Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
specs
October 2020 2222--11889977--11LL--EENN Convertible Air Handlers 1–1/2 —5 Ton TEM4A0B18S21SB TEM4A0B19M21SA TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B31M31SA TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C43M41SA TEM4A0C48S41SB TEM4A0C49M41SA TEM4A0C60S51SB TEM4A0C61M51SA The TEM4 series air handler is designed for installation in a closet, utility room,alcove,basement,crawlspace or attic.These versatile units are applicable to air conditioning and heat pump applications.Several models are available to meet the specific requirements of the outdoor equipment.Field installed electric resistance heaters are available. Product Data 2 22-1897-1L-EN Features and Benefits ..........................................................3 Optional Equipment..........................................................3 Product Specifications .........................................................4 Heater Pressure Drop Table TEM Air Handler Models ..........................8 Minimum Airflow CFM ........................................................9 Air Handler and Heater Matrix Allowable Combinations ........................11 Performance and Electrical Data ..............................................12 Electrical Data ................................................................25 Field Wiring...................................................................26 TEM Convertibility ............................................................27 TEM4 Air Handler Dimensional Data ..........................................28 Outline Drawing ..............................................................29 Table of Contents 22-1897-1L-EN 3 Features and Benefits •Painted metal cabinet with captured foil face insulation •2%or less air leakage •R-4.2 Insulating Value •Multi-Position UP/Down Flow,Horizontal Left /Right •ALL Aluminum Coil with Enhanced Patented Coil Fin •Electric Heaters with polarized plug connections (sold as accessory) •R-410A Thermal Expansion Valve •ECM Motor ((33..55 ––55 TToonn MMooddeellss )) •Low Voltage Pigtail Connections •Draw Through Design •Horizontal Drain pan •Fused 24V Power •33 yyeeaarr wwaarrrraannttyy •1100--yyeeaarr wwaarrrraannttyy rreeggiisstteerreedd •OOppttiioonnaall eexxtteennddeedd wwaarrrraannttyy aavvaaiillaabbllee IImmppoorrttaanntt::Condensate management kit is required for all 5 ton air handler models installed in downflow applications. Optional Equipment Accessory Number Description Fits Cabinet Size BAYHTR1504BRK Electric Heater,4KW,Breaker,24V Control,1 Ph 18.5”and 23.5” BAYHTR1504PDC Electric Heater,4KW,Pull Disconnect,24V Control,1 Ph 18.5”and 23.5” BAYHTR1504LUG Electric Heater,4KW,Lug,24V Control,1 Ph 18.5”and 23.5” BAYHTR1505BRK Electric Heater,5KW,Breaker,24V Control,1 Ph 18.5”and 23.5” BAYHTR1505PDC Electric Heater,5KW,Pull Disconnect,24V Control,1 Ph 18.5”and 23.5” BAYHTR1505LUG Electric Heater,5KW,Lug,24V Control,1 Ph 18.5”and 23.5” BAYHTR1508BRK Electric Heater,8KW,Breaker,24V Control,1 Ph 18.5”and 23.5” BAYHTR1508PDC Electric Heater,8KW,Pull Disconnect,24V Control,1 Ph 18.5”and 23.5” BAYHTR1508LUG Electric Heater,8KW,Lug,24V Control,1 Ph 18.5”and 23.5” BAYHTR1510BRK Electric Heater,10KW,Breaker,24V Control,1 Ph 18.5”and 23.5” BAYHTR1510PDC Electric Heater,10KW,Pull Disconnect,24V Control,1 Ph 18.5”and 23.5” BAYHTR1510LUG Electric Heater,10KW,Lug,24V Control,1 Ph 18.5”and 23.5” BAYHTR3510LUG Electric Heater,10KW,Lug,24V Control,3 Ph 18.5”and 23.5” BAYHTR1515BRK Electric Heater,15KW,Breaker,24V Control,1 Ph 18.5”and 23.5” BAYHTR1517BRK Electric Heater,15KW,Breaker,24V Control,1 Ph 18.5”and 23.5” BAYHTR3515LUG Electric Heater,15KW,Lug,24V Control,3 Ph 18.5”and 23.5” BAYHTR3517LUG Electric Heater,15KW,Lug,24V Control,3 Ph 18.5”and 23.5” BAYHTR1519BRK Electric Heater,20KW,Breaker,24V Control,1 Ph 18.5” BAYHTR1520BRK Electric Heater,20KW,Breaker,24V Control,1 Ph 23.5” BAYHTR1521BRK Electric Heater,20KW,Breaker,24V Control,1 Ph 23.5” BAYHTR1523BRK Electric Heater,20KW,Breaker,24V Control,1 Ph 23.5” BAYHTR1525BRK Electric Heater,25KW,Breaker,24V Control,1 Ph 23.5” BAYTEMSPFG1A Supply Duct Flange Kit 18.5”and 23.5” BAYSPEKT201A Single Point Power Entry Kit 18.5”and 23.5” BAYTEMDFKT1A (a)Downflow Condensate Management Kit 23.5”(5 Ton only) TAYBASE185 Air Handler Downflow Sub-Bases 18.5” TAYBASE235 (TAYBASE 100)Air Handler Downflow Sub-Bases 23.5” BAYSF1185AAA Slim Fit Filter Box 18.5” BAYSF1235AAA Slim Fit Filter Box 23.5” TEMBRKSEALT01A Breaker Seal Kit for sure with BAYHTR15 4kW —20kW Heaters 18.5”and 23.5” TEMBRKSEALT25A Breaker Seal Kit for use with 25 kW electric heaters &heater kits used with BAYSPEKT201 18.5”and 23.5” (a)Required with all 5–ton air handler models in downflow orientation. 