HomeMy WebLinkAboutSAVAGE CONSTRUCTION REVISION 2 S&S OC2PAGE 1/2
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
DOCUMENT PROPERTY OF A. ALLEN ENGINEERING INC. & A&G CONCRETE POOLS INC., DUPLICATION AND/OR DISTRIBUTION IN PART OR WHOLE WITHOUT WRITTEN CONSENT FROM THE OWNER(S) WILL BE PUNISHABLE UNDER AWCPA COPYRIGHTS LAWS.
DECK DRAIN
72 ft. 7 in.4 ft.H H
R
R
STEP
H
H H
H
H
H
H
H H
H
H
H H
H
H H
H
H H
H
H H
H
H H
22.5X40 POOL
VAC LINE
6' DEEP
TILED STEP EDGES
3.5' DEEP
SKIMMER
TILED BENCH EDGE
24 INCH RAISED RISER WALL TILED ALL THE WAY AROUND WITH
TRAVERTINE COPING AND (2) 48 INCH SHEER DESCENT
WATERFALL
48" SHEER DESCENT 48" SHEER DESCENT
8'X12' 24 INCH RAISED SPA WITH A 1 FOOT THICK SPA
WALL, 3 TIERS OF 18 INCH BENCH SEATING, 3 LEVELS
OF HYDRO THERAPY JETS, COLOR LED LIGHTING, 2
RETURN LINES, TILED SPILLWAY AND 1 STEP 41 ft.4 ft.18 ft. 8 in.12 ft.+6"31 ft.12 ft. 8 in.
9 ft. 11 in.
3"
3"
3"
2.5"
2.5" JET PUMP 1 RETURN
2.5" JET PUMP 2 RETURN
2.5" JET PUMP 3 RETURN
1"
RS8 1"
2" RETURN LINE
2.5" SHEER DESCENT SUPPLY
1.5"1.5"
2.5" DECK JET SUPPLY
1.5"
1.5"
1.5"
1.5"
1"
1"
1"1.5"
WATER
FEATURE
PUMP
2.5"
2"1" OVERFLOW LINE
AARON H. ALLEN PE, FL REG. NO. 86620 FL
A. ALLEN ENGINEERING LLC, CA NO. 33042
2367 7TH STREET, LA VERNE, CA 91750
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS AND SPECIFICATIONS COMPLY WITH
THE APPLICABLE MINIMUM BUILDING CODES
SEAL:
BUILDER/JOB NAME:
PERMIT NO.:
DATE DRAWN:
TBD
10/14/2020
DRAWN BY:
CHECKED BY:
APPROVED BY:
SAVAGE
ADDRESS:7300 RESERVE CREEK DRIVE
JORDAN VANDUZER
AARON H. ALLEN
SCALE:¼” = 1'
CITY:PORT SAINT LUCIE FL 34986
JOB INFORMATION
MAIN DRAIN
SKIMMER
COLOR LED
VACUUM LINE
SYMBOL LEGEND
DECO DRAIN
EXISTING FACILITY CHANNEL
DRAIN
ELEVATION MARKER
B BUBBLER
JANDY UPLIGHTUL
DOOR/WINDOW ALARM
BABY BARRIER
XX.X’
x
REVISION DATE:3/25/2021
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR
RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR
SUCTION ENTRAPMENT AVOIDANCE
8880 GLADES CUT OFF ROAD
PORT ST. LUCIE, FL 34986
CUSTOMER APPROVAL:
REVISION
JANDY IAQUALINK RS8
VERIFY EXACT
LOCATION OF EQ.
PAD WITH FIELD
SUPERVISOR
30" CLEARANCE IN FRONT
OF SUBPANEL AND 5' MIN.
