HomeMy WebLinkAboutTrefelner revised energy calcFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: Trefelner Residence
BuilderName:
Street: Roland Court
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL , 34951
PermitNumber:
Owner: ChaseTrefelner
Jurisdiction: St. Lucie County
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Types(1727.8 sgft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1344.50 ft2
3. Number of units, if multiple family
1
b. Frame -Wood, Adjacent
c. Frame - Wood, Exterior
R=11.0 280.00 ft2
R=20.0 103.33 ft2
4. Number of Bedrooms
3
d. N/A
R= ftZ
5. Is this a worst case?
No
11. Ceiling Types (1851.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1425.00 ft2
6. Conditioned floor area above grade (ft2)
1425
b. Roof Deck (Unvented)
R=20.0 426.00 ft2
Conditioned floorarea below grade (ft2)
0
c. N/A
R= ft2
7. Windows(174.9 sqft.) Description
Area
12. Ducts
R ftZ
a. U-Factor: Sgl, U=0.32
162.92 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 85
SHGC: SHGC=0.22
b. U-Factor: SgI, U=0.37
12.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
24.0 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
Area Weighted Average Overhang Depth:
1.583 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.220
a. Electric Strip Heat
17.0 COP:1.00
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1851.0 sgft.)
Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation
R=0.0 1425.00 ft2
b. Conservation features
b.FlooroverGarage
R=19.0 426.00ft2
None
c. N/A
R= ftZ
16.Credits
CF, Pstat
Glass/Floor Area: 0.123
Total Proposed Modified Loads: 52.05
CS
11�7
PASS
Total Baseline Loads: 56.94
1 hereby certify that the plans and specifications covered by
Review of the plans andlyT4
this calculation are in compliance with
the Florida Energy
specifications covered by this
Code.
calculation indicates compliances,,
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 3-25-2021
this building will be inspected for
O
compliance with Section 553,908
,
I hereby certify that this building, a designed, is in compliance
Florida Statutes.
with the Florida Energy odael
�
X
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 On for whole house.
3125/2021 2:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Trefelner Residence
Bedrooms: 3
Address Type:
Street Address
Building Type: User
ConditionedArea: 1425
Lot#
OwnerName: ChaseTrefelner
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
BuilderName:
RotateAngle: 0
Street:
Roland Court
Permit Office: St. Lucie County
CrossVentilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State, Zip:
Fort Pierce,
FamilyType: Detached
FL, 34951
New/Existing: New (From Plans)
Comment:
CLIMATE
V
Design Temp
tnt Design Temp
Heating
Design Daily Temp
DesignLocation
TMY Site 97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1851 17399.4
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infii ID
Finished Cooled
Heated
1 Bedroom2
146 1372.4 No
1
1
1
Yes
Yes
Yes
2 Bath
60 564 No
0
1
Yes
Yes
Yes
3 Bedroom3
174 1635.6 No
1
1
1
Yes
Yes
Yes
4 Hall
28 263.2 No
0
1
No
Yes
Yes
5 Dining
110 1034 No
0
1
Yes
Yes
Yes
6 Kitchen
132 1240.8 Yes
1
1
Yes
Yes
Yes
7 Living Room
355 3337 No
1
1
Yes
Yes
Yes
8 WIC
60 564 No
0
1
Yes
Yes
Yes
9 MasterBedroom
215 2021 No
1
1
1
Yes
Yes
Yes
10 Master Bath
72 676.8 No
0
1
Yes
Yes
Yes
11 Laundry
54 507.6 No
0
1
No
Yes
Yes
12 Hall
19 178.6 No
0
1
No
Yes
Yes
13 GAR
426 4004.4 No
0
0
1
Yes
No
No
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
Bedroom2 25 ft 0
146 ft2
----
1 0
0
2 Slab -On -Grade Edge Insulation
Bath 6 ft 0
60 ft2
----
1 0
0
3Slab-On-Grade Edge Insulation
Bedroom3 31 ft 0
174ft2
__--
1 0
0
4Slab-On-Grade Edge Insulation
Hall 1 ft 0
28ft2
----
1 0
0
3/25/2021 2:13 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood Carpet
5Slab-On-Grade Edge Insulation
Dining loft
0
110ft2
____
1
0
0
6Slab-On-Grade Edge Insulation
Kitchen 11 It
0
132ft2
----
1
0
0
7Slab-On-Grade Edge Insulation
Living Room 19ft
0
355ft2
----
1
0
0
8 Slab -On -Grade Edge Insulation
WIC 5 ft
0
60 ft2
__--
1
0
0
9Slab-On-Grade Edgelnsulation
MasterBedroom 31 ft
0
215ft2
_---
1
0
0
10Slab-On-Grade Edge insulation
Master Bath 6 ft
0
72 ft2
----
1
0
0
1lSlab-On-Grade Edge Insulation
Laundry 1 ft
0
54ft2
----
1
0
0
12SIab-On-Grade Edge Insulation
Hall 1 ft
0
19 ft2
_---
1
0
0
13FlooroverGarage
GAR ----
----
426 ft2
19
0
0
1
ROOF
j
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials
Area
Area
Color
Barr
Absor.
