HomeMy WebLinkAboutNotice of Acceptance (3) i MIAMI•DADE REVIEWED FOR CODE C® NIIAMITROL COUNTY COMPLIANCE e PRODUCT CONTROL SECTION ST. LUCIE COUNTY 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND EC O C SOURCES(RER) Miami,FL 33175 BOARD AND CODE ADMINISTRATION DI D � T(786)315-2590 F(786)315 2599 NOTICE OF ACCEPTANCE (NOA) ww w.rniamjdade.14ov/eco1 WinDoor,Inc. 104 Triple Diamond Blvd. North Venice,FL 34275 � ®gIY SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER '- Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will iucur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series"360"Aluminum Single Hung Window—L.M.I. APPROVAL DOCUMENT: Drawing No. SH360LM-NOA, titled Series "360" Alum Single Hung WDW. (L.M.I./S.M.I.), sheets 1 through 14 of 14, dated 01/10/20, prepared by manufacturer, signed and sealed by Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, stal e, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has:been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement�of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure,to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises#20-0213.05 PLA consists of this page 1 and evidence pages E-1,as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao,P.E. I NOA No.20-0722.20 MIAMI®ouNTY Expiration Date: May 05,2025 12 11/05/2020 November 05,i 2020 Approval Date: , Page 1 i WinDoor,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED i A. DRAWINGS 1. Manufacturer's die drawings and sections (See NOA #20-0722.13) 2. Drawing No. SH360LM-NOA, titled Series "360"Alum Single Hung WDW. (L.M.I./S.M.I.), sheets 1 through 14 of 14, dated 01/10/20,prepared by the manufacturer, signed and sealed by Lynn Miller,P.E. C B. TESTS (See NOA #20-0722.13) C. CALCULATIONS (See NOA #20-0722.13) i D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS (See NOA #20-0722.13) F. STATEMENTS (See NOA #20-0722.13) G. OTHERS 1. Private labeling agreement between WinDoor, Inc. and CGI Windows and Doors,Inc. document in conformance of RER guideline dated 09/12/2018. (Submitted under NOA #I8-1001.19) 2. Notice of Acceptance No. 20-0213.05, issued to WinDoor, Inc. for their Series "360" Aluminum Single Hung Window—L.M.I., approved on 03/05/2020 and expiring.on 05/05/2025. 3. Notice of Acceptance No. 20-0722.13, issued to CGI Windows and Doors,Inc. for their Series "360"Aluminum Single Hung Window—L.M.I., approved on 10/08/2020 and expiring on 05/05/2020. j{/ A Sifang Zhao!P.E. Product Control Examiner NOA No.20-0722.20 Expiration Date: May 05,'2025 Approval Date: November 05,12020 E-1 i � I General Window Sections 11 1/2" (typ. flange) 10 FRi 17 16 1 12 15 SE' 607 THE SHl Opernbte Sash Bet z to to iA 50s 4 H c O 19 I (tvP)m 1 18 C.� s0 M 14 M 609 (to 602 602 - e x t e r i o r 1 20 21 J B Daylight. Daylight JT a (typ) (typ) 3 9/16" Opng. Opng. 3 -9/16" O 4 SEE SHEEM 6 & 8 FOR GLAM OPTIONS Window Width Window Width T (Optional) 0 7 INSTRUCTIONS FOR USING CAPACITY CHARTS: STEP 1 DETERMINE THE REQUIRED DESIGN PRESSURES FOR A GIVEN WINDOW OPENING, STEP 2 DETERMINE THE CAPACITY OF THE WINDOW o SIZE/CONFIGURATION/GLASS TYPE FROM CHARTS ON s _ SHEETS 5 AND 7. iv 00 DETERMINE THE ANCHOR CAPACITY FROM SHEET 11 03 O a� n 1 2 STEP 3 FOR SINGLE OPENINGS, APPLICABLE TO ANCHORS TYPE .o N +, m A. B OR C SHOWN ON SHEETS 9 AND 10. a x Addl. Anchc 3 STEP 4 IF ALUMINUM BUCKS ARE USED, VERIFY THE BUCK m INSTALLATION CAPACITY FROM SHEET 13. At Mtg. Stile End STEP 5 FOR UNCLIPPED MULLED WINDOWS DETERMINE Reqd. For Higher Load 9 MULLION/MULLION ANCHORS CAPACITY FOR 1.X4 TUBE (if Applicable MULLION FROM CHARTS ON SHEET 12. See Chart On Sheet 1 STEP 6 IF ALUMINUM BUCKS ARE USED DETERMINE BUCK For Capacit a ANCHORING REQUIREMENTS FROM CHARTS ON SHEET 14. O s (Optional) 5 4 THE LOWEST SELECTED VALUE APPLY TO THE INSTALLATION SERIES '360� ALUMINUM SINGLE HUNG 11PIND0� AND MUST EQUAL OR EXCEED THE REQUIRED DESIGN PRESSURES OBTAINED FROM STEP 1. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE C( vT (Optional) (Required) o ( P ) OF S.H./S.H. OR SINGLE HUNG WITH OTHER MIAMI—DADE I g B &O APPROVED WINDOWS USING MIAMI—DADE COUNTY APPROVE IN BETWEEN. ---— ----- __-- LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION AF WILL APPLY TO ENTIRE SYSTEM.THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPL' REQUIREMENTS OF THE 2017 (6TH EDITION)/2020 (7TH EDTI o BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE O tD n 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, FRAME ANC SEE SHEEP O O OPTIONAL 1 GLASS TYP' 11 17 16 i i2 15 10 628 Operable Sash Below Ira fi 0 `O 4 9 N tO 1 ,11 - M 19 S 6'0 c (tYp to 602 e x t e r i o r 1 20 21 Daylight +, o, (typ) (tvp) 3 Opening 3 „ -c c rn•c C <SEE SHEETS 6:& 8 FOR MSS OPTIONS Window Width 00 = o rn •- _ �I� L to 2 ' N M 1° Addl. Anchor 0 I R At Mtg. Stile Ends c x Regd. For Higher Loads (if Applicable) Glazing at Insulated Laminated See Chart On Sheet 11 F9 For Capacity +� rn 4 no (Optional) 5 6 ! C` 1 r. I n Bill of Materials ITEM PART # QUANTITY DESCRIPTION MATERIAL MANF./SUPPLIER REMARK 1 W23201 NG AS REQD. WOOL PILE WITH CENTER SOFT FIN (GRAY) PILE ULTRAFAB/SCHLEGEL 2 CGI-612P AS REQD. PLASTIC BUMPER GUIDE PVC PROTOTYPE PLASTIC EXTRUSIONS CONTINU( 3 #146-4 2 WEEP HOLE COVER NYLON BUILDERS PLASTIC COMPANY 4 N/A AS REQD. GLAZING GLASS VARIES 5 N/A 1 COMPLETE SCREEN ALUM/MESH 6 CGI-615C 1 OR 2 COMBINATION EGRESS LOCK AND LIFT/PULL ZINC CUSTOM CASTING 110 WDI & 616C ATTACHED W/(2) #8 X 5/8" FH SMS 2 ® WDI A30700 & OPTIONAL SWEEP LOCK & KEEPER (replaces 1 ® WDI 7 C30705 1 OR 2 item 6) ATTACHED W/(4) #6 X 5/8" FH SMS ZINC TRUTH HARDWARE OR EQUIV. 2 ® WDI 8 18-11—XX-100 1 OR 2 LIFT/PULL ZINC TRUTH HARDWARE OF EQUIV. 1 ® WDI 20 WDI . 9 CGI-614C 2 TIE DOWN BLOCK ZINC CUSTOM CASTING 10 VARIES 2 BALANCES (B&T OR SPIRAL) VARIES VARIES BOTH BA - - - - 11 CGI_-617P. _. _ 2 _ -BALANCE _COVER_ _ - _ PVC PROTOTYPE PLASTIC EXTRUSIONS LOCATED 1.2——C-GI-61.8P 2 VENT STOP PVC PROTOTYPE PLASTIC EXTRUSIONS LOCATED 14 CGI-613P 2 FIXED VENT SHIM PVC PROTOTYPE PLASTIC EXTRUSIONS LOCATED 15 CGI-619P 2 TOP GUIDE AT OPERABLE VENT NYLON CUSTOM CASTING 9 C nn1 nnn•l n m1 -rT•Ai1 PH IIMr /l R, A ^M1 MA nl 1-- .wi — — . ram.—T .— I3.572 -3.597 n N nIC , p � o 'o u� u� L— N OR N d O N O CV N p N O 080 cj J. _T u 3.452 —I 600—Frame Head 601—Frame Sill 602—Frame Jamb 6063—T6 6063—T6 6063—T6 1.326 � f---1.701 0 T 1.520. O N N N to N O .0$5 ;° .080 N 080 Iq L 701 Nto 1 }I_ N M .090 ~+ .832-I 604—Horiz. Rail 605—Fixed Intick. 606—Moving Intick 607—Side Rail 609—GI2 6063—T6 6063—T6 6063—T6 ' �2.126 VENT 1.326 1.326--i •.088 .070 1.777—1 1.632 .085J tE0 I 2.507 2.040 JI 2.507 .080 1.632 3.134 1.326 .062 .940 .070 902--I 1.701 1.6513" I- 629—GI; 606, 625—Honz. Rail 626—Fixed Intick. 