FROM POOL WALL
EQ. LAYOUT
NO SCALE
DOOR AND WINDOW
ALARMS BY
HOMEOWNER
F
P1
SALT
HE
P2
P3
P4
P5
MAX. WIDTH:
MIN. DEPTH:
22.5'
SHAPE:
FILL FROM EXCAVATION:
TILE:FILTER:
PUMP HP:
LIGHTS:
TRNFORM:
MAIN DRAIN:
SKIMMER:
RETURNS:
VALVED VAC LINE:
DISCHARGE LINE:
CHLORINATOR:
HANDRAIL:
DIVING BOARD:
HEATER:
VACUUM HEAD:
VACUUM HOSE:
LEAF SKIMMER:
TREE / STUMP REMOVAL:
REMOVE EXISITING CONCRETE:
PUMP POOL PATIO:
ELECTRICAL:
POOL PATIO:
EXISTING PATIO:
DECK DRAIN:
POOL CAPACITY:
TURN-OVER RATE:
TERMITE TREAT:BARRIER:
MAX. LENGTH:40'
3.5'MAX. DEPTH:6'
RECT
HAUL
ELEVATION:TBD
INTERIOR FINISH:GEM CL460
POOL SPA
POOL 3 COLOR LED SPA 1
POOL SPA
POOL 1 SPA 3
1
POOL 4 SPA 2
JETS:POOL NA SPA 9PS
INCL FILL LINE:NA
TO GROUND
FUSION 1400
NA LADDER:NA
NA SLIDE:NA
THERMEAU S125 HEAT PUMP
INCL
INCL
INCL
POLE:
BRUSH:
TEST KIT:
INCL
INCL
INCL
YES
INCL
SCREEN ENCLOSURE:
ED’S ELECTRIC
CONCRETE FLOCRETE
INCL
6-HRS.
INCL FENCE; D/W ALARMS
NA
MAX. WATER VELOCITY:
MIN. SKIMMER FLOW:
SURFACE AREA OF POOL:
SPECIFICATIONS
(3) 2HP PHPM
300 WATT 100 WATT
NA
PUMP MAKE PER FBC 4501.20
2.7HP JANDY V.S.
FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011
24,319 GALLONS
SPA CAPACITY:2,513 GALLONS
6 FPS FROM TRUNK
25 GPM
765 SQ FT
PERIMETER OF POOL: 125 LN FT
N/A
TO 8FPS SUCTION LINES,10FPS MAX RETURN
R
R
R
R
1.5"
1.5"
1.5"
1.5"
2"
0 ft.2 ft. 4.8 in.4 ft.8 ft.
0"
SPA 24" ABOVE DECK
16"
WATER
X
X
X
X X
X X
X37 ft.RAIL FENCE: YES
WALL +24"
18"
WATER
20"
WATER
W/F PUMP 2.0 JEP
JANDY DECK
JETS (4)
AA
BB
3"
FILTRATION PUMP
ARTISTRY 1004S STAINLESS
HANDRAIL
MSHBLUL – MARLIN WITH SHADOW
CENTERED ON FLOOR OF POOL
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
MAX. WIDTH:
MIN. DEPTH:
22.5'
SHAPE:
FILL FROM EXCAVATION:
TILE:FILTER:
PUMP HP:
LIGHTS:
TRNFORM:
MAIN DRAIN:
SKIMMER:
RETURNS:
VALVED VAC LINE:
DISCHARGE LINE:
CHLORINATOR:
HANDRAIL:
DIVING BOARD:
HEATER:
VACUUM HEAD:
VACUUM HOSE:
LEAF SKIMMER:
TREE / STUMP REMOVAL:
REMOVE EXISITING CONCRETE:
PUMP POOL PATIO:
ELECTRICAL:
POOL PATIO:
EXISTING PATIO:
DECK DRAIN:
POOL CAPACITY:
TURN-OVER RATE:
TERMITE TREAT:BARRIER:
MAX. LENGTH:40'
3.5'MAX. DEPTH:6'
RECT
HAUL
ELEVATION:TBD
INTERIOR FINISH:GEM CL460
POOL SPA
POOL 3 COLOR LED SPA 1
POOL SPA
POOL 1 SPA 3
1
POOL 4 SPA 2
JETS:POOL NA SPA 9PS
INCL FILL LINE:NA
TO GROUND
FUSION 1400
NA LADDER:NA
NA SLIDE:NA
THERMEAU S125 HEAT PUMP
INCL
INCL
INCL
POLE:
BRUSH:
TEST KIT:
INCL
INCL
INCL
YES
INCL
SCREEN ENCLOSURE:
ED’S ELECTRIC
CONCRETE FLOCRETE
INCL
6-HRS.