4 22-1897-1L-EN Product Specifications MODEL TEM4A0B18S21SB TEM4A0B19M21SA TEM4A0B24S21SB TEM4A0B30S31SB RATED VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 RATINGS(a)See O.D.Specifications See O.D.Specifications See O.D.Specifications See O.D.Specifications INDOOR COIL —Type Plate Fin Plate Fin Plate Fin Plate Fin Rows —F.P.I.3 -14 3 -14 3 -14 3 -14 Face Area (sq.ft.)4.37 4.37 4.37 4.37 Tube Size (in.)3/8 3/8 3/8 3/8 Refrigerant Control TXV TXV TXV TXV Drain Conn.Size (in.)(b)3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing INDOOR FAN —Type Centrifugal Centrifugal Centrifugal Centrifugal Diameter-Width (In.)11 X 6 11 X 6 11 X 6 11 X 8 No.Used 1 1 1 1 Drive -No.Speeds Direct -3 Direct -4 Direct -3 Direct -3 CFM vs.in.w.g.See Fan Performance Table See Fan Performance Table See Fan Performance Table See Fan Performance Table No.Motors —H.P.1 -1/5 1 -1/3 1 -1/5 1 -1/3 Motor Speed R.P.M.825 1050 825 825 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 1.2 2.8 1.2 2.0 FILTER Filter Furnished?(c)No No No No REFRIGERANT R-410A R-410A R-410A R-410A Ref.Line Connections Brazed Brazed Brazed Brazed Coupling or Conn.Size —in. Gas 3/4 3/4 3/4 3/4 Coupling or Conn.Size —in. Liq.3/8 3/8 3/8 3/8 DIMENSIONS H x W x D H x W x D H x W x D H x W x D Crated (In.)46 x 21 x 24 46 x 21 x 24 46 x 21 x 24 46 x 21 x 24 Uncrated 45-1/8 x 18-1/2 x 21-1/8 45-1/8 x 18-1/2 x 21-1/8 45-1/8 x 18-1/2 x 21-1/8 45-1/8 x 18-1/2 x 21-1/8 WEIGHT Shipping (Lbs.)/Net (Lbs.)116/110 116/110 116/110 116/110 (a)These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b)3/4”Male Plastic Pipe (Ref:ASTM 1785–76) (c)Remote filter required. 22-1897-1L-EN 5 MODEL TEM4A0B31M31SA TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB RATED VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 RATINGS(a)See O.D.Specifications See O.D.Specifications See O.D.Specifications See O.D.Specifications INDOOR COIL —Type Plate Fin Plate Fin Plate Fin Plate Fin Rows —F.P.I.4 -14 3 -14 3 -14 3 -14 Face Area (sq.ft.)3.44 4.37 5.50 5.50 Tube Size (in.)3/8 3/8 3/8 3/8 Refrigerant Control TXV TXV TXV TXV Drain Conn.Size (in.)(b)3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing INDOOR FAN —Type Centrifugal Centrifugal Centrifugal Centrifugal Diameter-Width (In.)11 X 8 11 X 8 11 X 8 11 X 8 No.Used 1 1 1 1 Drive -No.Speeds Direct -5 Direct -3 Direct -3 Direct -3 (c) CFM vs.in.w.g.See Fan Performance Table See Fan Performance Table See Fan Performance Table See Fan Performance Table No.Motors —H.P.1 -1/3 1 -1/3 1 -1/3 1 -1/2 Motor Speed R.P.M.1050 825 825 1050 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 2.8 2.0 2.5 4.1 FILTER Filter Furnished?(d)No No No No REFRIGERANT R-410A R-410A R-410A R-410A Ref.Line Connections Brazed Brazed Brazed Brazed Coupling or Conn.Size —in. Gas 3/4 3/4 7/8 7/8 Coupling or Conn.Size —in. Liq.3/8 3/8 3/8 3/8 DIMENSIONS H x W x D H x W x D H x W x D H x W x D Crated (In.)48-1/4 x 22-1/2 x 25-1/2 46 x 21 x 24 52–1/2 x 26 x 24 52–1/2 x 26 x 24 Uncrated 46-3/4 x 18-1/2 x 21-1/8 45-1/8 x 18-1/2 x 21-1/8 51-3/8 x 23-1/2 x 21-1/8 51-3/8 x 23-1/2 x 21-1/8 WEIGHT Shipping (Lbs.)/Net (Lbs.)145/138 116/110 145/138 145/138 (a)These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b)3/4”Male Plastic Pipe (Ref:ASTM 1785–76) (c)ECM Motor (d)Remote filter required. PPrroodduucctt SSppeecciiffiiccaattiioonnss 6 22-1897-1L-EN MODEL TEM4A0C43M41SA TEM4A0C48S41SB TEM4A0C49M41SA TEM4A0C60S51SB RATED VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 RATINGS(a)See O.D.Specifications See O.D.Specifications See O.D.Specifications See O.D.Specifications INDOOR COIL —Type Plate Fin Plate Fin Plate Fin Plate Fin Rows —F.P.I.4 -14 3 -14 3 -16 4 -14 Face Area (sq.ft.)4.59 5.50 7.9 5.91 Tube Size (in.)3/8 3/8 3/8 3/8 Refrigerant Control TXV TXV TXV TXV Drain Conn.Size (in.)