Loading...
HomeMy WebLinkAboutAPPROVED NOA-Modified over cementMIAMF DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) CertainTeed LLC. 20 Moores Road Malvern, PA 19355 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.gov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roof System over Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 19-1028.11 and consists of pages 1 through 87. The submitted documentation was reviewed by Alex Tigera. NOA No.: 20-0723.27 CMSTe Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 1 of 87 ROOFING SYSTEM APPROVAL Cate2ory: Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Concrete Maximum Design Pressure: -635 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Descri tion All Weather/Empire Base 39 3/R" x 65' 10"; ASTM D 4601, Asphalt coated, fiberglass reinforced Sheet Roll weight: 70 lbs. Type H base sheet. (2 squares) Flexiglas Base Sheet 39 3/s" x 98'9"; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass weight: 901bs. II base sheet. (3 squares) Flintlastic Base 20 39 3/3" x 49' 6' ; Roll ASTM D 6163, Modified Bitumen coated fiberglass weight: 90 lbs. Grade S, Type I base sheet. (1.5 squares) Flintglas Ply 4 39 3/8" x 1647'; Roll ASTM D 2178, Fiberglass, asphalt impregnated ply weight: 38 lbs. Type IV sheet. (5 squares) UL Type G1 Flintglas Premium Ply 6 39 3/8" x 1647'; Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply weight: 40 lbs. VI sheet. (5 squares) UL Type G1 Flintlastic STA 39 3/8" x 32' 10"; ASTM D 6222, Smooth surfaced APP Modified Roll weight: 87 lbs. Grade S, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA 39 3/8" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA-FR 39 3/R" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GMS 39 3/8" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 94 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. NOA No.: 20-0723.27 MWMkgI M COUNTYExpiration Date: 05/19/23 Approval Date: 09/17/20 Page 2 of 87 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Test Dimensions Specification Product Description Flintlastic FR-P 39 3/8" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Flintlastic Premium FR-P 39 3/s" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type II Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Flintlastic FR Dual Cap 39 3/8" x 32' 10"; Roll ASTM D 6162, Granule surfaced SBS modified weight: 103 lbs. Grade G, Type II bitumen membrane with a nonwoven (1 square) polyester/fiberglass composite mat reinforcement for use in cold or mop applications. Flintlastic Cap 30 39 3/8" x 32' 10"; Roll ASTM D 6163, Granule surfaced SBS Modified weight: 86 lbs. Grade G, Type I Bitumen membrane with fiberglass mat (1 square) reinforcement for mop applications. Flintlastic FR Cap 30 39 3/3" x 32' 10"; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 861bs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Flintlastic FR Cap 30 T Flintlastic Base 20 T 39 3/g" x 32' 10' ; Roll weight: 100 lbs. (1 square) 39 3/s" x 33'; Roll Weight: 81 lbs. (1 square) ASTM D 6163, Granule surfaced SBS Modified Grade G, Type I Bitumen membrane with fiberglass mat reinforcement for torch application. ASTM D 6163, Modified Bitumen, coated fiberglass Grade S, Type I base sheet for torch application. Flintlastic Ultra Poly SMS 39 3/8" x 32' 10"; Roll ASTM D 6164, Smooth surfaced SBS Modified Base Sheet weight: 901bs. Grade S, Type I Bitumen Membrane with non -woven (1 square) polyester mat reinforcement, for mop or torched applications. Glasbase Base Sheet 36" x 98'9"; Roll ASTM D 4601, Asphalt coated, fiberglass base sheet. weight: 75 lbs. Type II (3 squares) Flintlastic Poly SMS Base 39 3/g" x 64' 3"; Roll ASTM D 4601, Modified Bitumen coated polyester Sheet weight: 90 lbs. Grade S, Type II base sheet. (2 squares) Yosemite Venting