Loading...
HomeMy WebLinkAboutSAVAGE CONSTRUCTION REVISION 2 S&S OC2PAGE 1/2 H G F E D C B A 8 7 6 5 4 3 2 1 H G F E D C B A 8 7 6 5 4 3 2 1 DOCUMENT PROPERTY OF A. ALLEN ENGINEERING INC. & A&G CONCRETE POOLS INC., DUPLICATION AND/OR DISTRIBUTION IN PART OR WHOLE WITHOUT WRITTEN CONSENT FROM THE OWNER(S) WILL BE PUNISHABLE UNDER AWCPA COPYRIGHTS LAWS. DECK DRAIN 72 ft. 7 in.4 ft.H H R R STEP H H H H H H H H H H H H H H H H H H H H H H H H H 22.5X40 POOL VAC LINE 6' DEEP TILED STEP EDGES 3.5' DEEP SKIMMER TILED BENCH EDGE 24 INCH RAISED RISER WALL TILED ALL THE WAY AROUND WITH TRAVERTINE COPING AND (2) 48 INCH SHEER DESCENT WATERFALL 48" SHEER DESCENT 48" SHEER DESCENT 8'X12' 24 INCH RAISED SPA WITH A 1 FOOT THICK SPA WALL, 3 TIERS OF 18 INCH BENCH SEATING, 3 LEVELS OF HYDRO THERAPY JETS, COLOR LED LIGHTING, 2 RETURN LINES, TILED SPILLWAY AND 1 STEP 41 ft.4 ft.18 ft. 8 in.12 ft.+6"31 ft.12 ft. 8 in. 9 ft. 11 in. 3" 3" 3" 2.5" 2.5" JET PUMP 1 RETURN 2.5" JET PUMP 2 RETURN 2.5" JET PUMP 3 RETURN 1" RS8 1" 2" RETURN LINE 2.5" SHEER DESCENT SUPPLY 1.5"1.5" 2.5" DECK JET SUPPLY 1.5" 1.5" 1.5" 1.5" 1" 1" 1"1.5" WATER FEATURE PUMP 2.5" 2"1" OVERFLOW LINE AARON H. ALLEN PE, FL REG. NO. 86620 FL A. ALLEN ENGINEERING LLC, CA NO. 33042 2367 7TH STREET, LA VERNE, CA 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES SEAL: BUILDER/JOB NAME: PERMIT NO.: DATE DRAWN: TBD 10/14/2020 DRAWN BY: CHECKED BY: APPROVED BY: SAVAGE ADDRESS:7300 RESERVE CREEK DRIVE JORDAN VANDUZER AARON H. ALLEN SCALE:¼” = 1' CITY:PORT SAINT LUCIE FL 34986 JOB INFORMATION MAIN DRAIN SKIMMER COLOR LED VACUUM LINE SYMBOL LEGEND DECO DRAIN EXISTING FACILITY CHANNEL DRAIN ELEVATION MARKER B BUBBLER JANDY UPLIGHTUL DOOR/WINDOW ALARM BABY BARRIER XX.X’ x REVISION DATE:3/25/2021 · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE 8880 GLADES CUT OFF ROAD PORT ST. LUCIE, FL 34986 CUSTOMER APPROVAL: REVISION JANDY IAQUALINK RS8 VERIFY EXACT LOCATION OF EQ. PAD WITH FIELD SUPERVISOR 30" CLEARANCE IN FRONT OF SUBPANEL AND 5' MIN. FROM POOL WALL EQ. LAYOUT NO SCALE DOOR AND WINDOW ALARMS BY HOMEOWNER F P1 SALT HE P2 P3 P4 P5 MAX. WIDTH: MIN. DEPTH: 22.5' SHAPE: FILL FROM EXCAVATION: TILE:FILTER: PUMP HP: LIGHTS: TRNFORM: MAIN DRAIN: SKIMMER: RETURNS: VALVED VAC LINE: DISCHARGE LINE: CHLORINATOR: HANDRAIL: DIVING BOARD: HEATER: VACUUM HEAD: VACUUM HOSE: LEAF SKIMMER: TREE / STUMP REMOVAL: REMOVE EXISITING CONCRETE: PUMP POOL PATIO: ELECTRICAL: POOL PATIO: EXISTING PATIO: DECK DRAIN: POOL CAPACITY: TURN-OVER RATE: TERMITE TREAT:BARRIER: MAX. LENGTH:40' 3.5'MAX. DEPTH:6' RECT HAUL ELEVATION:TBD INTERIOR FINISH:GEM CL460 POOL SPA POOL 3 COLOR LED SPA 1 POOL SPA POOL 1 SPA 3 1 POOL 4 SPA 2 JETS:POOL NA SPA 9PS INCL FILL LINE:NA TO GROUND FUSION 1400 NA LADDER:NA NA SLIDE:NA THERMEAU S125 HEAT PUMP INCL INCL INCL POLE: BRUSH: TEST KIT: INCL INCL INCL YES INCL SCREEN ENCLOSURE: ED’S ELECTRIC CONCRETE FLOCRETE INCL 6-HRS. INCL FENCE; D/W ALARMS NA MAX. WATER VELOCITY: MIN. SKIMMER FLOW: SURFACE AREA OF POOL: SPECIFICATIONS (3) 2HP PHPM 300 WATT 100 WATT NA PUMP MAKE PER FBC 4501.20 2.7HP JANDY V.S. FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011 24,319 GALLONS SPA CAPACITY:2,513 GALLONS 6 FPS FROM TRUNK 25 GPM 765 SQ FT PERIMETER OF POOL: 125 LN FT N/A TO 8FPS SUCTION LINES,10FPS MAX RETURN R R R R 1.5" 1.5" 1.5" 1.5" 2" 0 ft.2 ft. 4.8 in.4 ft.8 ft. 0" SPA 24" ABOVE DECK 16" WATER X X X X X X X X37 ft.RAIL FENCE: YES WALL +24" 18" WATER 20" WATER W/F PUMP 2.0 JEP JANDY DECK JETS (4) AA BB 3" FILTRATION PUMP ARTISTRY 1004S STAINLESS HANDRAIL MSHBLUL – MARLIN WITH SHADOW CENTERED ON FLOOR OF POOL H G F E D C B A 8 7 6 5 4 3 2 1 H G F E D C B A 8 7 6 5 4 3 2 1 MAX. WIDTH: MIN. DEPTH: 22.5' SHAPE: FILL FROM EXCAVATION: TILE:FILTER: PUMP HP: LIGHTS: TRNFORM: MAIN DRAIN: SKIMMER: RETURNS: VALVED VAC LINE: DISCHARGE LINE: CHLORINATOR: HANDRAIL: DIVING BOARD: HEATER: VACUUM HEAD: VACUUM HOSE: LEAF SKIMMER: TREE / STUMP REMOVAL: REMOVE EXISITING CONCRETE: PUMP POOL PATIO: ELECTRICAL: POOL PATIO: EXISTING PATIO: DECK DRAIN: POOL CAPACITY: TURN-OVER RATE: TERMITE TREAT:BARRIER: MAX. LENGTH:40' 3.5'MAX. DEPTH:6' RECT HAUL ELEVATION:TBD INTERIOR FINISH:GEM CL460 POOL SPA POOL 3 COLOR LED SPA 1 POOL SPA POOL 1 SPA 3 1 POOL 4 SPA 2 JETS:POOL NA SPA 9PS INCL FILL LINE:NA TO GROUND FUSION 1400 NA LADDER:NA NA SLIDE:NA THERMEAU S125 HEAT PUMP INCL INCL INCL POLE: BRUSH: TEST KIT: INCL INCL INCL YES INCL SCREEN ENCLOSURE: ED’S ELECTRIC CONCRETE FLOCRETE INCL 6-HRS. INCL FENCE; D/W ALARMS NA MAX. WATER VELOCITY: MIN. SKIMMER FLOW: SURFACE AREA OF POOL: SPECIFICATIONS (3) 2HP PHPM 300 WATT 100 WATT NA PUMP MAKE PER FBC 4501.20 2.7HP JANDY V.S. FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011 GENERAL NOTES: 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING. 17. PLANTER SPECIES SHALL BE SELECTED WITH NON-INVASIVE ROOT SYSTEMS (SPECIES SELECTION BY OTHERS). AARON H. ALLEN PE, FL REG. NO. 86620 FL A. ALLEN ENGINEERING LLC, CA NO. 33042 2367 7TH STREET, LA VERNE, CA 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES 24,319 GALLONS SPA CAPACITY:2,513 GALLONS 6 FPS FROM TRUNK 25 GPM 765 SQ FT PERIMETER OF POOL: 125 LN FT SEAL: BUILDER/JOB NAME: PERMIT NO.: DATE DRAWN: TBD 10/14/2020 DRAWN BY: CHECKED BY: APPROVED BY: SAVAGE ADDRESS:7300 RESERVE CREEK DRIVE JORDAN VANDUZER AARON H. ALLEN SCALE:¼” = 1' CITY:PORT SAINT LUCIE FL 34986 JOB INFORMATION N/A SECTION THRU POOL 1 AScale: NTS WALL THICKNESS REQ.4 AScale: NTS TYP. WALL SECTION & WELL PT.5 AScale: NTS POOL DRAIN TYP.6 AScale: NTS EQUIPOTENTIAL BOND GRID 7 AScale: NTS WATER BONDING 8 AScale: NTS ELECTRICAL SCHEMATIC 7 CScale: NTS HANDRAIL BONDING 7 BScale: NTS