Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 , BCIS Home Log In j User Registration Hot Topics Submit Surcharge i Stats&Facts ; Publications Contact Us 1 BCIS Site Map I Links Search Ronda a Product Approval r USER:Public User / ti t s REVIEWED FOR Product Approval Menu>Product or Aouliwtion Search>Application List>Application Detail A 4 FL# FL33818 CODE C®M■®LiANCE Application Type New T. LUCIE COUNTY Code Version 2020 Application Status Approved CC Comments File, C o T,r'�<. Archived _. a� Product Manufacturer Gulf Coast Supply&Manufacturing,LLC. Address/Phone/Email 4020 S.W.449th Street Horseshoe Beach,FL 32648 (352)498-0778 Ext 0565 jared.pearce@gulfcoastsupply.com Authorized Signature Jared Pearce jared.pearce@gulfcoastsupply.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/31/2023 Validated By Steven M. Urich,PE mJ' Validation Checklist-Hardcopy Received Certificate of Independence FL33818 RO COI GCS20002a 2020 FBC Eva]Metal Roofing NonHVHZ final, df Referenced Standard and Year(of Standard) Standard Year ASTM B 117 2016 ASTM G 155 2013 FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtcpgflynXQVd... 4/l/2021 Florida Building Code Online Page 2 of 2 ' Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/11/2020 Date Validated 10/31/2020 Date Pending FBC Approval 11/05/2020 Date Approved 12/16/2020 Summary of Products FL# Model,Number or Name Description 33818.1 Metal Roofing Systems(HVHZ) GulfLok,VersaLoc,5V Crimp,GUIfPBR and GulfRib Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL33818 RO II GCS20002b 2020 FBC Eval Metal Roofing Approved for use outside HVHZ:No HVHZ final.Ddf Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021 Design Pressure:+0/-164.25 Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL33818 RO AE GCS20002b 2020 FBC Eval Metal Roofing HVHZ final,,pdf Created by Independent Third Party: Yes 33818.2 Metal Roofing Systems(nonHVHZ) GulfLok,GulfSeam,MegaLoc,VersaLoc,5V Crimp,GUIfPBR, GulfRib and GulfWave Limits of Use Installation Instructions Approved for use in HVHZ:No FL33818 RO II GCS20002a 2020 FBC Eval Metal Roofing Approved for use outside HVHZ:Yes NonHVHZ final.Ddf Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021 Design Pressure:+0/-164.25 Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL33818 RO_.AE GCS20002a 2020 FBC Eval._h1etat._goonna NonHVHZ final.odf Created by Independent Third Party:Yes Bactc Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. F1Product Apprr�ooval Accepts: sl ER M Credit Cafe! Safe a https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtcpgflynXQVd... 4/1/2021 .. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,7"EDITION(2020) Manufacturer: GULF COAST SUPPLY&MANUFACTURING, LLC Issued October 22, 2020 14429 SIN 2n0 Place, Suite G30 Newberry, FL 32669 (352)498-7852 www.qulfcoastsur)plv.com Manufacturing Locations: Alachua, FL Sebring, FL Montgomery,AL Quality Assurance: Keystone Certifications, Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Enti Report No. Standard Year Force Engineering&Testing(TST5328) 72-0313T-06A-C UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 72-0198T-07A-C UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0033T-05 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0053T-05 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0062T-07A-C UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0062T-07D-F UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0062T-07G-1 UL 580 2006 UL1897 2012 Force Engineering&Testing(TST5328) 117-0062T-07J-K UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0065T-07A-C " UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0076T-12A UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0089T-05.1 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0089T-05.2 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0102T-05 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0165T-11 B UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0238T-09D FM 4471 1992 Force Engineering&Testing(TST5328) 117-0238T-09E FM 4471 1992 Force Engineering&Testing(TST5328) 117-0238T-11A FM 4471 1992 Force Engineering&Testing(TST5328) 117-0248T-07A,B UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0284T-09A UL 580 2006 UL 1897 2012 GCS20002a FL33818 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKGULF COAST SUPPLY&MANUFACTURING,LLC Metal Roofing TECHNICAL SERVICES. LLC Entity Report No. Standard Year Force Engineering&Testing(TST5328) 117-0285T-09A UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0301T-10A-C UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0330T-10A-B UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0331T-08A UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0331T-08B UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0331T-08D UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0337T-10 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0378T-11A FM 4471 1992 Force Engineering&Testing(TST5328) 117-0378T-11 B FM 4471 1992 Force Engineering&Testing(TST5328) 117-0378T-11C FM 4471 1992 Force Engineering&Testing(TST5328) 117-0407T-09 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 117-0407T-09A UL 580 2006 UL 1897 2012 Intertek-West Palm Beach(an ATI company) (TST1527) B9000.01-450-18 UL 580 2006 UL 1897 2012 Intertek-West Palm Beach(an ATI company) (TST1527) C0308.01-450-18 UL 580 2006 UL 1897 2012 Intertek-West Palm Beach(an ATI company) (TST1527) D0818.01-450-18 UL 580 2006 Intertek-West Palm Beach(an ATI company) (TST1527) D1692.01-450-44 UL 580 2006 UL 1897 2012 ASTM E 8 Intertek-West Palm Beach(an ATI company) (TST1527) G7287.01-450-44 UL 580 2006 PRI Construction Materials Technologies(TST5878) 1272T0005 ASTM G 155 2013 GCS20002a FL33818 Page 2 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ry'' CREEKGULF COAST SUPPLY&MANUFACTURING,LLC Metal Roofing TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION GulfLok Profile: :. 1 in.snap.lock seam; Max.16 in.coverage Description: j Non-structural,snap lock standing seam roof panel with 7/8 in.slotted nail strip Material: Min.26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon@ paint finish; Fy_=min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032 in.ASTM B209, 3105 H24 aluminum; Optional Fluropon®paint finish; i —— Fy=min.24 ksi; Shall conform with FBC Section 1507.4_3 { 12"and 16"Coverage GulfSeam ; Profile: 1 3/4 in.snap lock seam; Max. 18 in. coverage Description: i Non-structural,snap lock standing seam roof panel Material: Min.24 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint finish; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 ---...................................... -...._._—_... -................__._._ ---......._._.......................__........__..-.._.__--... I Min. 0.032-inch ASTM B209,3105 H24 aluminum, Optional Fluropon®paint finish; - - Fy=min. 21 ksi; Shall conform with FBC Section 1507.4.3 _ --.....-- ....................... ..................------.—..............._._..— i i i i i i I i 1$f$N 14",16",and 181,Coverage MegaLoc Profile: 2 in.mechanical seam; Max. 18 in.coverage ---•__-- _ _.._....._._.._. ..... _.. I Description: ! Non-structural, mechanical lock 1800 standing seam roof panel Material: Min.24 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint finish; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 i i i I 2" i i GCS20002a FL33818 Page 3 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKGULF COAST SUPPLY&MANUFACTURING,LLC Metal Roofing TECHNICAL SERVICES, LLC Versal-oc i Profile: i 1.5 in. mechanical seam; Max. 18 in. coverage _ Description: Non-structural,mechanical lock 1800 standing seam roof panel Material: Min.24 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint [ finish; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 i I I I I tgR-18"Covera90 I 5V Crimp Profile: 7/16 in. ribs at 12 in. o.c.;24 in.coverage Description: j Non-structural,through fastened roof panel Material: I Min.26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon@ paint finish; F =min. 50 ksi; Shall conform with FBC Section 1507.4.3 .---_..-.-......I.......... _.....- --.......... - _..--- - Min.0.032 in.ASTM B209, 3105 H24 aluminum; Optional Fluropon@ paint finish; j Fy=min. 25 ksi; Shall conform with FBC Section 1507.4.3 j I . j 7/1b"$ 12" I 24"Coverage GuIfPBR Profile: ; 1 1/4 in. ribs at 12 in.o.c.; 36 in. coverage ---_: —__...........�.—_._.._._........— _...- - -................-------.