(b)3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing INDOOR FAN —Type Centrifugal Centrifugal Centrifugal Centrifugal Diameter-Width (In.)11 X 8 11 X 8 11 X 11 11 X 11 No.Used 1 1 1 1 Drive -No.Speeds Direct -5 (c)Direct -3 (c)Direct -5 (c)Direct -3 (c) CFM vs.in.w.g.See Fan Performance Table See Fan Performance Table See Fan Performance Table See Fan Performance Table No.Motors —H.P.1 -1/2 1 -3/4 1 -3/4 1 -3/4 Motor Speed R.P.M.1050 1050 1050 1050 Volts/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 F.L.Amps 4.1 6.0 6.0 6.0 FILTER Filter Furnished?(d)No No No No REFRIGERANT R-410A R-410A R-410A R-410A Ref.Line Connections Brazed Brazed Brazed Brazed Coupling or Conn.Size —in. Gas 7/8 7/8 7/8 7/8 Coupling or Conn.Size —in. Liq.3/8 3/8 3/8 3/8 DIMENSIONS H x W x D H x W x D H x W x D H x W x D Crated (In.)52-3/4 x 27-1/2 x 25-1/2 52–1/2 x 26 x 24 57-1/8 x 27-1/2 x 25-1/2 52–1/2 x 26 x 24 Uncrated 51-3/8 x 23-1/2 x 21-1/8 51-3/8 x 23-1/2 x 21-1/8 55-3/4 x 23-1/2 x 21-1/8 51-3/8 x 23-1/2 x 21-1/8 WEIGHT Shipping (Lbs.)/Net (Lbs.)155/144 145/138 185/174 145/138 (a)These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b)3/4”Male Plastic Pipe (Ref:ASTM 1785–76) (c)ECM Motor (d)Remote filter required. PPrroodduucctt SSppeecciiffiiccaattiioonnss 22-1897-1L-EN 7 MODEL TEM4A0C61M51SA RATED VOLTS/PH/HZ 208-230/1/60 RATINGS(a)See O.D.Specifications INDOOR COIL —Type Plate Fin Rows —F.P.I.3 -16 Face Area (sq.ft.)7.9 Tube Size (in.)3/8 Refrigerant Control TXV Drain Conn.Size (in.)(b)3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN —Type Centrifugal Diameter-Width (In.)11 X 11 No.Used 1 Drive -No.Speeds Direct -5 (c) CFM vs.in.w.g.See Fan Performance Table No.Motors —H.P.1 -3/4 Motor Speed R.P.M.1050 Volts/Ph/Hz 208-230/1/60 F.L.Amps 6.0 FILTER Filter Furnished?(d)No REFRIGERANT R-410A Ref.Line Connections Brazed Coupling or Conn.Size —in. Gas 7/8 Coupling or Conn.Size —in. Liq.3/8 DIMENSIONS H x W x D Crated (In.)57-1/8 x 27-1/2 x 25-1/2 Uncrated 55-3/4 x 23-1/2 x 21-1/8 WEIGHT Shipping (Lbs.)/Net (Lbs.)185/174 (a)These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b)3/4”Male Plastic Pipe (Ref:ASTM 1785–76) (c)ECM Motor (d)Remote filter required. PPrroodduucctt SSppeecciiffiiccaattiioonnss 8 22-1897-1L-EN Heater Pressure Drop Table TEM Air Handler Models Airflow CFM Number of Racks Heater Racks 1 2 3 4 Heater Model No.of Racks Air Pressure Drop —Inches W.G.BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR3510 3 1400 0.02 0.04 0.06 0.12 BAYHTR1515 3 1300 0.02 0.04 0.05 0.11 BAYHTR1517 3 1200 0.01 0.04 0.05 0.10 BAYHTR3515 3 1100 0.01 0.03 0.05 0.09 BAYHTR3517 3 1000 0.01 0.03 0.04 0.09 BAYHTR1519 4 900 0.01 0.03 0.04 0.08 BAYHTR1520 4 800 0.01 0.03 BAYHTR1521 4 700 0.01 0.02 BAYHTR1523 4 600 0.01 0.02 BAYHTR1525 4 22-1897-1L-EN 9 Minimum Airflow CFM TEM4A0B18S21SB,TEM4A0B24S21SB Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG,BAYHTR1505BRK,BAYHTR1505LUG Med Low BAYHTR1508BRK,BAYHTR1508LUG,BAYHTR1510BRK,BAYHTR1510LUG, BAYHTR3510LUG Med Low TEM4A0B19M21SA Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG, BAYHTR1505BRK,BAYHTR1505LUG Low Low BAYHTR1508BRK,BAYHTR1508LUG, BAYHTR1510BRK,BAYHTR1510LUG, BAYHTR3510LUG High Med TEM4A0B30S31SB,TEM4A0B36S31SB Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG,BAYHTR1505BRK,BAYHTR1505LUG Low Low BAYHTR1508BRK,BAYHTR1508LUG,BAYHTR1510BRK BAYHTR1510LUG, BAYHTR3510LUG Low Low BAYHTR1517BRK Med Low BAYHTR3517LUG High Low TEM4A0B31M31SA Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG, BAYHTR1505BRK,BAYHTR1505LUG Low Low BAYHTR1508BRK,BAYHTR1508LUG, BAYHTR1510BRK,BAYHTR1510LUG Med-High Med-Low BAYHTR1517BRK,BAYHTR3517LUG, BAYHTR3510LUG High Med TEM4A0C37S31SB Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG,BAYHTR1505BRK,BAYHTR1505LUG Low Low BAYHTR1508BRK,BAYHTR1508LUG,BAYHTR1510BRK,BAYHTR1510LUG, BAYHTR3510LUG Low Low BAYHTR1517BRK Low Low BAYHTR1523BRK High High BAYHTR3517LUG Low Low 10 22-1897-1L-EN TEM4A0C42S41SB Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG,BAYHTR1505BRK,BAYHTR1505LUG Low Low BAYHTR1508BRK,BAYHTR1508LUG,BAYHTR1510BRK,BAYHTR1510LUG, BAYHTR3510LUG