DETAIL DIAGRAM MODEL 1540-520 DUAL FUNCTION FLOOD AND VENTILATION VENT V-4 1/4' R/O CUP SLOTS USE TWO TOP AND TWO BOTTOM BEHIND THE RODENT SCREEN. LOWERS AUTOMATICALLY OPEN AND CLOSE WITH 8 1/4- TEMPERATURE. NO ELECTRICITY IS NEEDED R/O ° 4. v.. ° a d' FLOAT SLOTS FIGURE 1 FRONT VIEW HURRIBOND GRIP k SEAL ADHESIVE LOCATION (FLANGE) • a 12" MAX FROM v FIGURE 3 FINAL GRADE INSTALLED: TWO ON SIDE VIEW _---CUPS VENT TOP TWO ON BOTTOM '. ° DOOR VENT SMART VENT Foundation Food Vents 1' -0.. NEW JAMES HARDI SIDING ON 1 LAYER OF TY-VEL ON EXIST PLYWD FL-13192.4 OOD abs @ EXIST VINYL SIDING TO BE REMOVED NEW P.T. 2 x 4 TOP AND BOTT NEW FEMA 1540 -520 SMART FLOOD VENT 200 S.F PER VENT 0 FLOOD VENT SECTION NEW FASCIA TO MATCH EXIST. SIMPSONLUS24 HANGER W/ 4 - 0.148 x 3" INTO RAFTER 61 2-.0148 x 3" INTO 2 x 4 SCREEN ENCLOSURE 2-2 x 12 WOOD BEAM Smart VENT 877— 441 — 8368 www.smartvent.com INSTALLATION INSTRUCTIONS & DETAILS MODEL 1540-520 DUAL FUNCTION FLOOD AND VENTILATION VENT REV. 8-21-18 I. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE BOTTOM Of DOOR DUIWN20 AND SLIDE OUT) 2. PREPARE A CLEAN 18.25' WIDE BY 8.25' HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE THAN 12' ABOVE THE FINISHED GRADE. 3. APPLY A BEAD OF HURRIBOND GRIP g SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE VENT FRAME. (FIG. 2) 4. INSERT INSTALLATION CUPS INTO THE TWO SLOTS ON THE TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME. 5. THE SPRING ARM OF THE CLIPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME. COMPRESS THE BOTTOM TWO CUPS AND BEGIN SLIPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CUPS ARE IN THE OPENING BEFORE ALLOW THEM TO DECOMPRESS. 6. WITH THE FRAME NOW IN THE OPENING, AND THE BOTTOM SPRINGS IN PLACE, COMPRESS THE TOP SPRINGS AND PUSH THE VENT FRAME INTO THE OPENING COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL. 7. RE -CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK. S. INSTALL THE DOOR INTO FRAME BY GRASPING THE BOTTOM OF DOOR (WITH FLOAT PITS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SUDS DOOR INTO FRAME AND NEW ASPHAL ROTATE UNTIL R IS LATCHED. TO MATCH E) S. INSERT THE TOP STRAPS INTO THE TOP TWO STRAP SLOTS ABOUT TWO CLICKS. 10. TO OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING. DETAILED SPECIFICATIONS MATERIAL• STAINLESS STEEL ESP ALUM OPERATION FLOOD: AUTOMATIC NON -POWERED ACTUATION AND OPERATION W/ NO SEE VENT REMAINS CLOSED AND LOCKED UNTIL ACTIVATED OPERATION AIR: AUTOMATIC LOUVERS FULLY OPEN AT 75 DEG. FULLY CLOSED AT 35 DEG. NO POWER REQUIRED INsrat.unoN: NEW 4 x SECURED W/ 4 STAINLESS STEEL INSTALLATION CLIPS INCLUDED AND AN ADHESVE HYDROSTATIC RELIEF: 200 50. FT PER VENT VENTILATION! 51 SD. IN. PER VENT NOTE VAPOR BARRIER ALLOWS FOR REDUCED VENTILATION REQUIREMENTS FLOOD: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS COLORS: STAINLESS (STANDARD) EXTERIOR POWDER COATED WHRE, WHEAT, GRAY, AND BLACK (AVAILABLE) MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY: FEMA, NFIP, ICC, k ASCE SUPPORTIVE DOCUMENTS, TB 1-08, 44CFR 60.3(C)(5), ASCE 24-14 ICC EVALUATION # ESR-2074 SECTION 11 D11 SECTION 11 C 11 Y4"=1' -0" Y4"d'-O" SIMPSONLU524 HANGER - 0.148 x 3" INTO RAFTER )148 x 3" INTO 2 x 4 WOOD BDS @ I.C. NEW FASCIA TO MATCH EXIST. K 8 WOOD RAFTERS 16" O.C. 1100 PSI SCREEN ENCLOSURE SHEET2 OF 2 EN ENCLOSURE SCREEN POST 3'-0" NEW FEMA FLOOD VENTvt NEW HORIZ HARDI BD SIDING ELEVATION 4 "=1 -0" NEW METAL ROOF O� r-1 i W � N t` W FRONT W AA•� h� W r a Q Q M a U • a N = a W a A as d Q O a ESP ALUM SCREEN ENCLOSURE W/ NO SEE UM SCREEN NEW HARDI BD. SIDING o NEW 36" HGT. ALUM RAILING O - NEW 4 x 4 WOOD POST 40 C• r. Q w 94 U LEFT SIDE ELEVATION z r` lil EXIST DOOR _ �+ W IEU RQCC a H 114fl7[V i— EXIST DOOR NEW 