W.L. #8 SOLID COPPER BOND WIRE W/ APPR. CLAMPS (SEE NOTE 3) 8 GAUGE SOLID COPPER WIRE SOIL 18" MIN. (ENTIRE PERIMETER) NOTES: 1. MINIMUM 18" FROM ENTIRE EDGE OF POOL PERIMETER BURIED 4" TO 6" DEEP 2. INSTALL PER N.E.C. 2017 SEC. 680.26 (WHERE ADOPTED) 3. #8 SOLID COPPER BOND WIRE WITH APPROVED CLAMPS ON EACH SIDE OF POOL (4 TOTAL) DECK PER DETAIL A/5 ANSI-7/ANSI-158 EScale: NTS 7 EScale: NTS EQUIPMENT LAYOUT UNDERWATER LIGHT 8 BScale: NTS PUMP CURVES 7 HScale: NTS SHORING REQUIREMENTS 3 AScale: NTS SOIL EQUIPMENT PAD PB-2008 BONDING WIRE TO GRID VARIESNOTE: 1. PB-2008 TO BE INSTALLED NEAR OR UNDER EQUIPMENT PAD FROM POWER SUPPLY POOL FINISH APPROVED GROUND CLAMP CONTINUOUS BOND WIRE COMMON TO POOL STEEL, RAILS & EQUIPMENT 1" LIGHT CONDUIT WATER LEVEL NICHELESS UNDERWATER LIGHT 18" MIN.EXIST. FTGN. SOIL 3 ft. 6 ft. 9 ft.5 ft.4" WALL #3 REBAR @ 12" O.C.E.W.ANGLE OF REPOSENOTES: EXCAVATION INTO ANGLE OF REPOSE ALLOWED IF: 1. SHORING IS SUFFICIENT TO SECURE SOILS FROM EROSION/SETTLEMENT 2. NO UNDERMINING OCCURS UNLESS APPROVED BY ENGINEER 3. COMPACTION TEST PROVIDED AT C.O. 6" WALL #3 REBAR @ 12" O.C.E.W. 8" WALL #3 REBAR @ 12" O.C.E.W. 2"X4" @ 24" O.C. ½" PLYWOOD NOTE: 1. SHORING TO BE INSTALLED WHEN POOL SHELL IS CLOSER THAN 5 FT TO HOME, OR EXCEEDS THE ONE TO ONE RATIO OF THE ANGLE OF REPOSE EXIST. FTGN. SOIL < 5' OR 1:1 MAIN DRAIN SKIMMER COLOR LED VACUUM LINE SYMBOL LEGEND DECO DRAIN EXISTING FACILITY CHANNEL DRAIN ELEVATION MARKER B BUBBLER JANDY UPLIGHTUL DOOR/WINDOW ALARM BABY BARRIER XX.X’ DECK PER DETAIL A/5 x0 ft.2 ft. 4.8 in.4 ft.8 ft. REVISION DATE:3/25/2021 · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE TO 8FPS SUCTION LINES,10FPS MAX RETURN SWIMOUT CUT SECTION 8 HScale: NTS 20" MAX. 18" 8880 GLADES CUT OFF ROAD PORT ST. LUCIE, FL 34986 CUSTOMER APPROVAL: REVISION NOTE: 1. WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE DOCUMENT PROPERTY OF A. ALLEN ENGINEERING INC. & A&G CONCRETE POOLS INC., DUPLICATION AND/OR DISTRIBUTION IN PART OR WHOLE WITHOUT WRITTEN CONSENT FROM THE OWNER(S) WILL BE PUNISHABLE UNDER AWCPA COPYRIGHTS LAWS. TYP. FOOTER SECTION 2 BScale: NTS NOTE: 1. WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE #8 GROUND WIRE DECK PER DETAIL A/5 6"X6" TILE INTERIOR FINISH CONCRETE DECK WITH OVERPOUR COPING #3 @ 12" O.C.B.W. TO PUMP THREADED PLUG SECURED GRATE TOOLS REQUIRED FOR REMOVAL GRAVEL BED NOTES: 1. REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL 2. FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. 3. SLOPE DECK ¼” PER FOOT 4. 2500 PSI FIBER REINFORCED PUMP MIX 4" COMPACTED SOIL 8" (1) #5 OR (2) #3 REBAR(S) CUT SECTIONTOP VIEW 8" 8" Eq.VARIESEq.Eq. Eq. 4" RAIL FENCE: YES 3 P1 WF S 2 P2 4 5 HE 1 B V KEY: 1. 2" POOL RETURN LINE TO FIRST TEE 2. 2" RETURN TO SPA 3. 2" SKIMMER LINE 4. 1.5" VACUUM LINE 5. 2.5" MAIN DRAIN SUCTION LINE 6. 