Tested
Tested
Insul.
(deg)
1 GableorShed
Metal 2056ft2
326ft2
Medium
N
0.6
No 0.9
No 20
18.43
ATTIC
v # Type
Ventilation Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Unvented
0
1951 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Unvented)
Bedroom2
0
Blown
146ft2
0.1
Wood
2 UnderAttic(Unvented)
Bath
0
Blown
60 ft2
0.1
Wood
3 UnderAttic(Unvented)
Bedroom3
0
Blown
174ft2
0.1
Wood
4 Under Attic(Unvented)
Hall
0
Blown
28 ft2
0.1
Wood
5 UnderAttic(Unvented)
Dining
0
Blown
110ft2
0.1
Wood
6 UnderAttic(Unvented)
Kitchen
0
Blown
132ft2
0.1
Wood
7 UnderAttic(Unvented)
LivingRoom
0
Blown
355ft2
0.1
Wood
8 UnderAttic(Unvented)
WIC
0
Blown
60 ft2
0.1
Wood
9 UnderAttic(Unvented)
MasterBedroom
0
Blown
215ft2
0.1
Wood
10 UnderAttic(Unvented)
MasterBath
0
Blown
72ft2
0.1
Wood
11 UnderAttic(Unvented)
Laundry
0
Blown
54ft2
0.1
Wood
12 UnderAttic(Unvented)
Hall
0
Blown
19W
0.1
Wood
13 UnderAttic(Unvented)
GAR
19
Batt
426 ft2
0.11
Wood
3/25/2021 2:13 PM EnergyGauge@) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing
Solar Below
0
_ 1
N
Exterior
Concrete Block- Int Insul Bedroom
4.1
13
0
9 4
121.3 ft'
0
0
0.4
0
2
E
Exterior
Concrete Block - Int Insul Bedroom2
4.1
12
0
9 4
112.0 ft2
0
0
0.4
0
3
N
Exterior
Concrete Block - Int Insul Bath
4.1
6
0
9 4
56.0 ft2
0
0
0.4
0
4
N
Exterior
Concrete Block- Int Insul Bedroom
4.1
15
0
9 4
140.0 ft2
0
0
0.4
0
5
S
Exterior
Concrete Block - Int Insul Bedroom 3
4.1
4
0
9 4
37.3 ft2
0
0
0.4
0
- 6
W
Exterior
Concrete Block- Int Insul Bedroom
4.1
12
0
9 4
112.0 ft2
0
0
0.4
0
_ 7
E
Exterior
Concrete Block- Int Insul Dining
4.1
10
0
9 4
93.3 ft2
0
0
0A
0
8
E
Exterior
Concrete Block- Int Insul Kitchen
4.1
11
0
9 4
102.7 ft2
0
0
0.4
0
9
W
Exterior
Concrete Block- Int InsulLiving Room
4.1
19
0
9 4
177.3 ft2
0
0
0.4
0
_ 10
E
Exterior
Concrete Block - Int Insul WIC
4.1
5
0
9 4
46.7 ft2
0
0
0.4
0
_ 11
E
Exterior
Concrete Block- Int InsLMasterBedroo
4.1
15
0
9 4
140.0 ft2
0
0
0.4
0
12
S
Exterior
Concrete Block - Int InsLMasterBedroo
4.1
15
0
9 4
140.0 ft'
0
0
0.4
0
13
W
Exterior
Concrete Block - Int InsLMasterSedroo
4A
1
0
9 4
9.3 ft2
0
0
0.4
0
_ 14
S
Exterior
Concrete Block - Int Insul Master Bath
4.1
6
0
9 5
56.5 ftz
0
0
0.4
0
_15
W
Garage
Frame -Wood Master Bath
11
12
9 4
112.0ftZ
0.23
0A
0
_16
W
Garage
Frame -Wood Laundry
11
9
9 4
84.0fF
0.23
0.4
0
_17
S
Garage
Frame -Wood LivingRoom
11
9
9 4
84.0ft2
0.23
0.4
0
i 18
W
Exterior
Frame - Wood GAR
20
20
8
5 0
103.3 ft2
0.23
0A
0
DOORS
#
Ornt
DoorType Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated LivingRoom
None
'39
3
8
24 ft2
2
W
Insulated Laundry
None
.46
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V/
