08/02, both signed and sealed by Hector Medina, P.E. (Submitted under NOA No. 02-0701.01) 7. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a rectangular, a circular arch and an elliptical arch fin -frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-02-1158 dated 04/08/02, HETI-01-1103 dated 02/12/02 and HETI-01-1098 dated 02/11/02, all signed and sealed by Hector Medina, P.E. (Submitted under NOA No. 02-070L 01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC, prepared by manufacturer, dated 03/01/12, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No. 12-0307.06) 2. Glazing complies with ASTM E1300-04/09 D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). Manuel Perez, P.E. Product Control Ex r NOA No. 2 28.0 Expiration Date: August 22, 2 Approval Date: June 25, 2020 E-2 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No.16-1117.01 issued to Kuraray America., Inc. for their "Trosifol® Ultraclear, Clear, and Color PVB Interlayers" dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America., Inc. for their "SentryGlas® (Clear and White) Interlayer" dated 06/25/15, expiring on 07/04/18. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. F. STATEMENTS 1. Statement letter of conformance to FBC 6a' Edition (2017) and of "no financial interest" dated 11/17/17, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No. 17-1212.13) 2. Statement letter dated 01/22/18 of the editorial drawing changes issued by Lawson Inc, signed by Nelson Erazo, Senior Design Engineer. (Submitted under NOA No. 17-1212.13) 3. Laboratory compliance letter for Test Reports No. HETI-09-2614 dated 09/04/09, HETI-09-2612 dated 09/02/09, HETI-09-2586 dated 07/10/09, HETI-09-2584 dated 07/10/09, HETI-09-2582 dated 07/10/09, HETI-09-2580 dated 07/10/09, HETI-09-2613 dated 09/04/09, HETI-09-2611 dated 09/04/09, HETI-09-2585 dated 07/10/09, HETI-09-2581 dated 07/10/09 and HETI-09-2579 dated 07/10/09, all issued by Hurricane Engineering & Testing, Inc., signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 12-0307.06) 4. Laboratory compliance letter for Test Reports No. HETI-124010 dated 03/05/12, HETI-11-3363 dated 03/05/12, HETI-03-1778 dated 01/30/03, HETI-03-1779 dated 01/30/03, HETI-03-1776 dated 01/30/03, HETI-03-1777 dated 01/30/03, HETI-03-1774A dated 01/30/03 and HETI-03-1774B dated 01/30/03, all issued by Hurricane Engineering & Testing, Inc., signed and sealed by Rafael Droz-Seda, P.E. (Submitted under NOA No. 12-0307.06) G. OTHERS 1. Notice of Acceptance No. 17-0531.05 issued to Lawson Industries, Inc. for their Series "4200/6200 Flange - Frame" Aluminum Fixed Window — L.M.I., approved on 08/17/17 and expiring on 08/22/22. Manuel Perez, P.E. Product Control Ea NOA No. 20- 28.01 Expiration Date: August 22, Approval Date: June 25, 2020 E-3 Lawson Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. L4200-6200-1201, titled "Series-4200-6200 Flange Frame Impact Fixed Window", sheets 1 through 5 of 5, dated 02/21/12, with revision D dated on 04/10/20, prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E.. