HomeMy WebLinkAboutMANJCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:01 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 1 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Load Short Form Oct 16, 2020Date:(Rest of House)Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Briggs Residence, Groza Builders, IncFor: TBD Silver Oak Dr, Fort Pierce, FL 34982 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.6 Sensible cooling Btuh24220 Heating output Btuh26063 Latent cooling Btuh10380 Temperature rise °F21 Total cooling Btuh34600 Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.048 Air flow factor cfm/Btuh0.053 Static pressure in H2O0.85 Static pressure in H2O0.85 Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Foyer 58 1202 535 57 28 Master Suite 263 4183 3420 199 181 M Hall 20 0 0 0 0 Master Bath 113 1025 579 49 31 Linen 11 0 0 0 0 WIC 91 1911 752 91 40 Pantry 28 0 0 0 0 Laundry 64 2078 1422 99 75 Kit/DR/GR 684 5884 9476 280 502 Bath 61 583 318 28 17 Hall 54 0 0 0 0 Bed 2 135 1560 1241 74 66 Bed 3 143 1515 1278 72 68 WIC2 39 1168 420 56 22 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:01 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 2 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W WIC3 33 490 211 23 11 Bed 4 161 2647 2100 126 111 (Rest of House)1956 24245 21752 1153 1153 Other equip loads 1818 966 Equip. @ 0.95 RSM 21673 Latent cooling 7522 TOTALS 1956 26063 29195 1153 1153 2021-Apr-01 09:39:01 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 1 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Building Analysis Oct 16, 2020Date:(Rest of House)Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Briggs Residence, Groza Builders, IncFor: TBD Silver Oak Dr, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 18.047012.6Walls 4.211019.3Glazing 0.61543.7Doors 7.419311.0Ceilings 25.466233.43.4Floors 13.234402.1Infiltration 24.26294Ducts 00Piping 00Humidification 7.01818Ventilation0Adjustments 100.026063Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 12.728781.6Walls 6.1139111.7Glazing 0.71563.7Doors 15.535161.8Ceilings 000Floors 4.29610.6Infiltration 31.07050Ducts 4.3966Ventilation 25.55800Internal gains 00Blower 0Adjustments 100.022718Total Latent Cooling Load = 7522 Btuh Overall U-value = 0.085 Btuh/ft²-°F Data entries checked. 2021-Apr-01 09:39:02 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 1 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Component Constructions Oct 16, 2020Date:(Rest of House)Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Briggs Residence, Groza Builders, IncFor: TBD Silver Oak Dr, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Block R-9 Wall: Blk wall, Stuc Ext, 8" thk, R-9 Foam Fill, 1/2" Gyp Bd 12332.589.00.089479n 7891.65 5801.659062.589.00.089352e 451.65702.589.00.08927se 8011.6512532.589.00.089486s 2161.653382.589.00.089131w 24301.6538002.589.00.0891475all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 4471.469012.9411.00.101307 Windows Non-Impact: Non-Impact; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.25 ft window ht, 1 ft sep.); 6.8 ft head ht 1237.591509.2800.32016n 1767.592159.2800.32023n 37323.01509.2800.32016e 1589.741509.2800.32016s 82911.66669.2800.32072all Non-Impact: Non-Impact; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 9 ft overhang (5.25 ft window ht, 1 ft sep.); 6.8 ft head ht 2149.592079.2800.32022se Non-Impact: Non-Impact; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (0.67 ft window ht, 1 ft sep.); 6.8 ft head ht 169.04137.5400.2602s Non-Impact: Non-Impact; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 5.3 ft overhang (5.25 ft window ht, 1 ft sep.); 6.8 ft head ht 33214.32159.2800.32023w Doors Fbrgls Door 673.73663.697.00.12718s 893.73893.697.00.12724w 1563.731543.697.00.12742all Ceilings Attic, Shngl Roof, R-30 Ceil Ins, 5/8" Gyp Bd 0.0341956 35161.8019310.9930.0 2021-Apr-01 09:39:02 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 2 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W Floors On Grade Depth, Tile Flr Fnsh 00662328.700.989231 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 1 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Project Summary Oct 16, 2020Date:(Rest of House)Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Briggs Residence, Groza Builders, IncFor:TBD Silver Oak Dr, Fort Pierce, FL 34982 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh17951 Structure Btuh14702 Ducts Btuh6294 Ducts Btuh7050Central