Loading...
HomeMy WebLinkAboutInsulation Cert 7 INSULATION INSTALLATION CERTIFICATE T4: Phoenix Companies LOT BLOCK: SECTION: JOB#:110895 JOB NAME: Burke Res JOB ADDRESS: 8016 S Ocean Drive The undersigned hereby certifies that insulation has been installed at the above described property as' follows: 1. Exterior CBS walls have been insulated with............................Check one ( )Spray on cellulose to a thickness of N/A inches,which thickness,according to the ( )Fiberglass blankets manufacturer, FiFoil ()Q Aluminum Foil Density N/A will yield an"R"value of 4.1 ( ) Rioid Exterior Frame walls have been insulated with............................Check one ( )Spray on cellulose to a thickness of inches,which thickness,according to the ( )Fiberglass blankets manufacturer, ( )Aluminum Foil Density N/A will yield an"R"value of (,)Other Spray Foam 2. Main Ceilings have been insulated with.........................Check one ( )Fiberglass blankets to a thickness of 5.25 inches which thickness,according to the O Fiberglass loose fill manufacturer,. SES Sucraseal ( )Aluminum Foil Density N/A will yield an"R"value of 20 00 Spray Foam Ceilings cathedral have been insulated with.........................Check one O Fiberglass blankets to a thickness of inches;which thickness,according to the O Fiberglass loose fill manufacturer, ( )Aluminum Foil Density N/A will yield an"R"value of O Other Cellulose 3. Interior knee walls have been insulated with.................................Check one ( )Fiberglass blankets to a thickness of 5.25 inches,which thickness,according to the { )Polyurethane manufacturer, SES Sucraseal ( )Spray on cellulose Density N/A will yield an"R"value of 20 00 Other Spray Foam 4. Garage partition walls of conditioned living areas have been insulated with.... ....... . Cleel oae 0()Fiberglass blankets to a thickness of3.5 &6.25inches,which thickness,according to the ( )Spray on cellulose manufacturer, Certainteed ( )Polyurethane Density N/A will.yield an"R"value of 13 & 19 ( )Other Aluminum Foil MULTI FAMILY RESIDENTIAL CONSTRUCTION. ONLY: The common (party) walls separating different tenants shall be insulated as follows-Frame/Metal stud walls R-I I (Min.);CBS or Concrete walls R-3(Min.);by Energy Code requirements. See Energy Code Rev.1187,paragraph 903.2(b),on page 9-17, latest edition. These"minimums levels of insulation"are not included in the Energy Calculations,but shall be installed in the field: NOTE: Densities of sprayed on, loose fill,or any other composed-on site insulation shall be the P.C.F. (lb/ft3)average of three(3)"DRY SAMPLES"of actual installation. MER Enterprises,LLC Insulation Contrµ to yy Insulation Contractor Signature MCIN6231 8/16/18 Insulation Contractor's CC# Date of Certification r N Builder's Name-Builder's CC# �Pe b tc G n, "n z O CD r- LP —n r �