Loading...
HomeMy WebLinkAboutAvalon Custom HVAC LT 20 MANUAL J & MAN. D DUCT SUMMARY[62]Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 1 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Load Short Form 01/06/2020Date:ENTIRE BUILDING CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor: Avalon by the Beach Lot 20, St Lucie County, FL 34949 Design Information InfiltrationClgHtg SimplifiedMethod9143Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1627Design TD (°F) L-Daily range 5050Inside humidity (%) 5922Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) 1st Flr AHU 1521 25358 23716 368 1000 2nd Flr AHU 1139 20677 20755 231 1000 ENTIRE BUILDING 2659 46035 44471 599 2000 Other equip loads 0 0 Equip. @ 1.00 RSM 44471 Latent cooling 8387 TOTALS 2659 46035 52858 599 2000 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 2 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Load Short Form 01/06/2020Date:1st Flr AHU CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor: Avalon by the Beach Lot 20, St Lucie County, FL 34949 Design Information InfiltrationClgHtg SimplifiedMethod9143Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1627Design TD (°F) L-Daily range 5050Inside humidity (%) 5922Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Trane Make Trane Trade Trade TRANE Model Cond 4TTR6030J1 AHRI ref Coil TEM6A0B30H21++TDR AHRI ref 8626669 Efficiency 100 EFF Efficiency 14.0 EER, 16.5 SEER Heating input kW7.7 Sensible cooling Btuh25112 Heating output Btuh26273 Latent cooling Btuh4088 Temperature rise °F65 Total cooling Btuh29200 Actual air flow cfm368 Actual air flow cfm1000 Air flow factor cfm/Btuh0.015 Air flow factor cfm/Btuh0.042 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.86 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Dining 120 4798 4264 70 180 Master Bdrm 330 7066 6200 103 261 Master WIC 57 893 403 13 17 Kitchen 268 643 2179 9 92 Master Bath 117 1352 1999 20 84 WC Rm 15 0 0 0 0 Laundry 55 1457 1767 21 74 G Hall 23 0 0 0 0 Foyer 150 2486 1216 36 51 Study 222 5356 4713 78 199 Bath 4 84 1307 975 19 41 1st flr stairs 79 0 0 0 0 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 3 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 1st Flr AHU 1521 25358 23716 368 1000 Other equip loads 0 0 Equip. @ 1.00 RSM 23716 Latent cooling 3729 TOTALS 1521 25358 27445 368 1000 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 4 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Load Short Form 01/06/2020Date:2nd Flr AHU CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor: Avalon by the Beach Lot 20, St Lucie County, FL 34949 Design Information InfiltrationClgHtg SimplifiedMethod9143Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1627Design TD (°F) L-Daily range 5050Inside humidity (%) 5922Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Trane Make Trane Trade Trade TRANE Model Cond 4TTR6030J1 AHRI ref Coil TEM6A0B30H21++TDR AHRI ref 8626669 Efficiency 100 EFF Efficiency 14.0 EER, 16.5 SEER Heating input kW7.7 Sensible cooling Btuh24236 Heating output Btuh26273 Latent cooling Btuh4964 Temperature rise °F104 Total cooling Btuh29200 Actual air flow cfm231 Actual air flow cfm1000 Air flow factor cfm/Btuh0.011 Air flow factor cfm/Btuh0.048 Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.82 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Bedrm 3 WIC 48 786 558 9 27 2nd Flr Stairs 79 0 0 0 0 Loft 247 3358 3238 38 156 2nd flr hall 49 0 0 0 0 Bath 3 47 590 701 7 34 Bath 2 54 597 708 7 34 Bedroom 2 209 2525 2963 28 143 Bedroom 3 150 2616 2320 29 112 Family 256 4386 5264 49 254 KITCHEN CLG.0 5820 5003 65 241 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 5 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 2nd Flr AHU 1139 20677 20755 231 1000 Other equip loads 0 1195 Equip. @ 1.00 RSM 21949 Latent cooling 4658 TOTALS 1139 20677 26607 231 1000 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 1 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Building Analysis 01/06/2020Date:ENTIRE BUILDING CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor: Avalon by the Beach Lot 20, St Lucie County, FL 34949 Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)Vero Beach Muni, FL, US 1627Design TD (°F)ft30Elevation: 5050Relative humidity (%)°N28Latitude: Outdoor:59.422.0Moisture difference (gr/lb)CoolingHeating Infiltration:9143Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality78-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing OtherCeilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 17.882092.6Walls 35.81650327.9Glazing 1.254913.4Doors 7.032441.5Ceilings 13.562352.92.9Floors 13.662701.8Infiltration 10.95025Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.046035Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains % of loadBtuhBtuh/ft²Component 15.368242.2Walls 45.72032034.3Glazing 1.359614.6Doors 7.231911.5Ceilings 0.31200.1Floors 4.118440.5Infiltration 7.63366Ducts 00Ventilation 18.58210Internal gains 00Blower 0Adjustments 100.044471Total Latent Cooling Load = 8387 Btuh Overall U-value = 0.254 Btuh/ft²-°F ERROR: negative wall area in Bedroom 3 - check windows. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 2 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Building Analysis 01/06/2020Date:1st Flr AHU CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor: Avalon by the Beach Lot 20, St Lucie County, FL 34949 Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)Vero Beach Muni, FL, US 1627Design TD (°F)ft30Elevation: 5050Relative humidity (%)°N28Latitude: Outdoor:59.422.0Moisture difference (gr/lb)CoolingHeating Infiltration:9143Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality78-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing DoorsCeilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 18.145972.8Walls 31.2791927.9Glazing 2.254913.4Doors 4.912321.5Ceilings 20.752473.53.5Floors 11.529051.8Infiltration 11.52908Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.025358Total Cooling Walls Glazing Doors Ceilings Infiltration Ducts Internal Gains % of loadBtuhBtuh/ft²Component 16.037982.3Walls 43.71036536.5Glazing 2.559614.6Doors 5.112131.5Ceilings 000Floors 3.68540.5Infiltration 7.71830Ducts 00Ventilation 21.35060Internal gains 00Blower 0Adjustments 100.023716Total Latent Cooling Load = 3729 Btuh Overall U-value = 0.235 Btuh/ft²-°F Data entries checked. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 3 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Building Analysis 01/06/2020Date:2nd Flr AHU CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor: Avalon by the Beach Lot 20, St Lucie County, FL 34949 Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)Vero Beach Muni, FL, US 1627Design TD (°F)ft30Elevation: 5050Relative humidity (%)°N28Latitude: Outdoor:59.422.0Moisture difference (gr/lb)CoolingHeating Infiltration:9143Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality78-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Ceilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 17.536122.4Walls 41.5858427.8Glazing 000Doors 9.720121.5Ceilings 4.89881.61.6Floors 16.333641.8Infiltration 10.22117Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.020677Total Cooling Walls Glazing Ceilings OtherInfiltration Ducts Internal Gains Blower % of loadBtuhBtuh/ft²Component 13.830262.0Walls 45.4995532.3Glazing 000Doors 9.019791.5Ceilings 0.51200.2Floors 4.59890.5Infiltration 7.01536Ducts 00Ventilation 14.43150Internal gains 5.41195Blower 0Adjustments 100.021949Total Latent Cooling Load = 4658 Btuh Overall U-value = 0.275 Btuh/ft²-°F WARNING: window to floor area ratio = 27.1% - more than 25%. ERROR: negative wall area in 2nd Flr Stairs - check windows. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 1 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Project Summary 01/06/2020Date:ENTIRE BUILDING CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor:Avalon by the Beach Lot 20, St Lucie County, FL 34949 Notes: Design Information Vero Beach Muni, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91Inside db °F70 Inside db °F75 Design TD °F27 Design TD °F16Daily range L Relative humidity %50Moisture difference gr/lb59 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh41010 Structure Btuh41105 Ducts Btuh5025 Ducts Btuh3366Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 Humidification Btuh0Blower Btuh0 Piping Btuh0Equipment load Btuh46035 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh44471 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh5765 Ducts Btuh2622Central vent (0 cfm) Btuh0 CoolingHeating26592659Area (ft²) Equipment latent load Btuh8387 3092630926Volume (ft³)Air changes/hour 0.210.41 Equipment Total Load (Sen+Lat)Btuh52858 Equiv. AVF (cfm) 108211 Req. total capacity at 0.70 SHR ton5.3 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTrade n/a Trade n/a Model n/a Cond n/aAHRI ref n/a Coil n/a AHRI ref n/aEfficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 2 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Project Summary 01/06/2020Date:1st Flr AHU CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor:Avalon by the Beach Lot 20, St Lucie County, FL 34949 Notes: Design Information Vero Beach Muni, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91Inside db °F70 Inside db °F75 Design TD °F27 Design TD °F16Daily range L Relative humidity %50Moisture difference gr/lb59 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh22449 Structure Btuh21886 Ducts Btuh2908 Ducts Btuh1830Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0Blower Btuh0 Piping Btuh0Equipment load Btuh25358 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh23716 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2422 Ducts Btuh1306Central vent (0 cfm) Btuh0 CoolingHeating (none)15211521Area (ft²) Equipment latent load Btuh3729 1520515205Volume (ft³)Air changes/hour 0.200.39 Equipment Total Load (Sen+Lat)Btuh27445 Equiv. AVF (cfm) 5098 Req. total capacity at 0.86 SHR ton2.3 Heating Equipment Summary Cooling Equipment Summary Make Trane Make TraneTrade Trade TRANE Model Cond 4TTR6030J1AHRI ref Coil TEM6A0B30H21++TDR AHRI ref 8626669Efficiency 100 EFF Efficiency 14.0 EER, 16.5 SEER Heating input kW7.7 Sensible cooling Btuh25112Heating output Btuh26273 Latent cooling Btuh4088 Temperature rise °F65 Total cooling Btuh29200Actual air flow cfm368 Actual air flow cfm1000 Air flow factor cfm/Btuh0.015 Air flow factor cfm/Btuh0.042Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.86 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 3 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Project Summary 01/06/2020Date:2nd Flr AHU CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor:Avalon by the Beach Lot 20, St Lucie County, FL 34949 Notes: Design Information Vero Beach Muni, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91Inside db °F70 Inside db °F75 Design TD °F27 Design TD °F16Daily range L Relative humidity %50Moisture difference gr/lb59 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh18561 Structure Btuh19219 Ducts Btuh2117 Ducts Btuh1536Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0Blower Btuh1195 Piping Btuh0Equipment load Btuh20677 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh21949 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3342 Ducts Btuh1316Central vent (0 cfm) Btuh0 CoolingHeating (none)11391139Area (ft²) Equipment latent load Btuh4658 1572115721Volume (ft³)Air changes/hour 0.220.43 Equipment Total Load (Sen+Lat)Btuh26607 Equiv. AVF (cfm) 58113 Req. total capacity at 0.83 SHR ton2.2 Heating Equipment Summary Cooling Equipment Summary Make Trane Make TraneTrade Trade TRANE Model Cond 4TTR6030J1AHRI ref Coil TEM6A0B30H21++TDR AHRI ref 8626669Efficiency 100 EFF Efficiency 14.0 EER, 16.5 SEER Heating input kW7.7 Sensible cooling Btuh24236Heating output Btuh26273 Latent cooling Btuh4964 Temperature rise °F104 Total cooling Btuh29200Actual air flow cfm231 Actual air flow cfm1000 Air flow factor cfm/Btuh0.011 Air flow factor cfm/Btuh0.048Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.82 Job #: 191242 Performed by CJH for: Gelcorp. Industries Avalon by the Beach Custom Home Avalon by the Beach Lot 20 St Lucie County, FL 34949 The EARTHWORKS Group 7410 S US Hwy 1 Suite 104 Port St Lucie, FL 34952 Scale: 1 : 101 Page 1 Right-Suite® Universal 2019 19.0.21 RSU25986 2021-Mar-09 14:07:56 ...alcs EXPGUHIGU_new windows.N.rup