Loading...
HomeMy WebLinkAbout005-A1.1DIM_FL-PLAN_Lot28OPENTOBELOWLoft10'-0"Bdrm 210'-0"Bath 210'-0"Bdrm 310'-0"TUB/SHOWERBath 310'-0"TUB/SHOWERWIC10'-0"2SECOND FLOOR PLAN SCALE: 1/4" = 1' - 0"OPTION #1LINEN70'-0" 1'-0"4'-4"34'-8" 14'-2"6'-2"5'-4"9'-0" 24'-8"5'-4" 70'-0"24'-8"7'-4"14'-0"3'-4"4'-4"6'-4"14'-0"10'-0"9'-8"1'-0"42'-8"14'-0"7'-4"21'-4"1'-4"4'-8"1'-4"2'-2"5'-0"5'-0"5'-8"2'-0"8'-4"42'-8"15'-4"14'-8"12'-8"3'-8"3'-6"3'-6"16'-4"4'-0"4'-0"2'-6"1'-4"3'-0"5'-4"9'-0"1'-4"5'-6"10"5'-2"8" 11'-4"6'-6"5'-4"11'-6" 5'-8"6"5'-8" 1'-8"8"3'-6"6'-5"14'-7"8"8'-4"3'-6"3'-2"3'-0"11'-0"6"10'-4"5'-0"12'-2"8"1'-10"6"2'-8"3'-10"10'-6"8"3'-0"3'-0"8"1'-4"3'-0"5'-4"4'-2"3'-10"15'-8"8"M2M5G5G5G3G3 3060 CSMT 3060 CSMT 3060 CSMT 3020 FG 3020 FG 3060 CSMT 3060 FG 3060 FG 3060 FG 3060 FG 2020 FG 2020 FG 2020 FG 3060 FG 2060 FG 2060 FGG5G5G5 26802680 2680268026802080 (2)1880 (2)1880 B1B1DNINDICATES 1stFLOOR LINEINDICATES 1stFLOOR LINEINDICATES 1stFLOOR LINE2680 PKT9'-2"3'-0"2A4.12A3.2F5F5F5 13'-4"29'-4"CMU2X8 WOODFRAMECMU WALL2x6 WOODFRAME CMU WALL CMU WALLCMU WALL2x6 WOODFRAME 3060 CSMTOPEN TO ENTRYBELOW1'-10"2X8 WOODFRAME2X6 WOODFRAME36" LOWWALL36" LOWWALL 3A7.12A7.1INDICATES 1stFLOOR LINEINDICATES 1stFLOOR LINE TOP OF OPN'G@ 9'-0" 4'-2"4'-0"8'-8"CMU WALL3'-6"2480G55'-2"M4NOTE:WDW. SILL@ 80" ABV.LANDINGFLOOR PLAN TYPICAL NOTES:GENERAL:VERIFY FINISH FLOOR ELEVATIONS W/ LANDSCAPE, GRADING, AND DRAINAGE PLANS.ALL EXTERIOR WINDOWS & DOORS ARE DIMENSIONED TO CENTER LINE U.N.O.ALL HANDRAILS AND GUARD RAILS TO BE 36" AFF U.N.O. W/ VERTICALPICKETS/BALUSTRADES SPACED SO AS TO NOT ALLOW THE PASSAGE OF A 4"SPHERE. PROVIDE TOE RAILING AS REQ'D, MAX 2" A.F.F. COORD. FINAL MATERIAL,DESIGN, AND FINISH WITH ID/OWNER. HANDRAILS AND GUARDS MUST COMPLY WITHTHE REQUIREMENTS OF THE FBC R311.7.8 HANDRAILS (STAIRS), R311.8.3 HANDRAILS(RAMPS), R312 GUARDS.PROVIDE METAL THRESHOLD (MT) AT DOORS LEADING TO THE GARAGE, ELEVATORDOOR AND ALL EXTERIOR DOORS, TYP. U.N.O.COORDINATE ATTIC ACCESS LOCATIONS W/ FINAL TRUSS LAYOUTSEE STRUCTURAL DRAWINGS FOR ALL LOAD BEARING WALL, COLUMN AND FILLEDCELL LOCATIONS.EXTEND SLAB EDGE @ DOORS 112" TYP. BEYOND STEM WALLALL INTERIOR FACE OF DOOR JAMBS TO BE A MINIMUM OF 6" OFF ADJOINING WALLFOR TRIM, CORD .W/ ID/ OWNER, TYPICAL. U.N.OPROVIDE A 6" WALL AT ALL W.C. & VENT AT ALL WASHER & DRYER LOCATIONS. V.T.ECLOTHES DRYER SHOULD COMPLY WITH FBCR M1501VERIFY ELECTRIC AND A/C CHASE LOCATIONS W/ ELECTRICAL AND MECHANICALCONTRACTOR. COORD. W/ CABINETRY PACKAGE.VERIFY APPLIANCES W/ CABINETRY PACKAGE.FOR WALLS THAT ABUT NON-CONDITIONED SPACE USE "DENSARMOR"FOR WALLS THAT ARE IN DIRECT CONTACT WITH WET AREAS: USE"DENSARMOR PLUS"FOR WALLS AND CEILING AT A TUB/SHOWER USE CEMENT BOARD SHEATHINGW/ TILE FINISH AS SELECTED BY OWNER.FLOOR PLAN KEY NOTES:A: APPLIANCESA1WASHERA2DRYER - VENT TO EXTERIORA3REFRIG./FREEZER -SEE ID/OWNER APPLIANCE PACKAGE- VERIFY ELEC. REQ. WITHSELECTION, COORD. WITH CABINETRY CONSULTANTA448" TO 60" GAS STOVE/OVEN - FINAL SIZE TBD - w/ HOOD AND EXHAUST FAN, V.T.E.COORD. EXHAUST FAN OPENING THROUGH MASONRY WALL. VERIFY FINAL OPENINGHEIGHT AND DIAMETER WITH HOOD AND EXHAUST FAN SPECS. INSTALL PER MFR'SWRITTEN INSTRUCTIONS. COORD. W/ ID/ OWNER.OR 48" TO 60" GAS STOVE/OVEN W/ HOOD V.T.E. - KITCHEN HOOD FLUE VENT, 2" MIN.CLEARANCE TO COMBUSTIBLES, SEE MFR.'S WRITTEN INSTRUCTIONS.A5DISHWASHER- COORD. WITH CABINETRY CONSULTANT & OWNER FOR FINALLOCATION. - SEE PLUMBING NOTES, SEE ELECTRICAL KEY NOTES.A6UNDER COUNTER REFRIGERATOR-SEE ID/ OWNER APPLIANCE PACKAGE- VERIFYELEC. REQ. WITH SELECTION, COORD. WITH CABINETRY CONSULTANTA7STACK OVEN- COORD. WITH OWNER/ CABINETRY CONSULTANT FOR SINGLE ORDOUBLE OVEN.A8GAS GRILL (SIZE TBD) - PROVIDE EXHAUST HOOD. V.T.E. COORD. WITH ID/OWNER &CABINETRY CONSULTANT.A9UNDER COUNTER ICE MAKER(SIZE TBD)A10CENTRAL VACUUM SYSTEM - COORD. WITH OWNER & CONTRACTOR.B: BATH/ SHOWERNOTE: SEE ALSO, PLUMBING BELOW.PROVIDE CEMENT BOARD SHEATHING AND HYDRO BAN WATERPROOFING AT ALLTUB/SHOWER AND WET AREAS W/ TILE FINISH @ WALLS AND CEILING. COORD. FINISHW/ ID/ OWNER.B1COORD. FINAL SHOWER HEAD LOCATION, TYPE AND QUANTITY WITH ID/ OWNER.ALSO, COORD. LOCATION AND SIZE OF ANY WALL NICHE, TOWEL BAR, OR SHELF.V.I.F. W/ OWNER.B2RECESS SHOWER SLAB 6" AT FIRST FLOOR U.N.O. ROLL-IN SHOWER SLOPE TOFLOOR DRAIN. OR PROVIDE 4" HIGH CURB, VIF WITH ID/OWNER.B3PROVIDE TEMP. GL. DOOR / ENCLOSURE.B4SOFFIT AT 8'-0". VERIFY HEIGHT WITH ID/ OWNER.B5PROVIDE RAISED TUB-DECK W/ ACCESS AND VENTILATION TO SPA MOTOR PERMFR.'S WRITTEN INSTRUCTIONS. COORD. W/ ID PACKAGE/ OWNER.B6SEATB740" HIGH KNEEWALL WITH TEMP. GLASS ENCLOSURE ABOVE.B8PROVIDE SHOWER VALVE ACCESS PANEL. COORD. WITH ID/ OWNER.E: ELECTRICALE1 ALLOW FOR ELEC. CHASE TO KITCHEN ISLAND. SEE ELECTRICAL NOTES ONELECTRICAL SHEETS.F: FIRE RATING/ FIRE SAFETYF1FBC R302.5 OPENING PROTECTION. SEE FIRE RATING NOTES.F2FBC R302.6 SEPARATION REQUIRED. SEE FIRE RATING NOTES.F3CMU WALL. PROVIDE MIN. EQUIVALENT FIRE