-._.._.._� Description: j Non-structural,through fastened roof panel Material: Min.26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon@ paint j finish; Fy=min. 80 ksi; Shall conform with FBC Section 1507.4.3 j i j 124' j 36"Coverage GCS20002a FL33818 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREC GULF COAST SUPPLY&MANUFACTURING,LLC EK Metal Roofing TECHNICAL SERVICES, LLC GulfRib ; Profile: 3/4 in. ribs at 9 in. o.c.;36 in.coverage _ — Description: 3 Non-structural,through fastened roof panel Material: Min.29 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint j finish_FY=min. 80 ksi; Shall conform with FBC Section 1507.4.3 i i I i i i 3/4"1 -..-----91. 36"Coverage GulfWave I Profile: 3/4 in. corrugation;29 in.coverage _._._........................... _— _�._..._-....._.. — ----......-......_.......... _._.....__........ ------- Description: Non-structural,through fastened roof panel Material: Min.26 ga.ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon®paint finish; Fy=min.80 ksi; Shall conform with FBC Section.1507.4.3 i i I 3l411 ,, . 2 g Coverage GCS20002a FL33818 Page 5 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKGULF COAST SUPPLY&MANUFACTURING,LLC Metal Roofing TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. Recovery versus replacement shall be evaluated in accordance with FBC Section 1511.3. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7t'Edition(2020)as evidenced in the referenced documents submitted by the named manufacturer. ,%0%J1a11111, ,`,•`,P�'�P C,EN %s 2020.10.22 _ _ << No 74021 � � = 15:51 :16 Olmt•Py M9M9Oy SeauY P.PMat % 0 STATE OF Z/� 0 ■ '00' 0% �v ����`•'•., O R l G �� Zachary R. Priest, P.E. Florida No. s'ON A,��. '% Organization No.Ion ANE9641021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation(5 pages) 2) APPENDIX B—Approved Roof Systems(7 pages) 3) APPENDIX C—Design Wind Loads (4 pages) GCS20002a FL33818 Page 6 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY&MANUFACTURING,LLC CREEK Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A INSTALLATION Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail #9-15 HWH wood screw with sealing washer #9-15 HWH WoodZAC screw #10-12 Pancake Type A Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion screw resistant in accordance with FBC section 1507.4.4. Fasteners #12-11 Pancake Type A screw #12-8 HWH Woodgrip XG screw with sealing washer 1/4-14 HWH ZAC Impax Installed at panel side lap;Shall be corrosion resistant in accordance with FBC Lap screw section 1507.4.4. 24 ga.in-seam clip 1,iC GulfLok Clip Clips 18 ga.in-seam clip I � S Fixed Clip GCS20002a FL33818 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKGULF COAST SUPPLY&MANUFACTURING,LLC Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail —— E 4-1/4' I NC-33003-3 Sliding Clip 1/2" { } — �-Jjt Clips(Cont'd) 22 ga.top; 16 ga.base;in-seam clip - i l 1500SC Sliding Clip f J I (iii'3± 'iti.8 `z ...........-............ � TiteBond Weathermaster ' Sealants Metal Roof Sealant Shall be applied in 1/4"-5/16"continuous beads on the male rib along the seam Fastening Details Nomenclature Attachment i' Guftok Type 1 (1) #10-12 X 1"TYPE A PANCAKE M84'#43 STAINLESS GULF LOK PANEL STEEL WET @ 6- (OVERLAP SIDE O-C_ GulfLok Overlap -` GULF L10K PANEL (UNIDE LAP SIDE) P N CLIP SCREW GCS20002a FL33818 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY&MANUFACTURING,LLC CREEKMetal Roofing TECHNICAL SERVICES, LLC APPENDIX A Fastening Details Nomenclature Attachment GulfLok'" CLIP 24 GA. GulfLok Type 2 (1) #10-12 X 1"TYPE A PANCAKE-- 18 Ga. Fixed Clip Gu/fSeam Type 1 7 (2) #10-12 x 2"Pancake Type A Per Clip. tV MegaLoc Type 1 T—"C-33003 SLIDING CLIP (2) #10-12 x 1"per Clip IN T VersaLoc Type 1 -'i< T—,500SC SLIDING CLIP (2)#12-1 i x 1"Panhead per Clip::3— (1) #9-15 x 1-1/2u HWH w/Sealing Washer 5V Type 1 12" 12"� At Panel Lap (1 ) #9-15 x 1-1/2" HWH w/Sealing Washer 5V Type 2 I 211 — 9.511 00110V.511 211 J GCS20002a FL33818 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY&MANUFACTURING,LLC CREEKMetal Roofing TECHNICAL SERVICES, LLC APPENDIX A Fastening Details Nomenclature Attachment �---12" �-- 1211 � 5V Type 3 At Panel Lap 7 L(1) #9-15 x 1-1/2" HWH w/Sealing Washer At Panel Lap -� #1/4-14 x 70 Lap Screw @ 24"O.C. Max.