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
E 2
Vinyl low-ESingle Yes
0.32
0.22
Y
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
2
N 3
Vinyl Low-ESingle Yes
0.37
0.22
Y
6.0 ft2
1 ft 7 in
1 ft 4 in
None
None
3
W 6
Vinyl Low-E Single Yes
0.32
0.22
Y
18.0 ft2
1 ft 7 in
1 ft 4 in
None
None
4
E 7
Vinyl Low-ESingle Yes
0.32
0.22
Y
48.0 ft2
1 ft 7 in
1 ft 4 in
None
None
5
E 8
Vinyl Low-ESingle Yes
0.32
0.22
Y
12.0 ft2
1 ft 7 in
1 ft 4 in
None
None
6
W 9
Vinyl Low-ESingle Yes
0.32
0.22
Y
36.0 ft2
1 ft 7 in
1 ft 4 in
None
None
7
W 9
Vinyl Low-E Single Yes
0.32
0.22
Y
18.5 ft'
1 ft 7 in
1 ft 4 in
None
None
8
E 11
Vinyl Low-ESingle Yes
0.32
0.22
Y
15.4 ft2
1 ft7 in
1 ft 4 in
None
None
9
S 14
Vinyl Low-ESingle Yes
0.37
0.22
Y
6.0 ft2
1 ft 7 in
1 ft 4 in
None
None
3/25/2021 2:13 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
FloorArea
CeilingArea
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
441 ft2
441 ft2
30 ft 9.4 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse
ProposedACH(50)
.000298
1116.2 61.24 114.97 .0963
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
CentralUnit/
Split
Single SEER:16 24 kBtu/hr cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
CompanyName
Collector Storage
System Model# Collector Model# Area Volume
FEF
None
None
ft2
DUCTS
j
V #
-- Supply —
Location R-Value Area
---- Return --- Air CFM 25
Location Area LeakageType Handler TOT
CFM25
OUT ON RLF
HVAC #
Heat Cool
1
Attic 6 85 f12
Attic
20 ft2 Proposed On Attic -- elm
0.0 cfm 0.00 0.50
1 1
3/25/2021 2:13 PM EnergyGauge® USA7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST RFPORT
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Cooling Feb
HeatinHi.n
Jan Feb
Venting
Mar
MarApr
H
A r
May
May]
Jun
Jun
Jut
([ Jul
Auge
Au[
Sep
Oct
E 3 OctMNov
Nov
[ j Dec
Xj Dec
Jan Feb
Mar
[X] Apr
(
May
[ ]Jun
[ Jul
[ Aug
[ j Se
[X] Oct
Nov
j Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
10
11
12
Cooling(WD) AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling(WEH) AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating(WEH) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3
Bedroom2
Default(8lbs/sq.ft.
ft2
ft
0.3
Bath
Default(81bs/sq.ft.
ft2
ft
0.3
Bedroom3
Default(8lbs/sq.ft.
ft2
ft
0.3
Hall 2
Default(8lbs/sq.ft.
ft2
ft
0.3
Dining
Default(8lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Living Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
MasterBedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8lbs/sq.ft.
ft2
ft
0.3
Laundry
Default(8lbs/sq.ft.
ft2
ft
0.3
Hall 1
Default 8lbs/s .ft.
0 ft2
0 ft
0.3
GAR
3/25/2021 2:13 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6