Loading...
HomeMy WebLinkAboutAPPROVED X 1 OF 13 STEEL BUILDINGSEE PLAN DUT TO OUT CONCRETE 2 _ SEE PLAN _ OUT TO OUT STEEL W W PROJECTION CONCRETE EDGE AND ANCHOR BOLT PROJECTION WALL PANEL 112 x t 1/4' SDS INSIDE CLOSURE W/VASHER (6' OG) BASE ANGLE \ 2'x4'xl6GA r ,• 1/4' x'I' I STD. BASE TRIM - + NAIL-IM ANCHOR IDTR) ! 36' OZ MY TITHER.' BASE ANGLE WITH BASE TRIM AND BASE CLOSURES VITHOUT SHEETING NOTCH CONCRETE EDGE AND ANCHOR BOLT PROJECTIO AT SLAB WITHOUT NOTCH SLAB BEYON FINISHED FLOOR JANS DEPTH SECTION 'A -A' 1-314' FOWIDT I3l4' 'A-AW a a y o a 0 TYR OVERHEAD DOOR RECESS DETAIL ANCHOR BOLTS NOTES MANUFACTURER RECOMMENDS USE OF STRAIGHT ROD ANCHOR BOLTS w/FLAr WASHt li WITH NUT AND WASHER ON BOTH ENDS AS OPPOSED TO J-BOLTS CONCRETE LINE OR ANCHOR BOLTS WITH HOOKS BECAUSE OF BETTER PERFORMANCE RESULTS IN CONCRETE FOUNDATIONS. THE TYPE OF BOLT USED FOR THE PROJECT SHALL BE DETERMINED BY THE FOUNDATION ENGINEER WITH THE BOLT STRENGTH MEETING OR EXCEEDING THAT OF AN ASTM F1554 GRADE 36 (MIN.) BOLT. ANCHOR BOLTS ANCHOR BOLT SUMMARY SEE BUILDING PLANS FOR PROJECTION Dia Proj \ Qty Locate (in) Type (in) 0 48 Jamb 5/8" F1554 3.00 Z 9 40 Endwall 3/4" F1554 3.00 � TOTAL LENGTH DETERMINED 9156 X 136 Frame Frame 3/4" 1 F1554 F1554 3.00 4.00 BY FOUNDATION ENGINEER •• 0 ANCHOR BOLTS SHALL BE ASTM F1554 GRADE 36 MIN. OR GRADE 55 M (27134-1) 27134-2) VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY N v ADEL, GA 31620 KEY PLAN ANCHOR BOLT PLAN tkt�ttttttslr�hr*rr+r `k�SSh L r+ NOTE: All Base Plates 0 100'-0" (U.N.) �$ q •� ENS." '•s /•''��..•;y` l=k = 1 —3/4" Y . No. 83970 yy if STATE OF ' OR ylrltrl�I/H•YN ORIGINAL SIGNATURE REQU ED REVISIONS DRAWING STATUS C I FINAL ERECTION CXl F-OR CONSTRUCTION C I FOR APPROVAL C I NOT CONSTRUCTION VULCAN STEEL STRUCTURES, INC RK DAVIS CONSTRUCTION CORP, REV. DESCRIPTION, DATE DTLR DATE CHKR APPD PROJECT MAVERICK BOATS ANCHOR BOLT PLAN ID 0134-3 DESIGN1 VLB I DRAFT, vb CHECKi JDR PROJECT ADDRESS FORT PIERCE, FL 34946 DATE13/25/21 SHEET 1 OF 13 3/4" W 0 1 "-0 1 4" I N I f81 Im u 0 .0- �I DETAIL A Dia= :3/4" 0 1 -0 1 2" a ( NrTy — SBJ f L i81 W cq m - DETAIL B !A N O IE e m d � �I DETAIL C Dia= 3/4" all —li 4" wj 2" 2," L 1- 4 - DETAIL D Oki= 3/4•" 4" 1I III 1I� 4" 2" FTI 2" $.. See Plan DETAIL E Dia= 3/4" all N I ' im1m 4" o �I� I� 4- 2- � 2" 8" See Plan Al F = 3/4" MIDI 4" 4" 2" ►"+ 2" B" I —4 DETAIL G Dia= 5/8" 0 d9,1 r� ;•� � ro o � M z SW N � DETAIL H Dia= 5/8" Dia= 1" r-3 y101, . I I 9 �+ I' 4 1/4"w = XIX toI o 4., o X f X 4" ILA 2.. SW — SW m 1 3/4" 2" 2'" See Plan See Plan See Plan DETAIL N DETAIL M rh 101. . I I a XI X 3." N 0 1 4„ X X m SW 2" 2" rn See Plan Seela DETAIL J Dia= 1" 10.1 I 5 1 /8" XX tn N 4" XIX 0. m SW 2" 2" See Pan See Plan DETAIL K Dig- 1 ca a. m X�X 4" o I IX 4" X _I_ 4" c 2" See PlaT2'. ee elan DETAIL L EVISIQNS RLV. DESCRIPTION+ Dia= 3/4" _I 3,� 2„ ,k l2." 