Loading...
HomeMy WebLinkAboutFL10674 DURATION1 /20/2021 Business • Professional R ulation BCIs Nome I Log In User Registration ! Hot Topics �f ride i O F! �?FRE SeCRE tt Product Approval quo USER: Public User Florida Building Code Online {` .' . Submit Surcharge Stats & Facts 1 Publications contact Us WIS Ste Map Links Search Product Approval Menu > Pr duct or ApPlicetion Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory FL10674-R16 Revision 2020 Pending FBC Approval Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscarning.com Greg Keeler greg, keeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel. sancrant@owenscornig,com Roofing Asphalt Shingles FL io(o-ctf o14 Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R16 COI 2020 Ol CDI NIEMINEN p_dfi Referenced Standard and Year (of Standard) Standar Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2019 Equivalence of Product Standards Certified By Sections from the Code httpsa/floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEAIPOjcKTwWbw%3d%3d 1/2 1 /2012021 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 12/11/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Summar of Products FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing Shingles and Starters Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section S. 3-tab, 4-tab, laminated, starter and hip & ridge shingles Installation Instructions FL10674 R16 II 202 20 12 11 FINAL ER OC ASPHALT SINGLES FL10674-1116 pdf Verified By: Robert J. M. Nieminen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL10 74 RIG AE 2020 12 11 FINAL ER QQ q pH 81 SHINGLES FL10.�_74-1116,pdf Created by Independent Third Party: Yes t' k Nezt Contact Us :: 2601 Blair Sto a Road Tallahassee FI. 3 399 Phone: 850,-487-1824 The State of Florida is an AA/EEO employer. Copyr{9ht �007-2013 State of Flprida :: LaYaM Statement :: Accessibility Statement :: R fund State ment Under Florida law, email addresses are public records. if you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional maii. If you have any questions, please contact 850.41C record *Pursuant est,t to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here. PraductApproval Accepts: ®®®ER Credit Safe 4+'Curit%'a1LTRlc's L . https:llfloridabuilding.org/ptlpr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEAIPOjcKTwWbw%3d%3d 2/2 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 ENGINEER EVALUATE TEST (203) 262-9245 CONSULT Owens Corning One Owens Corning Parkway Evaluation Report 037940.02.12-1111 Toledo, OH 43659 FL10674-1116 (740) 404-7829 Date of Issuance: 02/06/2012 SCOPE: Revision 11: 12/11/2020 This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E, for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Root Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Dumber (FL#) preceded by the words "NEMOIetc- Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. -='- '; The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 Nieminen, A.E. on 1211I12020. This does not serve as an CER TIFICATION OF INDEPENDENCE: efectronically signed document. 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. N E M 0 ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4- Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically forthat purpose. 02018 NEMO ETC, LLC ROOFING SYSTEMS EVALUATION: Type ONEMOletc. Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 71" Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section 1507.2.4, R905.2.3 Propert Physical Properties Standard Year 1507.2.5, R905.2.4 Material standard ASTM D1970 ASTM D3462 2015 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 201 6 2019 En. tlty Examination Reference Owens CorningDate PRI(TST5878) Declaration Equivalency Declaration 08/06/2019 UL LLC CER9626 ( } ASTM D1970 Physicals &Wind Resistance OCF-382-02-01 File R2453, Vol. 3 12/15/207 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 0//2007 UL LLC (TST9628) Physical Properties 06CA20263 0/1/2012 UL LLC (TST9628) Wind Resistance 11CA34308 04/18/2006 ULLLC TST9628 ( ) Physicals &Wind Resistance 4786093137 02/01/201 UL LLC (TST9628) UL LLC (TST9628) TST9628 Wind Resistance 