N Level 1 Family Kitchen Dinin g Master Bdrm Master WIC Master Bath WC Rm LaundryG Hall Garage Fo yer Study Bath 4 1st flr stairs Job #: 191242 Performed by CJH for: Gelcorp. Industries Avalon by the Beach Custom Home Avalon by the Beach Lot 20 St Lucie County, FL 34949 The EARTHWORKS Group 7410 S US Hwy 1 Suite 104 Port St Lucie, FL 34952 Scale: 1 : 101 Page 2 Right-Suite® Universal 2019 19.0.21 RSU25986 2021-Mar-09 14:07:56 ...alcs EXPGUHIGU_new windows.N.rup N 2ND Flr Bedroom 3 Bedrm 3 WIC 2nd Flr Stairs Loft 2nd flr hall Bath 3 Bath 2 Bedroom 2 KITCHEN CLG. Bold/italic values have been manually overridden 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 1 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Duct System Summary 01/06/2020Date:1st Flr AHU CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor: Avalon by the Beach Lot 20, St Lucie County, FL 34949 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.21in H2O0.21 Available static pressure in H2O0.49in H2O0.49 Supply / return available pressure 0.282 / 0.208 in H2O in H2O0.282 / 0.208 Lowest friction rate in/100ft0.080in/100ft0.080 Actual air flow cfm1000cfm368 Total effective length (TEL) ft612 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st4295.041.0VlFx0x05.00.0844119975cBath 4 st3250.038.6VlFx0x09.00.098180704264cDining st4320.032.1VlFx0x06.00.08051361216cFoyer st4310.039.2VlFx0x07.00.0819292179cKitchen st3260.09.3VlFx0x06.00.10574211767cLaundry st3250.018.1VlFx0x07.00.10584201999cMaster Bath st3230.036.6VlFx0x08.00.106131513100cMaster Bdrm st3225.047.1VlFx0x08.00.104131513100cMaster Bdrm-A st3240.024.3VlFx0x04.00.1071713403cMaster WIC st4300.051.5VlFx0x010.00.080199784713cStudy Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st4 Peak AVF 142 383 0.080 552 10.6 10x10 RectFbg st1 st3 Peak AVF 226 617 0.098 617 12.2 12x12 RectFbg st1 st1 Peak AVF 368 1000 0.080 643 15.2 14x16 RectFbg 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 2 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb2 0x 1350 363 109.7 0.190 462 12.0 x0 0 VlFx rt1 rb5 0x 780 199 259.6 0.080 364 10.0 x0 0 VlFx rt4 rb4 0x 1550 439 251.5 0.083 410 14.0 x0 0 VlFx rt4 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 368 1000 0.080 571 15.2 14x18 RectFbg rt4 Peak AVF 233 637 0.080 546 12.8 12x14 RectFbg rt1 Bold/italic values have been manually overridden 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 3 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N 191242Job:Duct System Summary 01/06/2020Date:2nd Flr AHU CJHBy: The EARTHWORKS Group 7410 S US Hwy 1 Suite 104, Port St Lucie, FL 34952 Project Information Gelcorp. Industries Avalon by the Beach Custom HomeFor: Avalon by the Beach Lot 20, St Lucie County, FL 34949 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0.21in H2O0.21 Available static pressure in H2O0.29in H2O0.29 Supply / return available pressure 0.143 / 0.147 in H2O in H2O0.143 / 0.147 Lowest friction rate in/100ft0.067in/100ft0.067 Actual air flow cfm1000cfm231 Total effective length (TEL) ft430 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st2180.020.8VlFx0x05.00.071347708cBath 2 st2180.023.4VlFx0x05.00.070347701cBath 3 st2175.025.8VlFx0x04.00.071279558cBedrm 3 WIC st2180.031.4VlFx0x09.00.067143282963cBedroom 2 st2175.027.1VlFx0x08.00.071112292320cBedroom 3 st2150.030.7VlFx0x08.00.079127242632cFamily st2135.033.2VlFx0x08.00.085127242632cFamily-A st2160.027.7VlFx0x08.00.076121332502cKITCHEN CLG. st2140.035.5VlFx0x08.00.081121332502cKITCHEN CLG.-A st2175.030.2VlFx0x07.00.07078191619cLoft st2165.021.0VlFx0x07.00.07778191619cLoft-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 231 1000 0.067 643 15.7 16x14 RectFbg 2021-Mar-09 14:07:24 Right-Suite® Universal 2019 19.0.21 RSU25986 Page 4 ...n Custom HVAC calcs EXPGUHIGU_new windows.N.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb3 0x 350 177 143.5 0.103 400 9.0 x0 0 VlFx rt2 rb1 0x 380 139 218.4 0.067 314 9.0 x0 0 VlFx rt6 rb8 0x 1580 684 212.9 0.069 387 18.0 x0 0 VlFx rt6 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt2 Peak AVF 231 1000 0.067 571 15.7 14x18 RectFbg rt6 Peak AVF 196 823 0.067 590 16.0 0x0 VinlFlx rt2