36" HGT. ALUM RAILING RIGHT SIDE ELEVATION NEW HORIZ HARDI BD SIDING Y4'=1'-0" NEW 34" HGT. ALUM RAILING No 520q S/oN�JL j LNG �� 0 Fhw i A�v1 QO U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2022 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A— PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: CHRISTOPHER AND SUSAN FOTOS A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 2010 NETTLES BOULEVARD City State ZIP Code JENSEN BEACH Florida Q 34957 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 10, NETTLES ISLAND SECTION 1 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) A5. Latitude/Longitude: Let. 27°17'08.78" N Long. 80°12'51.62" W Horizontal Datum: ❑ NAD 1927 x❑ NAD 1983 A6. Attach at least 2 photographs of the building If the Certificate is being used to obtain flood insurance. AT Building Diagram Number 8 0 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 880.0 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 5 c) Total net area of flood openings in A8.1b 1000.0 sq In d) Engineered. flood openings? ❑x Yes ❑ No A9. For a building with an attached garage: a) Square footage of attached garage 0.0 sq ft b) Number of permanent flood openings in the attached garage. within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A9.b 0.0 sq in d) Engineered flood openings? ❑ Yes ❑x No i SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 81. NFIP Community Name & Community Number B2. County Name B3. State UNINCORP / j20265 ST. LUCIE Florida B4. Map/Panel .B5. Suffix B6. FIRM Index B7. FIRM Panel B6. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 12111C 0312 K 02/19/2020 02/19/2020 AE 4.0 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: Z.610 N I, s ouc ryv 2t City State ZIP Code Company NAIC Number I�A5Ir-A1 6CEA' E—H R_ o -34157 SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ❑x Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations —Zones Al—A30, AE, AH, A (with BFE), VE, VI—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: 94 77 A04 FLDT Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below, ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 4.10 ❑x feet ❑ meters b) Top of the next higher floor 7.86 0 feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑ feet ❑ meters d) Attached garage (top of slab) N/A ❑ feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building S.02 ❑x feet ❑meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 4.01 0 feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 4.05 Z feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 4.10 ❑x feet ❑ meters structural support SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information, t certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? 0 Yes ❑ No ❑ Check here if attachments. Certifier's Name License Number �'`3 ) Zb �' Ga s. EARLE R. STARKEY 004459 Title PROFESSIONAL LAND SURVEYOR Ce Company Name ACCURIGHT LAND SURVEYING, INC. _ " Address 1501 S.E. DECKER AVENUE, UNIT 419D '-�-�� O Z3 JZaLI City State ZIP Code Florida 34994 )7�.$ {¢- 004y4 S' Date Telephone Ext. 03/23/2021 (772)286-7694 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) Insurance agent/oompany, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) A8(d) 5 FLOODVENTS MODEL NUMBER 1540-520 (200 SQUARE INCHES EACH) C2(e) A/C PAD FEMA Form 086-0-33. (12119) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANYUS€ BUllding Street Address (including Apt., Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: �Unit, rrrLiiS I—)c)ULiIVAt2J 2oic9 N ; r City .I 2 State ZIP Code 3H01S7 Company NAIC Number JI'z.