SEPARATION PER FBCR TABLE R302.6.SEE FIRE PROOFING NOTES.F4FBC R302.7 UNDER STAIR PROTECTION. SEE FIRE RATING NOTES.F5ESCAPE AND RESCUE OPENING. MUST MEET REQUIREMENTS OF FBCR 310.F6SEE FIRE RATING NOTES ON A0.2G:GENERALG1WALL NICHE. V.I.F. W/ OWNERG2BUILT-IN UNITA. ENTERTAINMENT CENTERB. BUILT-IN UNIT ENCASES WINDOW.C. PARTITIONG3ROD AND SHELF. COORD. WITH OWNER/ ID.G4GLAZING IN HAZARDOUS LOCATIONS (FBC R308.4) TO BE SAFETY GLAZING (FBCR308.3.1)G5GUARD AND DECORATIVE HANDRAILING SYSTEM 36" AFF w/ 1-1/2" DIA. TOP HANDRAIL.SEE FLOOR PLAN TYPICAL NOTES. FINAL MATERIAL, DESIGN, AND FINISH WITHOWNER/ ID.G6HANDRAIL. 1 12" DIA. HANDRAIL 36" AFF.G7SCREEN DOOR. 3'-0" X 6'-8" V.I.F.G8RETRACTABLE SCREEN. SEE DETAILS.G9POWDER COATED ALUMINUM FENCE AND GATE. PAIR 2'-6" X 5'-0". VERIFY WITHOWNER.G10COURTYARD WALL. SEE SITE DRAWINGS. SEE STRUCTURAL DRAWINGS.G11CONTROL JOINTM: MECHANICALM1A/C COMPRESSOR. COORD. W/ MECH. CONTRACTORM2AIR HANDLING UNIT. COORD. W/ MECH. CONTRACTOR. SEE HVAC GENERAL NOTESON SHEET MEP 0.1.A. HORIZONTAL UNIT IN ATTIC/SOFFITB. HORIZONTAL UNIT SUSPENDED FROM CEILINGM3POOL EQUIPMENT. COORD. WITH POOL CONTRACTORM4MECHANICAL DUCT CHASE.M5ATTIC ACCESSA. 22" X 54" w/ PULL DOWN STAIRB. 30" x 54" w/ PULL DOWN STAIRM6MECHANICAL SCREENS: PROVIDE LANDSCAPE SCREEN PER AHJ.P: PLUMBINGP1SINK WITH DISPOSAL. COORD. FINAL LOCATION OF MAIN KITCHEN SINK WITHID/OWNER.P218" SINKP3LAUNDRY TUBP450 GALLON WATER HEATER. COORDINATE WITH CONTRACTOR.P5 HOSE BIB. VLIF. COORD. PROJECTION FROM WALL WITH FINAL WALL FINISH.03-03-2101Kitchen22'-0"Family22'-0"2-Car Garage10'-0"PANTRYEntry22'-0"Study10'-0"Dining10'-0"Master10'-0"WIC10'-0"MasterBath10'-0"Lndry10'-0"SHWR.Bath 410'-0"SHOWERFoyer10'-0"COATCLOSETOutdoorLiving10'-0"CLOSET70'-0"42'-8"2'-4"5'-0"10'-0"10'-0"PROPERTY LINE1FIRST FLOOR PLAN SCALE: 1/4" = 1' - 0"OPTION #11'-0"4'-4"64'-8" 25'-8"8'-8"30'-4"14'-8"6'-8"21'-4"3'-4"4'-0"4'-0"3'-4"8"4'-8"1'-4"1'-0"9'-0"1'-0"9'-0"1'-4"70'-0" 45'-4"7'-4"14'-0"3'-4" 10'-2"7'-10"13'-4"14'-0"3'-0"4'-4"12'-8"1'-4"42'-8"15'-4"14'-8"12'-8"3'-4"4'-4"4'-4"3'-4"13'-4"1'-4"5'-6"7'-2"8"20'-4"6"2'-2"15'-8"1'-2"6'-2"8"2'-4"11'-8"3'-4"3'-0"1'-4" 5'-4"8"17'-8"3'-6"7'-4"4'-10"7'-4"8" 6'-0"3'-0"1'-5"3'-5"3'-10"15'-8" 8"11'-10"3'-2"4'-2"6"3'-10" 6'-4"3'-0"6'-8"9'-6"17'-0"8"7'-6"7'-2"8"1'-6"3'-4"3'-0"10"4'-10"8"8"21'-2"2'-6"2'-8"2'-10"6'-6"5'-8"8"5'-4"6"3'-6"3"3"6"2'-10"4"3'-0"4"2'-0" 