--� 12" 12" Gu/fPBR Type 1 l ��—(1)#9-15 x 1-112" #1/4-14 x 7/8"Lap Screw @ 24"O.C.Max. 101-511711 511 711 1511 GuIfPBR Type 2 711 �51111� � � , —(1)#9-15 x 1-112" 911 ,710 At Panel Lap Gu/fRib Type 1 Z(1) #9.15 x 1-1/2"w/Sealer Washer 6.5"-71 2.5"1 F 6.5" 2.5"T-6.5" 2.5" GulfRib Type 2 zo) #9-15 x 1-1/2"w/Sealer Washer GCS20002a FL33818 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. a GULF COAST SUPPLY&MANUFACTURING,LLC W - CREEK Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system. 5. The panel thickness or gauge is the minimum allowable. 6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(Fy=min.40 ksi)Wide Rib Deck(Type WR) conforming to ANSI/SDI-RD1.0&FBC. 7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood , sheathing at maximum 24-inch span. Roof System Numbers and Definitions LOK-W# GulfLok over Wood Deck New or Existing) SEAM-W# GulfSeam over Wood Deck(New or Existing) MEGA-W# Me aLoc over Wood Deck New or Existing) VL-W# 1.5"VersaLoc over Wood Deck new or Existing) 5V-W# 5V Crimp over Wood Deck New or Existing) PBR-W# GuIfPBR over Wood Deck New or Existing) RIB-W# I GulfRib over Wood Deck New or Existing) WAVE-W# GulfWave over Wood Deck New or Existing) Approved Systems for GulfLok over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 15/32 OPTIONAL 26 ga.,Grade 80 GUIfLok Gu/fLok Type 1 attachment #10-12 x 1" LOK-W-1 B-C plywood Approved fire barrier As required per FBC Max. 16-inch coverage Pancake Type A p screws spaced 5-3/16 in.o.c 63.5 or insulation Min. 15/32 OPTIONAL Min.0.032"Al GulfLok Gu/fLok Type 1 attachment with #10-12 x 1" LOK-W-2 B-C plywood Approved fire barrier As required per FBC Max.16-inch coverage Pancake Type A screws spaced 5-3/16 in.o.c. or insulation Min. 15/32 OPTIONAL 24 ga.GulfLok Gu/fLok Type 1 attachment with#10-12 x 1" _81.75 LOK-W-3 B-C plywood Approved fire barrier As required per FBC Max.16-inch coverage Pancake Type A screws spaced 10-1/4 in.o.c. or insulation OPTIONAL LOK-W-4 Min. 1 woo Approved fire barrier As required per FBC 24 ga.GulfLok GulfLok Type 1 attachment with 5-1/8 i x .c _g6.75 B-C plywood or insulation Max.16-inch coverage Pancake Type A screws spaced 5-1/8 in.o.c. GCS20002a FL33818 Page 1 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other_ product attributes that are not specifically addressed herein. r� CREEKGULF COAST SUPPLY&MANUFACTURING,LLC Metal Roofing TECHNICAL SERVICES. LLC APPENDIX A Fastening Details Nomenclature Attachment GulfRib Type 3 #9-15 x 2"wlSealer Washer At Panel Lap-79" ��� 9,��6.5" GulfRib Type 4 �-(1)#12-8 x 1-1/2"WoodGrip XG W/Sealer Washer At Panel Lap �811�811�811�5.3311� GulfWave Type 1 (1) #9-15 x 1-1/2" HWH w/Sealing Washer GCS20002a FL33818 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY&MANUFACTURING,LLC CREEK. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for Gulfl-ok over Wood.Deck(New or Existing) System Deck Fire Barrier Underlayment' Roof Panel Panel Attachment MDP No. (psfl OPTIONAL Guftok Type 1 attachment with #10-12 x 1'` LOK-W-5 Min.15/32 Approved fire barrier As required per FBC Min.0.032"AI GulfLok Pancake Type A screws spaced 5-3/16 in.o.c. -116 B-C plywood or insulation Max. 16-inch coverage Titebond Weathermaster Metal Roof Sealant applied to male rib. OPTIONAL Gu/fLok Type 1 attachment with#10-12 x 1" Min.15/32 Min.26 ga.Gulfl-ok Pancake Type A screws spaced 5-3/16 in.o.c. -121.75 LOK-W 6 CDX plywood Approved fire barrier As required per FBC Max.16-inch coverage Titebond Weathermaster Metal Roof Sealant or insulation applied to male rib. Min. 15/32 OPTIONAL 26 ga.,Grade 80 Gulf-ok Gu/fLok Type 2 attachment with LOK-W-7 B-C plywood i Approved fire barrier As required per FBC Max.16-inch coverage #10-12 x 1"Pancake Type A screws through -161 or insulation clip and spaced 5-3/16 in.o.c. Approved Systems for GulfSeam over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psfl Min.15/32 OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment SEAM-W-1 B-C plywood Approved fire barrier As required per FBC Max. 18-inch coverage with clips spaced 24 in.O.C. -69.25 or insulation 5/32 OPTIONAL SEAM-W-3 CDX plywood Min. ywood Approved fire barrier As required per FBC Min.0.03 GulfSeam GulfSeam Type 1 attachment -86 or insulation Max. 18-inn chh coverage with stainless steel clips spaced 18 in.o.c. Min. 1x4 No.2 SYP wood purlins spaced OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spaced SEAM-W-4 18 in.o.c. Approved fire barrier As required per FBC Max.16-inch coverage 18 in.o.c.over wood purlins -93.5 over or insulation Min.15/32 B-C plywood Min. 15/32 OPTIONAL Min.24 ga.GulfSeam GulfSeam Type 1 attachment SEAM-W-5 B-C plywood Approved fire barrier As required per FBC Max. 18-inch coverage with clips spaced 12 in.o.c. -108.5 or insulation GCS20002a FL33818 Page 2 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK GULF COAST SUPPLY&MANUFACTURING,LLC Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for GulfSeam over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min.1x4 No.2 SYP wood purlins spaced OPTIONAL SEAM-W-6 24 in. Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spaced overr or insulation Approved fire barrier As required per FBC Max.18-inch coverage 24 in.o.c,over wood purlins -114.25 Min. 15/32 CDX plywood Min.15132 OPTIONAL SEAM- Min.0.032"All GulfSeam GulfSeam Type 1 attachment W-7 CDX plywood Approved fire barrier As required per FBC -138.5 p y or insulation Max, 16-inch coverage with stainless steel clips spaced 6 in.o.c. Min.1x4 No.2 SYP wood purlins spaced OPTIONAL SEAM-W-B 12 in. Min.24 ga.GulfSeam GulfSeam Type 1 attachment with clips spaced Approved fire barrier As required per FBC Max. 18-inch coverage 12 in.o.c.over wood purlins -159.25 overr or insulation Min.15/32 CDX plywood Approved Systems for MegaLoc over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) MEGA-W-1 Min. 15/32 OPTIONAL Min.24 ga.MegaLoc MegaLocType 1 attachment B-C plywood Approved fire barrier As required per FBC Max. 18-inch coverage vvith clips spaced 24 in.o.c. -71 or insulation Min. 15/32 OPTIONAL Min.24 ga.MegaLoc MegaLocType 1 attachment MEGA-W-2 B Cywood plywood Approved fire barrier As required per FBC Max. 18-inch coverage with clips spaced 12 in.o.c. -108.5 or insulation GCS20002a FL33818 Page 3 of 7 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY&MANUFACTURING,LLC .� CREEK Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for VersaLoc over Wood Deck(New or Existing) System 'Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min.15/32 OPTIONAL Min.24 ga.VersaLoc VersaLoc Type 1 attachment -59.75 VL-W-1 B-C plywood Approved fire barrier As required per FBC Max.16-inch coverage with clips spaced 24 in.o.c. or insulation Min. 15l32 OPTIONAL Min.24 ga.VersaLoc VersaLoc Type 1 attachment -123.5 VL-W-2 Approved fire barrier As required per FBC B-C plywood or insulation Max.16 inch coverage with clips spaced 6 in.o.c. Approved Systems for 5V Crimp over Wood Deck(New or Existing) System Fire Barrier/ o MDP 'Deck Underlayment Roof Panel Panel Attachment No. Insulation (psf) Min. 15/32 OPTIONAL Min.26 ga.5V Crimp 5V Crimp Type 3 attachment with#9-15 HWH wood 5V-W1 B-C plywood Approved _94.25 fire barrier As required per FBC 24-inch coverage screws with sealing washers spaced 16 in.o.c. or insulation Min. 15/32 OPTIONAL Min.0.032"AI or 5V Crimp Type 1 attachment with#9-15 HWH wood 5V-W2 B-C plywood Approved fire barrier As required per FBC Min.26 ga.5V Crimp screws with sealing washers spaced 12 in.o.c. -108.5 or insulation 24-inch coverage Min. 15/32 OPTIONAL Min.26 ga.5V Crimp 5V Crimp Type 2 attachment with#9-15 HWH wood _131 5V-W3 B-C plywood Approved fire barrier As required per FBC 24-inch coverage screws with sealing washers spaced 16 in.o.c. or insulation Min. 15/32 OPTIONAL Min.26 ga.5V Crimp 5V Crimp Type 1 attachment with 5V-W4 B-C plywood Approved fire barrier As required per FBC 24-inch coverage #9-15 HWH wood screws with sealing washers spaced 6 -158.5 or insulation in.o.c. GCS20002a FL33818 Page 4 of 7 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEKGULF COAST SUPPLY&MANUFACTURING,LLC Metal Roofing TECHNICAL.SERVICES, LLC APPENDIX B Approved Systems for GuIfPBR over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (W OPTIONAL GulfPBR Type 1 attachment with#9-15 15 HWH WoodZAC PBR-W-1 Min.15/32 Min.26 ga.GuIfPBR screws spaced 24 in.o.c. B-C plywood Approved fire barrier As required per FBC 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Impax La -60.5 or insulation P P screws spaced 24 in.o.c. Min. 1x4 No.2 SYP wood purlins spaced OPTIONAL GulfPBR Type 1 attachment with#9-15 HWH WoodZAC PBR-W-2 24 in.o.c. Approved fire barrier As required per FBC Min.26 ga.GuIfPBR screws spaced 24 in.o.c.into wood purlins 100.5 over or insulation 36-inch coverage Laps fastened with 1/4-14 x 7/8 ZAC Impax Lap screws Min.15132 spaced 24 in.o.c. B-C plywood