HomeMy WebLinkAbout6702 donlon rd faSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICANT: Vincent Cimino
AGENT: Atlantic Land Designs of the TC
PROPERTY ADDRESS: 6702 Donlon Rd Fort Pierce, FL 34951
LOT: 6
BLOCK: 134a
APPLICATION #:AP1470811
PERMIT #:56-SF-2043950
DOCUMENT # : FI 1593323
DATE PAID:03/02/2020
FEE PAID:660.00
RECEIPT #:56-PID-4302959
SUBDIVISION: Lakewood Park ID#: 1301-612-0390-000-6
CHECKED [X1 ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
l
l
1
1
l
1
1
1
1
TANK INSTALLATION
[011 TANK SIZE [11 1090.00 [21 483.00
[021 TANK MATERIAL Polypropylene
[031 OUTLET DEVICE
(041 MULTI -CHAMBERED [ Y N 1
[051 OUTLET FILTER Tuf-Tite EF-4
[061 LEGEND 1. 70-143-11 DC4
[071 WATERTIGHT
[081 LEVEL
[091 DEPTH TO LID
DRAINFIELD INSTALLATION
(101 AREA [11 384.88 [21
[111 DISTRIBUTION BOX
[121 NUMBER OF DRAINLINES
[131 DRAINLINE SEPARATION
[141 DRAINLINE SLOPE
[151 DEPTH OF COVER
[161 ELEVATION [ ABOVE /
[171 SYSTEM LOCATION
[181 DOSING PUMPS
[191 AGGREGATE SIZE
[201 AGGREGATE EXCESSIVE FINE;
[211 AGGREGATE DEPTH
FILL / EXCAVATION MATERIAL
[ 1 (221 FILL AMOUNT
( 1 [231 FILL TEXTURE
[ 1 [241 EXCAVATION DEPTH
[ 1 [251 AREA REPLACED
[ 1 [261 REPLACEMENT MATERIAL
Comments: Comments are on page 2.
2. 70-143-54SC4
SQFT
HEADER X
1. 4.00 2.
BELOW IBM 0.00
1.00
l
l
l
l
SETBACKS
[271 SURFACE WATER
[281 DITCHES
[291 PRIVATE WELLS
[301 PUBLIC WELLS
[311 IRRIGATION WELLS
[321 POTABLE WATER
[331 BUILDING FOUNDATIONS
[341 PROPERTY LINES
[351 OTHER
FILLED / MOUND SYSTEM
[361 DRAINFIELD COVER
[371 SHOULDERS
[381 SLOPES
[391 STABILIZATION
FT
FT
87 FT
FT
FT
40 FT
14 FT
10 FT
FT
ADDITIONAL INFORMATION
[ 1 [401
UNOBSTRUCTED AREA
[ 1 [411
STORMWATER RUNOFF
[ 1 [421
ALARMS
[ 1 [431
MAINTENANCE AGREEMENT
[ 1 [441
BUILDING AREA
[ 1 (451
LOCATION CONFORMS WITH SITE PLAN
[ 1 [461
FINAL SITE GRADING
[ 1 [471
CONTRACTOR (Benjamin Drew"s Plumbing
[ 1 [481
OTHER INFILTRATOR Quick4 Plus EQ36 LP
ABANDONMENT
[ 1 [491
TANK PUMPED
[ 1 [501
TANK CRUSHED & FILLED
CONSTRUCTION [ APPROVED r St. Lucie CHD
/ DISAPPROVED 1 ' Enviro ental Speci st II Ian J Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED 1: St. Lucie CHD
Environmental Sped P
III Brian J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
EH Database v 1.0.1 AP1470811 EID2043950
DATE: r)7/nrw9r)21
DATE: 03/29/2021
Page 2 of 3
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION #:AP1470811
PERMIT #:56-SF-2043950
DOCUMENT #:F11593323
DATE PAID:03/02/2020
FEE PAID:660.00
RECEIPT #:56-PID-4302959
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300
gpd.
New ST, filter, DT, liberty 1/3 hp pump and 2X8+2X9 long Trench DF installed. No violations, system ok to cover. Contractor
gotified by phone. Needs final inspection for filled system„alarm and final site grading.
Final system approved. Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1470811 EID2043950