INCL FENCE; D/W ALARMS
NA
MAX. WATER VELOCITY:
MIN. SKIMMER FLOW:
SURFACE AREA OF POOL:
SPECIFICATIONS
(3) 2HP PHPM
300 WATT 100 WATT
NA
PUMP MAKE PER FBC 4501.20
2.7HP JANDY V.S.
FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011
GENERAL NOTES:
1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND
WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS.
2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL
WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE
CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS)
COMPRESSIVE STRENGTH.
3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F.,
OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING
CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN.
4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40.
5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F.
APPROVAL.
6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES.
7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES.
SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES.
PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR.
8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS
NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER
DISPOSAL SYSTEM.
9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF
THE SUCTION LINE
10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A
MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE.
11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA"
HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL
CODE- LATEST EDITION.
12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL,
LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS,
DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED
TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER
THAN #8 COPPER.
13. NO OVERHEAD OPEN WIRE OVER POOL WATER.
14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED
3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED.
15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT
SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY
LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY.
16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO
PREVENT UNDERMINING.
17. PLANTER SPECIES SHALL BE SELECTED WITH NON-INVASIVE ROOT
SYSTEMS (SPECIES SELECTION BY OTHERS).
AARON H. ALLEN PE, FL REG. NO. 86620 FL
A. ALLEN ENGINEERING LLC, CA NO. 33042
2367 7TH STREET, LA VERNE, CA 91750
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS AND SPECIFICATIONS COMPLY WITH
THE APPLICABLE MINIMUM BUILDING CODES
24,319 GALLONS
SPA CAPACITY:2,513 GALLONS
6 FPS FROM TRUNK
25 GPM
765 SQ FT
PERIMETER OF POOL: 125 LN FT
SEAL:
BUILDER/JOB NAME:
PERMIT NO.:
DATE DRAWN:
TBD
10/14/2020
DRAWN BY:
CHECKED BY:
APPROVED BY:
SAVAGE
ADDRESS:7300 RESERVE CREEK DRIVE
JORDAN VANDUZER
AARON H. ALLEN
SCALE:¼” = 1'
CITY:PORT SAINT LUCIE FL 34986
JOB INFORMATION
N/A
SECTION THRU POOL 1
AScale: NTS
WALL THICKNESS REQ.4
AScale: NTS
TYP. WALL SECTION & WELL PT.5
AScale: NTS
POOL DRAIN TYP.6
AScale: NTS
EQUIPOTENTIAL BOND GRID 7
AScale: NTS
WATER BONDING 8
AScale: NTS
ELECTRICAL SCHEMATIC 7
CScale: NTS
HANDRAIL BONDING 7
BScale: NTS
W.L.
#8 SOLID COPPER BOND
WIRE W/ APPR. CLAMPS
(SEE NOTE 3)
8 GAUGE SOLID COPPER WIRE
SOIL
18" MIN.
(ENTIRE PERIMETER)
NOTES:
1. MINIMUM 18" FROM ENTIRE EDGE OF POOL PERIMETER BURIED 4" TO 6" DEEP
2. INSTALL PER N.E.C. 2017 SEC. 680.26 (WHERE ADOPTED)
3. #8 SOLID COPPER BOND WIRE WITH APPROVED CLAMPS ON EACH SIDE OF POOL (4 TOTAL)
DECK PER DETAIL A/5
ANSI-7/ANSI-158
EScale: NTS
7
EScale: NTS
EQUIPMENT LAYOUT
UNDERWATER LIGHT 8
BScale: NTS
PUMP CURVES 7
HScale: NTS
SHORING REQUIREMENTS 3
AScale: NTS
SOIL
EQUIPMENT PAD
PB-2008
BONDING WIRE
TO GRID VARIESNOTE:
1. PB-2008 TO BE INSTALLED NEAR OR UNDER EQUIPMENT PAD
FROM POWER SUPPLY
POOL FINISH
APPROVED GROUND CLAMP
CONTINUOUS BOND WIRE
COMMON TO POOL STEEL,
RAILS & EQUIPMENT
1" LIGHT CONDUIT
WATER LEVEL
NICHELESS
UNDERWATER
LIGHT 18" MIN.EXIST. FTGN.
SOIL
3 ft.
6 ft.