Min. 1x4 No.2 SYP wood purlins spaced OPTIONAL GulfPBR Type 2 attachment with#9-15 15 HWH PBR-W-3 12 in.o.c. Approved fire barrier As required per FBC Min.26 ga.GuIfPBR WoodZAC screws spaced 12 in.o.c.into wood purlins 151.75 over or insulation 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Impax Lap Min.15/32 screws spaced 24 in.o.c. B-C plywood OPTIONAL GulfPBR Type 2 attachment with#9-15 HWH WoodZAC PBR-W-4 Min.15/32 Approved fire barrier As required per FBC Min.26 ga.GulfPBR screws spaced 12 in.o.c. B-C plywood Impax or insulation P P 36-inch coverage Laps fastened with 1/4-14 x 7/8"HWH ZAC Im La 154.75 screws spaced 24 in.o.c. Approved Systems for GulfRib over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (pso OPTIONAL Min.29 a.GulfRib GulfRib T n e 4 attachment with#12-8 HWH Wood XG or insulation RIB-W-1 Min.7/16 OSB Approved fire barrier As required per FBC 36-inc hcoverage wood screws with sealing washers spaced 24 in.o.c. -22.66 Min. 15/32 OPTIONAL Min.29 ga.GUIfRIb GulfRib Type 3 attachment with#9-15 HWH wood screws RIB-W-2 CDX plywood Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 24 in.o.c. -56 or insulation GCS20002a FL33818 Page 5 of 7 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY&MANUFACTURING,LLC 42� CREEK Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for GulfRib over Wood Deck(New or Existing) System Fire Barrier/ MDP No. Deck Insulation Underlayment Roof Panel Panel Attachment (W Min.15/32 OPTIONAL Min.29 ga.GulfRib Gu/fRib Type 1 attachment with#with#9-15 HWH RIB-W-3 B-C plywood Approved fire barrier As required per FBC 36-inch coverage WoodZAC screws spaced 24 in.o.c -71.75 or insulation Min. 1x4 No.2 SYP wood purlins spaced OPTIONAL GulfRib GulfRib Type 1 attachment with#9-15 x 1 1/2"HWH wood RIB-W-4 24 in.o.c. Approved fire barrier As required per FBC Min.36-inc ga.h coverage screws with sealing washers spaced 24 in.o.c. -76.75 over or insulation into wood purlins Min.15/32 B-C plywood Min.1x4 No.2 SYP wood OPTIONAL GulfRib Type 1 attachment with#9-15 x 1 1/2"HWH wood RIB-W-5 purlins spaced Approved fire barrier As required per FBC Min.29 ga.GulfRib screws with sealing washers spaced 24 in.o.c. -101 24 in.o.c. or insulation 36-inch coverage into wood purlins over Min.7/16 OSB Min. 15/32 OPTIONAL Min.29 ga.GulfRib GulfRib Type 3 attachment with#9-15 HWH wood screws _101 RIB-W-6 CDX plywood Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 12 in.o.c. or insulation Min.1x4 No.2 SYP wood purlins spaced OPTIONAL Min.26 ga.GulfRib GulfRib Type 1 attachment with#9-15 HWH WoodZAC RIB-W-7 24 in.o.c. Approved fire barrier As required per FBC 36-inch coverage screws spaced 24 in.o.c.into wood purlins -106.75 over or insulation Min. 15/32 B-C plywood OPTIONAL Min.29 ga.GulfRib GulfRib Type 4 attachment with#12-8 HWH Woodgrip XG RIB-W-8 Min.7/16 OSB Approved fire barrier As required per FBC 36-inch coverage wood screws with sealing washers spaced 6 in.o.c. -116.0 or insulation GCS20002a FL33818 Page 6 of 7 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY&MANUFACTURING,LLC CREEKMetal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for GulfRib over Wood Deck(New or Existing) System Fire Barrier/ MDP No. Deck Insulation Underlayment Roof Panel Panel Attachment (psi Min. 1x4 No.2 SYP wood purlins spaced OPTIONAL GulfRib Type 2 attachment with#9-15 x 1 1/2"HWH wood RIB-W-9 24 in.o.c. Approved fire barrier As required per FBC Min.36-i nc ga.h coverage GulfRib screws with sealing washers spaced 24 in.o.c. -123.5 over or insulation e into wood purlins Min. 15/32 B-C plywood Min. 15/32 OPTIONAL Min.29 ga.GulfRib GulfRib Type 2 attachment with#9-15 HWH wood screws RIB-W-10 B-C plywood Approved fire barrier As required per FBC 36-inch coverage with sealing washers spaced 12 in.o.c. -146.0 or insulation Min. 15/32 OPTIONAL Min.26 ga.GulfRib GulfRib Type 2 attachment with#9-15 HWH WoodZAC RIB-W-11 B-C plywood Approved fire barrier As required per FBC 36-inch coverage screws spaced 12 in.o.c. -159.25 or insulation Min. 1x4 No.2 SYP wood purlins spaced OPTIONAL Min.26 ga.GulfRib GulfRib Type 1 attachment with#9-15 HWH WoodZAC RIB-W-12 12 in.o.c. Approved fire barrier As required per FBC 36-inch coverage screws spaced 12 in.o.c.into wood purlins -164.25 over or insulation Min. 15132 B-C plywood Approved Systems for