Loading...
HomeMy WebLinkAboutRevisions, revised evergy calcs to reflect tankless water heater OFFICE USE ONLY: _ DATE FILED: c ,1- Z` PERMIT# 2001-0641 REVISION FEE: 17 —75 RECEIPT# 1• t./ P'rye PLANNING&DEVELOPMENT S COUNTYBUILDING&CODE REGULATION N. 2300 VIRGMA AVENUE; 0 FORT PIERCE,FL 34982-5 b2 f' (772)462-1553 FAX(772) '1 r APPLICATION FOR BUILDING P I s PROJECT INFORMATION 1. LOCATION/S MPANISH ADDRESS: 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: REVISED ENERGY CALC TO REFLECT THE TANKLESS WATER HEATER 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: ST.LUCIE COUNTY CERT.#: 8898 BUSINESS NAME: Wyme Baiidffigorpora ion QUALIFIERS NAMEb South U Suite ADDRESS: R wy. CITY; Fort St. Lucie STATE: ZIP: PHONE(DAYTIME): - FAX: 772 878-7656 4. OWNER/BUILDER INFORMATION: NAME: Wynne Building Corporation ADDRESS: 8000 SouthHwy. 1 Suite 402 CITY: STATE: FL ZIP: 34952 PHONE: (77 2) 878-5513 FAX: (772) 878-7656 5. ARCHITECT/ENGINEER INFORMATION: NAME: BRADEN&BRADEN ADDRESS: CITY: STUART STATE: FL zip: 34996 PHONE(DAYTIME): (772)287-8258 FAX: Revised 07/22/2014 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and,Professional Regulation Residential Performance Method Project Name: WYNNE BUIDDING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE L \_` Permit Office: ST.LUCIE COUNTY City,State;Zip: FT.PIERCE,FL, Permit Number: ' Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location:. FL,Fort Pierce County: St.Lucie(Florida Climate Zone-2 1, New construction or existing New(From Plans) 9. Wall Types(1718.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1478.30 ft2 b.Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units;if multiple family 1 c.N/A R= ft2 4.. Number of Bedrooms 1 d.N/A R= ft2 10.Ceiling Types (1336.0 sgft.) Insulation Area 5. Is this a worst case? Yes a.Under.Attic(Vented) ; R=30.0 1306.00 ft2 - 6. Conditioned floor area above,grade ff) 1306 b.Knee.Wall(Vented) R=19.0 36.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= '.ft2 11.Ducts R ft2 7. Windows(128.9..sgft:) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 120 a. U-Factor. Sgl,U=1.02 76.04 ft2 SHGC: SHGC=0.29. b. U-Factor. Sgl,U=1.03 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a.Central Unit 29.0 SEER:14.00 c. U-Factor: Sgl,U=1.02 12.85 ft2 SHGC: SHGC=0.26 13.Heating systems kBtu/hr Efficiency. d. U.-Factor. N/A ft2 a.Electric Heat Pump. 27.0. HSPF:8.20' SHGC: Area Weighted Average Overhang Depth: 4.701 ft. Area.Weighted Average SHGC: 0.281 14.Hot.water systems 8. Floor Tjrpes (1306.0 sg a.Electric Tankless Cap:1 gallons ft.) Insulation Area EF:0.600 a.Slab On-Grade Edge Insulation R=0.0 1306.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A.- R= ft2 15.Credits None Total Proposed Modified Loads: 43.81 . PASS Glass/Floor Area: 0.099 A Total Baseline Loads: 45.95 I hereby certify that the plans'and specifications covered by Review of the plans and : this calculation are in compliance with the Florida Energy specifications covered by this � ' Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY:• Before construction is completed sr+: DATE: 4-28-202 this building will be inspected for compliance with Section 553.908 * $ I hereby certify that this building,as.designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/ N BUILDING OFFICIAL: . DATE: DATE: - Compliance.requires certification-by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed'in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with.R402.4.1.1 and this project requires an envelope.leakage:test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 4/28/2020 2:17 PM EnergyGaugeO USA.6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition.(2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT.SUMMARY.CHECKLIST REPORT PROJECT Title: WYNNE BUIDL.ING-THE CO Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 1306 Lot# Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180 Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, . New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5.% 2.5% Winter Summer Degree Days Moisture' Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1306 10576.2 SPACES: Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 234 1896.4 No 0 1 1 Yes Yes Yes 2 DEN 144 1166.4 No 0 1 Yes Yes Yes 3 SINK AREA 42 340.2 No 0 1 Yes Yes Yes 4 CLOSET 63 510:3 No 0 1 No Yes Yes 5 GREAT ROOM 452, 3661.2 No 2 1. Yes Yes Yes 6 MASTER BATH 50 405 No 0 1 Yes Yes Yes 7 .POWDER 25 202.5 No 0 1 No Yes Yes 8 KITCHEN 232 1879.2 Yes 0 1 Yes Yes Yes 9 LAUNDRY 40 324 No 0 1 No Yes Yes 10 STORAGE 24 192 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet.. 1 Slab-On-Grade'Edge Insulatio MASTER BEDRO 31 ft 0 234 ft2 _-__ 0 1 0 2 Slab-On-Grade Edge Insulatio DEN 24 ft 0 144 ft2 _ .0 1 0 3 Slab-On-Grade Edge Insulatio SINK AREA 7 ft 0 42 ft2 ___. 0 1 0 r 4 Slab-On-Grade Edge Insulatio CLOSET 1 ft 0 63 ft2 0 1 0 5 Slab-On-Grade Edge Insulatio GREAT ROOM 32 ft 0 452 ft2 ___ 0 1 0 6 Slab-On-Grade Edge Insulatio MASTER BATH 5 ft 0 50 ft2 0 1 0 7Slab-On-Grade Edge Insulatio POWDER 1 ft 0 25ft2 0 1 0 4/28/20.20 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 f , FORM R405-2017 INPUT SUMMARY.CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value. -Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio KITCHEN 38 ft 0 232 ft2 ____ 0 1 0 9Slab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 40 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulatio STORAGE 21 ft 0 24 ft2 0 0 1 ROOF / Roof Gable Roof. Rad Solar SA Emitt Emitt Deck Pitch �! # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg). 1 Hip Metal 1376 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC ' V #. Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1306 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 234 ft2 0.1 Wood 2 Under Attic(Vented) DEN 30 Blown 144 ft2 0.1 Wood 3 Under Attic(Vented) SINK AREA 30 Blown 42 ft2 0.1 Wood 4 Under Attic(Vented) CLOSET 30 Blown 63 ft2 0.1 Wood 5 Under Attic(Vented) GREAT ROOM 30 Blown 452 ft2 0.1 Wood 6 Under Attic(Vented) MASTER BATH 30 Blown 50 ft2 0.1 Wood 7 Under Attic(Vented) POWDER 30 Blown 25 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 232 ft2 0.1 Wood 9 Under.Attic(Vented) LAUNDRY 30 Blown 40 ft2 .0.1 Wood 10 Under Attic(Vented) STORAGE 30 Blown 24 ft2 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19, Blown 30.ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ %' _ 1 S=>N Exterior Concrete Block-Int InsMASTER BE 4.1 18 0 8 1 145.5 ft2 0 0 0.3 0 2 W=>E Exterior Concrete Block-Int InsMASTER BE 4.1 13 0 8 1 105.1 ft2 0 0 0.3 0 3 N=>S Exterior Concrete Block-Int Insul DEN 4.1` 12 0 8 1 97.0 ft2 0 . 0 0.3 0 _ 4 W=>E Exterior Concrete Block-Int Insul DEN 4.1 12 0 8 1 97.0 ft2 0 0 0.3 0 5 S=>N. Exterior Concrete Block-Int Ins0NK AREA 4.1 7 0 . 8 1 56.6 ft2 0 0 0.3' 0 6 N=>S Exterior Concrete Block.-Int InsGREAT•ROO 4.1 22 0 8. 1 177.8 ft2 0 0 0.3 0 7 W=>E Exterior Concrete Block-Int InsGREAT ROO 4.1 10 0. 8 1 80.8 ft2 0 0 0.3 0 8 S=>N Exterior Concrete Block-Int Ins MASTER BA 4.1 5 0 8 1 40.4 ft2 0 0 0.3 0 9 N=>S Exterior Concrete Block-Int InsulKITCHEN 4.1 17 0 8 1 137.4 ft2. 