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 5) Large Missile Impact Test per FBC, TAS 201-94 6) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 4200/6200 aluminum fixed window, glazed with'/I6" HS laminated glass, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-12021, dated 03/20/20, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 61h Edition (2017), prepared by manufacturer, dated 04/17/20, signed and sealed by Thomas J. Sotos, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. 2. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflez CP - Saflex and Saflez HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. Manuel Perez, P.E. Product Control Exa NOA No. 20- 28.01 Expiration Date: August 22, Approval Date: June 25, 2020 E-4 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6th Edition (2017), dated April 17, 2020, issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E. 2. Statement letter of no financial interest, dated April 17, 2020, issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E. 3. Proposal No. 19-1138 issued to Lawson Industries, Inc. by the Product Control Section, dated October 18, 2019, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 17-1212.13, issued to Lawson Industries, Inc. for their Series "4200/6200 Flange - Frame" Aluminum Fixed Window — L.M.I., approved on 02/01/18 and expiring on 08/22/22. Manuel PertP.E.'Product Control ExNOA No. 20-Expiration Date: August 2 Approval Date: June 25, 2020 E-5 SERIES-4200 / 6200 FIXED IMPACT WINDOW - FLANGE FRAME APPROVED WINDOW ELEVATIONS (L.M.IMPACT) VIN)OW HEIGHT WINDOW WIDTH OUARTER-ROUND WINDOW HEIGHT jIL.� HALF WIN HEIGHT LEG HT. ARCHED WINDOW VIDTN WINDOW WIDTH PICTURE WINDOW ELEVATION -ROUND TYPICAL ELEVATION V1mW HE0 �vlwnoW vinrH HEXAGON TYPWA ELEVATION WINDOW HEIGHT L.WINDOW WIDTH WINDOW HEIfiHT RECTANGULAR WINDOW WIDTH TYPICAL ELEVATION SQUARE PICTURE WINDOW FLVATION r— 0 WIN HEIGHT FULL ROUND TYPICAL ELEVATION WINDOW _ HEIGHT VI [D�OV HE OW LIJ HT. VM➢OV VIDTN SQUARES PICTURE WINDOW ELEVATION VI.. WIDTH RECTANGULAR TYPICAL ELINATION WIN0 HEIGHT WINDOW WnLj OVAL TYPICAL ELEVATION V1N� HE T LEG HT. I OV WINDOW HEIGHT WINDOW WIDTH t EGGED EYE BROW FLAATION VINDOV VI➢TH QUARTER -ROUND NATION WINDOW HEIGHT WIDOW W. OCTAGON TYPK& ELNATION ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN, CAN N VERIFIEDHA BY INSCRIBING PICTURE WINDOW SHAPE WITHIN A SQUARE OR RECTANGLE, AS SHOW IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES. PROVIDED PERIMETER FASTENERS ARE AS DESCRIBED HEREIN FOR SIZE AND SPACING. WINDOW HEIGHT WINDOW WIDTH 1 IPTI e W TYPICAL ELCMILON 74,000' WINDOW WIDTH 70.81 D.L. OP . 