Base Sheet 39 3/s" x 32' 10' ; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced weight: 85 lbs. ASTM D 4897, buffer sheet. (1 square) Type II UL G3 NOA No.: 20-0723.27 Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 3 of 87 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Flintlastic APP Base T 39 3/8" x 65' 4"; Roll weight: 1001bs. (2 squares) Flintlastic Ultra Glass SA 39 3/8" x 33'11"; Roll weight: 73 lbs. (1 square) Black DiamondTM Base Sheet 36" x 687'; Roll weight: 78 lbs. (2 squares) Flintlastic SA P1yBase 39 3/8" x 64' 6"; Roll weight: 86 lbs. (2 squares) F1intBond Brush 5 gallon pails APPROVED INSULATIONS: Product Name F1intBoard ISO F1intBoard ISO Cold F1intBoardH ISO F1intBoardH ISO Cold ACFoam-II ACFoam-III ACFoam-IV H-Shield H-Shield-CG DensDeck Test Product Specification Description ASTM D 6509 Modified Bitumen coated fiberglass base sheet. ASTM D1970 Self -adhering, fiberglass reinforced, SBS modified bitumen base/ply sheet. ASTM D 1970 Self -adhering fiberglass reinforced ASTM D4601 Type I modified bitumen base sheet ASTM D 4601, Grade S, Type II ASTM D 1970 ASTM D 3019 TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Water resistant gypsum board DensDeck Prime Water resistant gypsum board ENRGY 3 Polyisocyanurate foam insulation ENRGY 3 25 PSI Polyisocyanurate foam insulation FescoBoard Expanded mineral fiber insulation SECUROCK Gypsum -Fiber Roof Board Gypsum insulation DuraBoard Expanded mineral fiber insulation Structodek High Density Fiberboard Roof Wood fiber insulation board Insulation APPROVEraAMwldAne i Self -adhering, fiberglass reinforced, SBS modified bitumen base/ply sheet. Cold applied, SBS polymer modified asphalt adhesive. Manufacturer (With Current NOA CertainTeed LLC. CertainTeed LLC. CertainTeed LLC. CertainTeed LLC. Atlas Roofing Corp. Atlas Roofing Corp. Atlas Roofing Corp. Hunter Panels LLC Hunter Panels LLC Georgia Pacific Gypsum LLC Georgia Pacific Gypsum LLC Johns Manville Corp. Johns Manville Corp. Johns Manville Corp. USG Corp. Johns Manville Corp. Blue Ridge Fiberboard, Inc. NOA No.: 20-0723.27 Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 4 of 87 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer Mith Current NOA ISO 95+ GL Polyisocyanurate Insulation Firestone Building Products Company, LLC Insulfoam EPS Expanded Polystyrene Insulfoam, a Div. of Carlisle Const. Materials APPROVED FASTENERS/ADHESIVES: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions N'ith Current NOA 1. Dekfast DF-#14-PH3 Insulation fastener for wood, various SFS Group USA, Inc. steel and concrete decks 2. Dekfast DF-#15-PH3 Insulation fastener for wood, various SFS Group USA, Inc. steel and concrete decks 3. Dekfast PLT-H-2-7/8 Galvalume hex stress plate. 2 7/8" x 3 1/4" SFS Group USA, Inc. 4. Dekfast PLT-P-R-3 Polypropylene locking plate. 3" x 3 1/4" SFS Group USA, Inc. 5. #14 Roofgrip Insulation fastener various OMG, Inc. 6. ASAP RoofGrip Pre- Pre -assembled Insulation various OMG, Inc. Assembled System fastener and plate 7. 3 in. Round Metal Plate Galvalume AZ50 steel plate 3" round OMG, Inc. 8. Dekfast DF-#14-PH3-P3 Pre -assembled Insulation various SFS Group USA, Inc. fastener and plate 9. Trufast #14 HD Fastener Insulation fastener for wood and various Altenloh, Brinck & Co. U.S., steel decks Inc. 10. Trufast 3" Metal Insulation Galvalume AZ50 steel plate 3" round Altenloh, Brinck & Co. U.S., Plate Inc. 11. Trufast 2.4" Barbed Metal Galvalume AZ50 steel plate 2.4" round Altenloh, Brinck & Co. U.S., Seam Plate Inc. 12. FlintFast #14 Insulation and membrane Various CertainTeed LLC. fastener 13. FlintFast 3" Insulation Galvalume AZ50 steel plate 3" round CertainTeed LLC. Plate 14. Trufast #15 EHD Fastener Coated carbon steel screw Various Altenloh, Brinck & Co. U.S., Inc. 15. Trufast 2" Metal Seam Galvalume steel stress plate 2" round Altenloh, Brinck & Co. U.S., Plate Inc. 16. Dekfast PLT-R-3 Steel, Galvalume AZ50 stress 3" round SFS Group USA, Inc. plate for use with all Dekfast fasteners NOA No.: 20-0723.27 MiAmFnanE coin Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 5 of 87 APPROVED FASTENERS/ADHESIVES: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions(With Current NOA) 17. OMG 3" Galvalume Steel Galvalume coated steel plate for 3" round OMG, Inc. Plate use with approved fasteners screw. 