✓v5rC ACi4 I-` 0 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items El—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is [:]feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is [:]feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑feet ❑ meters ❑ above or ❑below the HAG. E5, Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F—PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding Information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 77-010 N iiTTL17ES 1330uL_C- r, City State ZIP Code Company NAIC Number J i z i�.t 5 IF '4 Li e- i-I F- - 3 3 y c) S 7 SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8-G10. In Puerto Rico only, enter meters. 31. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BF€) or Zone AO. G3. ❑ The following information (Items G4-G10) is provided for community floodplain management purposes. G4. Permit Number G6. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name - Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 4 of 6 BUILDING PHOTOGRAPHS OMB No, 1660.0006 ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copythe corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address Qncluding Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number. 2010 NETTLES BLVD, City state ZIP code Company NAIC Number JENSEN BEACH FLORIDA El 34957 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the Instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section AS, If submitting more photographs than will fit on this page, use the Continuation Page. M l lily �tglr lt♦4s w'M Photo One Caption FRONT 03/23/2021 Clear Photo One z - urr': t PMm TM Photo Two Caption REAR 03/23/2021 clesirPa°`°T"'° FEMA Form 036-0-33 (12/19) Replaces all previous editions. Form Page 5 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Page Expiration Date. November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2010 NETTLES BLVD, City State ZIP Code Company NAIC Number JENSEN BEACH FLORIDA 34957 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and 'Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section AB. I - hot. Th. Photo Three Caption RIGHT SIDE 03/23/2021 Clear Photo Three a -- ..: Frt b Four Photo Four Caption Cie* Photo Four FEMA Form 08"-33 (12119) Replaces all previous editions. Form rage o or o DIVISION: 08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 EVALUATION SUBJECT: SMART VENT° AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 1CC clC F ICL C ! STEo Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPQ Award in Excellence" A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a t recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as . — to any fording or other matter in this report, or as to any product covered by the report. reoomr�n�w� ccx Copyright © 2016 [CC Evaluation Service, LLC. All rights reserved. n `o N m `0 d E_ )m C � LEE dv $� -O N y 3 d¢ E L>> P L C Y y C G C y L O L Q C N— 0- � w> N 0 0 V G c H m $ V ° U o do rnN E$° oLL ELm y C •N W L 'O m y U1 ^ W �0 id °a o zp®E—°�� oT`Nm�p >Rym c z t: E E E U° � V> O a U d O •- = n N W @ t O N N O �00 H > O Na m LU �g� m Q o N '- E W ,C (D u) >i � n 0 f0 T 0 0 m N 0 w N° E y >.L ° u C 'o- > ma E L^ o c_ o o° m `oE ov °� a mo°d E C O m N L co °O. L O E y a IO d 0 a U L C y l/1 UI N A U E o >>o $3" @mac LLn°O ) o o o•y N O y W vVi N y L = O 0 E 'E oE�v>> rn m .>_ yf°o p c° E,6mc O LLL20, @._Ccy md•ic °moa W 000 0O > E.L°. M 0 O O d y U Z C O G 0 L .- 'C y✓ C CoU v L YLON a ~ �'=�U pp C m !n OC C N Z E N N N L m V 0 O yoy3 Cm F•�Em m> r O) O V N y 0 ■ ■ L 0 0 O f- O U o r r- LfI N x P W (g O o O 0 O 0 O 0 O 0 O 0 O 0 O 0 ui ui U C iv io ro X X X X X X X X J W ``> `e `e t0 (O l° LO r LL] t° r r o K W 7 N Z o lfJ 0 0 1n 0 6 6 t) 6 IN 6 J C r r LO O O a v d W p 0 O o inO N > p Co Z Z J W L E > > y 0 0 O O ® F- LL a: ®U F U `Z W W W O A W N 0 m 0 w 0 0 m a o u. E (ALL o E 0> O >> O UJ o LL rE 8