12' MAX, A TYP. 6 MA%. i AT C Lo �-iWN ., p a t7 /XX»LLAJA g D q�F1 i, i TYP. DRHERS AX. iYP. 76,000' WINI710W WIDTH S+FI a• .L. OPG. la' MAX. TYP. rDD z -Lj i1 rm 3 ii ' ii 12' MA%. TYP. V V I I VIV I TYPICAL ELEVATION TESTED UNIT EXT. 6. TNT, FALSE COLONIAL) MUNTINS ARE APPLIED V/ NOTE: W/ SILICONE AND ARE TYPICAL ELEVATION AT TESTED UNIT MAXIMUM GLASS AREA TESTED APPLIES AVAILABLE AS OPTIONAL. NOTE: TO GLASS TYPES: E. F, K AND L. - SEE MAXIMUM GLASS AREA TESTED APPLIES DESIGN LOAD CAPACITY TABLES ON TO GLASS TYPES: J - SEE DESIGN LOAD SHEET 4 FOR SIZE LIMITATIONS OF EACH CAPACITY TABLES ON SHEET 4. GLASS TYPE. WINDOWS ARE L.M. IMPACT MIAMI-DADS COUNTY APPROVED General Notes I SHUTTERS NOT REQUIRED 1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (2014-5th Edition & 2017-6th Edition) INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ) AND ASTM 1300-09. THIS PRODUCT IS IMPACT RESISTANT. (SHUTTERS NOT REQUIRED) 2.) WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE BUILDING RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH THE REQUIREMENTS OF F.H.C. & TO BE REVIEWED BY BUILDING OFFICIAL. 3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW SIZES ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.) . 4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO BE ENGINEERED ON A SITE SPECIFIC BASIS, UNDER SEPARATE APPROVAL AND TO BE REVIEWED BY BUILDING OFFICIAL. 5.) WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS TYPES, AND FOR USE WITH DOUBLE GLAZE LAMINATED INSULATED GLASS TYPES TABULATED HEREIN; (SEE SHEET p3 FOR GLASS TYPES AND SHEET #4 FOR MAX. DESIGN PRESSURES). 6.) WINDOWS WITH GLASS TYPES -B, C, F, OR G- INSTALLED ABOVE 304t. IN THE HVHZ, THE I.G. EXTERIOR LITE SHALL BE TEMPERED TO COMPLY WITH THE SMALL MISSILE IMPACT RESISTANCE REQUIREMENTS (FBC-Chapter 24 Section 2411.3.3.7). 7.) FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHEETS 2 & 5. 6.) EXT. & INT. FALSE COLONIAL MUNTINS ARE OPTIONAL & AND ARE APPLIED W/ SILICONE 9.) WOOD BUCKS IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED AND ANCHORED (BY OTHERS), PRIOR TO WINDOW INSTALLATION. (SEE SHEET #2 FOR DETAIL & NOTES) 10.) APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE MULLED UNITS. 11.) MULLING FIXED WINDOWS WITH OTHER TYPES OF MIAMI-DADE COUNTY APPROVED PRODUCTS USING A MIAMI-DADS COUNTY APPROVED MULLION IN BETWEEN ARE ACCEPTABLE BUT THE LOWER DESIGN PRESSURE FROM THE WINDOWS OR MULLION APPROVAL WILL APPLY YO THE ENTIRE MULLED SYSTEM. 12.) SEE SHEET # 5 FOR MULLION/METAL ATTACHMENT DETAILS & OPTIONS. 