HomeMy WebLinkAboutreview commentsAPPENDIX RD — FORMS
Residential Building Thermal Envelope Approach
R-Value Computation Method
I FORM R402-2020 Florida Climate Zone 2 1
PROJECT NAME John Paul Edgar BUILDER:
ANDADDRESS: 5512 Pine Tree Dr. Ft. Peirce PERMITTING OFFICE:
JURISDICTION NUMBER:
OWNER: John Paul Edgar PERMIT NUMBER:
PERMIT TYPE: NUMBER OF UNITS:
WORST CASE? no CONDITIONED FLOOR AREA:
Scope: Compliance with Section R402.1.2 of the Florida Building Code, Energy Conservation, shall be demonstrated by the use of Form
R402 for single- and multiple -family residences of three stories or less in height, additions to existing residential buildings, alterations,
renovations and building systems in existing buildings, as applicable. To comply, a building must meet or exceed all of the energy efficiency
requirements and applicable mandatory requirements summarized on this form. If a building does not comply with this method, or by the UA
Alternative method, it may still comply under Section R405 or R406 of the Florida Building Code, Energy Conservation.
General Instructions:
1. Fill in all the applicable spaces of the "INSTALLED" row in the INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT table with the
information requested. All "INSTALLED" values must be equal to or more efficient than the required levels. "AVG" Indicates an area weighted
average is allowed; "LOWEST" indicates the lowest R-value to be installed must be entered.
2. Complete the tables for air infiltration and Installed equipment.
3. Read the MANDATORY REQUIREMENTS table and check each box to indicate your intent to comply with all applicable Items.
4. Read, sign and date the "Prepared By" certification statement at the bottom of this form. The owner or owner's agent must also sign and date the
form.
INSULATION AND FENESTRATION REQUIREMENTS BY C.n MPnNPNT1
REQUIREMENTS
FENESTRATION SKYLIGHT'
GLAZED
CEILING
WOOD
FRAME
MASS WALL
FLOOR
BASEMENT
SLAB'R-
CRAWL
U-FACTOR•''
U-FACTOR
FENESTRATION
SHGCt.'
R-VALUE
WALL R-
R- VALUEs6
R-VALUE
WALL R-
VALUE &
SPACE
WALL R.
VALUES
VALUE
DEPTH
VALUE
XIMATE ZONE 1
NH
0.75
0,25
30
13
314
13
0
0
0
XIMATE ZONE 2
0.40
0.65
0.25
38
13
4/6
13
0
0
0
VALUE
AVG
AVG
AVG
LOWEST
LOWEST
LOWEST
LOWEST
LOWEST
LOWEST
LOWEST
INSTALLED:
.40
.25
R_38
R-13
R-Value Calculation Method - [PASS /FAIL)
For Si. 1 foot = 304.8 mm; NR = No requirement.
(1) R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the
insulation, the installed R-value or the insulation shall not be less than the R-value specified in thetable.
(2) The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed
fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30.
(3) For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code, Residential or Section 1609.1.2 of the Florida Building Code,
Building, the maximum U-factor shall be 0.65 in Climate Zone 2. An area -weighted average of U-factor and SHGC shall be accepted to meet the requirements,
and up to 15 square feet of glazed fenestration area are exempted from the U-factor and SHGC requirement based on Section R402.3.1, R402.3.2 and
R402.3.3,
(4) One side -hinged opaque door assembly up to 24 square feet is exempted from this 0-factor requirement based on Section R402.3.4.
(5) R.values are for insulation material only as applied in accordance with manufacturers installation instructions.
(6) The second R-value applies when more than half the insulation is on the interior of the mass wall.
(7 R-5 shall be added to the required slab edge R-values for heated slabs. Insulation depth shall be the depth of the footing or 2 feet, whichever is less in Climate
Zones 1 through 3 for heated slabs.