627—Moving Intick 628—Side Rail 6063—T6 6063—T6 6063—T6 For Glass T .135 .325 � nnA 1/8" Ann. Glass 1/8" HS Glass 090" Interlayer .090" Interlayer SentryGlas SentryGlas By 'Kuraray America, Inc.' By 'Kurargy America, Inc.' Supplemental Test .075" Interlayer .075" Interlayer Air Infiltration - WatE -Saflex CP With PET Core Saflex CP With PET Core By 'Eastman Chemical Co. By 'Eastman Chemical Co.' Test Type and ME 100" Interlayer .100" Interlayer Saflex HP Clear or Color Glass Saflex HP Clear or Color Glass Air Infiltration Test (ASTi By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' {, ® 1.57 psf pressured m 1/8" Ann. Glass m 1/8" HS Glass ® 6,24 psf pressure d cV N- Silicone N N Silicone GE-1200 o GE-1200 Water-Leakage'Test--(AST r GE-2000 GE-2000 DOW-791 DOW-791 without waterba g DOW=983 DOW-983 with waterbai DOW-995 DOW-995 23 At 1/4 Points On Utes 23 At 1/4- Points On Utes Forced Entry Resistance Wider Than 36" Wider Than 36" (ASTM F588 & Grade 10 Glass Type 'T' Glass Type 'Y' 5/16" Nominal Glass 5/16" Nominal Glass Annealed/Annealed HS/HS EQUAL LITES WINDOWS EQUAL LITES WINDOWS EQUAL LITES WINDOWS DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY _ PSF DESIGN LOAD CAPACITY - PSF WINDOW DIMS. GLASS TYPE T GLASS TYPE '2' WMOW DIMS. GLASS TYPE 'I'GLASS TYPE '2' WINDOW DIMS. GLASS TYPE 'I'GLASS TYPE '2' WIDTH HEIGHT EXT.(+) 1 NT.(-) EXT.(+)I i NT.(-) WIDTH HEIGHT EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) WIDTH HEIGHT EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) 24" 100.0 210.0 100.0 210.0 24" 100.0 161.9 100.0 210.0 19-1/8" 100.0 210.0 100.0 210.0 30" 100.0 210.0 100.0 210.0 30" 100.0 118.8 100.0 120.0 26-1/2" 26" 100.0 210.0 100.0 210.0 32" 100.0 210.0 100.0 210.0 32" 100.0 111.9 100.0 120.0 37" 100.0 210.0 100.0 210.0 36" �" 100.0 180.0 100.0 210.0 360 96" 100.0 101.5 100.0 120.0 1 53-1/8" 100.0 1 171.1 100.0 210.0 42 100.0 144.0 100.0 210.0 42" 85.4 85.4 100.0 120.0 19-1/8" 100.0 210.0 100.0 •210.0 48" 100.0 120.0 100.0 200.0 48" 76.2 76.2 100.0 120.0 26-1/2" 38-3/8" 100.0 210.0 100.0 210.0 54" 100.0 102.9 100.0 171.4 54" 68.9 68.9 100.0 120.0 37" 100.0 197.2 100.0 210.0 24" 100.0 210.0 100.0 210.0 24" 100.0 142.4 100.0 21D.0 53-1/8" 100.0 124.1 100.0 206.9 30" 100.0 199.7 100.0 210.0 30" 100.0 102.2 100.0 120.0 1 19-1/8" 100.0 210.0 100.0 210.0 32" 100.0 190.3 100.0 1 210.0 32" " 944.9 94.9 100.0 120.0 26-1/2" 100.0 210.0 100.0 210.6 36" 60" 100.0 164.3 100.0 210.0 36" 108 85.9 85.9 100.0 120.0 37„ 50-5/8 100.0 168.3 100.0 210.0 42" 100.0 128.0 100.0 210.0 42" 75.3 75.3 100.0 120.0 53-1/8" 100.0 101.2 100.0 168.7 48" 100.0 104.7 100.0 120.0 48" 68.6 68.6 100.0 126.0 19-1/8" 100.0 210.0 100.0 210.0 54" 88.6 88.6 100.0 120.0 24" 100.0 120.0 100.0 120.0 26-1/2" 63" 100.0 207.5 100.0 210.0 __24'___ 100.0 _201.1_ . 100.0__ _210.0._ 30' 903 90.7 100.0 120.0 37" 100.0 154.9 100.0 210.0 30" 100.0 162.1 100.0 210.0 32" 120" 83.6 83.6 100.0 120.0 53-1/8" 88.1 88.1 100.0 120.0 32" 100.0 167.6 100.0 210.0 36" 75.9 75.9 100.0 120.0 19-178" 100.0 210.0 100:0 2i0.0 36" 72" 100.0 150.7 100.0 210.0 42" 1 66.4 i 66.4 100.0 120.0 26-1/2" 72" 100.0 is 1.5 100.0 210M 42" 100.0 120.0 100.0 120.0 37" 100.0 146.8 100.0 210.0 48" 96.0 96.0 100.0 120.0 53-1/8" B2.0 82.0 1 100.0 120.0 NOTE: .090" Interlayer GLASS CAPACITIES ON THIS SHEET ARE -Sey 'Ku las B BASED ON ASTM E1300-09 (3 SEC. GUSTS) By Kuraray America, Inc.' AND FLORIDA BUILDING COMMISSION .075" interlayer DECLARATORY STATEMENT DCA05-DEC-219 3/16 HS Saflex CP With PET Core By 'Eastman Chemical Co.' 100" Interlayer Saflex HP Clear or Color Glass EQUAL LITES WINDOWS By 'Eastman Chemical Co.' DESIGN LOAD CAPACITY - PSF 3/16" HS WINDOW DIMS. GLASS TYPE 'S' GLASS TYPE 'SA' GLASS TYPE '4' GLASS TYPE '4A' r i��r Silicone GE-1200 WIDTH HEIGHT EXT.