Low Low BAYHTR1517BRK Low Low BAYHTR1523BRK Med Low BAYHTR3517LUG Low Low TEM4A0C43M41SA Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG, BAYHTR1505BRK,BAYHTR1505LUG Low Low BAYHTR1508BRK,BAYHTR1508LUG, BAYHTR1510BRK,BAYHTR1510LUG Med-High Med-Low BAYHTR1523BRK Med-High Med BAYHTR1517BRK,BAYHTR3517LUG, BAYHTR3510LUG High Med TEM4A0C48S41SB,TEM4A0C60S51SB Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG,BAYHTR1505BRK,BAYHTR1505LUG Low Low BAYHTR1508BRK,BAYHTR1508LUG,BAYHTR1510BRK,BAYHTR1510LUG, BAYHTR3510LUG Low Low BAYHTR1517BRK Low Low BAYHTR1523BRK Low Low BAYHTR1525BRK Low Low BAYHTR3517LUG Low Low TEM4A0C49M41SA,TEM4A0C61M51SA Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG, BAYHTR1505BRK,BAYHTR1505LUG, BAYHTR1508BRK,BAYHTR1508LUG, BAYHTR1510BRK,BAYHTR1510LUG, BAYHTR3510LUG Med-Low Med-Low BAYHTR1517BRK,BAYHTR3517LUG Med Med BAYHTR1523BRK,BAYHTR1525BRK Med-High Med MMiinniimmuumm AAiirrffllooww CCFFMM 22-1897-1L-EN 11 Air Handler and Heater Matrix Allowable Combinations Table 1.TEM4 MINIMUM HEATER AIRFLOW CFM —HEATER MATRIX ModelNo.BAYHTR1504BRK*BAYHTR1504PDC*BAYHTR1504LUG*BAYHTR1505BRK*BAYHTR1505PDC*BAYHTR1505LUG*BAYHTR1508BRK*BAYHTR1508PDC*BAYHTR1508LUG*BAYHTR1510BRK*BAYHTR1510PDC*BAYHTR1510LUG*BAYHTR3510LUG*BAYHTR1517BRK*BAYHTR1523BRK*BAYHTR1525BRK*BAYHTR3517LUG*TEM4A0B18S21SB *L /M L /M ———————— TEM4A0B19M21SA *L /L M /H ———————— TEM4A0B24S21SB *L /M L /M ———————— TEM4A0B30S31SB *L /L L /L L /M ————L /H TEM4A0B31M31SA *L /L M-L /M-H M /H ————M /H TEM4A0B36S31SB *L /L L /L L /M ————L /H TEM4A0C37S31SB *L /L L /L L /L H /H ——L /L TEM4A0C42S41SB *L /L L /L L /L L /M ——L /L TEM4A0C43M41SA *L /L M-L /M-H M /H M /M-H ——M /H TEM4A0C48S41SB *L /L L /L L /L L /L L /L L /L TEM4A0C49M41SA *M-L /M-L M-L /M-L M /M M /M-H M /M-H M /M TEM4A0C60S51SB *L /L L /L L /L L /L L /L L /L TEM4A0C61M51SA *M-L /M-L M-L /M-L M /M M /M-H M /M-H M /M 1.Cooling /HP Airflow 2.*=Followed by two digits MMiinniimmuumm AAiirrffllooww CCFFMM 12 22-1897-1L-EN Performance and Electrical Data Table 2.Air Flow Performance TEM4A0B18S21SB,TEM4A0B24S21SB (a) EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —230 VOLTS Speed Taps —208 VOLTS High Med Low †High Med Low † 0.1 1094 927 773 1052 849 658 0.2 1032 880 735 990 807 624 0.3 955 818 678 915 750 578 0.4 864 739 601 826 679 518 0.5 759 645 505 723 591 441 0.6 639 534 389 606 490 0.7 505 408 476 374 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory setting (a)For the TEM4A0B24S21SB,the recommended speed tap is medium at 0.4”external static pressure. Table 3.Electrical Data TEM4A0B18S21SB,TEM4A0B24S21SB Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 1.2 *2 15 1.2 *2 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.84 13100 16.0 22 25 2.88 9800 13.8 19 20 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.80 16400 20.0 27 30 3.60 12300 17.3 23 25 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.68 26200 32.0 42 45 5.76 19700 27.7 36 40 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.60 32800 40.0 52 60 7.20 24600 34.6 45 45 BAYHTR3510LUG 1/3 9.60 32800 23.1 30 30 7.20 24600 20.0 26 30 *=Motor Amps 22-1897-1L-EN 13 Table 4.Air Flow Performance TEM4A0B19M21SA EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —208 –230 VOLTS High Med-High Med †Low 0.1 860 773 652 589 0.2 817 732 589 528 0.3 767 679 515 445 0.4 709 612 431 339 0.5 644 533 336 210 0.6 571 441 232 0.7 491 336 116 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory Setting 4.Low =Taps 1–2,Med =Tap 3,Med-High=Tap 4,High =Tap 5 Table 5.Electrical Data TEM4A0B19M21SA Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 4.1 *8 15 4.1 *8 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.8 13100 16.0 28 30 2.9 9800 13.8 25 25 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 33 35 3.6 12300 17.3 29 30 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.7 26200 32.0 48 50 5.8 19700 27.7 42 45 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR3510LUG 1/3 9.6 32800 23.1 36 40 7.2 24600 20.0 32 35 *=Motor Amps PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 14 22-1897-1L-EN Table 6.Air Flow Performance TEM4A0B30S31SB,TEM4A0B36S31SB EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —230 VOLTS