18. 3 in. Ribbed Galvalume Round Galvalume plated steel 3" round OMG, Inc. Plate stress plate with reinforcing ribs for use with OMG fasteners. 19. AccuTrac Plate Galvalume steel plate for use 3" square OMG, Inc. with Standard Roofgrip and Standard Hex Head fasteners. 20. AccuTrac Flat Bottom A2-SS aluminized steel plate for 3" square OMG, Inc. use with #12 Roofgrip, #14 Roofgrip and #15 Roofgrip. 21. Flat Bottom Metal Plate A2-SS aluminized steel plate for 3" square OMG, Inc. use with #12, #14 or #15 Roofgrip. 22. Trufast 3" Recessed Metal Galvalume steel stress plate for 3" round Altenloh, Brinck & Co. U.S., Insulation Plate use with Trufast fasteners Inc. 23. Trufast 3" TL Insulation Galvalume steel stress plate for 3" round Altenloh, Brinck & Co. U.S., Plate use with Trufast TL fasteners Inc. 24. F1intFast 2.4" Barbed Galvalume AZ50 steel plate 2.4" round CertainTeed LLC. Seam Plate 25. F1intFast 3" Recessed Galvalume steel stress plate for 3" round CertainTeed LLC. Insulation Plate use with F1intFast fasteners 26. Millennium One Step Polyurethane two component See Published H.B. Fuller Company Foamable Adhesive high rise insulation adhesive Details 27. Millennium One Step Polyurethane two component 1.5 liters H.B. Fuller Company Green Foamable Adhesive high rise insulation adhesive 28. Millennium PG-1 Low Polyurethane two component 1.5 liters H.B. Fuller Company Viscosity Insulation low rise insulation adhesive Adhesive 29. ICP Adhesive CR-20 Polyurethane two component Two kits (A = ICP Adhesives & Sealants, low rise insulation adhesive 401b and B = Inc. 351b cylinders) 30. Pliodeck Insulation Polyurethane one component See Published Ashland, Inc. Adhesive low VOC adhesive system Details 31. Insta Stik Quik Set Polyurethane one component It is supplied The Dow Chemical Company Insulation moisture curing adhesive in pressurized cylinders with a net weight of 23 lbs., with a total unit weight of 30 lbs. NOA No.: 20-0723.27 !NG►lMMADE COUNTY Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 6 of 87 APPROVED FASTENERS/ADHESIVES: TABLE 3 Fastener Product Product Manufacturer Number Name Descrilition Dimensions(With Current NOA 32. OMG OlyBond 500 Spray polyurethane foam 10 gal. bag -in- OMG, Inc. Adhesive insulation adhesive box set and 1.5 liters SpotShot cartridge 33. OMG OlyBond 500 Green Spray polyurethane foam 10 gal. bag -in- OMG, Inc. Adhesive insulation adhesive box set and 1.5 liters SpotShot cartridge APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. S� stem. Number Manufacturer Application 1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. CertainTeed LLC. F1intCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 20-0723.27 Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 7 of 87 EVIDENCE SUBMITTED: Test A(, encv/Identifier Name Report Date Factory Mutual Research Corp. FM 4470 3Y8A1.AM 03/23/96 FM 4470 OD3A3.AM 04/04/97 FM 4470 1D7A4.AM 11/09/98 FM 4470 2DOAO.AM 12/23/98 FM 4470 3023458 07/18/06 FM 4470 3024177 07/18/06 FM 4470 3024311 11/01/06 FM 4470 3031350 09/27/07 FM 4470 3036182 07/31/09 FM 4470 3037127 01/11/10 FM 4470 3039046 06/15/10 FM 4470 3039848 12/02/11 FM 4470 3046104 08/13/13 FM 4470 3048520 09/19/13 Underwriters Laboratories, Inc. UL 790 R11656 01/11/13 Dynatech Engineering Corp. TAS 114 