(+) 1NT.(-) EXT.(+) 1NT.(-) EXT.(+) 1NT.(-) EXT.(+) 1NT.(-) GE-2000 24" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 209.0 DOW-791 bow-983 - -- 30" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 209.0 DOW-995 32" 100.6 210.0 100.0 210.0 100.0 210.0 100.0 209.0 23 At 1/4 Points On Utes 36" 48" 100.0 210.0 1 100.0 210.0 100.0 210.0 100.0 1 203:0 Glass Type 113" Wider Than 36" 42" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 171.0 Sent" Interlayer - SentryGlcs 48" 100.0 200.0 100.0 200.0 100.0 200.0 100.0 148.0 1/8�� HS By 'Kuraray America, Inc.' 54" 1 100.0 171.4 100.0 171.4 100.0 171.4 100.0 131..0 3/$„ Air Space 075" Interlayer 1/8" H.S. GLASS Saflex CP With PET Core 3 8 24" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 209..0 OR By 'Eastman Chemical Co.' / 30" 100.0 210.0 1 100.0 210.0 100.0 210.0 100.0 1 200.0 1/8" TEMP. GLASS .100" Interlayer 1/8" AP 32" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 188.0 Saflex HP Clear or Color Glass 36" 60" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 156.0 By 'Eastman Chemical Co: 1/8" TEA . XL EDGE SPACER 1/$" HS 42" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 135.0 ST. STEEL BY 'CARDINAL! rnra Silicone XL EC 48" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 117.0 GE-1200 DURASEAL BY 'QUANEX' ST. STEEL BY 54" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 101.0 OR GE-2000 24" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 205.0 SUPER SPACER BY 'QUANEX' DOW-791 DOW-983 DURASEAL 8 30" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 155.0 DOW-995 23 SUPER SPACER 8 32" " 100.0 210.0 100.0 191.2 100.0 210.0 100.0 147.0 Glass Type »4�, At 1/4 Points All Sizes 36" 72 100.0 210.0 100.0 198:4 100.0 210.0 100.0 137.0 42" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 119.0 EQUAL LITES WINDOWS 48" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 102.0 DESIGN LOAD CAPACITY - PSF 54" 100.0 120.0 100.0 1.20.0 100.0 120.0 88.5 88.5 WINDOW DIMS. GLASS TYPE 'S' GLASS TYPE 'SA' GLASS TYPE '4' LASS TYPE '4A' NOTE: TO QUALIFI 24" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 180.0 WIDTH HEIGHT EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) THE EXTER 30" 100.0 210.0 100.0 210.0 100.0 210.0 1OQ.0 136.0 19-1/8" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 210.0 AND "LLA I (INSTALLATI; 32" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 1 129.0 26-1/2" 26" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 210.0 36" 84" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 117.0 37" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 210.0 42" 100.0 120.0 100.0 120.0 1 100.0 120.0 100.0 105.0 53-1/8*1 100.0 1 210.0 100.0 1 210.0 100.0 210.0 100.0 210.0 48" 100.0 120.0 100.0 120.0 100.0 120.0 923 92.7 19-1/8" 100.0 210.0 100.0 210.0 100.0 1 210.0 f 00.0 1 210.0 54" 100.0 120.0 100.0 120.0 100.0 120.0 80.4 80.4 26-1/2" 38-3/8" 100.0 210.0 100.0 210.0 100.0 1 210.0 100.0 210.0 24" 1.00.0 210.0 100.0 210.0 100.0 210.0 100.0 157.0 37" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 210.0 30" 100.0 f20.0 100.0 120.0 100.0 120.0 100.0 117.0 53-1/8" 100.0 206.9 100.0 206.9 100:0---206:9--100.0----180.0- - - - -32" -100.0-1-20:0-100.0-120:0-100:0-120:0--100.0--109.0--19-1/8 - 100.0--210.0__100.0 - --210.0_100.0__21.0.0_-100.0 _2.1.0._0_ 36" 96" 100.0 120.0 100.0 1 120.0 100.0 120.0 100.0 102.0 26-1/2" 50-5/8" 100.0 210.0 1 100.0 210.0 100.0 210.0 100.0 1 210.0 42" 100.0 120.0 100.0 120.0 100.0 120.0 90.8 90.6 37" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 183.0 48" 100.0 120.0 100:0 120.0 100.0 120.0 80.9 83.7 53-1/8" 100.0 168.7 100.0 168.7 100.0 168.7 100.0 123.0 1/8" Ann_ Glass 1/8" HS Glass Sent Interlayer ry .090" Interlayer Supplemental Test By 'Kuraray America, Inc.' SentryGlasBy 'Kuraray America, Inc.' Air Infiltration' - Wat( .075" Interlayer .075" Interlayer Saflex CP With PET Core Saflex CP With PEr Core Test Type and Me By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' .100" Interlayer .100" Interlayer Air Infiltration Test (AST Saflex HP Clear or Color Glass Saflex HP Clear or Color Glass ® 1.57 psf pressure d By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' ;t 1/8" Ann. Glass ,-°�_� 06.24 psf pressure d m m 1/8" HS Glass y Silicone N N Silicone Water Leakage Test (ASl GE-1200 \ o GE-1200 GE-2000 GE-2000 without waterba_ DOW-791 DOW-791 with waterba . DOW-983 DOW-983 DOW-995 DOW-995 Forced Entry Resistance 23 At 1/4 Points On Utes 23 At 1/4 Points On Lites (ASTM F588 & Grade 1 C Wider Than 36" Wider Than 36" Glass Type "1 " Glass Type '2" 5/16" Nominal Glass 5/16" Nominal Glass Annealed/Annealed HS/HS UNEQUAL LITES WINDOWS (ORIEL) UNEQUAL LITES WINDOWS (ORIEL) DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY - PSF WINDOW DIMS. TOP VENT GLASS TYPE T GLASS TYPE 02' WINDOW DIMS. TOP VENT GLASS TYPE T GLASS TYPE '2' WIDTH HEIGHT HEIGHT EXT.(+) 1NT.(-) EXT.(+) 1NT.(-) WIDTH HEIGHT HEIGHT EXL(+) INT.(-) EXr.(+) TNT-(-) 24" 100.0 161.9 100.0 210.0 19-1/8" 100.0 210.0 100.0 210.0 30" 100.0 118.8 100.0 120.0 26-1/2" 96„ 100.0 138.5 100.0 210.0 32" 100.0 111.9 100.0 120.0 37" (MAX.) 99.3 99.3 1 100.0 120.0 36" (6" Q" 100.0 101.5 10D.0 120.0 53-1/8" 69.8 69.8 100.0 120.0 42" 85.4 85.4 100.0 120.0 19-1/8" 100.0 210.0 100.0 210.0 48" 76.2 76.2 100:0 120.0 26-1/2" 108" 54" 100.0 120.0 100.0 120.0 54" M9 68.9 100.0 120.0 37" (MAX') 03.6 83.6 100.0 120.0 24" 100.0 142.4 100.0 210.0 19-1/8" 100.0 210.0 100.0 210.0 30" 100.0 102.2 1 100.0 120.0 26-1/2" 120" 60" 100.0 108.6 100.0 1 120.0 32" 94.9 94.9 100.0 120.0 37" (MAX') 73.7 73.7 100.0 120.0 36" (MAX.).)8 54" 85.9 85.9 100.0 120.0 19-1/8" 100.0 210.0 100.0 210.0 42" 75.3 75.3 100.0 120.0 26-1/2" 120" 66" 99.5 99.5 100.0 120.0 48" 68.6 68.6 10.0.0 120.0 37" (MAX') 65.7 65.7 100.0 120.0 24" 100.0 12D.0 100.0 120.0 19-1/8" 120" 72" 100.0 210.0 100.0 210.0 30" 90.7 90.7 1OD.0 120.0 26-1/2" (MAX.) 93.9 93.9 100.0 120.0 32" 120" 60" - 83.6 83.6 100.0 120.0 19-1/8" 120" 78" 100.0 120.0 100.0 -120-0- - - --36"- (MAX•)- 75:9-75:9--100:0-120:0- 26-1/2--(MAX.)-- -- -88.0--88.0---100.0--120.0- 42" 66.4 66.4 1OD.0 120.0 19-1/8" 120" 100.0 120.0 100.0 120.0 24" 100.0 120.0 100.0 120.0 26-1/2" (MAX.) 84„ 79.8 79.8 100.0 120.0 So" 120" 66" 81.7 81.7 100.0 120.0 .090" Interlayer SentryGlas By 'Kuraray America, Inc.' .075" Interlayer 3/16" HS Saflex CP With PET Core By 'Eastman Chemical Co.' .100" Interlayer Saflex HP Clear or Color. Glass By 'Eastman Chemical Co.', 3/16" HS Alm- Silicone GE-1200 GE-2000 DOW-791 DOW-983 NOTE: DOW-995 GLASS CAPACITIES ON THIS SHEET ARE „ „ 23 At 1/4 Points On Lites BASED ON ASTM E1300-09 (3 SEC. GUSTS) -Glass Type 3 Wider Than 36" AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 1/8" HS .090" Interoyer SentryGlas By 'Kuraray America, Inc.' UNEQUAL LITES WINDOWS (ORIEL) 3/8" Air Space 075" Interlayer 3/f PET Core DESIGN LOAD CAPACITY - PSF 1/8" W.S. GLAOR Byfl Ea tm n�tChemical Co.'. 