Speed Taps —208 VOLTS High Med Low †High Med Low † 0.1 1391 1305 1059 1338 1146 902 0.2 1305 1231 1029 1257 1098 868 0.3 1203 1138 970 1159 1027 817 0.4 1083 1027 884 1044 935 753 0.5 948 899 769 913 823 664 0.6 795 752 626 766 692 0.7 626 587 603 542 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory setting 4.In downflow applications,airflow must not exceed 1200 cfm due to condensate blowoff. Table 7.Electrical Data TEM4A0B30S31SB,TEM4A0B36S31SB Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 2.0 *3 15 2.0 *3 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.84 13100 16.0 23 25 2.88 9800 13.8 20 20 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 28 30 3.6 12300 17.3 24 25 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.68 26200 32.0 43 45 5.76 19700 27.7 37 40 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 53 60 7.2 24600 34.6 46 50 BAYHTR1517BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 53 60 7.2 24600 34.6 46 50 BAYHTR1517BRK- Circuit 2 4.8 16400 20.0 25 25 3.6 12300 17.3 22 25 BAYHTR3510LUG 1/3 9.6 32800 23.1 31 35 7.2 24600 20.0 27 30 BAYHTR3517LUG 1/3 14.4 49100 34.6 45 50 10.8 36900 30.0 40 40 BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 49100 60.0 83 90 10.8 36900 51.9 73 80 *=Motor Amps (a)MCA and MOP for circuit 1 contains the motor amps PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 22-1897-1L-EN 15 Table 8.Air Flow Performance TEM4A0B31M31SA EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —208 –230 VOLTS High Med-High Med †Med-Low Low 0.1 1072 985 901 820 661 0.2 1028 940 863 774 605 0.3 983 893 820 722 540 0.4 938 845 772 666 465 0.5 891 795 719 605 381 0.6 844 744 661 539 288 0.7 796 691 598 468 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory Setting 4.In downflow applications,airflow must not exceed 1200 cfm due to condensate blowoff. 5.Low =Tap 1,Med-Low =Tap 2,Med =Tap 3,Med-High=Tap 4,High =Tap 5 Table 9.Electrical Data TEM4A0B31M31SA Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 4.1 *8 15 4.1 *8 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.8 13100 16.0 28 30 2.9 9800 13.8 25 25 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 33 35 3.6 12300 17.3 29 30 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.7 26200 32.0 48 50 5.8 19700 27.7 42 45 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1517BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1517BRK- Circuit 2 4.8 16400 20.0 25 25 3.6 12300 17.3 22 25 BAYHTR3510LUG 1/3 9.6 32800 23.1 36 40 7.2 24600 20.0 32 35 BAYHTR3517LUG 1/3 14.4 49100 34.6 50 50 10.8 36900 30.0 44 45 BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 49200 60.0 83 90 10.8 36900 51.9 73 80 *=Motor Amps (a)MCA and MOP for circuit 1 contains the motor amps. PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 16 22-1897-1L-EN Table 10.Air Flow Performance TEM4A0C37S31SB EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —230 VOLTS Speed Taps —208 VOLTS High Med Low †High Med Low † 0.1 1723 1356 1254 1651 1211 1129 0.2 1682 1340 1259 1631 1216 1123 0.3 1605 1291 1228 1572 1188 1096 0.4 1492 1211 1162 1474 1127 1047 0.5 1343 1100 1059 1336 1032 977 0.6 1158 957 919 1159 905 886 0.7 998 782 942 744 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory setting 4.The recommended speed tap is low at 0.5”external static pressure. 5.In downflow applications,airflow must not exceed 1600 cfm due to condensate blowoff. Table 11.Electrical Data TEM4A0C37S31SB Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 2.5 *3 15 2.5 *3 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.84 13100 16.0 23 25 2.88 9800 13.8 20 20 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 28 30 3.6 12300 17.3 25 25 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.68 26200 32.0 43 45 5.76 19700 27.7 38 40 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 53 60 7.2 24600 34.6 46 50 BAYHTR1517BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 53 60 7.2 24600 34.6 46 50 BAYHTR1517BRK- Circuit 2 4.8 16400 20.0 25 25 3.6 12300 17.3 22 25 BAYHTR1523BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 53 60 7.2 24600 34.6 46 50 BAYHTR1523BRK- Circuit 2 9.6 32800 40.0 50 50 7.2 24600 34.6 43 45 BAYHTR3510LUG 1/3 9.6 32800 23.1 32 