9 ft.5 ft.4" WALL #3
REBAR @ 12"
O.C.E.W.ANGLE OF REPOSENOTES:
EXCAVATION INTO ANGLE OF REPOSE ALLOWED IF:
1. SHORING IS SUFFICIENT TO SECURE SOILS FROM EROSION/SETTLEMENT
2. NO UNDERMINING OCCURS UNLESS APPROVED BY ENGINEER
3. COMPACTION TEST PROVIDED AT C.O.
6" WALL #3
REBAR @ 12"
O.C.E.W.
8" WALL #3
REBAR @ 12"
O.C.E.W.
2"X4" @ 24" O.C.
½" PLYWOOD
NOTE:
1. SHORING TO BE INSTALLED WHEN POOL
SHELL IS CLOSER THAN 5 FT TO HOME,
OR EXCEEDS THE ONE TO ONE RATIO OF
THE ANGLE OF REPOSE EXIST. FTGN.
SOIL
< 5' OR 1:1
MAIN DRAIN
SKIMMER
COLOR LED
VACUUM LINE
SYMBOL LEGEND
DECO DRAIN
EXISTING FACILITY CHANNEL
DRAIN
ELEVATION MARKER
B BUBBLER
JANDY UPLIGHTUL
DOOR/WINDOW ALARM
BABY BARRIER
XX.X’
DECK PER DETAIL A/5
x0 ft.2 ft. 4.8 in.4 ft.8 ft.
REVISION DATE:3/25/2021
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR
RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR
SUCTION ENTRAPMENT AVOIDANCE
TO 8FPS SUCTION LINES,10FPS MAX RETURN
SWIMOUT CUT SECTION 8
HScale: NTS
20" MAX.
18"
8880 GLADES CUT OFF ROAD
PORT ST. LUCIE, FL 34986
CUSTOMER APPROVAL:
REVISION
NOTE:
1. WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE
DOCUMENT PROPERTY OF A. ALLEN ENGINEERING INC. & A&G CONCRETE POOLS INC., DUPLICATION AND/OR DISTRIBUTION IN PART OR WHOLE WITHOUT WRITTEN CONSENT FROM THE OWNER(S) WILL BE PUNISHABLE UNDER AWCPA COPYRIGHTS LAWS.
TYP. FOOTER SECTION 2
BScale: NTS
NOTE:
1. WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE
#8 GROUND WIRE
DECK PER DETAIL A/5
6"X6" TILE
INTERIOR
FINISH
CONCRETE DECK WITH
OVERPOUR COPING
#3 @ 12" O.C.B.W.
TO PUMP
THREADED
PLUG
SECURED GRATE
TOOLS REQUIRED
FOR REMOVAL
GRAVEL
BED
NOTES:
1. REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN
& ATTACH AUX. PUMP LINE WHEN EMPTYING POOL
2. FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @
6" O.C.
3. SLOPE DECK ¼” PER FOOT
4. 2500 PSI FIBER REINFORCED PUMP MIX
4"
COMPACTED SOIL
8"
(1) #5 OR (2) #3 REBAR(S)
CUT SECTIONTOP VIEW
8"
8"
Eq.VARIESEq.Eq.
Eq.
4"
RAIL FENCE: YES
3
P1 WF
S
2
P2
4 5
HE
1 B
V
KEY:
1. 2" POOL RETURN LINE TO FIRST TEE
2. 2" RETURN TO SPA
3. 2" SKIMMER LINE
4. 1.5" VACUUM LINE
5. 2.5" MAIN DRAIN SUCTION LINE
6. 2.5" SPA MAIN DRAIN SUCTION LINE
7. 3" JET SUCTION
8. 2.5" RETURN TO SPA HYDRO JETS (1)
9. 3" JET SUCTION
10. 2.5" RETURN TO SPA HYDRO JETS (2)
11. 3" JET SUCTION
12. 2.5" RETURN TO SPA HYDRO JETS (3)
13. 3" MAIN DRAIN SUCTION LINE
14. 2.5" RETURN TO JANDY DECK JETS
15. 2.5" RETURN SHEER DESCENT WATERFALLS
P1. 2.7HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT
STRAINER
P2. 2HP JANDY JET PHPM PUMP WITH W/APPR HAIR AND LINT STRAINER
P3. 2HP JANDY JET PHPM PUMP WITH W/APPR HAIR AND LINT STRAINER
P4. 2HP JANDY JET PHPM PUMP WITH W/APPR HAIR AND LINT STRAINER
P5. 2 HP JANDY JEP VARIABLE SPEED PUMP W/APPR HAIR AND LINT
STRAINER
HE. THERMEAU S125 ELECTRIC HEAT PUMP
F. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE
(MUST HOLD 35 PSI FOR 30 MINUTES MINIMUM)
W. 1.5" TO WASTE OR TO GROUND
V. VALVES (TYP)
B. PB-2008 WATER BONDING TO GRID (SEE DETAIL A/8)
S. FUSION 1400 SALT SYSTEM
PUMP CURVES
Scale: NTS
6
G
POOL/SPA DRAIN CERTIFICATION
Scale: NTS
6
E
3" PLUMBING
LINES FROM
SUMP W/ 3" TEE
UNBLOCKABLE CHANNEL DRAIN
WITH 2.5" RETURN TO FIRST TEE
NOTES:
1. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B.