vent (57 cfm) 1818 Btuh Central vent (57 cfm) Btuh966 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh26063 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh21673 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3195 Ducts Btuh2122Central vent (57 cfm) Btuh2205 CoolingHeating Outside air19561956Area (ft²) Equipment latent load Btuh7522 1704317043Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh29195 Equiv. AVF (cfm) 57108 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond ML14XC1S036-230C**AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.6 Sensible cooling Btuh24220Heating output Btuh26063 Latent cooling Btuh10380 Temperature rise °F21 Total cooling Btuh34600Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.048 Air flow factor cfm/Btuh0.053Static pressure in H2O0.85 Static pressure in H2O0.85 Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 1...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name (Rest of House)Foyer 2 Exposed wall 230.9 ft 12.0 ft 3 Room height 8.7 ft 8.5 heat/coolft 4 Room dimensions ft11.5x5.0 5 Room area 1955.6 ft²57.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 518 479 1233 789 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 16 0 150 123 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 23 0 215 176 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 368 352 906 580 0 0 0 0 11 GG Non-ImpactNon-Impact 0.3200.320 ee 9.289.28 23.0223.02 16 0 150 373 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 49 27 70 45 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 sese 9.289.28 9.599.59 22 22 207 214 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 522 486 1253 801 0 0 0 0 GG Non-ImpactNon-Impact 0.2600.260 ss 7.547.54 9.049.04 2 2 13 16 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ss 9.289.28 9.749.74 16 14 150 158 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 18 18 66 67 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 178 131 338 216 38 14 37 23 GG Non-ImpactNon-Impact 0.3200.320 ww 9.289.28 14.3214.32 23 15 215 332 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ww 3.693.69 3.733.73 24 24 89 89 24 24 89 89 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 307 307 901 447 64 64 187 93 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 1956 1956 1931 3516 58 58 57 103 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 1956 231 6623 0 58 12 344 0 6 c) AED excursion 0 -11 Envelope loss/gain 14511 7941 713 298 12 a) Infiltration 3440 961 80 22 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 5 1150 0 0 Appliances/other 4650 0 Subtotal (lines 6 to 13)17951 14702 794 321 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 96 41 14 Subtotal 17951 14702 890 361 15 Duct loads 35%48%6294 7050 35%48%312 173 Total room load 24245 21752 1202 535 Air required (cfm)Air required (cfm)1153 1153 57 28 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 2...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Suite M Hall 2 Exposed wall 40.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft15.0x17.5 ft4.5x4.5 5 Room area 262.5 ft²20.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 64 64 165 105 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG Non-ImpactNon-Impact 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 sese 9.289.28 9.599.59 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 120 120 309 198 0 0 0 0 GG Non-ImpactNon-Impact 0.2600.260 ss 7.547.54 9.049.04 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ss 9.289.28 9.749.74 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 140 117 301 192 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ww 9.289.28 14.3214.32 23 15 215 332 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 263 263 259 472 20 20 20 36 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 263 41 1162 0 20 0 0 0 6 c) AED excursion 312 -1 Envelope loss/gain 2411 1612 20 35 12 a) Infiltration 681 190 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)3092 2303 20 35 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 9 -20 -35 14 Subtotal 3097 2312 0 0 15 Duct loads 35%48%1086 1108 35%48%0 0 Total room load 4183 3420 0 0 Air required (cfm)Air required (cfm)199 181 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 3...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Bath Linen 2 Exposed wall 9.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft113.0x1.0 ft3.5x3.0 5 Room area 113.0 ft²10.