HomeMy WebLinkAboutP0.1WALL
KARP
ZURN Z-1022 ACCESS
AUTOMATIC DOOR
PRIMER
FLOW FROM CHROME
POTABLE ESCUTCHEON
PLATE
WATER
RISER ����IIII FLOW TO
� -a
FIXTURE
WALL
FLOOR DRAIN
AIR GAP VACUUM J.R. SMITH
BREAKER POINTS 2005-AP
k F
12" MINIMUM 4
TO HORIZONTAL ° e
RUN IN PIPE , ,
a<
TRAP PRIMER 4„
CONNECTION
TRAP PRIMER DETAIL
NOT TO SCALE
V
t
\NE. P� 04
Ar
G\"l\\_ 0
P F°Rs �v!� °NPR
eeEp F * t' cc
S�v ppM ES � , \N•
SPEC'(\pcP,\\ON PFt\pR
ID
Pp\N
SANITARY
SANITARY ISOMETRIC
N.T.S.
PLUMBING NOTES
1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE
INSTALLATION OF A COMPLETE SCOPE OF WORK. ALL WORKMANSHIP AND MATERIALS SHALL BE IN
STRICT ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION (2020) - PLUMBING,
APPLICABLE LOCAL CODES, RULES, AND ORDINANCES.
2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL
EXISTING CONDITIONS.
3. ALL MATERIALS SHALL BE NEW AND OF GOOD QUALITY.
4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS
WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY -OPERATIONAL. ALL EXCAVATION
AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS
CONTRACT.
5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION
AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK.
6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTS.
PLUMBING CONTRACTOR SHALL OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING
WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS
OF HIS WORK BY REGULATORY AUTHORITIES.
7. CONTRACTOR SHALL SUBMIT TO ARCHITECT/ENGINEER, FOR REVIEW & APPROVAL, FIVE (5) SETS OF
MANUFACTURER'S CUT SHEETS FOR EACH FIXTURE, PIPING/FITTING MATERIAL AND EQUIPMENT ITEM
WITH ASSOCIATED CONTROLS, THAT ARE INCLUDED IN THE CONTRACT.
8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING,
EQUIPMENT, ETC.
9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE
PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ARCHITECT/ENGINEER PRIOR TO
BEGINNING CONSTRUCTION.
10. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERT ELEVATIONS OF ALL EXISTING UTILITIES
PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ARCHITECT/ENGINEER OF ANY DISCREPANCIES.
11. WATER DISTRIBUTION PIPING ABOVE AND BELOW GROUND SHALL BE TYPE "L" COPPER. ALTERNATE
PIPING & FITTING MATERIALS MAY BE USED IN ACCORDANCE WITH FLORIDA BUILDING CODE 7TH
EDITION (2020) - PLUMBING, TABLES 605.3, 605.4 & 605.5, WHEN APPROVED BY ENGINEER OF
RECORD AND LOCAL AUTHORITY HAVING JURISDICTION. PROVIDE ALTERNATE FOR CPVC PIPING &
FITTINGS EQUAL TO LUBRIZOL CORZAN OR FLOW -GUARD GOLD. PROVIDE ALTERNATE FOR PEX TYPE
'A' PIPING & FITTINGS EQUAL TO UPONOR. ALTERNATES ARE PERTINENT FOR WATER SERVICES
KNOWN OR DETERMINED TO HAVE ACIDIC CHARACTERISTICS OR OTHER PARTICULAR CIRCUMSTANCES
AS DEEMED APPROPRIATE BY DIRECTIVE FROM THE OWNER. CONTRACTOR SHALL PERFORM A WATER
TEST TO DETERMINE WATER CHEMISTRY PRIOR TO ANY WORK OR PIPING INSTALLATION AND SHALL
SUBMIT TEST RESULTS TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. DISINFECTION OF
POTABLE WATER SYSTEM SHALL COMPLY WITH FLORIDA BUILDING CODE 7TH EDITION (2020) -
PLUMBING, SECTION 610. ALL WATER PIPING & FITTINGS SHALL BE OF DOMESTIC MANUFACTURE;
SPECIFICALLY IN THE UNITED STATES OF AMERICA.
12. SOIL, WASTE, VENT, AND RAINWATER (DWV) PIPING & FITTINGS SHALL BE CAST IRON OR PVC, WHERE
CODE ALLOWS. PVC MAY NOT BE USED THRU RATED ASSEMBLIES OR IN PLENUMS. PVC PIPING
SHALL BE SOLID -CORE ONLY; FOAM -CORE PIPING SHALL NOT BE ACCEPTED. CAST IRON PIPING &
FITTINGS SHALL BEAR THE CISPI-301 MARK. ALL DWV PIPING & FITTINGS SHALL BE OF DOMESTIC
MANUFACTURE; SPECIFICALLY IN THE UNITED STATES OF AMERICA.
13. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE ANGLE STOPS AND APPROPRIATELY
MARKED ACCESS PANELS (WHERE REQUIRED). COORDINATE LOCATIONS WITH GENERAL CONTRACTOR
PRIOR TO INSTALLATION.
14. PROVIDE APPROVED WATER HAMMER ARRESTORS FOR ALL (GROUP) PLUMBING FIXTURES, SIZED &
LOCATED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS & PDI-WH2O1.
15. PROVIDE DIELECTRIC COUPLINGS OR FLANGES BETWEEN ALL DISSIMILAR METALS IN PIPING AND
EQUIPMENT CONNECTIONS.
16. ISOLATE COPPER PIPING FROM METALLIC HANGERS OR SUPPORTS WITH ISOLATOR PADS OR
NON-CONDUCTIVE MATERIAL.
17. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE,
SMOKE AND WATER PENETRATION BY FILLING ANNULAR SPACE BETWEEN PIPING AND SLEEVES WITH
INTUMESCENT CAULK, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS, AS PART OF THE
PLUMBING CONTRACTOR'S WORK.
18. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS
FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BY OWNER.
CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL
INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE
BEEN DAMAGED.
19. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS SHALL
MAINTAIN THE SAME RATING AND SHALL MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED.
20. PROVIDE COMBINATION CLEANOUT PLUG AND COVER PLATE OR ACCESS PANEL FOR ALL WALL
CLEANOUTS. FINISH TO MATCH NEARBY FIXTURE TRIM.
21. NO COMBUSTIBLE MATERIAL SHALL BE INSTALLED IN MECHANICAL ROOMS NOR IN CEILING SPACES
WHERE USED AS RETURN AIR PLENUMS.
22. NO WATER, SANITARY OR DRAINAGE PIPING SHALL BE INSTALLED IN ELECTRICAL OR ELEVATOR
EQUIPMENT ROOMS.
23. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCIBLE DIAGRAM LOCATING ALL
VALVES SHALL BE FURNISHED FOR OWNER/OPERATOR.
24. CONDENSATE DRAIN PIPING SHALL BE TYPE "L" COPPER WITH ARMAFLEX INSULATION AND A
VAPOR -BARRIER JACKET PER FLORIDA BUILDING CODE 7TH EDITION (2020) - ENERGY
CONSERVATION, TABLE C403.2.8. PVC WITHOUT INSULATION IS ACCEPTABLE FOR RISERS AND BELOW
GRADE PIPING. WHEN USED IN A RETURN AIR PLENUM, PVC PIPING WITH INSULATION IS ACCEPTABLE
IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. CONDENSATE PIPING SHALL NOT DRAIN ONTO THE
ROOFING SYSTEM NOR ANY OF ITS COMPONENTS. CONDENSATE PIPING ARRANGEMENT IS EXEMPT
FROM MINIMUM EQUIPMENT CLEARANCE REQUIREMENTS PER FLORIDA BUILDING CODE 7TH EDITION
(2020), SECTION 1522.3.5. ALL HORIZONTAL RAINWATER PIPING RUN ABOVE FINISHED FLOOR THAT
RECEIVES CONDENSATE DISCHARGE SHALL BE INSULATED WITH ARMAFLEX AND A VAPOR -BARRIER
JACKET.
25. HOT WATER PIPING INSULATION SHALL BE PROVIDED IN ACCORDANCE WITH FLORIDA BUILDING CODE
7TH EDITION (2020) - PLUMBING, TABLE 607.5 & FLORIDA BUILDING CODE 7TH EDITION (2020) -
ENERGY CONSERVATION, TABLE C403.2.8. CONTRACTOR SHALL USE ARMAFLEX OR EQUAL WHERE
APPLICABLE. WHERE DOMESTIC WATER TEMPERATURES CAN CAUSE SWEATING, ALL COLD WATER
PIPING SHALL BE INSULATED WITH ARMAFLEX INSULATION AND A VAPOR -BARRIER JACKET, PER
FLORIDA BUILDING CODE 7TH EDITION (2020) - ENERGY CONSERVATION, TABLE C403.2.8.
26. AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE
ACCEPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. INSTALLATION METHODS SHALL BE IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS.
27. PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL
SHUT-OFF.
28. STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO
VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL
CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS.
29. ALL HORIZONTAL RAINWATER PIPING THE RECEIVES CONDENSATE DISCHARGE FROM AIR
CONDITIONING EQUIPMENT SHALL BE INSULATED WITH 1" THK. ARMAFLEX.
30. PLUMBING PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION
WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, FIRE SPRINKLER, STRUCTURAL AND CIVIL PLANS AND
SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. PIPING MODIFICATIONS SUCH AS OFFSETS, BENDS,
TRANSITIONS, AND SIZES SHALL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL
SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
CHANGES IN PIPE SIZES AND ROUTING SHALL BE REQUIRED BY THE CONTRACTOR TO AVOID CONFLICTS
AND TO ADAPT TO EXISTING FIELD CONDITIONS PROVIDED THAT INSTALLATION MEETS ALL
APPLICABLE CODES.