1/8" AI WINDOW DIMS. TOP VENT GLASS TYPE '3' GLASS TYPE '3A' GLASS TYPE '4' GLASS TYPE '4A' 1/8" TEMP. GLASS .100" Interlayer 1/8" TO WIDTH HEIGHT HEIGHT EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) EXT.(+) INT.(-) EXT.(+) 1 NT.(-) Saflex HP Clear or Color Glass 24" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 154.0 By 'Eastman Chemical Co.' XL EDGE SPACER 1/8" HS XL El 30" 100.0 120.0 100.0 120.0 100.0 1.20.0 100.0 114.0 ST. STEEL BY 'CARDINAL' S Silicone 96 ST• STEEL Bl 32" " �}8" DURASEAL BY QUANEX 100.0 120.0 100.0 120.0 100.0 120.0 100.0 114.0 OR GE-1200 GE-2000 DURASEAL E 36" 100.0 120.0 100.0 120.0 100.0 120.0 99.9 99.9 OR 42" ( ) 100.0 120.0 100.0 120.0 100.0 120.0 88.8 8B.8 SUPER SPACER BY 'QUANEX' DOW-791 SUPER SPACER I DOW-983 48" 100.0 120.0 100.0 120.0 100.0 120.0 62.3 82.3 23 DOW-995 54" 100.0 120.0 100.0 112.6 100.0 120.0 73.7 73.7 Glass Type n4„ At 1/4 Points All Sizes 24" 100.0 2.10.0 100.0 210.0 100.0 210.0 100.0 138.0 30" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 101.0 UNEQUAL LITES WINDOWS (ORIEL) 32" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 101.0 DESIGN LOAD CAPACITY - PSF 36" (MAX.) 100.0 100.0 120.0 100.0 120.0 100.0 120.0 87.4 87.4 WINDOW DIMS. TOP VENT GLASS TYPE '3' GLASS TYPE '3A' GLASS TYPE W GLASS Ti 42" 100.0 120.0 100.0 120.0 100.0 120.0 78.2 78.2 WIDTH HEIGHT HEIGHT EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) EXT.(+) 48" 100.0 120.0 100.0 112.2 100.0 120.0 71.5 71.5 19-1/8" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 24" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 127.0 26-1/2" 96" 48" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 30" 100.0 120.0 100.0 120.0 100.0 120.0 93.4 93.4 37" (MAX.) 100.0 120.0 100.0 120.0 100.0 120.0 97.8 32" 120" 60" 100.0 120.0 100.0 120.0 100.0 120.0 93.4 93.4 1 53-1/8" 100.0 120.0 100.0 114.4 100.0 120.0 75.4 36" (MAX.) 100.0 120,0 100.0 120.0 100.0 120.0 1 79.0 79.0 19-1/B" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 42" 100.0 120.0 100.0 1.14.1 1 100.0 120.0 69.1 69.1 26-1/2" 108" 54" 100.0 120.0 100.D 120.0 100.0 120:0 . 100.0 24" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 120.0 37" (MAX•) 100.0 120.0 100.0 120.0 100.0 120.6 85.4 30" 120" 66" -1 WO-0--120:0--100:0--120:0--100.-0--120.-0--833--817---19=1/8"- -- -100.-0--210.0-100.0-20k2-100:0-210:0-100.0-- 32" (MAX,) 100.0 120.0 100.0 120.0 100.0 120.0 83.7 83,7 26-1/2" 120" 60" 100.0 120.0 100.0 120.0 100.0 120.0 100.0 36" 100.0 120.0 1 100.0 120.0 100.0 120.0 70.0 70.0 37" (MAX-) 100.0 120.0 100.0 120.0 100.0 120.0 77.1 24" 100.0 1 120.0 I 100.0 120.0 .100.0 120.0 100.0 117.0 19-1/8" 100.0 210.0 100.0 210.0 100.0 210.0 100.0 Installation Type »A» IMPORTANT NOTE: nTICA.L 'A w/ 1 x 4 Beveled P.T. Wood Buck Wood Wads Bucks bt sustain 1•/4" DIA. ULT imposedY glazing system and transfer 1.14" DIA. -ULT . them to the building /4" DIA. HIL' Buck bed in structure. °A structure. sealant (typ) INTO 2BY WOC ° °: 1-1/2" MIN. 7,11 H1/4" Dia. 1-1/4" MIN. - Flat Head Sealant 1-1/4" MIN. Ultracon, (typ) E DIRECTLY INTO Ultracon+ or Kwik-con �, 1-3/4"�� MIN. or equal o a 1-3/4 MIN. O E .�', 1/4" DIA, TEK INTO METAL S (3) THREADS ALUMINUM : 1 STEEL : 1/8" Id A. (STEEL IN COP a 14 SMS(GRAD 3 1/2" INTO MIAMI-D� c Min. (3) THREADS ALUMINUM: 1/ STEEL: 1/8" 1 (STEEL IN COP 4 _ Q TYPICAL EDGE ° . a 2 3/4" INTO CONCRET INTO WOOD S1 INTO METAL S' �! 