Loading...
HomeMy WebLinkAboutFL17347_R4_AE_(d) Eval 17347.15FRONTDOORR W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Registry License No. 9813 Product Category Sub Category Manufacturer Product Name Plastpro Inc. Opaque Fiberglass Doors Exterior Swinging Exterior Door 5200 W. Century Blvd. Singles Doors Assemblies Los Angeles, CA w/ or w/out Sidelites Phone 440.969.9773 Inswing / Outswing - "Impact" Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for Plastpro Inc., based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code structural requirements excluding the "High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM El996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-17347.15 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-17347.15 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01390410 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V. K. Wright TEL 01390454 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V. K. Wright TEL 01391140 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V. K. Wright TEL 01391120 TAS 201, 202 & 203-94 Testing Evaluation Lab.,lnc. William B. Shelton, P.E. 2. Miami -Dade NOA Materials Testing 17-0712.05 Saflex® PVB Interlayer (Eastman Chemical Company) 3. Drawing No. Prepared by Signed & Sealed by No. FL-17347.15 RW Building Consultants, Inc. (#9813) Lyndon F. Schmidt, P.E. 4. Calculations Prepared by Signed & Sealed by Anchoring RW Building Consultants, Inc. (#9813) Lyndon F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Plastpro Inc. is manufacturing products 9 fY� 9 P 9 P within a quality assurance program that complies with ISO/IEC 17020 and+.,r(�', Guide53. '••tiGr�jS�1.�' • No 43409 �r MSS • S •! % : E ?� F .a�j'' � -"re'r F �6�f ° ���° Lyndon F. Schmidt, P.E. FL PE No. 43409 8/6/2020 Sheet 1 of 1