Blower door test is required on the building envelope to verify leakage < 7 ACH50; test report must be provided to code official before
Air infiltration: CO is issued. Florida Building Code, Energy Conservation Section R402.4.1.2 testing exception may apply for additions, alterations,
orrenovations.
(continued)
Prepared By:
Ace Air Conditioning
Jimmy Evans
HVAC/Mechanical LiGemw
CAG1913033 6
Vk
FLORIDA BUILDING CODE — ENERGY CONSERVATION, 7th EDITION (2020) R-57
APPENDIX RD—FORMS
FORM R402--continued
EQUIPMENT REQUIREMENTS AND INSTALLED VALUES
Fill in the "INSTALLED EFFICIENCY LEVEL" column with the Information requested. For multiple Systems of the same type, indicate the minimum efficient
system. All "INSTALLED" values must be equal to or more efficient than the required level. If a listed "SYSTEM TYPE" is not to be Installed, write In "N/A"
for not applicable.
SYSTEM TYPE
MINIMUM EFFICIENCY LEVEL REQUIRED
INSTALLED EFFICIENCY LEVEL
Air distribution system'
Not allowed in attic
Location: Attic
Air handling unit
Duct R-value
Factory Sealed
= R-8 (Ducts in
Factory Sealed? ON
unconditioned attics, Diameter>- 3 in.)
= R-6 (Ducts in unconditioned non attics, Diam. > 3 in.)
R-Value (In unc. attic) = R- g
R-Value (In unc, non attics) _
= R-6 (Ducts in unconditioned attics, Diameter < 3 in.)
R-Value (Small ducts in attic) _
= R-4.2 (Ducts in unconditioned not attics, Diam. < 3 in.)
R-Value (Small ducts in one) _
All ducts are in conditioned space (No minimum)
All in conditioned space ? YAM
Air leakage'Duct test
Air handler installed: Total leakage = 4 cfm/100 ST.
Air handler not installed: Total leakage = 3 cfm/100 ST.
Total leakage = _ cfm/700 s.f.
Duct testing
Test not re
required if all ducts and AHU are within the building thermal envelope and
Air handler installed? YIN
for additions or alterations where ducts extended from existing heating and
Test report required7EIN
cooling system through unconditioned space are <40linear It.
Air conditioning systems:
Minimum federal standard required by NAECA':
Central system < 65,000 Btu/h
SEER 14.0
SEER (Mint- 14
PTAC
EER [from Table C403.2.3(3)]
EER (Min)=
Other:
See Tables C403.2.3(1)-H 1)
Type= Effie. (min)_
Heating systems:
Minimum federal standard required by.1.1:
<
Heat pump 65,000 Btu/h
HSPF> 8.2
HSPF (Min) = 8 2
Gas furnace, non weatherized
Oil furnace,
AFUE > 80 %
,
AFUE (Min)
non -weatherized
AFUE > 83%
AFUE (Min) _
Other:
Type = Eliic. (min) _
Water heating system (storage type):
Minimum federal standard required by NAECA2:
Capacity =
Electric''`
s
UEF 40 gal. 0.923; 50 gal.: 0,921: 60 gal.: 2.051
UEF (Min)= Existing
Gas (iretl°
UEF 40 gal. 0.580; 50 gal.: 0.563; 60 gal.: 0,766
UEF (Min) _
Other (descnbe)s r
Type = Effie. (min) _
Equipment Efficiency —[PASS / FAIL]
(1) Ducts & AHU installed 'substantial) leak free' per Section R403.3.2. Test required by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or
individuals licensed as set forth in Section 489.105(3)(U. (g), or (i), Florida Statutes. he total leakage test is not required for ducts and air handlers located entirely
within the building thermal envelope, and for additions where ducts from an existing healing and cooling system extended to the addition through unconditioned
space are less than 401inear ft.