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG Non-ImpactNon-Impact 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 sese 9.289.28 9.599.59 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 76 74 191 122 0 0 0 0 GG Non-ImpactNon-Impact 0.2600.260 ss 7.547.54 9.049.04 2 2 13 16 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ss 9.289.28 9.749.74 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ww 9.289.28 14.3214.32 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 113 113 112 203 11 11 10 19 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 113 10 272 0 11 0 0 0 6 c) AED excursion -13 -1 Envelope loss/gain 589 329 10 18 12 a) Infiltration 160 45 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)749 373 10 18 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 10 18 -10 -18 14 Subtotal 759 391 0 0 15 Duct loads 35%48%266 188 35%48%0 0 Total room load 1025 579 0 0 Air required (cfm)Air required (cfm)49 31 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 4...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name WIC Pantry 2 Exposed wall 20.0 ft 5.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft7.0x13.0 ft5.0x5.5 5 Room area 91.0 ft²27.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 104 104 268 171 0 0 0 0 11 GG Non-ImpactNon-Impact 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 sese 9.289.28 9.599.59 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 56 56 144 92 0 0 0 0 GG Non-ImpactNon-Impact 0.2600.260 ss 7.547.54 9.049.04 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ss 9.289.28 9.749.74 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ww 9.289.28 14.3214.32 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 44 44 129 64 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 91 91 90 164 28 28 27 49 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 91 20 574 0 28 6 158 0 6 c) AED excursion -17 -4 Envelope loss/gain 1076 410 314 110 12 a) Infiltration 336 94 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1412 504 314 110 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 2 4 -314 -110 14 Subtotal 1415 508 0 0 15 Duct loads 35%48%496 244 35%48%0 0 Total room load 1911 752 0 0 Air required (cfm)Air required (cfm)91 40 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 5...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Laundry Kit/DR/GR 2 Exposed wall 24.0 ft 44.4 ft 3 Room height 8.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft8.0x8.0 ft684.4x1.0 5 Room area 64.0 ft²684.4 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 64 64 165 105 190 167 430 275 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 23 0 215 176 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 64 64 165 105 0 0 0 0 11 GG Non-ImpactNon-Impact 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 49 27 70 45 GG Non-ImpactNon-Impact 0.3200.320 sese 9.289.28 9.599.59 0 0 0 0 22 22 207 214 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 70 52 134 86 GG Non-ImpactNon-Impact 0.2600.260 ss 7.547.54 9.049.04 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ss 9.289.28 9.749.74 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 18 18 66 67 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ww 9.289.28 14.3214.32 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 64 64 188 93 135 135 397 197 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 64 64 63 115 684 684 676 1230 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 64 24 688 0 684 44 1274 0 6 c) AED excursion -33 -219 Envelope loss/gain 1269 386 3469 2071 12 a) Infiltration 269 75 651 182 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 5 1150 Appliances/other 500 2900 Subtotal (lines 6 to 13)1539 961 4119 6303 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 237 102 14 Subtotal 1539 961 4356 6405 15 Duct loads 35%48%539 461 35%48%1528 3071 Total room load 2078 1422 5884 9476 Air required (cfm)Air required (cfm)99 75 280 502 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 6...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath Hall 2 Exposed wall 5.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft5.5x11.0 ft13.5x4.0 5 Room area 60.5 ft²54.