HomeMy WebLinkAboutAPPROVED DESIGN PRESSURE CALULATIONSDATE: 3/26/21 Order No.: 21RO219 CLIENT: Atlas Roofing ADDRESS: 851 South Deerfield Avenue; Deerfield Beach, FL 33441 PROTECT: 8000 South U.S. Hwv 1 Flat Concrete Deck ADDRESS: 8000 South U.S. Hwy 1: Port St Lucie, FL 34952 ASCE 7-16 DESIGN PRESSURE CALCULATIONS In Accordance with Chapter 30, Part I Proiect Information: Height = 40' Length = 80' Width = 75' Parapet Wall: < 3' Design Calculations: Velocity Pressure: Flat Concrete Deck Exposure: C Category: II Slope: < 7° Phone: 954-784-2941 E*-Fax: 954-784-7875 admin@fed-eng.com www.fed-eng.com Ultimate Windspeed: Vwt= 170 mph Basic Windspeed: V.d = 132 mph KZ = 1.04 Kd = 0.85 q = 0.00256*[(1.04)(0.85)(1.00)(1.00)(132)2] 39.4 psf Width of Pressure Coefficient Zone 1 and 2 0.6(40') — 24.0' Length of Pressure Coefficient Zone 3 0.6(40') = 24.0' Width of Pressure Coefficient Zone 3 0.2(40') = 8.0' Effective Wind Tributary Area: <10f 2 For parapet height three feet (T) or larger, zone three (3) can be treated as zone two (2) (ASCE 7-16). External Pressure Coefficient: 11) GCP F = -0.9 1) GCP1 = -1.7 2) GCP3 = -2.3 3) GCP3 — -3.2 Desien Pressures: Internal Pressure Coefficient: 1) GCPi — 0.18 Zone 1' P1' = 39.4*(-0.9 - 0.18) = -42.6 psf Zone 1 P1 = 39.4*(-1.7 - 0.18) = -74.1 psf Zone 2 P2 = 39.4*(-2.3 - 0.18) = -97.8 psf Zone 3 P3 = 39.4*(-3.2 - 0.18) = -133.3 psf ac MIAM aMADE F�OT �a'I'f51'i38 A[rxtC:n>s . -' Page 2 3126/21 8000 South US 1 Port St. Lucie, FL Attachment_ Requirements: Based on RAS-117 and N.O.A. #20-0723.27; with a design pressure of -635 psf; the referenced system is approved with base sheet adhered to the primed concrete deck with approved mopping asphalt applied withing the EVT range and at a rate of 20-40 lbs./sq. Ply sheet adhered to base sheet with approved mopping asphalt applied withing the EVT range and at a rate of 20-401bs./sq. Membrane adhered to ply sheet with approved mopping asphalt applied withing the EVT range and at a rate of 20-401bs./sq. Notes: All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and the Florida Building Code 2020 edition. Wind load calculations based on ASCE 7-16 and information provided by client. All work shall be inspected by our field engineer or city inspector to verify compliance with specifications. Digitally signed by Keith LeBlanc, P.E. *r,,,,,,,a• DN: c=US, st=Florida,l=Oakland ,`" �p4iN tFe ••,, Park, o=Federal Engineering & ���GENgF.{yy`i Testing, Inc., ou=FL Professional No.69394 *; '•,* Engineer #59394, cn=Keith * LeBlanc, P.E., email=keith@fed- ` STATE OF , r�,�d• eng.com Date: 2021.03.26 09:32:02 -04, 00 a c i MtAFIFiJV>C1E F D O� NM9HTU R18hcaxf3ae �- -