35 7.2 24600 20.0 28 30 BAYHTR3517LUG 1/3 14.4 49100 34.6 46 50 10.8 36900 30.0 40 40 BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 49200 60.0 83 90 10.8 36900 51.9 73 80 BAYHTR1523BRK with single circuit power source kit BAYSPEKT201A 1/1 19.2 65600 80.0 108 110 14.4 49200 69.2 94 100 *=Motor Amps (a)MCA and MOP for circuit 1 contains the motor amps PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 22-1897-1L-EN 17 Table 12.Air Flow Performance TEM4A0C42S41SB EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —208–230 VOLTS High Med Low † 0.1 1623 1509 1403 0.2 1583 1465 1357 0.3 1539 1420 1309 0.4 1494 1373 1260 0.5 1450 1326 1211 0.6 1399 1276 1159 0.7 1353 1223 1102 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory setting 4.Low =Taps 1–3,Med =Tap 4,High =Tap 5 5.In downflow applications,airflow must not exceed 1600 cfm due to condensate blowoff. Table 13.Electrical Data TEM4A0C42S41SB Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 4.1 *5 15 4.1 *5 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.84 13100 16.0 25 25 2.88 9800 13.8 22 25 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 30 30 3.6 12300 17.3 27 30 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 55 60 7.2 24600 34.6 48 50 BAYHTR1517BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 55 60 7.2 24600 34.6 48 50 BAYHTR1517BRK- Circuit 2 4.8 16400 20.0 25 25 3.6 12300 17.3 22 25 BAYHTR1523BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 55 60 7.2 24600 34.6 48 50 BAYHTR1523BRK- Circuit 2 9.6 32800 40.0 50 50 7.2 24600 34.6 43 45 BAYHTR3510LUG 1/3 9.6 32800 23.1 33 35 7.2 24600 20.0 30 30 BAYHTR3517LUG 1/3 14.4 49200 34.6 48 50 10.8 36900 30.0 42 45 BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 49200 60.0 83 90 10.8 36900 51.9 73 80 BAYHTR1523BRK with single circuit power source kit BAYSPEKT201A 1/1 19.2 65600 80.0 108 110 14.4 49200 69.2 94 100 *=Motor Amps (a)MCA and MOP for circuit 1 contains the motor amps. PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 18 22-1897-1L-EN Table 14.Air Flow Performance TEM4A0C43M41SA EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —208 –230 VOLTS High Med-High Med †Med-Low Low 0.1 1491.6 1418.1 1302.5 1267.8 1140.4 0.2 1459.7 1384.7 1266.3 1230.1 1096.4 0.3 1425.8 1349.2 1227.8 1189.7 1050.3 0.4 1389.8 1311.3 1187.0 1146.8 1002.1 0.5 1351.6 1271.3 1144.0 1101.4 951.7 0.6 1311.4 1229.0 1098.7 1053.3 899.3 0.7 1269.1 1184.4 1051.1 1002.7 844.7 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory Setting 4.In downflow applications,airflow must not exceed 1600 cfm due to condensate blowoff. 5.Low =Tap 1,Med-Low =Tap 2,Med =Tap 3,Med-High=Tap 4,High =Tap 5 Table 15.Electrical Data TEM4A0C43M41SA Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 4.1 *8 15 4.1 *8 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.8 13100 16.0 28 30 2.9 9800 13.8 25 25 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 33 35 3.6 12300 17.3 29 30 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.7 26200 32.0 48 50 5.8 19700 27.7 42 45 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1517BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1517BRK- Circuit 2 4.8 16400 20.0 25 25 3.6 12300 17.3 22 25 BAYHTR1523BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1523BRK- Circuit 2 9.6 32800 40.0 50 50 7.2 24600 34.6 43 45 BAYHTR3510LUG 1/3 9.6 32800 23.1 36 40 7.2 24600 20.0 32 35 BAYHTR3517LUG 1/3 14.4 49100 34.6 50 50 10.8 36900 30.0 44 45 BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 49200 60.0 83 90 10.8 36900 51.9 73 80 *=Motor Amps (a)MCA and MOP for circuit 1 contains the motor amps. PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 22-1897-1L-EN 19 Table 16.Air Flow Performance TEM4A0C48S41SB EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —208–230 VOLTS High Med Low † 0.1 1784 1698 1634 0.2 1748 1662 1595 0.3 1715 1627 1559 0.4 1682 1591 1521 0.5 1650 1558 1488 0.6 1618 1525 1455 0.7 1499 1494 1422 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory setting 4.Low =Taps 1–3,Med =Tap 4,High =Tap 5 5.In downflow applications,airflow must not exceed 1600 cfm due to condensate blowoff. Table 17.Electrical Data TEM4A0C48S41SB Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 