1 x 4 Beveled P.T. Wood Buck (typ.) WOOD AT HEAD, � CONCRETE AT F. J B & JT C-90 FILLED BI Min. Values for Installation Type "A" app maximum shim space 1/4": 1— Using 1 by P.T. wood bucks, mi _ optional 2— Directly into masonry, without t Sealant Non-beveled rm OWood Buck S (dotted) 3— Directly into a steel or aluminu Str unture. mh st hp ci qi using #h4 IV Installation Type "B" Installation Type "C w/ 2 x 4 Beveled P.T. Wood Buck based on wood penetration only using 1 x 4 or 2 x 4 wood bucks Buck bed in �° . °a ° Buck bed it sealant (typ) ° sealant (typ 1/4" Dia. Flat Head I Sealan- Itracon/Ultracon+/Kwik—Con - 1/4" Dia. Flat Head (typ) (or Equal) Sealant Teks Or 1-1/2" Min. Wood Embed .(typ) J;9E X4" Dia. Ultracon/Ultracon+ N wik—Con Fasteners O E a v 1 x 4 & 2 x 4 F ---, 3 1/2" I Min. l 'd c � a � ' N M a � a o\ . 2 3/4" 2 x 4 Beveled P.T. Wood Buck (typ.) JB & JT JB & JT ------- - - 1 1/2" Min. —__ Total Wood Sealant Non—beveled Penetration Wood Buck (dotted) ANCHORS ANCHORS DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY - PSF NO. OF STD, HOLE PATTW STD. HOLE PANM O OF STD. HOLE PATTERN STD. HOLE PATTERN WINDOW DIMS. ANCHORS W/o ADDL ANCHOR lIIIR ADDL ANCHOR WINDOW DIMS. ANCHORS W/O ADDL. ANCHOR VIK ADDL. ANCHOR WIDTH HEIGHT AT JAMB EXT.(+) & INT.(-) EXr.(+) & INT.(-) WIDTH HEIGHT AT JAMB EXT.(+) & INT.(-) EXT.(+) & INT.(-) 24" 210.0 210.0 19-1/8" 210.0 210.0 30" 210.0 210.0 26-1/2" 26" 4 210.0 210.0 32" 210.0 210.0 37" 210.0 210.0 36" 48" 4 196.0 210.0 53-1/8" 208.6 210.0 42" 174.2 210.0 19-1/8" 210.0 210.0 .48"- 151'.7 196.0 26-1/2" 38-3/8" 4 210.0 210.0 54" 1 127.1 178.2 37" 210.0 210.0 24" 210.0 210.0 53-1/8" 152.7 210.0 30" 210.0 210.0 19-1/8" 210.0 210.0 32" 60" 6 210.0 210.0 26-1/1" 50-5/8" 4 210.0 2i0.0 36" 210.0 210.0 37" 179.6 210.0 42" 171.1 210.0 53-1/8" 125.7 169.5 48" 134.4 201.6 19-1/8" 210.0 210.0 54" 110.7 166.0 26-1/2" 63" 6 210.0 210.0 24" 210.0 210.0 37" 203.8 210.0 30" 210.0 210.0 53-1/8" 110.7 166.1 32" 210.0 210.0 19-1/8" 210.0 210.0 36" 72" 8 210.0 210.0 26-1/2" 72" 8 210.0 210.0 42" 165.1 210.0 37" 210.0 210.0 48" 125.4 188.2 53-1/8" 104.1 156.1 54" 101.2 151.7 19-1/8" 210.0 210.0 24" 210.0 210.0 26-1/2" 76" 8 210.0 210.0 30" 210.0 210.0 37" 210.0 210.0 LOADS APPLY TO 32 207.5 210.0 53-1/8" 102.1 153.1 A, B & C AND II 36" 84" 8 190.1 210.0 FOR ALUMINUM B 42" 164.9 192.0 48" 122.2 175.3 SHEETS 13 AND 54" 1 96.0 144.0 24" 210.0 210.0 Width 30" 185.8 209.1 32" 176.4 198.5 6"I---21 6" 36" 96" 8 180.8 180.9 max. Installation 42." 143.4 161.3 /Screws 48" 122.1 147.0 in ---- --------- Addl.-Anchor------ 54" 94.1 135.7 ,� a At Mtg. Stile Ends ----24 - 210:0 210-.0 - _E- Regd-For-Higher-Loads 30 „ 202.3 210.0 c (if Applicable) 0, 32" 108" 10 191.7 210.0 = See Chart For Capacity 3R" 174.2 191.6 PERFORMANCE VALUES PEAFORMA OF ALUMINUM BUCK OF ALUM INSTALLATION ANCHORS INSTALLATI M.(+) & INT.(-) EXT.(+) BHA Ow DIMS. ANCHORS MTO HOLLOW BLOCK ANCHORS INTO CONC. ANCHORS im IIOOD WMDOW DUO. ANCHORS ]NTO HOLLOW.BLOCK CLUSTER CLUSTER CLUSTER CLUSTER=SIBR CLUSTER CLUSTER CLUSM CLUSTER CLUSTER CLUSTER CLUSTER CLUSTER CLUSTER CLUSTER CLUSTER CLU57 WIDTH HEIGHT OF 2 OF 4 OF 6 OF 8 OF 2 OF 4 OF 6 OF 8 OF 2 OF 4 OF 6 OF 8 WIDTH HEIGHT OF 2 OF 4 OF 6 OF B OF ; 24" 89.3 178.7 210.0 210.0 140.0 210.0 210.0 210.0 120.0 210.0 210.0 210.0 19-1/8" 210.0 210.0 210.0 210.0 210. 30" 78.0 155.9 210.0 210.0 122.2 210.0 210.0 210.0 104.7 209.5 210.0 210.0 26-1/2" 26" 210.0 210.0 210.0 210.0 210. 32" 75.4 150.8 210.0 210.0 118.1 210.0 210.0 210.0 101.3• 202.5 210.0 210.0 37" 210.0 210.0 210.0 210.0 210, 36" 48" 71.5 142.9 210.0 210.0 112.0 210.0 210.0 210.0 96.0 192.0 210.0 210.0 53-1/8" 210.'0 210.0 210.0 210.0 210, 42" 68.1 136.1 204.2 210.0 106.7 210.0 210.0 210.0 91.4 182.9 210.0 210.0 19-1/8" 140.1 210.0 210.0 210.0 210. 48" 67.0 134.0 201.0 210.0 105.0 210.0 210.0 210.0 90.0 180.0 2'10.0 210.0 26-1/2" 38-3/8115.9 210.0 210.0 210.0 181._ ----54- 67.0 134.0 201.0 210.0 105.0 210.0 210.0 210.0 90.0 180.0 210.0 210.0 37" 105.0 209.9 210.0 210.0 164, 24" 67.0 134.0 201.0 210.0 105.0 210.0 210.0 210.0 90.0 180.0 210.0 210.0 53-1/8" 104.8 209.6 210.0 210.0 164; 30" 57.2 114.3 171.5 210.0 89.6 179.2 210.0 21.0.'0 76.8 153.6 210.0 210.0 19-1/e 98.3 196.6 210.0 210.0 154. 32" 54.8 109.6 164.5 210.0 85.9 171.8 210.0 210.0 73.6 147.3 210.0 210.0 26-1/2" 50-5/8" 77.9 155.9 210.0 210.0 122 36" 60" 51.0 102.1 153.1 204.2 80.0 160.0 210.0 210.0 68.6 137J 205.7 210.0 37" 64.9 129.9 194.8 210.0 101, 42" 47.1 94.2 141.4 188.5 73.8 147.7 210.0 210.0 63.3 126.6 189.9 210.0 53-1/8" 60.2 120.5 180.7 210.0 94: 48" 44.7 89.3 134.0 178.7 70.0 140.0 210.0 210.0 60.0 120.0 180.0. 210.0 19-1/8" 75.5 151.0 210.0 210.0 118. 54" 43.3 86.6 129.9 173.3 67.9 135.8 203.6 210.0 58.2 116.4 174.5 210.0 26-1/2" fi3" 58.5 117.1 175.6 210.0 91: 24" 53.6 107.2 160.8 210.0 84.0 168.0 210.0 210.0 72.0 144.0 210.0 210.0 37" 46.9 03.8 140.6 187.5 73. 30" 45.1 90.3 135.4 180.5 70.7 141.5 210.0 210.0 60.6 121.3 181.9 210.0 53-1/8" 39.9. 79.7 119.6 159.5 62. 32" 43.1 86.1 129.2 172.3 67.5 135.0 202.5 210.0 57.9 115.7 173.8 210.0 1.9-1/8" 64.6 129.3 193.9 210.0 101. 36" 72" 39.7 79.4 119.1 158.8 62.2 124.4 186.7 210.0 53.3 106.7 160.0 210.0 26-1/2" 72" 49.6 99.2 148.7 198.3 77: 42" 36.0 72.1 108.1 144.1 56.5 112.9 169.4 210.0 48.4 96.8 145.2 193.6 37" 39.0 1 78.0 117.0 156.0 61. 48" 33.5 67.0 100.5 134.0 52.5 105.0 157.5 210.0 45.0 90.0. 135.0 180.0 53-1/0" 32.0 1 64.0 95.9 127.9 50. 54" 31.8 63.5 95.3 127.1 49.8 99.6 149.3 199.1 42.7 85.3 128.0 170.7 19-1/8" 60.7 121.5 182.2 210.0 95.: 24" 44.7 89.3 134.0 178.7 70.0 140.0 210.0 210.0 60.0 120.0 180.0 210.0 26-1/.2" 76" 46.4 92.8 139.2. 185.7 72: 30" 37.3 74.6 111.9 149.1 58.4 116.9 175.3 216.0 50.1 100.2 150.3 200.3 37" 36.3 72.6 108.8 145.1 56.' 32" 35.5 70.9 106.4 141.9 55.6 111.2 168.8 210.0 47.6 95.3 142.9 190.6 53-1/8" 29.4 58,8T 88.2 117.6 46. 38" 84" 32.5 '65.0 97.5 129.9 50.9 101.8 152.7 203.6 43.6 87.3 130.9 174.5 42" 29.2 58.3 87.5 1163 45.7 91.4 137.1 182.9 39.2 78.4 117.6 156.7 48" 26.8 53.6 80.4 107.2 42.0 84.0 126.0 168.0 36.0 72.0 108.0 144.0 12" PRE PUNCHEC 3" TYP. ALL OTHER H, 54" 25.1 50.2 75.2 100.3 393 78.6 117.9 157.2 33.7 67.4 101.1 134.7 SPACING DRILLED IN FI 24" 38.3 76.6' 114.9 153.1 60.0 120.0 180.0 210.0 51.4 102.9 154.3 205.7 ��� �\ 3 99. 28.0 170.7 30 31.8 63.5 95.3 127.1 49.8 99.6 149. 1 1 42.7 85.3 1 32" 30.1 60.3 90.4 120.E 47.2 94.5 141.7 1 B9.0 40.5 81.0 121.5 162.0 36" 96" 27.5 55.0 82.5 109.0 43.1 86.2 129.2 172.3 36.9 73.8 110.8 147.7 42" 24.5 49.0 73.5 98.0 38.4 76.8 115.2 153.6 32.9 65.8 98.7 131.7 48" 22.3 44.7 67.0 89.3 35.0 70.0 105.0 140.0 30.0 60.0 90.0 120.0 54" 20.7 41.4 62.1 82.9 32.5 64.9 97.4 129.9 27.8 55.7 83.5 111.3 1X4MULLIONEE SHT 8 OF 11 24" 33.5 67.0 100.5 134.0 52.5 105.0 157.5 210.0 45.0 90.0 135.E 180.0 30" _ 27.7 55.3 83.0 110.7_ 43.4_ -86.7 ___130.1--173.4-- --37.2-- --74.3----1-1-1.5- -148.6- - - - - ---- - _ - - 32" - 26.2 52.4 78.7 104.9 41.1 82.2 123.3 164.3 35.2 70.4 105.7 140.9 H 36" 23.8 47.6 71.5 95.3 37.3 74:7 112.0 149.3 32.0 64.0 96.0 128.0 42" 21.1 42.2 63.4 84.5 33.1 66.2 99.3 132.4 28.4 56.7 85.1 113.5 48" 19.1 30.3 57.4 76.6 1 30.0 60.0 90.0 120.0 25.7 51.4 77.1 102.9 n. nne ene on ..n unn nnn 4cnn