Loading...
HomeMy WebLinkAboutRESPONSE TO COMMENTSouNEF,5 John Paul Edgar SS12 Pine Tree Drive Fort Pierce, Florida F,:IE &FOI &E TO COt-T-1`E I T,5 Review Type Status Reviewed By Date Started Dale Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 21812021 Comment: NEEDS NOC 21812021 Comment: NEEDS AJC SUB ENVIRONMENTAL REVIEW COMPLETE Lynn Swarizel 2/16/2021 2/24/2021 2/24/2021 Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 21812021 21812021 2/8/2021 Comment: NOTIFIED FOR PICK UP PENDING Comment: PLANS EXAMINER REVIEW INCOMPLETE Jpi, Inc -Andrew 212212021 2/2212021 Comment: 1) DRAWINGS ARE NOT SIGNED. DIGITAL SIGNATURES CAN NOT BE PRINTED. (IA]107) RESPONSE: DRAWINGS WILL BE SIGNED AND RE -SUBMITTED AS REQUESTED. 2/2212021 Comment: 2) PROVIDE THE CONNECTION OF RIM JOIST TO PIERS. ([A]107.2.1) RESPONSE: ADD DETAIL SHOWING CONNECTION OF RIM JOIST TO PIERS. SEE SHEET A-4 212212021 Comment: 3) PLEASE IDENTIFY THE SIZE OF EACH FLOOR MEMBER. ([A]107.2.1) RESPONSE. ADD IDENTIFICATION SIZE TO EACH FLOOR MEMBER SEE SHEET A2 22212021 Comment: 4) PROVIDE THE PRODUCT APPROVALS FOR THE SIDING & SOFFIT. ([A]107.2.1) RESPONSE: ADD PRODUCTAPPROVAL FOR SIDING & SOFFITAS REQUESTED SEE SHEETA-1 Comment: 5) PLEASE PROVIDE SPACING OF FLOOR JOISTS, FLOOR SHEATHING MATERIAL, AND DESCRIBE HOW THE FLOOR SHEATHING IS ATTACHED TO THE FLOOR JOISTS. VERIFY JOIST SIZE ON PLANS, BOTH 2X8 AND 2X70 ARE CALLED OUT IN DIFFERENT LOCATIONS (2X8 @ VA2). ([A]107.2.1) RESPONSE: ADD SPACING FOR FLOOR JOISTS. AND DESCRIBED HOW FLOOR SHEATHING IS ATTACHED VERIFIED JOIST SIZE ON PLAN AS REQUESTED, CORRECTED JOIST CALL OUT. SEE PAGE A-1 & A-2, 212212021 Comment: 6) PROVIDE HEADER SIZE OVER LARGE WINDOW OPENING. RESPONSE: ADD 4.2X8 HEADER OVER LARGE WINDOWAS REQUESTED SEE SHEETA-3 212212021 Comment: 7) PROVIDE ROOF FRAMING DETAILS, PROVIDE DETAILS FOR THE CONNECTION TO EXISTING STRUCTURE. ([A]107.2.1) RESPONSE. ADD ROOF FRAMING DETAILS AND CONNECTION AS REQUESTED. 212212021 Comment: 8) PROVIDE LOCATION OF CONDENSER & RECEPTACLE AT CONDENSER. (IA]107.2.1) RESPONSE. ADD CONDENSER &RECEPTACLE LOCATION AS REQUESTED SEE SHEET A-3. 212212021 Comment: 9) PROVIDE ELECTRIC LOAD CALCULATIONS, VERIFY EXISTING SERVICE WILL ACCOMMODATE NEW([AJ1107.2.1) RESPONSE: ELECTRIC LOAD CALCULATIONS WILL BE SUBMITTED WITH RE -SUBMISSION, EXISTING SERVICE WILL BE VERIFIED TO ACCOMMODATE NEW ADDITION 212212021 Comment: 10) NO PLUMBING RISER PROVIDED.([A]107.2.1) RESPONSE: PLUMBING RISER LAYOUTIS NOW PROVIDED. 212212021Comment 11) ENERGY FORM .PLEASE USE THE CURRENT ENERGY FORM. RESPONSE. THE CURRENT ENERGY FORM WILL BE USED FOR THIS RE- SUBMIT. -EXTERIOR WALL IS NOT MASONRY PER PLANS. RESPONSE THE EXTERIOR WALL IS 2X8 FRAME. -HVAC IS SHOWN AS EXISTING. RESPONSE: HVAC SYSTEM WILL BE A NEW SYSTEM FOR THE NEW ADDITION. ZONING REVIEW INCOMPLETE Angela Vassar 211212021 2112QO21 Comment: PLEASE SUBMIT TWO CORRECTED SEALED SURVEYS SHOWING THE BREEZEWAY AND PROPOSED PLAYROOM, BATHROOM AND LAUNDRY ROOM. PLEASE ASK THE SURVEYOR TO SHOW THE SEPTIC AND DRAINFIELD, RESPONSE: TWO REVISE SEALED SURVEYS SHOWING THE BREEZEWAY & PROPOSED PLAYROOM, BATHROOM AND LAUNDRY ROOM WITH SEPTIC AND DRAINFIELD SHOWN WILL BE SUBMITTED. Digitallysi ned g N SIM44 �'' electronically cally signed and J o se hQ..• by Joseph ' ' ' j 5�. tceNSF' •tis'' sealed by Joe Simmons, on the date/time stamp Simmons, III P.E ��:` shown using a digital S fTlfTlon Date: _ No 52101 : - * ; * * = signature. Printed copies of this document are not S III P. C 2021.03.10 C ='fl '• r X •'• considered signed and sealed and the signature / 23:45:04-OS'OO� O STATE OF /V�� beln any electronic coust pies.