ASME/ANSI 112.19.8-2007 (SEE CERT. OF COMPLIANCE)
2. APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR
RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR
SUCTION ENTRAPMENT AVOIDANCE
3" SUCTION LINE TO PUMP
MAX: 181 GPM / 8 FPS
TO FILTRATION PUMPTO JET PUMP
2.5" SUCTION LINE TO PUMP
MAX: 117 GPM / 8 FPS
SPA DRAIN CERTIFICATION
Scale: NTS
6
D
SPA DRAIN CERTIFICATION
Scale: NTS
5
B
7 8
6"X6" TILE
DECK PER DETAIL A/5
#3 @ 12" O.C.B.W.
STEEL-TEX FORM OR
KRAFT WALL
6"
4-½”
CHANNEL DRAIN
STEP
NOTES:
1. CHANNEL DRAIN GRATE SHALL BE SECURED IN PLACE
SO THAT TOOLS ARE REQ. FOR REMOVAL
2. STEP 9" BELOW WATER LINE, MIN. 240 SQ. INCHES
INTERIOR
FINISH
SPA BENCH HEIGHT VARIES 3
TIER BENCH SEATING
6
NOTES:
1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE.
2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S)
3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER.
4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B)
5. INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10'
AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL
6. POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE
POOL
7. PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS
PER HO-26 OF NFPA 70
S.P.S.T. TOGGLE
SWITCH
100 AMP POOL PANEL
W/(3) - #4 THHN CU WITHIN 1”
ELECTRICAL CONDUIT W/ INTEGRAL TIME
CLOCK FOR PUMPS, MOTOR, AND HEATER MANUAL MOTOR SWITCH
VARIABLE SPEED PUMP MOTOR
W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN
CU WITH-IN ½” CONDUIT
TIME
CLOCK
W.P. DISCONNECT
JUNCTION BOX 12 VOLT TRANSFORMERS
W.P. DISCONNECT
SALT SYSTEM W/BUILT IN OVERLOAD SWITCH
W/3-#10 THHN CU WITH-IN ½” CONDUIT
JANDY THERAPY PLUS HP PUMP MOTOR W/
BUILT-IN OVERLOAD SWITCH W/3- #10 THHN
CU WITHIN ½” MIN. CONDUIT
HEATER (ELECTRIC HEAT PUMP)
2- #6 THHN, 1#10 GROUND, 1#10 NEUTRAL CU WITHIN 3/4”
CONDUIT. (CONNECT TO 50 AMP, 2 POLE GFCI BREAKER
POOL LIGHTS SEE
SPECS FOR QUANT.
(GFI NOT REQUIRED)
SPA LIGHT SEE SPECS
FOR QUANT.
(GFI NOT REQUIRED)
#8 SOLID CU GROUND WIRE
TO EXISTING PANEL
P3
9 10
P4
11 12
P5
1413
5
G
PUMP CURVES
Scale: NTS
3" PLUMBING
LINES FROM
SUMP W/ 3" TEE
UNBLOCKABLE CHANNEL DRAIN
WITH 2.5" RETURN TO FIRST TEE
NOTES:
1. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B.