3504-12.94-1 10/16/95 United States Testing Company ASTM D 5147 97-457-2R 12/02/87 ASTM D 5147 97457-4 06/03/88 Momentum Technologies, Inc. ASTM D 6164 AX31G817 06/05/09 TrinityjERD TAS 114 (J) #3504.06.01-1 06/05/01 TAS 114 3521.07.04 07/29/04 TAS 114 (H) Letter 04/05/06 TAS 117 (B) 3503.10.06 10/10/06 TAS 117 (B) 06490.04.07-R1 06/27/07 TAS 114 3533.01.06-R1 10/26/07 TAS 117 (B) / ASTM D 6862 C8500SC.11.07 11/30/07 TAS 114 C8370.08.08 08/19/08 TAS 117 & TAS 114 C30560.03.10 03/18/10 TAS 117 & TAS 114 C30560.06.10 06/10/10 FM 4474 / TAS 114 C31420.08.10 09/21/10 ASTM D 6164 / D 4798 C31410.01.11-2 01/10/11 TAS 117 B C35500.02.11 02/09/11 FM 4474 / TAS 114 C37820.07.12 07/24/12 ASTM D1876, TAS 114 (H), C42110.08.12 08/13/12 TAS 117 (B) ASTM D 4601 C40050.09.12-1 09/28/12 ASTM D 1970 C40050.09.12-2 09/28/12 ASTM D 5147 / D 4798 C31410.10.10-R1 11/01/12 ASTM D 5147 / D 4798 C31410.01.11-1-R1 11/01/12 ASTM D 4798 C31410.01.11-2A-R1 02/21/13 ASTM D 1876 / TAS 114 (H) / C44580.07.13 07/25/13 FM 4474 ASTM D 4798 C31410.12.13 12/05/13 NOA No.: 20-0723.27 MAMI-DADE COUNTY Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 8 of 87 EVIDENCE SUBMITTED: Test A-gency/Identifier Name Report Date ASTM D 6222 C40050.12.13-R1 12/31/13 ASTM D4601 CTR-SC8740.04.15-R2 04/21/15 ASTM D 2178 C47250.03.14 03/26/14 ASTM D 1876, TAS 114 (H), C45620.03.14 03/27/14 FM 4474 ASTM D 1876, TAS 114 (H), C47320.03.14-RI 04/01/15 FM 4474 ASTM D 1876 C35460.05.11-R1 05/20/15 FM 4474 / UL1897 / TAS 114 (D) CTR-SC9935.01.16-RI 01/19/16 FM 4474 / TAS 114 (D) CTR-SC9175.09.16-1 09/06/16 ASTM D 4601 CTR-SC11145.09.16- 09/19/16 3C ASTM D 4601-04 (2012), Type II CTR-SC11145.09.16- 09/19/16 3A ASTM D 6163 CTR-SC11145.09.16- 09/19/16 5A ASTM D 6222 CTR-SC11145.09.16- 09/19/16 7A FM 4474 (B) / TAS 114 (D) 3522.07.04-R1 12/22/16 TAS 114 (D) CTR-SC15775.10.17 10/31/17 PRI Construction Materials ASTM D6163 CTC-056-02-01 08/25/10 Technologies LLC ASTM D 6163 CTC-066-02-01 08/09/11 ASTM D 6222 CTC-071-02-01 08/08/11 ASTM D 6164 / D 4798 CTC-093-02-01 08/09/11 ASTM D 4601 CTC-126-02-01 03/12/12 ASTM D 2178 CTC-123-02-01 03/13/12 ASTM D 6509 CTC-116-02-01 04/04/12 ASTM D 6163 CTC-128-02-01 06/11/12 ASTM D 6163 CTC-129-02-01 06/11/12 ASTM D 6164 CTC-132-02-01 06/11/12 ASTM D 6164 CTC-161-02-01 05/09/13 ASTM D 6162 CTC-183-02-01 10/02/13 ASTM D 6164 CTC-190-02-01 12/02/13 ASTM D 6163 CTC-319-02-01 08/22/17 ASTM D 4601 CTC-321-02-01 08/22/17 ASTM D 1970 CTC-320-02-01 08/28/17 Dynatech Engineering Corp. TAS 114 3504-12.94-1 10/16/95 NOA No.: 20-0723.27 Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 9 of 87 Membrane Type: SBS Modified Deck Type 3I: Concrete Decks, Non -Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type F(6): Base sheet adhered with approved asphalt. All General and System Limitations apply. Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of base sheet. Base Sheet: One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the non -insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base self -adhered to the non -insulated substrate. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20. Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Flintlastic Ultra Poly SMS Base Sheet torch applied or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self adhered. Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR- P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T torch adhered to base or ply sheet. Surfacing: (Optional) Maximum Design Pressure: APPROVED Any of the approved surfacing/coating options listed in Table 4. -635 psf (See General Limitation #9) NOA No.: 20-0723.27 Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 83 of 87 CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 20-0723.27 MAAlF�rY Expiration Date: 05/19/23 Approval Date: 09/17/20 Page 87 of 87