6.0 *8 15 6.0 *8 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.84 13100 16.0 28 30 2.88 9800 13.8 25 25 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 33 35 3.6 12300 17.3 29 30 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.68 26200 32.0 48 50 5.76 19700 27.7 42 45 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1517BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1517BRK- Circuit 2 4.8 16400 20.0 25 25 3.6 12300 17.3 22 25 BAYHTR1523BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1523BRK- Circuit 2 9.6 32800 40.0 50 50 7.2 24600 34.6 43 45 BAYHTR1525BRK- Circuit 1 (a) 4/1 6.0 20500 25.0 39 40 4.5 15400 21.6 35 35 BAYHTR1525BRK- Circuit 2 6.0 20500 25.0 31 35 4.5 15400 21.6 27 30 BAYHTR1525BRK- Circuit 3 6.0 20500 25.0 31 35 4.5 15400 21.6 27 30 BAYHTR1525BRK- Circuit 4 6.0 20500 25.0 31 35 4.5 15400 21.6 27 30 BAYHTR3510LUG 1/3 9.6 32800 23.1 36 40 7.2 24600 20.0 32 35 BAYHTR3517LUG 1/3 14.4 49100 34.6 50 50 10.8 36900 30.0 44 45 PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 20 22-1897-1L-EN Table 17.Electrical Data (continued) TEM4A0C48S41SB BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 49200 60.0 83 90 10.8 36900 51.9 73 80 BAYHTR1523BRK with single circuit power source kit BAYSPEKT201A 1/1 19.2 65600 80.0 108 110 14.4 49200 69.2 94 100 *=Motor Amps (a)MCA and MOP for circuit 1 contains the motor amps. PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 22-1897-1L-EN 21 Table 18.Air Flow Performance TEM4A0C49M41SA,TEM4A0C61M51SA EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —208 –230 VOLTS High Med-High Med †Med-Low Low 0.1 1954.3 1790.6 1578.2 1546.0 1296.6 0.2 1908.4 1733.6 1520.4 1487.4 1223.5 0.3 1860.4 1676.3 1461.2 1427.0 1150.5 0.4 1810.3 1618.9 1400.5 1364.8 1077.4 0.5 1758.1 1561.2 1338.5 1300.6 1004.3 0.6 1703.8 1503.2 1275.1 1234.5 931.3 0.7 1647.4 1445.1 1210.2 1166.6 858.2 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory Setting 4.In downflow applications,airflow must not exceed 1600 cfm due to condensate blowoff. 5.Low =Tap 1,Med-Low =Tap 2,Med =Tap 3,Med-High=Tap 4,High =Tap 5 Table 19.Electrical Data TEM4A0C49M41SA,TEM4A0C61M51SA Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protec- tion Capacity Heater Amps per Circuit Mini- mum Circuit Ampaci- ty Maximum Overload ProtectionkWBTUHkWBTUH No Heater 6.0 *8 15 6.0 *8 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.8 131- 00 16.0 28 30 2.9 9800 13.8 25 25 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 164- 00 20.0 33 35 3.6 123- 00 17.3 29 30 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.7 262- 00 32.0 48 50 5.8 197- 00 27.7 42 45 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 328- 00 40.0 58 60 7.2 246- 00 34.6 51 60 BAYHTR1517BRK- Circuit 1 (a) 2/1 9.6 328- 00 40.0 58 60 7.2 246- 00 34.6 51 60 BAYHTR1517BRK- Circuit 2 4.8 164- 00 20.0 25 25 3.6 123- 00 17.3 22 25 BAYHTR1523BRK- Circuit 1 (a) 2/1 9.6 328- 00 40.0 58 60 7.2 246- 00 34.6 51 60 BAYHTR1523BRK- Circuit 2 9.6 328- 00 40.0 50 50 7.2 246- 00 34.6 43 45 BAYHTR1525BRK- Circuit 1 (a) 4/1 6.0 205- 00 25.0 39 40 4.5 154- 00 21.6 35 35 BAYHTR1525BRK- Circuit 2 6.0 205- 00 25.0 31 35 4.5 154- 00 21.6 27 30 BAYHTR1525BRK- Circuit 3 6.0 205- 00 25.0 31 35 4.5 154- 00 21.6 27 30 BAYHTR1525BRK- Circuit 4 6.0 205- 00 25.0 31 35 4.5 154- 00 21.6 27 30 PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 22 22-1897-1L-EN Table 19.Electrical Data (continued) TEM4A0C49M41SA,TEM4A0C61M51SA BAYHTR3510LUG 1/3 9.6 328- 00 23.1 36 40 7.2 246- 00 20.0 32 35 BAYHTR3517LUG 1/3 14.4 491- 00 34.6 50 50 10.8 369- 00 30.0 44 45 BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 492- 00 60.0 83 90 10.8 369- 00 51.9 73 80 BAYHTR1523BRK with single circuit power source kit BAYSPEKT201A 1/1 19.2 656- 00 80.0 108 110 14.4 492- 00 69.2 94 100 *=Motor Amps (a)MCA and MOP for circuit 1 contains the motor amps. PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 22-1897-1L-EN 23 Table 20.Air Flow Performance TEM4A0C60S51SB EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps —208 –230 VOLTS High Med †Low 0.1 1836 1744 1665 0.2 1790 1698 1612 0.3 1743 1650 1560 0.4 1694 1601 1509 0.5 1644 1550 1457 0.6 1593 1499 1406 0.7 1540 1447 1355 1.Values are with wet coil,no filter,and no heaters 2.CFM Correction for dry coil =Add 3% 3.