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG Non-ImpactNon-Impact 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 sese 9.289.28 9.599.59 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 44 44 113 73 0 0 0 0 GG Non-ImpactNon-Impact 0.2600.260 ss 7.547.54 9.049.04 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ss 9.289.28 9.749.74 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ww 9.289.28 14.3214.32 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 61 61 60 109 54 54 53 97 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 61 6 158 0 54 0 0 0 6 c) AED excursion -7 -3 Envelope loss/gain 331 174 53 94 12 a) Infiltration 93 26 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)423 200 53 94 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 8 15 -53 -94 14 Subtotal 432 215 0 0 15 Duct loads 35%48%151 103 35%48%0 0 Total room load 583 318 0 0 Air required (cfm)Air required (cfm)28 17 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 7...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Bed 3 2 Exposed wall 13.5 ft 13.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft13.5x10.0 ft13.0x11.0 5 Room area 135.0 ft²143.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 108 92 237 151 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 16 0 150 123 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG Non-ImpactNon-Impact 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 sese 9.289.28 9.599.59 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 104 88 226 145 GG Non-ImpactNon-Impact 0.2600.260 ss 7.547.54 9.049.04 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ss 9.289.28 9.749.74 0 0 0 0 16 14 150 158 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ww 9.289.28 14.3214.32 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 135 135 133 243 143 143 141 257 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 135 14 387 0 143 13 373 0 6 c) AED excursion -28 -28 Envelope loss/gain 907 489 891 532 12 a) Infiltration 227 63 219 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 250 Subtotal (lines 6 to 13)1134 802 1109 843 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 21 36 12 21 14 Subtotal 1155 839 1121 864 15 Duct loads 35%48%405 402 35%48%393 414 Total room load 1560 1241 1515 1278 Air required (cfm)Air required (cfm)74 66 72 68 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 8...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name WIC2 WIC3 2 Exposed wall 12.5 ft 5.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.5x6.0 ft6.5x5.0 5 Room area 39.0 ft²32.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.3200.320 nn 9.289.28 7.597.59 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 48 48 124 79 40 40 103 66 11 GG Non-ImpactNon-Impact 0.3200.320 ee 9.289.28 23.0223.02 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 sese 9.289.28 9.599.59 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 52 52 134 86 0 0 0 0 GG Non-ImpactNon-Impact 0.2600.260 ss 7.547.54 9.049.04 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ss 9.289.28 9.749.74 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3200.320 ww 9.289.28 14.3214.32 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 39 39 39 70 33 33 32 58 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 39 13 359 0 33 5 143 0 6 c) AED excursion -10 -5 Envelope loss/gain 655 225 279 119 12 a) Infiltration 210 59 84 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)865 284 363 143 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 865 284 363 143 15 Duct loads 35%48%303 136 35%48%127 69 Total room load 1168 420 490 211 Air required (cfm)Air required (cfm)56 22 23 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-01 09:39:02Right-Suite® Universal 2021 21.0.05 RSU29066 Page 9...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Right-J® Worksheet Oct 16, 2020Date:(Rest of House)Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 4 2 Exposed wall 25.5 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft11.5x14.0 5 Room area 161.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Block R-9 Wall 0.089 n 2.58 1.65 92 92 237 152 .G Non-Impact 0.320 n 9.28 7.59 0 0 0 0 .G Non-Impact 0.320 n 9.28 7.59 0 0 0 0 .W Block R-9 Wall 0.089 e 2.58 1.65 112 96 247 158 11 G Non-Impact 0.320 e 9.28 23.02 16 0 150 373 W Block R-9 Wall 0.089 se 2.58 1.65 0 0 0 0 G Non-Impact 0.320 se 9.28 9.59 0 0 0 0 W Block R-9 Wall 0.089 s 2.58 1.65 0 0 0 0 G Non-Impact 0.260 s 7.54 9.04 0 0 0 0 G Non-Impact 0.320 s 9.28 9.74 0 0 0 0 D Fbrgls Door 0.127 s 3.69 3.73 0 0 0 0 W Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 G Non-Impact 0.320 w 9.28 14.32 0 0 0 0 D Fbrgls Door 0.127 w 3.69 3.73 0 0 0 0 P Frm Wall, 1/2" Gyp B 0.101 -2.94 1.46 0 0 0 0 C Attic, Shngl Roof, R 0.034 -0.99 1.80 161 161 159 289 F On Grade