4,4`TY1Cf i➢NbAd� 014 S.M.S. W/ I I/4' MIN. EMBEDMENT INTO WGUR (SEE ELEVATION AT SHEET BI FOR MAX. FASTENER SPACING) 1/4• MAX. INTERIOR SHIN SPACE INTERIOR FINISH --- NOT BY LAWSON INDUSTRIES, INC. Li3•mm® EXT. GRADE BACK BEDDING TO BE APPLIED BEHIND WINDOW FRAME FLANGE BY INSTALLER <TYP.) <cuY+uiA4lY}JrtiiNTN-h4 .... ,•:{ wc�x+ue«u«wcu n ^ EXTERIOR .X ;,• :Ct L.N EXT. GRADE PEAIETER CAULKING NOT BY LAW= INDUSTRIES', TO BE APPLIED BY OTHERS C 1 IAO (TYP.) STUCCO OVER METAL LATH NAILED TO EXTERIOR GRADE PLYWOOD SHEATHING TD K SPECIFIED BY ARCHITECT OR G.C. (EXTERIOR FINISH BY OTHERS) MOT BY LAWSON INDUSTRIES, INC. WOOD FRAME INSTALLATION DETAIL WINDOW INSTALLATION NOTES: 1. THE WINDOW FRAME FLANGE TO BE BACK -BEDDED W/ AN EXT. GRADE CAULK THROUGHOUT THE ENTIRE PERIMETER OF FLANGE BY WINDOW INSTALLER (TYP.) 2. THE EXPOSED EXT. PERIMETER OF THE WINDOW FRAME TO BE CAULKED AND SEALED W/ AN APPROVED EXTERIOR GRADE CAULK BY OTHERS (TYPJ 3. WOOD BUCK SPECIFIC GRAVITY = 0.55 MIN. 4. CONCRETE COMPRESSIVE STRENGHT = 2Ks1 MIN. • WHEN THE GAP BETWEEN THE WINDOW FRAME AND THE BUCK OR MASONRY IS LESS THAN 1/8-, SHIMS ARE NOT REQUIRED. ANCHORS NOTE: ANCHORS TO BE R14 SMS OR WD. SCREWS INTO WOOD, OR 1/4' ITW BUILDEX TAPCONS or ELCO ULTRACON CONC. FASTENERS INTO CONCRETE (2KSI MIN.), WITH A MINIMUM OF 1 1/4' PENETRATION INTO WOOD OR CONC, AT 12' O.C. MAX. ■ TAPCON YIELD STRENGTH, Fy=l00Ksl ULTIMATE STRENGTH, Fu=125Ks) ALL WOOD BUCKS IN CONTACT WITH CONCRETE — (NOT BY LAWSON IND.) TO BE PRESSURE TREATED S 6 TO BE REVIEWED BY BLDG. OFFICIAL (TYP.) (SEE GENERAL NOTES AT SHEET 81) EXT. G CAULK EXT. GRADE CAULK --\ #14 S.M.S. W/ 1 I/4' MIN, EMBEDMENT INTO WOOD, (SEE ELEVATION AT SHEET Bl FOR MAX. FASTENER SPACING) SILICONE ADHESIVE �/ 10 BEDDING COMPOUND / I INTERIOR r-LAMINATED GLASS a II EXT, GRADE O EXTERIOR CAULK EXTERIOR GRADE — PERIMETER CAULKING 4—WINDOW FRAME WIDTH R14 S.M.S. W/ 1 1/4' 1/4' TAPCON W/ 1 1/4' MIN. EMBEDMENT INTO WOOD. MIN, EMBEDMENT INTO CONC, (SEE ELEVATION AT SHEET Bl (SEE ELEVATION AT SHEET 81 FOR MAX. FASTENER SPACING) FOR MAX. FASTENER SPACING) 1 1/4' NUN. ��, P • , . EMBEIBIENT ;Y. F '•,e . 6, > . A2 �•' :• : �' •,'a EXTERIOR GRADE PERIMETER CAULKING C EXTERIOR a MAX. 1IM YP EXTERIOR GRADE= PERIMETER CAULKING WOOD BUCKS A I b I <o ' 1/4' TAPCON W/ 1 1/4' M 0 I ") MIN. EMBEDMENT INTO CONC. (SEE ELEVATION AT SHEET #1 .1 � a FOR MAX. FASTENER SPACING) O q N ­l O d a Z o s/a% MtN I o W = � to x a 11/8, MIN. EDGE DISTANCE P.T WOOD BUCK NOT BY LAWSON IND. MUST SUSTAIN IMPOSED LOADS P' a e AEMBQDMENT d` SILICONE ADHESIVE BEDDING COMPOUND INTERIOR GLASS e.. • a y' INA' d' MBENET. ,. III cq i i O N i m I co C z O z m 6 M 4 V) o gig $ F o g 3 d i 0 LAMINATED INSULATED GLASS COMPOSITION TYPE B ITEM DESCRIPTION DETAIL (a) d/1L