0 0 0.3 0 _10 E=>W Exterior Concrete Block-Int InsulKITCHEN 4.1 16 0 8 1 129.3 ft2 0 0 0.3 0 11 S=>N Exterior Concrete Block-Int InsulKITCHEN 4.1 5 0 8, 1 40.4 ft2 0 0 0.3 0 4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaR6s20l7 FBC 6th Edition(2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY.CHECKLIST REPORT • WALLS Adjacent Space Cavity' Width Height Sheathing Framing Solar Below 12' N=>S Exterior Concrete Block-Int InsulKITCI•IEN 4.1 35 8 1- 282.9 ft2- 0 0 0.3 0 13 N=>S Exterior Concrete Block-Int InsuSTORAGE 4.0999 6 8 48.0 ft2 0 0 0.3 0 14 N=>S Exterior Concrete Block-Int 1nsuBTORAGE 4.0999 5 8 40.0 ft2 0 0 0.3 0 15 N=>S Garage Frame-Wood MASTER BE 11 30 8 0 240.0 ft2 0 .0.23 0.3 0 DOORS' # Omt Door Type Space Storms. U-Value Width Height Area Ft In Ft In 1 E=>W Insulated KITCHEN None .32 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation =>.than ed to Worst Case. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W=>E: 2 Metal Low-E Single Yes 1.02 0.29 N 32.4 ft2 1 ft 5 in 1 ft 5 in None None 2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N 18.4 ft' "1 ft 5 in 1 ft 5 in None None 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N 18.4 ft2 1 ft 5 in 1 ft 5 in None None 4 W=>E 7. Metal Low-E Single Yes 1.03 0.27 N: 40.0'ft2 12 ft 0 in 1 ft 5 in None None 5. S=>N 8, Metal Low=E Single Yes 1.02. 0.29 N 6.9 ft' 1 ft 5 in 1 ft 5 in None. None 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N- 12.8 ft2 1 ft 5 in 1 ft 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall'Perimeter Avg,Wall Height Exposed Wall.lnsulation 1 280 ft2 280 ft2 35 ft 8.1 ft 11 INFILTRATION . # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000257 881.4 48.38 90.99 .0896 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric'HeatPump/ Split Singl HSPF:8.2 27,kBtuihr 11 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air-Flow. SHR Block Ducts 1 Central Unit/ Split Sing[ SEER:14 29 kBtu/hr cfm 0.8 1 sys#1 4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location' EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS j ---Supply-- ----Return-- . Air CFM 25 CFM25 . HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 120 ft- Attic 45 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programsble Thermostat:N Ceiling Fans: CoolingHJan Feb Mar Apr Ma Jun Jul Au Se Oct Nov Mee Heatin Jan Feb Mar f Apr f Ma 4 Jun Jul 4 Aug f Sep f Oct Nov ec Ventin Jan Feb Mar [X]A r- [ Ma [ Jun Jul [ Au [ Se [X]Oct Nov ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM -78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78, 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68. , 68 68 68 68 68 68 PM 6B 68 68 68 68 68 68 68 68 68 68 .68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 .68 PM 68 68 68 68 68 68, 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz 'Oft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ftZ ft 0.3 DEN Default(81bs/sq.ft. ftz ft 0.3 SINK AREA Default(6 Ibs/sq.ft. ftZ ft 0.3 CLOSET Default(8 Ibs/sq.ft. ftz ft 0.3 GREAT ROOM Default(8lbs/sq.ft. ftz ft -0.3 MASTER BATH Default(B lbs/sq.ft, ftz ft. 0.3 POWDER. Default(8 lbs/sq.ft. ftZ #t 0.3 KITCHEN Default(8 lbs/sq.ft. ft? ft 0.3 LAUNDRY Default(8 Ibs/s .ft.- 0 ft2 0 ft 0.3 STORAGE' 4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software. Page 5 of 5 3 2017 -AIR BARRIER.AND INSULATION INSPECTION COMPONENT CRITERIA TABLE.402.4.1.1 AIR BARRIER AND INSULATION-INSPECTION COMPONENT CRITERIA Project Name: _ WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit,Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: S Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA. General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed: Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The y pp g insulation in an dropped ceiling/soffit /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access.openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed -walls-shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing Y cavit insulation shall be installed to (including. insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to. exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,.or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring . Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior wails,or insulation that on installation-readily conforms to available space shall extend behind pipwng and wirung.' Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs_shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be.installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers.shall only be sprinklers sealed in a manner that is recommended by the manufacturer. . Caulking or other adhesive sealants shall not be used to fill voids 'Over lates and walls or epil a.In addition,inspection walls.shall be.in accord of Iog: ance with the provisions of ICC-400 4/28/2020 2:18 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1 i 2017 EPL DISPLAY CARD ' ENERGY PERFORMANCELEVEL.(EPL):DIS .PLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*_.92 The lower the Energy.Performance Index,.the,more efficient the home. .1.New home or,addition 1. New(From Plans) 12. Ducts,location&insulation level a)Supply ducts R : 6.0 2:Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Attic 3. No.of units(if multiple-family) 3. 1 4:Number of bedrooms 4. 1 13.Cooling system: Capacity 29.0 a).Split system.. SEER 14.0.. , 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER. c)Ground/water source SEER/COP 6.Conditioned floor area•(sq.ft.) 6. 1306 d)Room unit/PTAC• EER e)Other 7.Windows,type and area a)U-factor(weighted average). 7a. 0.543 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.250 14;Heating system: Capacity 27.0- c)Area 7c. 128.9 a)Split system heat pump ..HSPF• 8.2 �- b)Single'package'heat'pump.HSPF 8.Skylights -c)Electric resistance: COP a)U=factor:(weighted.average)- 8a. NA d)Gas furnace,natural gas AFUE - ,b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace,.LPG AFUE fl Other 9. Floor type,insulation level`. _a)Slab-on=grade'(R-value) 96. -0.0 b)Wood, raised(R-val'ue) • 9b. 15:Water heating system c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.60 b)Gas fired,natural gas EF 10.Wall type and insulation: c)Gas fired,LPG EF A:Exterior: d)Solarsystem with tank EF I.Wood frame.(Insulation R-value) 10A1. e)Dedicated heat pump with.tank. EF 2.Masonry,(Insulation R-Value) 1OA2. 4.1 f)Heat recovery unit HeatRec%' B.Adjacent: g);Other 1.Wood frame(Insulation:R-value) 1061. 11-0. . 2.Masonry(Insulation R-value) .1062. .16.HVAC.credits;claimed (Performance.Method) 11. Ceiling type and•insulationlevel a)Ceiling.fans a)Under attic. 11a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No.,. c)Knee walls/skylight walls 11 c. 19.0 d)Multizone cooling credit d)Radiant barrier installed_ 11d. . No e)Multizone heating credit f) Programmable-thermostat No , *Label required by Section R303.1.3 of the Florida,Building•Cod% Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code,Energy Conservation,through the above energy saving features which will be installed(or exceeded):in this home before final inspection.Otherwise,.a new EPL ' display card will be-completed,based'on installed code compliant-features. \ Builder Signature: ' Date: � a � Address of New Home: THE COTTAGE-SU'>�>4'S\`5 City/FL"Zip:. FT.PIERCE:FL 4/28/2020 2:21:49 PM EnergyGaugeO USA 6:0.04(Rev.1)-FlaRes2017,FBC 6th Edition(2017)Compliant Software Page 1 of 1