4786126532 0201/2014 02/10/2014 UL LLC (TST9628) Physical Properties Physical Properties Classification letter 02/13/2014 PRI (QUA9110) Quality Control Classification letter Service Confirmation 10/02/2015 PRI (QUA9110) Quality Control Florida BCIS 04/05/2020 Current PRODUCT DESCRIPTION: TABLE 1: ASPHALT S Accessory Starter Strips Asphalt Shingles HINGlE C Product Plant(s) Starter Strip Shingle H-TX, OR Starter Strip Plus MN, OR 5RS TopShield Starter MN, OR Starter Shingle Roll NH Supreme" GA, CA, CO, I -TX, NJ, OH, TN, OR, IL Berkshire® MN Duration Premium CA, OR Duration®Premium COOL CA TruDefinition Duration® TruDefinition" Duration' IN, CA, CO, I -TX, FL, NJ, OH, Designer Color Collection MN, OR, GA, IL, TN Oakridge° GA, IN, CA, CO, H-TX, I -TX, FL, NJ OH, TN TrupefinitionOakridgem H-TX, 1-TX WeatherGuard° HP TN OMPONENTS Material Standard Description ASTM D3462 � starter strips for asphalt roof shingles ASTM D1970 mineral -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen starter ASTM D3462 fiberglass reinforced 3-tab asphalt roof shingles ASTM D3462 fiberglass reinforced, 4-tab asphalt roof shingles ASTM D3462 fiberglass reinforced, laminated asphalt roof shingles NEMO ETC, LLC Certificate of Authorization #32455 VH EDITION (2070) FBC NON-HVHZ EVALUATION Evaluation Report Fl10 0379400674-R11 -1116 Owens Earning Asphalt Roof Shingles Revision Il: 12/11/20201/2020 Page 2 of 10 TABLE 1: ASPHALT SHINGLE COMPONENTS ONEMO j etc. Type Product Plant(s) Material Berkshire® Hip and Ridge Standard Description Shingles with Sealant MN Hip and DuraRidgell Hip and Ridge Ridge Shingles with Sealant MN fiberglass reinforced, hip and ridge Shingles ProEdge® ASTM D3462 GA, CA, OH, OR asphalt roof shingles WeatherGuard' HP Hip and Ridge Shingles TN 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 1_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Supreme® Berkshire' Duration ° Premium Duration* Premium COOL TruDefinition® Duration® ASTM D3161(F) & ASTM D7158(H) TruDefinition° Duration' Designer Color Collection Oakridge' TruDefinition®Oakridge° WeatherGuard' HP 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC, LLC Evaluation Report 037940.02.12-1111 Certificate of Authorizorion #32455 7.. EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/202D Page 3 of 10 Starter Strips Hip & Ridge Shingles ONEMOIetc. TABLE 2113: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE Product Starter Strip Shingle Starter —strip Plus SRS TopShield Starter Berkshire' Hip and Ridge Shingles with Sealant DuraRidgeO Hip and Ridge Shingles with Sealant ProEdgeO WeatherGuard® HP Hip and Ridge Shingles FBC Table 2507.2.7.2 or R905.2.6.1 ASTM D3161, Class F ASTM D3161, Class F 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS; 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Felt underlayment Deck Sel6adhered WeatherLocr underlayment Drip Orip edge Naffs located 2'-r from ears Install rust Starter Self-sealing adhesive shinglewith ith positioned along save 6" removed Starter Strip shingle overhangs eaves and rakes tar -%" Figure 1: Minimum Nailing, Starter Strip P- - - .......... ............6, -a.— �Ll rI. rius NEMO ETC, LLC Evaluation Report 037940.02.12-R11 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 4 of 10 IR 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instrNEMO i etc, Deck Underlayment Drip edge Drip edge Starter Shingle Roll adhered directly to underlayment and primed drip edge rSe�lf�-Seahngesivepneaong eaves Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire" shingles require minimum five (5) nails per shingle. ➢ WeatherGuard° HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Normal Mansard or Area pare Wind Areas Nigh VWnd desvenes y Area pare vientos normales Areas vientos fuertes Y° 2° (B rz° Y° 5" Exposure Expoaici6n Figure 4: Minimum Nailing, Supreme (Standard Size) Normal Mansard or Area par& Wind Areas High Wind deavanes Area par& vientos nornwies Areas vientos fuertes Ytz {A) t r z' i61 Y2 1 5 51W Exposure Exposisidp Figure 5: Minimum Nailing, Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.02.12-Rli Certificate of Authorization d�32455 7" EDITION