a)IY aaw 1 1/8' ANN. GLASS 2 0.090' SAFLEX PVB by Eastman Chemical Co. 3 1/8' ANNEALED GLASS 4 1/4' INSULATED AIR SPACE 5 CU 1/8' ANNEALED OR TEMPERED GLASS LAMINATED INSULATED GLASS COMPOSITION TYPE C ITEM DESCRIPTION I ETAIL 1 1/8' ANNEALED GLASS 3n6• ® w 2 0.090' SAFLEX PVB by Eastnan Chemlcal Co, 3 1/8' ANNEALED GLASS 4 1/4' INSULATED AIR SPACE 5 (a) 3,116' ANNEALED OR TEMPERED GLASS LAMINATED INSULATED GLASS COMPOSITION TYPE F ITEM DESCRIPTION ________._.IL ® v4•I_ T` -- - - - = 1 1/8' HEAT-STRENGHTENED GLASS 2 0.090' TROSIFOL PVH by Kuraray Americo, Inc. 3 4 1/8' HEAT-STRENGHTENED GLASS 1/4' INSULATED AIR SPACE 5 C-) 1/8' ANNEALED OR TEMPERED GLASS 1 LAMINATED INSULATED GLASS COMPOSITION TYPE G ITEM DESCRIPTION I DETAIL 1 1/8' HEAT-STRENGHTENED GLASS 2/16 ❑- - ;:L 2 0.090' TROSIFOL PVB by Kuraray America, Inc. ® 1/✓41 3 1/8' HEAT-STRENGHTENED GLASS - -� w 4 1/4' INSULATED AIR SPACE _ 5 C.) 3/16' ANNEALED OR TEMPERED GLASS LAMINATED INSULATED GLASS COMPOSITION TYPE L ITEM DESCRIPTION DETAIL I 3/16' 1 3/16' HEAT-STRENGHTENED GLASS 2 0.090' TROSIFOL PVB by Kuraray America, Inc. 3 4 3/16' HEAT-STRENGHTENED GLASS 1/4' INSULATED AIR SPACE ' w'' __ _T7 7 5 3/16' TEMPERED GLASS 1.) SEE SHEET 4 FOR DESIGN LOADS LOAD CAPACITY TABLES. 1�0 WINDOWS WITH GLASS TYPES "B, C, F. OR G" INSTALLED ABOVE 30 FT. IN THE HVHZ, THE I.G. EXTERIOR LITE SHALL BE TEMPERED TO COMPLY WITH THE SMALL MISSILE IMPACT RESISTANCE REQUIREMENTS (FBC-2014, Section 2411.3.3.7). 9 5 1: 12 'SILICONE OPTIONS', ---- ---- - DOW CORNING 899 __ SCHNEE-MDREHEAD 5731 _ _ _ _ _ _ _ _ TREMCO SPECTRUM 2 LAMINATED LAMINATED F INSULATED -0600• INSULATED 0600. GLAZING DEPTH GLAZING DEPTH LAMINATED ANSULATED GLASS TYPICAL GLAZING DETAILGLASS TYPICAL GLAZING DETAIL 5 18 LAMINATED GLASS COMPOSITION - TYPE A DIEM CLASS DESCRIPTION 1 1/8' ANNEALE➢ GLASS�R4 2 0.090' TROSIFOL PVH by Kuraray America, Inc.3 1/8' ANNEALED GLASS j 5 18 LAMINATED GLASS COMPOSITION - TYPE D ITEM GLASS DESCRIPTION I -__DETAIL - 1 0.�0• l I/8' HEAT-STRENGHTENED GLASS 2 0.090' TROSIFOL PVH by Kuraray America, Inc. 3 1/8' HEAT-STRENGHTENED GLASS 13 32 LAMINATED GLASS COMPOSITION - TYPE E ITEM GLASS DESCRIPTION DETAIL 1 3/16' HEAT-STRENGHTENED GLASS 2 0,090' SAFLEX PVB by Eastnan Chemical Co. 3 1/8• HEAT-STRENGHTENED GLASS 1 0.4�• 7 18 LAMINATED GLASS COMPOSITION - TYPE H ITEM CLASS DESCRIPTION DETAIL-� 1 3/16' ANNEALED GLASS _ _ a4sr I,.• 2 0,090' SAFLEX PVB by Eastman Chemic¢t Co. 3 3/16' ANNEALED GLASS 7 18 LAMINATED GLASS COMPOSITION - TYPE I ITEM GLASS DESCRIPTION DETAIL, 1 3/16' ANNEALED GLASS 3n6 _ :_-T 2 0.090' TROSIFOL PVB by c¢, In Kurnr¢y Amerlc. A. 3n6 = 1 3 3/16' ANNEALED GLASS 1 7 16 LAMINATED GLASS COMPOSITION - TYPE d ITEM GLASS DESCRIPTION DETAIL 1 3/16' HEAT-STRENGHTENED GLASS 3/16 _ a -0.160 2 0.090' SENTRYGLASS by Kurnray America, Inc. n6 3 3/16' HEAT-STRENGHTENE➢ GLASS 7 18 LAMINATED GLASS COMPOSITION - TYPE K ITEM CLASS DESCRIPTION DETAIL 1 3/16' HEAT-STRENGHTENED GLASS 3n6• ____ __ _ _ _ _� .0. 0. 1 2 0.090' TROSIFOL PVB by Kuraray America, Inc. 3 3/16' HEAT-STRENGHTENED GLASS SILICONE SCHNEE-MOREHEAD SM 5731 DOW CORNING 899 TREMCO SPECTRUM 2 LAMINATED s HI MONOLITHIC Ilp 1l�i 141;�i� GAZING STOP 0 CIRCULAR WOWS. LAMINATED 3 LAMINATED 4 MONOLITHIC MONOLITHIC 0.600' GLAZING DEPTH DEPTH GLAZING DEPTH 2 LAMINATED MONOLITHIC 'SILICONE OPTIONS' DOW CORNING 899 SCHNEE-MDREHEAD 5731 TREMCD SPECTRUM 2 0.600' GLAZING DEPTH En z 10 you Cs 1= e m 0 z � O m 0 C' g'v a o J Z c h U Ltd. N �.a+ 2 il-5 aoin. ! .. S t � Ca ro I o cq .4 N y C ca O .4 R6 M CO V O O a -91 i tit fj� gg rp y gQ� $ y 2 fR N x Ix xxx xxxx$xx xgxx xggxx x$ x$$$xxgggggggg$gggo, + O O v< m v x xx$xxxxxxxgxx xgg.....ggxx xggg%x$$$$$g$$$g$g + $,® Xx x%xxx xggxx xgxxXxx %$$%x xggxx xggxx S 8 + _ g xxxgxx x$xxxx$$xx% xggxx.. xgggxx xgggxxxxg$$gxgxxxxxxggxggop $ v Xg8xgxXgxg%%j,gg%%xgggNg%xX$Ngf°T$t°JI$NN$t°Tf°T$gg{TNg(°l,4°'iNYR'gNgNg$gt°T°Tt°TN$Nom q p q + T IN}I x x x x $ % % % $ x % x x $ six x % x $ $ $ % x x $ $ $ x x x $ $ $ $ x x P. $ $ $ $ g $ $ g $ g g $ $ g MIA g g o.T 5 (A D, to n ti x xxxxx xx$xx x$xxxxx w soxxxxxm xg$$xx x$$$xx$$$$$$$$$$$$$$$$$$$opm-� v w xx x xxxxxxgxxxxxgxxxxAx x xxx %xxx x� x g x x x x� ass. x x x� g g MIX m m? x g x x x x g$ g g O m H pS 9 8 .......gggxx xgx$xXx?�$-$gx $$$$$$$�- q xxxxXx %$xxx X$xxxxXxgg C! Z. N 1 O VV O N t o A a [VJ � fVT V 01 W V P V (Vn N N N m m V O D P w N N N UJi � O� v O� N V m 0 m V 00 �� qJD OJD � V g D m v 0 0 0 V V x $ $ $ X $ $ $ $ % N $ $ $ $ x x $ $ $ $ ONi $ x X % $ $ N $ $ $ $ $ $ N N $ x $ $ $ $ $ $ $ $ $ N $ N $ N $ to V N T x$$$xxg$$xx$$$$xxx$$$$$xxx$$$$$$ggg$gggxx$$xg$g$$ggg$$$$gggg$or 9 L f ^, z--W ox z 93 101 w(n DN � 1_ h4E o z g�K IN oodn„� o aw -0 to 0 z w ra d M N z m m? Y' Y"P `: POIY� YP Y'gW Y'P Y'� 1"� Y' �W_'_P -1 �_'� S ,', i s °A `y ^E yr3�'oo� 'Ir��log41-5im .yak? i OP = O xxxxxxxxggxxxgxxxg$$xx$gggg$gg gg$goa m v p xggxx.xxgxxxxggxxggg%xgggggg$g$g$gg�m + g x g g x x x x x$$ x x$ Io x x g$$ x x$$$$$$$ g$$$$$ pf1 T 8 xx$$gxxxxggggg$$p p a q N$$ 111a $$ $$ $g4®11.938 tNn $$$ $$ OO� a atg$N $a V, m. a $$ g$ ; 9 T o q I- IsIals x x Ix x $ $ $ X $ $ $ $ X $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ T Y fTl mw xggxxxxx$$$XX$$gx$$$$$$$$$$$$$g$g$$$oQm x gxxxx Hal- xxgx x$gxxggxmm�gxgggg$os a z xggxxx%xggXxggxxaggx,Nggmmx$$g$g$'v- V J N NNNm�m V N N Iv. N® JIl VV V V mC VN b OD VOo .V to mPP de00oaOmN i D 1Y ci 4 .