8" DETAIL A3 Dia= 3/4" 8„ o 3 ". 2"2" 8" See Plan DETAIL B3 y {27//1//34/—//}�(27134-2)� N KEY PLAN i]98W1Nf1 'SIA1f_1S I I FINAL ERECTION EX] FOR CONSTRUCTION I I FOR APPROVAL I I NOT CONSTRUCTION VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 +i�•i■IIYfN 4riH � I H Illllp ,,• ESSA C. QA No.83970 STATE OF 10 NAL EN S`.•`. '+•. /��ilixlliliYililY*1 f ORIGINAL SIGNATURE REQUIRED VULCAN STEEL STRUCTURES, INC RK DAVIS CONSTRUCTION CORP. PROJECT MAVERICK B13ATS ANCHOR BOLT DETAILS ?D 27134-3 DESIGN, VLB DRAFT, vlo I CHECK, JDR PROJECT FORT PIERCE, FL 34946 DATE13/17/21 SHEET 2 OF 13 ADDRESS 1 2 3 4 ITr, - COLUMN LINE IV RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in Elev. ) Lin e ne Qty Dia Width Length hick (in) E* 36 4 0.750 8.000 10.00 0.500 0.0 E* Frame lines: E A RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in) Elev. Line Line Qty Rio Width Length Thick (in) C* 36 4 0.750 8.000 10.00 0.500 0.0 C* Frame lines: C B DESIGN LOAD DEFINITIONS RIGID FRAME: BASIC COLUMN REACTIONS (k ) Frame Column -----Dead-----Collateral- ----- Uve------ Wind-Leftl- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert E* 36 0.0 0.7 0.0 0.9 -0.3 4.0 1.2 -14.4 C* 36 -0.1 1.1 0.0 1.6 -0.7 6.2 2.1 -23.9 Frame Column-Wind_Right2---Wind_Longl---Wind_Long2- Une Line Horiz Vert Horiz Vert Horiz Vert E* 36 0.4 -0.6 -0.2 -9.6 -0.2 -6.8 C* 36 0.7 0.1 -0.4 -15.6 -0.3 -11.7 E* Frame lines: E A C* Frame lines: C B BUILDING BRACING REACTIONS t Reactions(k ) Panel Shear -Wall - Col -Wind - -Seismic- (lb7ft) Loc Line Line Harz Vert Harz Vert Wind Seis Note LEW E (fh F-SW 35 R-EW A h B-SW 36 Torsional Bracing Used f)Bracing loads are applied to adjacent building h)Rigid frame at endwall RIGID FRAME LOAD CASE DEFINITIONS Wlnd_Ll/Wlnd_RI = Lateral wind load from the left/right with a negative Internal pressure coefficient. Wind_L2/Wlnd_R2 = Lateral wind load from the left/right with a positive Internal pressure coefficient. Wlnd_Lnl = Longitudinal wind load with a negative Internal pressure coefficient. Wind_Ln2 = Longitudinal wind load with a positive Internal pressure coefficient, Selsmlc_L/Selsmlc_R = Lateral Seismic load from left/right. LWIND#_L#E/ LWIND#_R#E = Longitudinal wind loads for edge zones, F#UNB_SL_L/ F#UNB_SL_R = Unbalanced roof snow load with wind from the left/right. F#PAT_LL # = Pattern live load for continuous beam systems. 