t2020) FBC NON-HVHZ EVALUATION FL10574-1316 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 5 of 10 6.3,1.2 BerkshireO: Sealant strip La rira de sellador Figure 6: 5-Nail Pattern, Berkshire ONEMO I etc. Sealant strip La tva de sellador 1 8 Yt" 8 W, t,. Figure 7: 6-Nail Pattern, Berkshire rtgure B: Mansard or Steep Slope Pattern, Berkshire NEMO ETC, LLC Evaluation Report 037940.82.12-R11 Certr [Cate afAuthoriration #32455 7" EDITION (2020) FBC NON-HVH2 EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 6 of 20 6.3.1.3 Collection: 9-118" 5518" ezpos.re KI 4-Nail Fastening Pattern Figure 9: Standard 4-Nail Pattern, Duration 6-Nail Fastening Pattern Figure 10. 6-Nail Pattern, Duration Fastening for Slopes Greater Than 21:12 5ureNaiIO fastening area width j Nall, typical 12" jf Four V Spots of Asphalt Roofing Cement Figure 11, Mansard or Steep Slope Pattern, Duration ONEMOjetc. sec:..:,.:--' ^----• � — - NEW ETC, LLC CertWcateofAuthorirotfon #31455 7T" EDITION (20201 FBC NON-HVHZ EVALUATION Evaluation Report 037940.02.12-1111 Owens Corning Asphalt Roof Shingles FL10674-RIG Revision 11; 12/11/2020 Page 7 of 10 6.3.1.4 TruDefinition®Oakrid eOOakrid ell: 4 Nail Pattern Fsquema con 4 clavos 1" y, 65/8" Exposure Nails 5 5f8" Exposure FxpaskFnhde58/8pufg. Clavas Exposlcicare6GYepulg. Figure 12: Standard 4-Nail Patten, Oakridge 5.518" 6.3.1.5 WeatherGuard® HP: IRNEMOjetc. 6 Nail Pattern Esquema con 6 davos 1" 5 518" Exposure Nails Exposiarin the § 518 ping. Clam 1-4— 1.?- 5 51e" Exposure r Exposleiun de 6518pulg. Figure 13: 6-Nail Pattern, Oakridge Fastening for Slopes Greater Than 21:12 SureNail® fastening area w€dth Nail. Typical 12" 1 F 12" Four 1" Spats ofASphart Roofing Cement Il1m I 6 Nail Pattem Esquema can 6 clavos [doll 6 1/8" from 6otlom of shingle 5 5l8" Exposure B Fasteners eve a 6 1li3 p1�u. de le Enposicilin to 5 5lB pulp. 6 S> etwores a irtfaiar de to raja 12* troll 1" lido iP k • I2�il • • • • Ttpl} w a&% F] r 5 $' 5 54' E,rs" Four 11' pots fA*mk hoof Cen-ant iipoaab;n de1558 puy &paaci5n 9e 5 rry�y. Cuatro pan Jos de cemerftode fe6o do asfafto o{ 1 pulgada Figure 15: 6-Nail Pattern, WeatherGuard HP Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP NEW ETC, LLC Evaluation Report 037940.02.12-R11 Certificate of Authnrizafion #32455 7m EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 8 of 20 6.4 HIP AND RIDGE SHINGLES: ONEMOjetc. 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire" Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require minimum two (2) nails per shingle. ➢ WeatherGuard® HP Hip and Ridge Shingles and ProEdge" require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire" Hip and Ride with Sealant and QuraffidggeO M12 and Ridge Shingles with S ea ! Fig A 4_ Prevailing Wind Direction Direcciun del viento predominante Nails F Clavos �4 I f I I 9 A I i I i i I I I I i i W W FsPosvre1 deBW A suit: L•; ibometric view, Berkshire and DuraRidge 6.4.1.2 WeatherGuard® HP Hi and Ridge Shingles: Fig. A q Prevlreclb'1'ngn Wind D A Nails 44 I � � I I I I � I i I � A I I I I � ', W Exposure -s--= =z• �o�rnrcnc view, weatnerGuard HP Hip and Ridge Fig. B Top View Vista s<tperior �i ;I" Nail 2%1 T Claw • Owens Coming SireNail ` • I I I� d l V ,z UJ� I I t eZn •6-4= — rian view, oerxsnire and DuraRidge Fig. C Hip & Ridge Shingle Fastening Top View "NaILIN T' 1214 Figure 20: Plan View, WeatherGuard HP Hip and Ridge NEMO ETC, LLC Evaluation Report 037940.02.12-R31 Certificate ojAuthorization #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 9 of 10 6.4.1.3 ProEdlze®; Prevailing Wind Direction Sealant Strip i""— 6" Exposure Fasten 7'h" Cover Exposed Fasteners with Roof Cament Figure 21: Isometric View, ProEdge fONEMOjetc. Standard Fastening Pattern j1r 2, 12" i Sealant 6„ Expo I ice• —12° figure 22: Plan View, ProEdge As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. PRI Construction Materials Technologies, LLC— QUA9110 ; Lqj3j 621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 037940.02.12-1111 Certificate ofAuthorizotion #32455 7' EDITION (2020) FSC NON-HVHZ EVALUATION Fl10674-R16 Owens Corning Asphalt Roof Shingles Revision 31: 12/11/2020 Page 10 of 10