31. SUPPLY TRAP PRIMER FOR ALL FLOOR DRAINS, FLOOR SINKS, HUB DRAINS, ETC. SHOWN ON PLANS.
32. CONTRACTOR TO FIELD VERIFY ALL SUPPLY PRESSURE REQUIREMENTS AND LIMITATIONS. PROVIDE
PRESSURE REDUCING VALVE IF REQUIRED.
PLUMBING SHEET INDEX
DESCRIPTION
FP3.1
PLUMBING NOTES, LEGENDS, AND DETAILS
DOMESTIC WATER PLAN
DOMESTIC WATER PLAN
PLUMBING LEGEND
CO
CLEAN OUT
SANITARY SEWER PIPING
S.O.V.
SHUT-OFF VALVE
- - -
VENT PIPING
COTC
CLEAN OUT TO GRADE
-
DOMESTIC COLD WATER PIPING
FS
FLOOR SINK
- -
HOT WATER PIPING (110')
CW
DOMESTIC COLD WATER
- - -
HOT WATER PIPING (140')
HW
DOMESTIC HOT WATER
- - -
HOT WATER RECIRCULATING PIPING
HWR
DOMESTIC HOT WATER RECIRCULATING
CD ---
CONDENSATE PIPING
HB
HOSE BIBB
CA
COMPRESSED AIR PIPING
VTR
VENT THRU ROOF
T&P
TEMPERATURE AND PRESSURE RELIEF
GATE VALVE
SD ----
STORM DRAIN PIPING
GLOBE VALVE
G ----
GAS PIPING
N
CHECK VALVE
S--o-s
PIPE RISE UP
GAS SOLENOID VALVE
PIPE DOWN OR DROP
i
GAS COCK
E
CAPPED END OF PIPE
4#
WATER HAMMER ARRESTER (PDI No.)
POINT OF CONNECTION
® FD
FLOOR DRAIN
P-TRAP
PROVIDE TEST TEE
WITH SCREWED COUNTER-
SUNK ABS PLASTIC PLUG:
TAPERED -THREAD WITH
TFE JOINT COMPOUND. -
WHERE CLEANOUT TEE
IS CONCEALED IN A
CHASE OR PARTITION,
PROVIDE A ROUND 18
GAUGE STAINLESS STEEL
COVER WITH BEVELED
EDGES AND FLATHEAD
MACHINE SCREW.
CONCRETE
FLOOR
SLAB
�r
COLUMN OR PARTITION
I AS SHOWN ON FLOOR PLAN
CLEANOUT FACE SHALL
i - j BE WITHIN 4" OF WALL
SURFACE. PROVIDE
PIPE EXTENSION IF REQUIRED.
I I
I I
I I
I I
I I
I
I �
I I
a I I a a a
< d
NOTE:
PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES
NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM
WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS.
WALL CLEANOUT DETAIL
NOT TO SCALE
SHOCK ARRESTOR SCHEDULE
P.D.I. DESIGNATION
MANUF. & MODEL
FIXTURE UNITS
CONNECTION
A
SIOUX CHIEF 652-A
1-11
1/2"
B
SIOUX CHIEF 653-B
12-32
3/4"
C
SIOUX CHIEF 654-C
33-60
1"
SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO
ACCESS DOOR REQUIRED. CONFORMS TO ANSI/ASSE 1010 STANDARDS.
SLOPE OF HORIZ. DRAINAGE PIPE
SIZE (inches)
MINIMUM SLOPE (inch per foot)
2-1/2 or less
1 /4
3 to 6
1 /8
8 or larger
1 /16
TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2020
Bradly L
Brown P.E
o QQ�
O
U
U)
Z
O
CU
O
LL_
O
z
LU
U)
W
W
LU
LU
LU
LU
U
I
O
O
CV
CO
Digitally signed by Bradly L
Brown P.E.
DN: cn=Bradly L Brown P.E.,
o=Kamm Consulting Inc.,
ou=FL# 58232,
email=jmayr@kammconsulting
• .com, c=US
Date: 2021.03.15 11:39:32
-04'00'
ISSUED FOR PERMIT ONLY 03-15-21
NOT FOR PRICING OR CONSTRUCITON
KAMM CONSULTING PROJECT #:
2020-0562
PROJECT MANAGER: JOHN MAYR
tort Orange Avenue
ff
f�AFort
M M
Pierce, Florida 34950
Phone 954.448.0792
j mayr@kammconsulting.com
Onsu �
Certification of Authorization #8189
PRINCIPAL
03-15-21
Bradly L Brown Florida License
#58232 date
CTS
0
.Q
U
0
c
0
U
E
U O
0 0
O m Co
M to
(Y J O
Q LL
lYl � N
Z
Q
O � x
Z LL
O m
O
� o
U N
Q O Cy
N
LLi
LU Cn ~
m N H
J
L LL
C m
� L
� 0
O
CN
co LL
m
m
U
J
W
to
It
signed