'Note, Bracing reactions are not already Included In combination with any other load but must be added to basic reactions as desired by the foundation designer.' Collat = Collateral Load Endwall Load Case Deflnitlons Rafter Wlnd_L/ Rafter Wlnd_R = Lateral wind load from the left/right, Brace Wlnd_L/ Brace Wlnd_R = Lateral wind load from the left/right with the bracing loads added, Wlnd_P/Wlnd_S = Wind Pressure/Suction due to longitudinal wind. Wlnd_Ln# = Longitudinal wind load on the roof, Selsmlc_L/Selsmlc_R = Lateral Seismic load from left/right, E#UNB_SL_L/ E#UNB_SL_R = Unbalanced roof snow load with wind from the left/right, fE#PAT_LL # = Pattern live load for continuous beam systems, LWIND#_L/LWIND#_R = Longitudinal wind loads for edge zones. REVISIONS -Wind-Rightl- --Wind-Left2- Horiz Vert Horiz Vert 0.3 -8.1 1.4 -6.9 0.4 -13.8 2.4 -10.0 GENERAL NOTES (1.) APPLICATION OF ENGINEERS SEAL IS FOR METAL BUILDING ONLY AND DOES NOT REPRESENT THE PROFESSIONAL OF RECORD. (2. FOUNDATION DESIGN AND CONSTRUCTION ARE NOT THE RESPONSIBILITY OF THE M AL BUILDING MANUFACTURER. (3.) ANCHOR BOLTS SHALL BE ACCURATELY SET TO A TOLERANCE OF +/- 1/8" IN BOTH ELEVATION AND LOCATION. 4.) THE BUILDING REACTION DATA REPORTS THE LOADS WHICH THIS BUILDING PLACES N THE FOUNDATION. THE FOUNDATION IS TO BE DESIGNED BY A QUALIFIED ENGINEER TO SUPPORT THE BUILDING REACTIONS IN ADDITION TO OTHER LOADS IMPOSED BY THE BUILDING USE OR OCCUPANCY WITH RESPECT TO JOB SITE CONDITIONS. (5.) ALL ANCHOR BOLTS TO BE ASTM F1554 GRADE 36 MIN. OR GRADE 55 (UNLESS NOTED) kVALUES GIVEN FOR BENDS AND ANCHOR BOLT TOTAL LENGTHS ARE SUGESTED LENGTHS Y. IT IS THE RESPONSIBILITY OF THE FOUNDATION ENGINEER TO DETERMINE THESE VALUES SINCE THEY ARE A FUNCTION OF CONCRETE STRENGTH AS WELL AS OTHER FACTORS. (7.) WIND REACTIONS ARE BASED ON Vult. E I FINAL ERECTION [XI FOR C❑NSTRUCTI❑N I I FOR APPROVAL I I OTHER, EXPLAIN VULCAN STEEL STRUCTURES, INC ID 27134-3 PROJECT IFORT PIERCE, FL 34946 ADDRESS VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 a`!a!la11!!!i!!I!1lpr�rfr aa'a�a ca A L. �•'���i No. S3 - ' STATE OF c V NAL ORIGINAL SIGNATURE REQUIRED RK DAVIS CONSTRUCTION CORP, ANCHOR BOLT DETAILS IL REACTIONS DESIGNi VLH I DRAFTi vb CHECKi JDR DATE,3/27/21 I SHEET 3