†=Factory Setting 4.Low =Taps 1–3,Med =Tap 4,High =Tap 5 5.BAYTEMDFKT1A must be used for downflow applications and airflow must not exceed 1800 cfm. Table 21.Electrical Data TEM4A0C60S51SB Heater Model No. No.of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload ProtectionkWBTUHkWBTUH No Heater 6.0 *8 15 6.0 *8 15 BAYHTR1504BRK BAYHTR1504LUG 1/1 3.84 13100 16.0 28 30 2.88 9800 13.8 25 25 BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 33 35 3.6 12300 17.3 29 30 BAYHTR1508BRK BAYHTR1508LUG 1/1 7.68 26200 32.0 48 50 5.76 19700 27.7 42 45 BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1517BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1517BRK- Circuit 2 4.8 16400 20.0 25 25 3.6 12300 17.3 22 25 BAYHTR1523BRK- Circuit 1 (a) 2/1 9.6 32800 40.0 58 60 7.2 24600 34.6 51 60 BAYHTR1523BRK- Circuit 2 9.6 32800 40.0 50 50 7.2 24600 34.6 43 45 BAYHTR1525BRK- Circuit 1 (a) 4/1 6.0 20500 25.0 39 40 4.5 15400 21.6 35 35 BAYHTR1525BRK- Circuit 2 6.0 20500 25.0 31 35 4.5 15400 21.6 27 30 BAYHTR1525BRK- Circuit 3 6.0 20500 25.0 31 35 4.5 15400 21.6 27 30 BAYHTR1525BRK- Circuit 4 6.0 20500 25.0 31 35 4.5 15400 21.6 27 30 BAYHTR3510LUG 1/3 9.6 32800 23.1 36 40 7.2 24600 20.0 32 35 BAYHTR3517LUG 1/3 14.4 49100 34.6 50 50 10.8 36900 30.0 44 45 PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 24 22-1897-1L-EN Table 21.Electrical Data (continued) TEM4A0C60S51SB BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A 1/1 14.4 49200 60.0 83 90 10.8 36900 51.9 73 80 BAYHTR1523BRK with single circuit power source kit BAYSPEKT201A 1/1 19.2 65600 80.0 108 110 14.4 49200 69.2 94 100 *=Motor Amps (a)MCA and MOP for circuit 1 contains the motor amps. PPeerrffoorrmmaannccee aanndd EElleeccttrriiccaall DDaattaa 22-1897-1L-EN 25 Electrical Data Figure 1.TEM4A0B18–C37 Figure 2.TEM4A0B19,B31,C42–C61 26 22-1897-1L-EN Field Wiring Figure 3.Field Wiring Diagrams R G B W1 W2 R B O Y X2 R G B/C O Y W HEAT PUMP SYSTEMS Blue 24 VAC HOT FAN 24 VAC Common SOV COOL/HEAT 1st STAGE HEATING 2nd STAGE EMERGENCY HEAT Thermostat Air Handler Outdoor Unit Pink Black W2 Pink White White X2 AC SYSTEMS R G B W1 B Y R G B/C Y W Blue 24 VAC HOT FAN 24 VAC Common COOLING HEAT Thermostat Air Handler Outdoor Unit In AC systems for multiple stages of electric heat, jumper W1 and W2 together if comfort control has only one stage of heat. 22-1897-1L-EN 27 TEM Convertibility Figure 4.Multi-Position Air Handler *=No Internal Modifications Required. AirflowAirflowAirflowUpflow Condensate Drains Refrigerant Connections Vertical Upflow* Horizontal Right Horizontal Left Condensate Drains AirflowDownflow Condensate Drains Vertical Downflow Horizontal Left* Horizontal Right Condensate Drains Refrigerant Connections 28 22-1897-1L-EN TEM4 Air Handler Dimensional Data W H D Model No.H W D TEM4A0B18S21SB 45.02 18.50 21.13 TEM4A0B19M21SA 45.02 18.50 21.13 TEM4A0B24S21SB 45.02 18.50 21.13 TEM4A0B30S31SB 45.02 18.50 21.13 TEM4A0B31M31SA 46.77 18.50 21.13 TEM4A0B36S31SB 45.02 18.50 21.13 TEM4A0C37S31SB 51.27 23.50 21.13 TEM4A0C42S41SB 51.27 23.50 21.13 TEM4A0C43M41SA 51.27 23.50 21.13 TEM4A0C48S41SB 51.27 23.50 21.13 TEM4A0C49M41SA 55.87 23.50 21.13 TEM4A0C60S51SB 51.27 23.50 21.13 TEM4A0C61M51SA 55.87 23.50 21.13 22-1897-1L-EN 29 Outline Drawing NOTE: THIS UNIT IS APPROVED FOR INSTALLATION CLEARANCES TO COMBUSTIBLE MATERIAL AS STATED ON THE UNIT RATING NAMEPLATE PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Control Gas Line Braze TEM4A0B18,19,24,30,36 45.02 18.50 16.50 16.75 4.68 7.33 18.34 TXV 3/4 TEM4A0B31 46.77 18.50 16.50 16.75 4.68 7.33 20.09 TXV 3/4 TEM4A0C37,42,43,48,60 51.27 23.50 21.50 21.75 7.01 9.66 24.59 TXV 7/8 TEM4A0C49,TEM4A0C61 55.87 23.50 21.50 21.75 4.68 9.66 27.19 TXV 7/8 All dimensions are in inches 30 22-1897-1L-EN NNootteess 22-1897-1L-EN 31 NNootteess Trane -by Trane Technologies (NYSE:TT),a global innovator -creates comfortable,energy efficient indoor environments for commercial and residential applications.For more information,please visit trane.com or tranetechnologies.com. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 22-1897-1L-EN 22 Oct 2020 Supersedes 22-1897-1K-EN (April 2020)©2020 Trane