GulfWave over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) Min.15/32 OPTIONAL Min.26 ga.GulfWave GulfWave Type 1 attachment with WAVE-W1 B-C plywood Approved fire As required per FBC 29-inch coverage #9-15 HWH wood screws with sealing washers -78.5 barrier or insulation spaced 24 in.o.c. GCS20002a FL33818 Page 7 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEKGULF COAST SUPPLY&MANUFACTURING, Roofing TECHNICAL SERVICES,LLC APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B,C, and D shall be as defined in section 1609 of the FBC. 3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis 6. Overhangs have been excluded from the analysis. 7. Wind directionality factor, Kd=0.85 8. Vuit is shown in the tables below. Design wind loads are calculated using Vnd=V„it�0.6 per 1609.3.1. 9. Zone 2 is inclusive of Zone 2e,Zone 2n,and Zone 2r 10. Zone 3 is inclusive of Zone 3e and Zone 3r 11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 12. Zones 1,2, and 3 shall be defined as shown below. Dimension"a"shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height),whichever is smaller, but not less than either 4%of the least horizontal dimension or 3ft Gable Hip X 3 2 3 3 2 3 a g 2 3 a 2 1 2 2 1 2 2 1 2 2 1 2 _ 1 3 2 3 3 2 3 a 3 2 3 a lal lalal lal IaI lal GCS20002a FL33818 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY&MANUFACTURING,LLC CREEK. Metal Roofing TECHNICAL SERVICES, LLG APPENDIX C Gable/Hip Roofs in Exposure B Roof slope between 2:12 and 12:12 Mean Basic Wind Speed mph) Building Type Zone Roof 120 130 140 160 160 170 180 190 200 Height ft 20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6 25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3 1 30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7 40 -31.2 1 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5 50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2 60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8 20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0 25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3 Enclosed/ 2 30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3 Partially Open 40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2 50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5 60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5 20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4 25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3 3 30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2 40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0 50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9 60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8 20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6 25 -32.1 -37.7 43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2 1 30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2 40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2 50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9 60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2 20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0 25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2 Partially 30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8 Enclosed 2 40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9 50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2 60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6 20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4 25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2 3 30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7 40 -59.3 -69.6 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7 50 -63.2 -74.2 1 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6 60 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.2 GCS20002a FL33818 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. t CREEKGULF COAST SUPPLY&MANUFACTURING,LLC + Metal Roofing TECHNICAL SERVICES, LLC APPENDIX C Gable/Hip Roofs in Exposure C Roof slope be 2:12 and 12:12 Mean Basic Wind Speed(mph)' Building`Type Zpne Roof 120 130 140 r 150 160 170 180 190 ', 200 Height ft 20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5 25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0 1 30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6 40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4 