ASME/ANSI 112.19.8-2007 (SEE CERT. OF COMPLIANCE)
2. APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR
RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR
SUCTION ENTRAPMENT AVOIDANCE
3" SUCTION LINE TO PUMP
MAX: 181 GPM / 8 FPS
TO FILTRATION PUMPTO WATER FEATURE
PUMP
2.5" SUCTION LINE TO PUMP
MAX: 117 GPM / 8 FPS
STEP NOTES:
1. TREAD IS MIN. OF 10" WIDE.
2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED.
3. ALL STEPS TO BE SOLID GUNITE 4000 PSI.
4. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER
OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY
5. DEPTH > 4' ADD (1) #3-6 INCH O.C.O.W
NOTES:
1. (5.6.1) THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1
FOOT IN 7 FEET TO THE POINT OF THE FIRST SLOPE CHANGE
2. (5.6.2) CHANGES IN SLOPE BETWEEN SHALLOW AND DEEP AREAS SHALL BE AT A MINIMUM WATER DEPTH OF 2 FEET 9
INCHES AND BE AT LEAST 6 FEET FROM THE SHALLOW END
3. (5.6.3) THE SLOPE OF THE FLOOR FROM THE POINT OF THE FIRST SLOPE CHANGE TOWARD THE DEEP END SHALL NOT
EXCEED 1 FOOT IN 3 FEET
4. WALLS SHALL NOT SLOPE > 11 DEGREES
5. HAND HOLD TO BE INSTALLED WHERE DECK RAISED +6" ABOVE POOL
40'0
FLOOR SLOPES
#3 STEEL @ 12" O/C E.W.
WATERLINE TILE
MAIN DRAIN
13'
6"
6'3'6"
4-½”
10" MIN.
TREAD
3'
6'
SPA JET DETAIL
Scale: NTS
5
E
REC PUMP = 2.7HP JANDY VARIABLE FLO PRO
VARIABLE SPEED
LOW SPEED – 36 GPM MAX
HIGH SPEED = 117 GPM @ 48 TDH
3" SUCTION PIPE @ 117 GPM = 5.63 FT/SEC.
(8 FT./SEC. MAX. – SUCTION LINES)
3" BRANCH PIPE @ 60 GPM = 4.13 FT./SEC.
(6 FT./SEC. MAX. – PRESSURE LINES)
2.5" PRESSURE PIPE @ 117 GPM = 8.43 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM
BACKWASH VALVE NO
WATER FEATURE PUMP = 2.0HP JANDY JEP VARIABLE SPEED
LOW SPEED – 30 GPM MAX
HIGH SPEED = 147 GPM @ 37 TDH
3" SUCTION PIPE @ 147 GPM = 6.67 FT/SEC.
(8 FT./SEC. MAX. – SUCTION LINES)
3" BRANCH PIPE @ 73 GPM = 3.9 FT./SEC.
(6 FT./SEC. MAX. – PRESSURE LINES)
2.5" PRESSURE PIPE @ 147 GPM = 9.61 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM
BACKWASH VALVE NO
THERAPY PUMP = 2HP JANDY STEALTH PLUS PHPM
LOW SPEED = 36 GPM MAX.
HIGH SPEED = 147 GPM @ 44 TDH MAX.
3" SUCTION PIPE @ 147 GPM = 7.29 FT./SEC.
(8FT./SEC. MAX. – SUCTION LINES)
2.5" PRESSURE PIPE @ 147 GPM = 7.99 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
JANDY THERAPY PLUS HP PUMP MOTOR W/
BUILT-IN OVERLOAD SWITCH W/3- #10 THHN
CU WITHIN ½” MIN. CONDUIT
JANDY THERAPY PLUS HP PUMP MOTOR W/
BUILT-IN OVERLOAD SWITCH W/3- #10 THHN
CU WITHIN ½” MIN. CONDUIT
VARIABLE SPEED PUMP MOTOR
W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN
CU WITH-IN ½” CONDUIT
TIME
CLOCK
W.P. DISCONNECT
NOTE:
1. STEEL REINFORCEMENT IN CONCRETE AGAINST EARTH SHALL HAVE A MINIMUM COVER OF 2"
W/F PUMP 2.0 JEP
JANDY IAQUALINK RS8
PAGE 2/2
SPA BENCH DETAIL
Scale: NTS
5
C
15
H
H
18 INCHESH
H
20 INCHESH
H
16 INCHESH
H
20 INCHESBB
AA