2.5" SPA MAIN DRAIN SUCTION LINE 7. 3" JET SUCTION 8. 2.5" RETURN TO SPA HYDRO JETS (1) 9. 3" JET SUCTION 10. 2.5" RETURN TO SPA HYDRO JETS (2) 11. 3" JET SUCTION 12. 2.5" RETURN TO SPA HYDRO JETS (3) 13. 3" MAIN DRAIN SUCTION LINE 14. 2.5" RETURN TO JANDY DECK JETS 15. 2.5" RETURN SHEER DESCENT WATERFALLS P1. 2.7HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT STRAINER P2. 2HP JANDY JET PHPM PUMP WITH W/APPR HAIR AND LINT STRAINER P3. 2HP JANDY JET PHPM PUMP WITH W/APPR HAIR AND LINT STRAINER P4. 2HP JANDY JET PHPM PUMP WITH W/APPR HAIR AND LINT STRAINER P5. 2 HP JANDY JEP VARIABLE SPEED PUMP W/APPR HAIR AND LINT STRAINER HE. THERMEAU S125 ELECTRIC HEAT PUMP F. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE (MUST HOLD 35 PSI FOR 30 MINUTES MINIMUM) W. 1.5" TO WASTE OR TO GROUND V. VALVES (TYP) B. PB-2008 WATER BONDING TO GRID (SEE DETAIL A/8) S. FUSION 1400 SALT SYSTEM PUMP CURVES Scale: NTS 6 G POOL/SPA DRAIN CERTIFICATION Scale: NTS 6 E 3" PLUMBING LINES FROM SUMP W/ 3" TEE UNBLOCKABLE CHANNEL DRAIN WITH 2.5" RETURN TO FIRST TEE NOTES: 1. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 (SEE CERT. OF COMPLIANCE) 2. APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE 3" SUCTION LINE TO PUMP MAX: 181 GPM / 8 FPS TO FILTRATION PUMPTO JET PUMP 2.5" SUCTION LINE TO PUMP MAX: 117 GPM / 8 FPS SPA DRAIN CERTIFICATION Scale: NTS 6 D SPA DRAIN CERTIFICATION Scale: NTS 5 B 7 8 6"X6" TILE DECK PER DETAIL A/5 #3 @ 12" O.C.B.W. STEEL-TEX FORM OR KRAFT WALL 6" 4-½” CHANNEL DRAIN STEP NOTES: 1. CHANNEL DRAIN GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQ. FOR REMOVAL 2. STEP 9" BELOW WATER LINE, MIN. 240 SQ. INCHES INTERIOR FINISH SPA BENCH HEIGHT VARIES 3 TIER BENCH SEATING 6 NOTES: 1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE. 2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) 5. INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10' AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL 6. POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE POOL 7. PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS PER HO-26 OF NFPA 70 S.P.S.T. TOGGLE SWITCH 100 AMP POOL PANEL W/(3) - #4 THHN CU WITHIN 1” ELECTRICAL CONDUIT W/ INTEGRAL TIME CLOCK FOR PUMPS, MOTOR, AND HEATER MANUAL MOTOR SWITCH VARIABLE SPEED PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUIT TIME CLOCK W.P. DISCONNECT JUNCTION BOX 12 VOLT TRANSFORMERS W.P. DISCONNECT SALT SYSTEM W/BUILT IN OVERLOAD SWITCH W/3-#10 THHN CU WITH-IN ½” CONDUIT JANDY THERAPY PLUS HP PUMP MOTOR W/ BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITHIN ½” MIN. CONDUIT HEATER (ELECTRIC HEAT PUMP) 2- #6 THHN, 1#10 GROUND, 1#10 NEUTRAL CU WITHIN 3/4” CONDUIT. (CONNECT TO 50 AMP, 2 POLE GFCI BREAKER POOL LIGHTS SEE SPECS FOR QUANT. (GFI NOT REQUIRED) SPA LIGHT SEE SPECS FOR QUANT. (GFI NOT REQUIRED) #8 SOLID CU GROUND WIRE TO EXISTING PANEL P3 9 10 P4 11 12 P5 1413 5 G PUMP CURVES Scale: NTS 3" PLUMBING LINES FROM SUMP W/ 3" TEE UNBLOCKABLE CHANNEL DRAIN WITH 2.5" RETURN TO FIRST TEE NOTES: 1. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 (SEE CERT. OF COMPLIANCE) 2. APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE 3" SUCTION LINE TO PUMP MAX: 181 GPM / 8 FPS TO FILTRATION PUMPTO WATER FEATURE PUMP 2.5" SUCTION LINE TO PUMP MAX: 117 GPM / 8 FPS STEP NOTES: 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. 4. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 5. DEPTH > 4' ADD (1) #3-6 INCH O.C.O.W NOTES: 1. (5.6.1) THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FEET TO THE POINT OF THE FIRST SLOPE CHANGE 2. (5.6.2) CHANGES IN SLOPE BETWEEN SHALLOW AND DEEP AREAS SHALL BE AT A MINIMUM WATER DEPTH OF 2 FEET 9 INCHES AND BE AT LEAST 6 FEET FROM THE SHALLOW END 3. (5.6.3) THE SLOPE OF THE FLOOR FROM THE POINT OF THE FIRST SLOPE CHANGE TOWARD THE DEEP END SHALL NOT EXCEED 1 FOOT IN 3 FEET 4. WALLS SHALL NOT SLOPE > 11 DEGREES 5. HAND HOLD TO BE INSTALLED WHERE DECK RAISED +6" ABOVE POOL 40'0 FLOOR SLOPES #3 STEEL @ 12" O/C E.W. WATERLINE TILE MAIN DRAIN 13' 6" 6'3'6" 4-½” 10" MIN. TREAD 3' 6' SPA JET DETAIL Scale: NTS 5 E REC PUMP = 2.7HP JANDY VARIABLE FLO PRO VARIABLE SPEED LOW SPEED – 36 GPM MAX HIGH SPEED = 117 GPM @ 48 TDH 3" SUCTION PIPE @ 117 GPM = 5.63 FT/SEC. (8 FT./SEC. MAX. – SUCTION LINES) 3" BRANCH PIPE @ 60 GPM = 4.13 FT./SEC. (6 FT./SEC. MAX. – PRESSURE LINES) 2.5" PRESSURE PIPE @ 117 GPM = 8.43 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM BACKWASH VALVE NO WATER FEATURE PUMP = 2.0HP JANDY JEP VARIABLE SPEED LOW SPEED – 30 GPM MAX HIGH SPEED = 147 GPM @ 37 TDH 3" SUCTION PIPE @ 147 GPM = 6.67 FT/SEC. (8 FT./SEC. MAX. – SUCTION LINES) 3" BRANCH PIPE @ 73 GPM = 3.9 FT./SEC. (6 FT./SEC. MAX. – PRESSURE LINES) 2.5" PRESSURE PIPE @ 147 GPM = 9.61 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM BACKWASH VALVE NO THERAPY PUMP = 2HP JANDY STEALTH PLUS PHPM LOW SPEED = 36 GPM MAX. HIGH SPEED = 147 GPM @ 44 TDH MAX. 3" SUCTION PIPE @ 147 GPM = 7.29 FT./SEC. (8FT./SEC. MAX. – SUCTION LINES) 2.5" PRESSURE PIPE @ 147 GPM = 7.99 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) JANDY THERAPY PLUS HP PUMP MOTOR W/ BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITHIN ½” MIN. CONDUIT JANDY THERAPY PLUS HP PUMP MOTOR W/ BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITHIN ½” MIN. CONDUIT VARIABLE SPEED PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUIT TIME CLOCK W.P. DISCONNECT NOTE: 1. STEEL REINFORCEMENT IN CONCRETE AGAINST EARTH SHALL HAVE A MINIMUM COVER OF 2" W/F PUMP 2.0 JEP JANDY IAQUALINK RS8 PAGE 2/2 SPA BENCH DETAIL Scale: NTS 5 C 15 H H 18 INCHESH H 20 INCHESH H 16 INCHESH H 20 INCHESBB AA