2'-6"3'-0"10"3'-0"8"13'-7"6'-7"6"5'-2"3'-4"4"3'-8"8'-2"8"8"3'-0"2'-8"4'-0"6"6'-4"6"10'-8"10'-0"8"6"5'-8"6'-0"8"4'-8"5'-0"3'-8"8"3'-0"3'-0"A3A4A5A1A2P3P1M2BM5M1G5G3G3G3G3B1B2B3B1B2B3E1(2)2680 2060 FG9080 OHGDSLOPE MIN. 1 8" per ft.9080 OHGD 2060 FG 2060 FG 3060 CSMT 2880 28802 8 8 0 28802880 20802680 PKT28802 6 8 0 268030809080 SGD 3060 CSMT 3060 CSMT 3060 CSMT 3060 CSMT 3060 CSMT 3050 CSMT 5050 FG 4020 FG INDICATES 2ndFLOOR LINEINDICATES 2nd FLOOR LINE INDICATES 2ndFLOOR LINEINDICATES 2ndFLOOR LINE3080 W/1880 SLTUB4" P5 P5 P5UP3'-8"2'-4"2'-6"3'-4"4'-6"9080 SGD2A3.22A4.1F5 F5P46"2X6 WALL2X6 WALL 2X6 WALL 2X6 WALL2X8 WALL3A7.1SLOPE MIN. 1 8" per ft. SLOPE MIN. 1 8" per ft.2A7.11A7.1TOP OF OPN'G @ 9'-0"TOP OFOPN'G@ 9'-0"TOP OF OPN'G @ 9'-0" 8"CMU WALLCMU WALL2480 B7 4" SLOPE MIN. 1 8" per ft. 4"6"4" 4"F1F2F4F6G4B8V.T.E.G11 G11 G11 PatioTHE GENERAL CONTRACTOR SHALL PROVIDE RESIDENTIAL FIRESPRINKLER PROTECTION IN ACCORDANCE WITH FBCR 6th EDITION(2017) SECTION 903.3.1.3 NFPA 13D SPRINKLER SYSTEMS. FIREPROTECTION SUBCONTRACTOR TO SUPPLY ARCHITECT W/ TWO (2)COPIES OF SHOP DRAWINGS, HYDROLOGY AND SYSTEM LAYOUTFOR APPROVAL PRIOR TO CONSTRUCTION.NOTE: DO NOT PAINT SPRINKLER HEADSRESIDENTIAL FIRE SPRINKLER SYSTEMA1.12017-11-08SHEET NOSCALE 10/15/2019 AS INDICATED PROJECT NO DATE 1511 CHK BY NAG DRAWN BY Ph: 407-647-0938 Fax: 407-647-2499 email : Mark@nasrallah.com 3920 Edgewater Drive, Suite 101 Orlando, Fl. 32804 AA26001471 MARKDATE REMARK BY MN Designer hereby expressly reserves his copyright and other property rights in these plans. These plans and drawings are not to be reproduced, changed or copied in any form or manner whatsoever without first obtaining the express permission and consent of the architect., nor are they to be assigned to any party without first obtaining said written permission and consent. Written Dimensions on these drawings shall have precedence over scale dimensions: Contractors shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. Architectural Group Inc 2020-12-22 Building Department Permit Set not valid withoutoriginal or electronicsignature & sealMark P. NasrallahFla. Reg. AR 0008136Accuracy StatementThis item has been digitally signed and sealed by Mark P Nasrallah on the date containedwithin the digital signature above. Printed copies of this document are not consideredsigned and sealed and the signature must be verified on any electronic copiesSt. Lucie County, FL Gelcorp. Industries A Custom Residence For: "AVALON BY THE BEACH" - LOT 28 PARCEL ID 2021-03-03 01 BLDG DEPT. COM. CW