(2) Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1987 for typical residential equipment and are subject to NAECA rules and
r gelations. For other types of equipment, see Tables C403 2.3 H.11) f the Commercial Provisions of the Florida Building Code, Energy Conservation.
(3) For electric storage volumes < 55 gallons, minimum UEF = 0.9349 - (0,0001 ' volume). For electric storage volumes > 55 gallons, minimum UEF = 2.2418 - (0.0011
volume).
(4) For natural gas storage volumes <55 gallons, minimum UEF = 0.692 - (0.0013' volume). For natural gas storage volumes > 55 gallons, minimum UEF - 0.8072-
(0.0003 ' volume).
(5) For electric reckless, min. UEF = 0,92, For natural gas tankiess, min, UEF = 0,81.
(6) Referenced UEFs shown are for medium draw pattern value provided by manufacturer.
(continued)
R-58 FLORIDA BUILDING CODE— ENERGY CONSERVATION, 7th EDITION (2020)
APPENDIX RD — FORMS
FORM R402
MANDATORY REQUIREMENTS
Component
Section
Summary of Requirements
Check
To be caulked, gasketetl, weatherstripped orotherwise sealad per
Table R402.4.1.1. Recessed lighting IC -rated as having < 2.0 c(m
Air leakage
R402 4
tested to ASTM E283.
Windows and doors: 0.3 clm/sq.ft (swinging doors: 0.5 cfm/sf) when
tested to NFRC 400 or AAMAANDMA/CSA 101/I.S. 2/A440.
Fireplaces: Tight -fitting flue dampers & outdoor combustion air
Programmable thermostat
R403 1 2
A programmable thermostat is required for the primary heating or
cooling system.
Ducts shall be tested as per, Section R403.3.2 by either individuals
Air distribution system
R403.3.2
as defined in Section 553.993(5) or (7), Florida Statutes, or
R403.3.4
individuals licensed as set forth in Section 489.105(3) (f), (g) or (i),
Florida Statutes. Air handling units are not allowed in attics.
Comply with efficiencies in Table C404.2. Hot water pipes insulated
Water heaters
R403.5
to>_ R-3 to kitchen outlets, other cases. Circulating systems to have
an automatic or accessible manual OFF switch. Heal trap required
for vertical pipe risers.
Cooling/heating equipment
R403.7
Sizing calculation performed & attached. Special occasion cooling
or heating capacity requires separate system or variable capacity
system.
Spas and heated pools must have vapor -retardant covers or a
Swimmin g pools & spas
R403.10
liquid cover or other means proven to reduce heat loss except if
70 0 of heat from site -recovered energy. Off/timer switch required.
Gas heaters minimum thermal efficiency is 82 0. Heat pump pool
heaters minimum COP is 4.0.
Lighting equipment
R404.1
Not less than 90 % of the lamps in permanently installed luminaires
shall have an efficacy of at least 45 lumens -per -watt or shall utilize
lamps with an efficacy of not less than 65 lumens -per -watt.
I hereby certify that the plans and specifications covered by this form are
Review of plans and specifications covered by this form Indicate
in compliance with the Florida Building Code, Energy Conservation.
compliance with the Florida Building Code, Energy Conservation. Before
PREPARED BY:_JImmy Evan- _ Date 3 - 3 0 - 21
construction is complete, this building will be inspected for compliance In
I hereby certify that this building is in compliance with the Florida Building
accordance with Section 553.908, F.S.
Code, Energy Conservation.
CODE OFFICIAL:
OWNER/AGENT: Date:_
__
Data:
ADA Accessibility Disclosure Statement - This document may be reproduced upon request in an
alternative format by contacting the County ADA Coordinator (772) 320-3131, the County
Administration Office (772) 288-5400, Florida Relay 711, or by completing our accessibility feedback
form at www,martin.fl.us/accessibility-feedback.
FLORIDA BUILDING CODE — ENERGY CONSERVATION, 7th EDITION (2020) R•59
... ___.. _............. .