HomeMy WebLinkAboutAPPROVED JAT 5V ver 2020Business ► Professional ♦ i
BCIS Home Log In user Registration : Hot Topics submit Surcharge Sta[s &l=acts
Product Appro►raI
dbar4
USER: Public User
PSdUCt PPTUal Menu a P [ or c Gore S r
FL #
Application Type
Code Version
Application Status
Comments
Archived
rh > AP_pli£$tinn List a Application Detall
FL17443-R2
Revision
2020
Approved
Product Manufacturer ] A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE, FL 34982
(772)466-4040
kylewhite228@aal.com
Authorized Signature Kyle Taylor
kylewhite228@aol.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Publlcatlons i contact us ' BCIS Slte Map Links search
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date
01/23/2023
Validated By
Diane Marotta, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections From the Code
17443 R2 C I FL17443 R2 I C Code Eval Re tl
Details-sss.pdf
Standard
Year
TAS 125
2003
UL 1897
2012
U1-580
2006
Product Approval Method Method 1 Optlon D
0
Date Submitted
12/03/2020
Date Validated
12/13/2020
Date Pending FBC Approval
01/06/2021
Date Approved
02/09/2021
summary of Products
FL *
17443.1
Model, Number or Name
5 V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ; Yes
Impact Resistant: N/A
Design Pressure: +N/A/-129.25
Other.-129.25 @ 6" o.c. -69,25 #16" o.c. margin of safety
2:1 with 24" max. coverage Install per manufacturers detail.
Not for use in HVHZ.
17443.2 VICTORIAN CRIMP SHINGLE
Limits of Use
Approved for use In HVHZ: No
Approved For use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-105
Other:-105PSF margin of safety 2:1. Install per
manufacturer's details and in compliance with CURRENT FBC
not for use in HVHZ.
Description
26GA 1/2" rib height over 15/32" ARA plywood
Installation Instructions
FL17443 RZ II F 17443 ,R2 J A Taylor FBC Cpde Eval R p=
with DetaiIs..sss.pdf
Verifled By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 R2 AE F 43 R Tayiar FgC Code Eval
I &port with Details,-sss.pd
Created by Independent Third Party: Yes
26GA 1/2" RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER
CDx/APA 15/32" PLYWOOD
Installation Instructions
FL17443 R2 II FL17443 R2 ] A Taylor FB _Code Eval Rem
ygith i3etalls_sss.p ff
Verlfled By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 RZ AE FL17443 R2 J A]ayi�i r-FBC Come Eval
Report with Details-sss. Wg
Created by Independent Third Party: Yes
Contact Lis :: 2601 Blair Stone Raad, Tallahassee FL 32399 Phone: 850.487-1824
The State of Florida Is an AAJEE0 employer. Copyright 2007-2013 State of Florida.:: Pn�a_c Statement :: Accessibility Statement :: Refund 5tatement
Under Florida law, email addresses are public records. If you do not want your S-mall address released in response to a public -records request, do not send electronic
malt to this entity. Instead, contact the offlce by phone o- by tradIllonal mail, If you have any questlons, please contact 850.487.1395, •Pursuant to Sectlen 455,275[l�,
Florida Statutes, effective October 1, 2012, ilcensees 11censed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emaiis
provided may be used for offclaI communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a IIce nsee under Chapter 455, F.S., please dick here .
Produet Approval Accepts.
IT U F-Aiiii'l -"Mace
Credit Card
safe
J A TAYLOR 302 Milton Dr.
Drive Fart Pierce, FL 34962
Florida Product Approval #17443 Method: 1-D (772) 466-4040
Compliant with CURRENT Florida Building Code
Compliant with Florida Product Approval Rule # 6IG20-3
Compliant Quality Assurance Program: PRI CONSTRUCTION MATERIALS TECHNOLOGY
5V Crimp thru fastened W rib at each panel edge and 1 fastener in the center of the panel, 24" net coverage, 26GA ASTM
A792, G-50, A255, .018, 50ksi min. over ruin. 15/32" thick CDX plywood deck. Corrosion Resistant fastener #9-15 HWH with
sealing washers, metal to wood connections with fastener length to penetrate 5/16" thru substrate. Fasten along the crown
of the rib in the center of panel and along the lap. First fastener to be within 3" of panel edges. Min. 8Dx2" annular ring shank
nails spaced 6" O.C. re -roofing, with less than 19/32" plywood (min.15/32"), this attachment is to be used in addition to
existing attachment. Deck slope 2:12 or greater and shall be compliant with FCurrent FBC Under-layment: See FBC Sec. 1507
"Design Pressure: Spacing:
-69.25 PSF 16" O.C.
-129.25 PSF
26GA ASTM A792, G-50, AZ55, .018, 50ksi Victorian Crimp Shingle over 15/32" CDX/APA Plywood attached to roof trusses.
Corrosion Resistant Fastener #10 x 1" Zinc plated, MTW Pancake Head, installed at 2 per panel into lock seam. Panels applied
with 12" exposure, adjacent shingles inserted into lock seam of previous shingle. Deck slope 2112 or greater and shall be
compliant with CURRENT Under-layment: See CURRENT FBC Under-layment Sec. 1507 Table
"Design Pressure:
-105 PSF
"DESIGN PRESSURE INCtUD 5-,*S tFEry MARGIN OF 2.1
TEST REPORTS Reference Data;
Hurricane Test Laboratory (TST-1527)
PRI Construction Materials Technologies (TST-5878) #0224-0501-06 TAS 125 (UL 580-942)
#FAE-023-02-01 UL 580-06/UL 1897-04z
1. UL 580-94 test stondords are equivalent to UL 580-06 test standards.
2. UL 1897-04 test standards are equivalent to UL 1897-12 test standards.
Under-layment to be compliance with Current Florida Building Code (F8C). see Charts Minimum slope to be compliant
CURRENT Florida Building Code and per with Manufacturer's installation reference.
2. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
3. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
4. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
S. Support framing in compliance w/CURRENT FLORMA BUiLDiNG CODE Chapter 22 Steel, Chapter 23 Wood and Chapter 16
Structural loading.
6. This report does not imply warranty, installation, recommended product use outside of this report.
Certificate of Independence: Locke Bowden, P.E. does not have, nor will acquire a Financial Interest in any
company manuEacturing or distributing products under this evaluation.
Locke owden, RE. is net owned, operated, or controlled by any company, , �t��l�t s rrrirt r
manufacturer or distributing products under report.
o.49704
a a (� w
•• �1 • �t1i00
i� /a N Fib'►`�•
f4fflitfi111
5 V Crimp
Fastener- #9-15 corrosion resistant wlsealing washers
24" coverage
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with Current Florida Building Code, Section 1507
Perimeter fastening: 6"o.c.
Main Field fastening12"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel
MINIMUM 2 FASTENERS
AT LOCK SEAM
d CUT 112 SHINGLE
:REATE STAGGERED
rERN
-ORIAN CRIMP
JGLES
VICTORIAN CRIMP SHINGLF---
LU
LOCK SEAM
p
�
CL
w
Fastener.•# 10 x I"
Zinc Plated MTW
Pancake Head
9"EXPOSURE