� qq d pp qq q pqq q, mm p O a y x g$g$ X$gggggggggggxxxggggggggxxg g$ gxor ro T B. Comp6anae'r/ FM ,StA Eddlon (2014) and ASIM E1500-09 C. Cempugnce r/ 2077 FBC 6tA Edition `e �y 0. Revised to gwfify QSq.Fl. Mod" 90 L 1 VI' MEDLEY, F LORIDAT 33166 D l]E:E31 I C • PH No. (305) 696-8660 MANUFACTURER OF QUALITY ALUMINUM WINDOWS AND GLASS DOORS SERIES 4200 6200 FLANGE FRAME IMPACT FIXED WINDOW LAMINATED GLASS DESIGN PRESSURE CHARTS L4200-6200-1201 1— 4 OF 5 BILL OF MATERIALS ITEM PART / QUANTITY DESCRIPTION MATERIAL REMARKS 1 L-4201 2 FRAME HEAD/SILL/JAMB 6063-T6 - 2 L-7708 4 GLAZING BEAD (5/16" GLASS) 6063-T6 - 3 L-7708 4 GLAZING BEAD (3/8" & 13/32" GLASS) 6063-T6 - 4 L-7708 TRIMMED 4 GLAZING BEAD (7/16" GLASS) 6063-T6 - 5 L-7711 4 GLAZING BEAD (5/16" GLASS- INSULATED) 6063-T6 - 6 L-6211 4 GLAZING BEAD (7/16" GLASS - INSULATED) 6063-T6 - 7 #8 X 3/4" 2/ CORNER ASSEMBLY SCREWS - P.H. PHILLIPS 8 L-4204 AS REOD. GLAZING BEAD AT CIRCULAR WDWS. 6063-T5 - 9 VWS-004 AS REOD. GLAZING GASKET SOFT PVC - 10 + AS REDD. GLAZING SILICONE - 11 PL 75.6020 1 AS REOD. GLAZING SETTING BLOCK SOFT PVC 1/8" X 1/8" X 2" 12 812-25H-357 I AS REOD. "TruSeal" Oura Seal Swiggle Spacer 1/4" BLACK 1/4" AIR SPACE WINDOW FRAME EXTRUSION DETAILSD�TAI 2.643 310 281 .7B�-.850 TYP —7 040 —91 050 TYP 808 4�-t5D9 .773 FRAME HEAD/SILL/JAMB 2 GLAZING STOP (5/16" GLASS) 310 .850.040 � � 272 ,OS' O r.250 O50 050 TYP. TYP. .773 F- 173 3 GLAZING STOP 4 GLAZING STOP (7/16" GLASS) (3/8" & 13/32" GLASS) .310 O50 .850 oso TYP. L O50 5 684 INSULATED GLAZING STOP W/ 5/16" LAMINATED GLASS 6 eoo INSULATED GLAZING STOP W/ 7/16" LAMINATED GLASS .050 TYP. �1 II��UIJI 808 8 .466-" SUTACITEay P Kury Qy .Inc. GLAZING STOP (CIRCULAR WOW.) SEE MULLION APPROVALS FOR MULLION TYPE, 51ZE AND MAX. DESIGN PRESSURE LIMITATIONS, ALUMINUM MULLION - (ALUM. 0.078" MIN. THICK) NOTE: THE LOWER PRESSURES OF THE WINDOW OR MULL SHALL GOVERN INTERIOR FRAIIF MFAO r;,,re5 '/x' . s- Irw ® �.F.�Sll- HEAD \ \ FRAME JAMI 7 RECT. OR SQUARE WINDOWS ryppW$ TYPICAL CORNER CONSTRUCTIO CIR O CMITERR CORNERS O FRAME RADIUS RR JOINT FRAME END CORNER FRAME CORNER & JOINT DETAILS JOINT DETAIL SEALANT ' FRAME CORNERS, OR JOINTS SEALED WITH A COLORED SEALANT AND PERIMETER OF GLAZING BEAD WITH CLEAR SILICONE It 12 X 3/4' S,D,S, FLAT HEAD, PHILLIPS. AT 12' D.C. MAX. EXTERIOR EXTERIOR GRADE E2 — WINDOW FRAME PERIMETER CAULKING FRAME MULLING DETAIL SEE MULLION APPROVALS FOR MULLION TYPE, SIZE AND MAX. DESIGN PRESSURE LIMITATIONS. INTERIOR NOTE: THE LOWER PRESSURES OF 1/4' MAX. THE WINDOW OR MULL SHALL GOVERN SHIM 12 S.D.S. X 1 1/4" L. 1 AT 12' D.C. MAX. NOTE: 1. ALL STEEL IN CONTACT WITH ALUM. TO BE PAINTED OR PLATED. 2. METAL STRUCTURES: A) STEEL : Fy a 36 KSI MIN. (STEEL 18 GA. MIN. THICK - 0.0487 B) ALUMINUM 6063-T5 MIN. (ALUM. 0.078" MIN. THICK) PERIMETER WINDOW FRAME SEALANT EXTERIOR E 1 METAL STRUCTURE ATTACHMENT DETAIL z oai ; y Z. 31i.a ZLi