Loading...
HomeMy WebLinkAbout2102-0198 COMMENTSPlmning & Development Services Building 8 Code Regulation Divi3ion 2300 Vlrglnla Avenue Fork Pierce, FL. 34962 Address: 5512 Pinetree Dr City / State / Zip: Fort Pierce, FI 34982 Parcel #: 3402-602-0283-000/8 Zoning: RS-3 APPLICATION INFORMATION Permit Number: 2102-0198 Permit Type: BUILD RESID ADDITION CONTRACTOR INFORMATION Contractor Name: Harold D Roberts Business Name: Detailed Enterprises Inc Business Addr: 565 Nw Cornell Ave City / State / Zip: Port St Lucie, FI 34983 REVIEW COMMENTS Q Owner(s): John Paul Edgar Jurisdiction: SAINT LUCIE COUNTY Lot#: 16 Block: 8 Stories: Automatic Sprinkler System? No Fax Number: Email: Deanroberts2009@Gmail.0 om REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 2/8/2021 Comment: NEEDS NOC 2/8/2021 Comment: NEEDS A/C SUB ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel 2/16/2021 2/24/2021 2/24/2021 Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 2/8/2021 2/8/2021 2/8/2021 Comment: NOTIFIED FOR PICK UP PENDING Comment: PLANS EXAMINER REVIEW INCOMPLETE Jpi, Inc -Andrew 2/22/2021 2/22/2021 Comment: 1) DRAWINGS ARE NOT SIGNED. DIGITAL SIGNATURES CAN NOT BE PRINTED. ([All 07) 2/22/2021 Comment: 2) PROVIDE THE CONNECTION OF RIM JOIST TO PIERS. ([A]107.2.1) 2/22/2021 Comment: 3) PLEASE IDENTIFY THE SIZE OF EACH FLOOR MEMBER. ([A]107.2.1) 2/22/2021 Comment: 4) PROVIDE THE PRODUCT APPROVALS FOR THE SIDING & SOFFIT. ([A]107.2.1) Comment: 5) PLEASE PROVIDE SPACING OF FLOOR JOISTS, FLOOR SHEATHING MATERIAL, AND DESCRIBE HOW 2/22/2021 THE FLOOR SHEATHING IS ATTACHED TO THE FLOOR JOISTS. VERIFY JOIST SIZE ON PLANS, BOTH 2X8 AND 2X10 ARE CALLED OUT IN DIFFERENT LOCATIONS (2X8 @ 1/A2). ([All 07.2.1) 2/22/2021 Comment: 6) PROVIDE HEADER SIZE OVER LARGE WINDOW OPENING. Plinning&DeveloMentservices REVIEW COMMENTS Building 8 Code Regulation Divi3ion 2300 Vlrglnla Avenue Fork PICMD, FL. 34962 2/2212021 Comment: 7) PROVIDE ROOF FRAMING DETAILS, PROVIDE DETAILS FOR THE CONNECTION TO EXISTING STRUCTURE. ([A]107.2.1) 2/22/2021 Comment: 8) PROVIDE LOCATION OF CONDENSER & RECEPTACLE AT CONDENSER. ([All 07.2.1) 2/22/2021 Comment: 9) PROVIDE ELECTRIC LOAD CALCULATIONS, VERIFY EXISTING SERVICE WILL ACCOMMODATE NEW LOADS. ([All 07.2.1) 2/22/2021 Comment: 10) NO PLUMBING RISER PROVIDED.([A]107.2.1) Comment: 11) ENERGY FORM 2/22/2021 -PLEASE USE THE CURRENT ENERGY FORM. -EXTERIOR WALL IS NOT MASONRY PER PLANS. -HVAC IS SHOWN AS EXISTING. ZONING REVIEW INCOMPLETE Angela Vassar 2/12/2021 Comment: PLEASE SUBMIT TWO CORRECTED SEALED SURVEYS SHOWING THE BREEZEWAY AND PROPOSED 2/12/2021 PLAYROOM, BATHROOM AND LAUNDRY ROOM. PLEASE ASK THE SURVEYOR TO SHOW THE SEPTIC AND DRAINFIELD.