50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1 60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7 20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5 25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1 Enclosed/ 2 30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8 Partially Open 40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7 50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 -163.4 -181.0 60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7 20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6 3 30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5 40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3 50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2 60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1 20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9 25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2 1 30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5 40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5 50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2 60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5 20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9 25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3 Partially 30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7 Enclosed 2 40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8 50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1 60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5 20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1 25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7 3 30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4 40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4 50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2 60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 1 -244.9 GCS20002a FL33818 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. i GULF COAST SUPPLY&MANUFACTURING,LLC CREEKtad Metal Roofing TECHNICAL SERVICES, LLC APPENDIX C Gable/Hip Roofs in Exposure D Roof sloe between 2:12 and 12:12 Mean Basic Wind Speed ,n h Building Type Zone Roof Hei fit ft 120 130 140 150 160, 170 180 190 200 20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0 25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5 1 30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1 40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9 50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6 60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1 20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4 25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0 Enclosed/ 30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6 Partially Open 2 40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6 50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9 60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6 20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2 25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1 3 30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0 40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8 50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7 60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6 20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8 25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2 1 30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5 40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5 50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1 60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5 20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2 25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6 Partially 30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1 Enclosed 2 40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2 50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5 60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9 20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1 25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7 3 30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4 40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4 50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2 60 -102.2 -120.0 -139.1 -159.7 1 -181.7 -205.1 -230.0 -256.2 -283.9 GCS20002a FL33818 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.