Depth, Tile 0.989 -28.68 0.00 161 26 731 0 6 c) AED excursion 67 Envelope loss/gain 1524 1039 12 a) Infiltration 429 120 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 250 Subtotal (lines 6 to 13)1953 1409 Less external load 0 0 Less transfer 0 0 Redistribution 6 11 14 Subtotal 1960 1420 15 Duct loads 35%48%687 681 Total room load 2647 2100 Air required (cfm)126 111 2021-Apr-01 09:39:03 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 1 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Duct System Summary Oct 16, 2020Date:(Rest of House)Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Briggs Residence, Groza Builders, IncFor: TBD Silver Oak Dr, Fort Pierce, FL 34982 CoolingHeating External static pressure in H2O0.85in H2O0.85 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.85in H2O0.85 Supply / return available pressure 0.525 / 0.325 in H2O in H2O0.525 / 0.325 Lowest friction rate in/100ft0.281in/100ft0.281 Actual air flow cfm1153cfm1153 Total effective length (TEL) ft302 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st2100.037.6VlFx0x04.00.3812033583hBath st2100.037.0VlFx0x05.00.38379891560hBed 2 st2100.039.3VlFx0x05.00.37781861515hBed 3 st4125.056.8VlFx0x07.00.2891341512647hBed 4 st3110.039.0VlFx0x05.00.35234691202hFoyer st195.014.5VlFx0x06.00.480151842369cKit/DR/GR st3110.044.9VlFx0x07.00.339151842369cKit/DR/GR-A st2100.037.4VlFx0x06.00.382151842369cKit/DR/GR-B st2100.036.9VlFx0x06.00.384151842369cKit/DR/GR-C st195.011.9VlFx0x06.00.491901192078hLaundry st3110.036.9VlFx0x05.00.35737581025hMaster Bath st3110.031.5VlFx0x06.00.3711091192092hMaster Suite st3110.039.3VlFx0x06.00.3521091192092hMaster Suite-A st3110.041.6VlFx0x06.00.346481091911hWIC st4125.061.8VlFx0x05.00.28127671168hWIC2 st4125.056.3VlFx0x04.00.2901328490hWIC3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 203 241 0.480 903 7.0 0x0 VinlFlx st4 Peak AVF 246 174 0.281 704 8.0 0x0 VinlFlx st2 st2 Peak AVF 622 656 0.281 835 12.0 0x0 VinlFlx st3 Peak AVF 559 487 0.339 712 12.0 0x0 VinlFlx Bold/italic values have been manually overridden 2021-Apr-01 09:39:03 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 2 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb5 0x 1790 147 115.6 0.281 405 9.0 x0 0 VlFx rt1 rb3 0x 1530 108 105.8 0.307 573 7.0 x0 0 VlFx rt1 rb4 0x 890 79 101.3 0.321 255 8.0 x0 0 VlFx rt1 rb1 0x 3480 265 49.7 0.653 443 12.0 x0 0 VlFx rb2 0x 6150 784 98.8 0.329 562 16.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 1036 1119 0.281 633 18.0 0x0 VinlFlx 2021-Apr-01 09:39:03 Right-Suite® Universal 2021 21.0.05 RSU29066 Page 1 ...ghtsoft HVAC\TBD Silver Oak Ft. Pierce, GBI.rup Calc = MJ8 Front Door faces: W 1347Job:Manual S Compliance Report Oct 16, 2020Date:(Rest of House)Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Briggs Residence, Groza Builders, IncFor: TBD Silver Oak Dr, Fort Pierce, FL 34982 Cooling Equipment Design Conditions °F76.9Entering coil DB:Btuh22718Sensible gain:°F90.4Outdoor design DB: °F64.1Entering coil WB:Btuh7522Latent gain:°F77.4Outdoor design WB: Btuh30240Total gain:°F75.0Indoor design DB: cfm1153Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: ML14XC1S036-230C**+CBA27UHE-036-230*++TDRModel:LennoxManufacturer: cfm1153Actual airflow: % of load107Btuh24220Sensible capacity: % of load138Btuh10380Latent capacity: %70SHR:% of load114Btuh34600Total capacity: Heating Equipment Design Conditions °F68.0Entering coil DB:Btuh26063Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm1153Actual airflow: °F50Temp. rise:% of load100kW7.6Output capacity: Meets all requirements of ACCA Manual S. Job #: 1347 Performed by Chris Bateman for: Briggs Residence TBD Silver Oak Dr Fort Pierce, FL 34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 178 Page 1 Right-Suite® Universal 2021 21.0.05 RSU29066 2021-Apr-01 09:39:32 ...D Silver Oak Ft. Pierce, GBI.rup N Level 1 Garage Foyer Master Suite M Hall Master Bath Linen WIC Pantry Laundry Kit/DR/GR Bath Hall Bed 2 Bed 3 WIC2 WIC3 Bed 4 12 x 12 348 cfm 10 x 6 69 cfm 10 x 6 119 cfm 6 x 6 58 cfm 10 x 6 109 cfm 10 x 10 151 cfm 10 x 6 86 cfm 10 x 6 89 cfm 12 x 8 151 cfm 30 x 18 784 cfm 12 x 12 153 cfm 12 x 12 89 cfm 8 x 4 28 cfm 10 x 6 67 cfm 10 x 10 119 cfm 10 x 10 119 cfm 10 x 10 151 cfm 10 x 10 151 cfm 10 x 10 151 cfm 12 x 12 179 cfm 9 " 8 " 8 " 7 " 6 "7 " 5 " 6 " 4 " 6 " 5 " 6 " 6 " 6 " 18 " 7 " 12 " 12 " 5 " 6 " 12 " 5 " 5 " 7 " 4 " 6 x 6 33 cfm 4 " 6 " 120 CFM 6"Duct 6"Exhaust Vent H/W DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE