Ij FL# FL389-R10
t Application type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association,Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach,FL 33407
(561)209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@eastemmetat.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A..Tillit,Jr. P.E.
Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2021
Validated By John Henry Kampmann Jr.
Validation Checklist-Hardcopy Received
Certificate of Independence F1.389 R10 COI COI ASSA SLADE-1 .pdf
FL389 R10 COT COT ASSA FLAOEI.2.pdf
FL389 R10 Ctal CDI AS5A_5LAD[3.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM E-1886 2012
ASTM E-1996 2012
ASTM E-330 2002
TAS 202,202,203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
www.floridabuilding.org/pripr app d.aspx?param=wGEVXQwtDgvYYHH2vJvx53MwaXdCOtOXPGxaL8B7Zzg%3d 113
i
1/6/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 10/15/2020
Date Validated 11/06/2020
Date Pending FBC Approval 11/06/2020
Date Approved 12/15/2020
Summary of Products
FL# ,Model,Number or Name y` Description
389.1 Bertha.HV Accordion Shutter-Blade Extruded aluminum interlocking blades retained by tracks(top
3-(Non-HVHZ)-Drwg 20-165 and bottom)for storm protection
Limits of use Installation Instructions
Approved for use in HVHZ:No F 89 i110 II DRWING ASSS_A BLADE3.pdf
Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida,Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Large Missile Level"D".Max span Is 12'-3"for 40 psf FL389L Rio gE PEIZ ASSA BLADE3.pdf
positive ASD load and 13'-0"for 35 psf negative ASD load the Created by Independent Third Party:Yes
HV3 blade w/o window blade,5'-2"for 110 psf ASP load for
HV3 blade w/o window blade and 8'-11"for 62 psf,W-11"for
5S psf HV3 blade w/window blade working in unison.Max.span
for HV3 blade w/o window blade for installations Into Metal
Stud walls is 79"for max.ASD pressure rating of+72,-72 and
84"for+64,-64 psf.See sheet 5 for other spans and ASD
pressures.
389.2 Bertha HV Accordion Shutter-Blade 1 Extruded aluminum Interlocking blades retaine y tracks(top
Only-(Non-HVHZ)-Drwg 20-164 and bottom)for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL389 R-10 I1 ORWING ASSA BLADEI.pAfff
Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida,Inc. `
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Large missile level"D".Max.Span is 16'-0"for 30 p.s.f FL384 R10 AF PER ASSA BLADE1 p-d
negative ASD load depending on centermates and locking rod Created by Independent Third Party:Yes
configuration for the HVi blade,8'-0"for+64,-72 p.s.f.A.S.D.
load for HV blade for Keystone mountings 7'-0"p.s.f.for metals
stud mountings and 8'-0"for 110 p.s.f.for HV1A working In
unison.See sheets 7,11 and 20 respectively of installation
drawings for other spans and pressures.
389.3 Bertha HV Accordion Shutter- Extruded aluminum Interlocking 61a ed s rera n1 ed-by fraEks(top
COMBO-(Non-HVHZ)-Drwg 20-163 and bottom)for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ:No rL389 R10 1I OFtw_ASSA at_ADE1 2.pl
Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida,Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Large missile.Max.16'-0"span at 30 p.s.f ASD load FI W. R10 AG_PER ASSA_BLADE1 2.pdf
for Blade 1 and 18'-0"for Blade 2.See schedules on sheet 12, Created by Independent Third Party:Yes
25 and 28 respectively
I SD NL`Kt
contact Us::2601 Blair Stone Road,TBlla�assen FL 32399 Phone:850-487-IR24
The State of Florida Is an AA/EEO employer,Copyright 2007-20I3 State of Fin rlda.::Privacy Statement::AEassiblilty Statement:a Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mad.If you have any questions,please contact 850.487.1395.*Pursuant to Section 45S.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under chapter 4SS,F.S.must provide the Department with an email address if they have one.The emails
provided may be used tar official communication with the licensee.However email addresses are public record,If you do not wish to supply a personal address,please
provide the Department with an omoll address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click here.
Product Approval Accepts:
tv!' a i ® iral
Credii Card
Safe
www.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgvYYHH2vJvx53MwsXdCO10XPGxaL8B7Zzga/a3d 213