HomeMy WebLinkAbout010-A6.1DOOR_WDW_Lot28WINDOW AND DOOR KEY NOTES:1.EXTERIOR WALL ASSEMBLY VARIES- SEE WALL SECTIONS AND PLANS.2.WATERPROOFING SYSTEM. SEE DOOR AND WINDOW INSTALLATIONDETAIL, THIS SHEET.3.WALL FINISH VARIES. SEE WALL SECTIONS AND ELEVATIONS.4.INSTALL ASSEMBLY PER MANUFACTURER'S WRITTEN INSTRUCTIONS.SEE DOOR AND WINDOW INSTALLATION DETAIL, THIS SHEET.5.SLOPE CEMENT WASH SLIGHTLY DOWNWARD AWAY FROM THE UNIT ATHEAD ONLY.6.DOOR / WINDOW UNIT - SEE SCHEDULE7.WINDOW SILL - SEE WALL SECTIONS AND ELEVATIONS FOR MATERIALAND PROFILE.8.CONT. P.T. 2X BUCK - SEE DOOR AND WINDOW INSTALLATION DETAILFOR ATTACHMENT, THIS SHEET. ALSO SEE WALL SECTIONS.9.CONT. CLOSED CELL FOAM BACKER ROD AND SEALANT - SEE MFG'R.WRITTEN INSTRUCTIONS & INSTALLATION DETAILS10.SHIM AS REQ'D.11.CONT. PVC J-BEAD12.CONTINUOUS DRIP EDGE AT EXTERIOR HEAD. SEE ELEVATIONS ANDWALL SECTIONS. DETAIL MAY VARY.13.DRYWALL AND FURRING. SEE WALL SECTION.14. FLOOR/ WALL FINISH AT BALCONIES. COORD WITH ID/ OWNER.15.WATERPROOFING SYSTEM AT BALCONIES. SEE DETAIL.16. EMBED DOOR SILL IN SEALANT.17. PROVIDE COPPER/STAINLESS STEEL PAN WITH SOLDERED END DAMBS18. PROVIDE SPACER AS NEEDED FOR FLOORING SYSTEM.19.PRECAST SILL.20.PROVIDE WICK WEEP IN MORTAR SETTING BED.NOTE: DOOR / WINDOW CASING AND JAMB EXTENSION NOT SHOWN FORCLARITY - COORD. WITH OWNERGENERAL DOOR AND WINDOW NOTES1. ALL GLAZING IN HAZARDOUS LOCATIONS AS IDENTIFIED BY FBC R308.4 TOBE SAFETY GLAZING IN ACCORDANCE WITH THE REQ. OF FBC R308.3.1.2. ALL GLAZING TO BE CLEAR - INSULATED HIGH PERFORMANCE LOW 'E'UNITS W/ A MAX. SHGC 0.25 FOR FENESTRATION AND SKYLIGHTS OR AMAX U-FACTOR OF .40 FOR FENESTRATION ( .65 FOR IMPACT RATEDFENESTRATION) AND .65 FOR SKYLIGHTS. FBC ENERGY CONSERVATIONCODE TABLE R402.1.1.3. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH THEPRODUCT MFR. FOR COMPLIANCE OF CODE REQUIREMENTS INCLUDINGBUT NOT LIMITED TO: EGRESS, WIND DESIGN DATA, INSTALLATION ANDANCHORING, WIND BORN DEBRIS REGIONS, AIR INFILTRATION, ETC...4. THE CONTRACTOR IS TO NOTIFY THE ARCHITECT OF RECORD OF ANYDISCREPANCY BEFORE ORDERING PRODUCTS.5. FLORIDA PRODUCT APPROVAL:5.1. FLORIDA PRODUCT APPROVALS ARE REQUIRED FOR ALL EXTERIOR:DOOR ASSEMBLIES, WINDOW ASSEMBLIES, IMPACT RESISTANTCOVERINGS, GARAGE DOOR ASSEMBLIES, AND UNIT SKYLIGHTASSEMBLIES.5.2.THE CONTRACTOR SHALL OBTAIN FLORIDA PRODUCT APPROVALDOCUMENTATION, INCLUDING INSTALLATION AND ANCHORING DETAILSAND REQUIREMENTS. CONTRACTOR TO:5.2.1. SUBMIT DOCUMENTATION TO THE BUILDING DEPARTMENTOR AHJ.5.2.2. RETAIN A COPY ONSITE.5.3. SEE STRUCTURAL ENGINEER'S DRAWINGS FOR DESIGNCRITERIA. WHEN SEPARATE STRUCTURAL ENGINEERING DOCUMENTS ARE NOT PROVIDED THIS INFORMATION WILL BELOCATED UNDER CODE INFORMATION IN THIS SET.6. COORD. MUNTON DESIGN WITH OWNER.7. MATCH WINDOW HEAD HEIGHT W/ INTERIOR DOOR HEAD HEIGHT. VERIFYW/ FINISH FLOOR MATERIALS. FINAL INTERIOR & EXTERIOR DOOR HEADHEIGHT TO BE VIF W/OWNER.DOOR NOTES1. ALL INTERIOR DOORS TO BE SOLID CORE DOORS. VERIFY ALL SPECIES,FINISH (PAINT-STAIN), & HEIGHT WITH ID/OWNER PRIOR TO FABRICATION.2. SEE ID/OWNER SPECIFICATIONS FOR DOOR HARDWARE TYPE & FINISH.3. EXTERIOR DOORS TO BE CLAD INSULATED DOORS AS MANUF. BY: ESMASTER SWING DOOR (ES-3000). SLIDERS BY: ES ALUMINUM SLIDERS(EL-400). FRONT DOOR BY: PLASPRO (DRA1P80)4. GARAGE DOOR TO BE STEEL PANELED INSULATED WITH FINISHEDINTERIOR PANEL, COLOR AS SELECTED BY OWNER5. SEE ID FOR WINDOW/DOOR HJS TREATMENT6. ALL DOOR UNITS TO COMPLY WITH FBC ENERGY CONSERVATION CODESECTION R402.4. AIR LEAKAGE.7. ALL DOORS & WINDOWS SHALL COMPLY WITH BARRIER REQUIREMENTS ASDEFINED IN FBC R CHAPTER 45 PRIVATE SWIMMING POOLSWINDOW NOTES:1. SEE WINDOW ELEVATIONS FOR SPECIFIC FIXED/ OPERABLECONFIGURATION. O.N.O. BEFORE ORDERING ALL WINDOWS VIF W/ OWNER.2. WINDOWS ARE TO BE MANUFACTURED BY: ES ALUMINUM WINDOWS (FIXED:EL-150 & CASEMENT: ES5000).COLOR AND HARDWARE AS SELECTED BY OWNER/ IDBASE DESIGN STANDARD: U = .4, SHGC = .25VERIFY: 78" SDL INTERIOR & EXTERIOR GRILLES (NO SPACE BAR)SCREEN TYPE PER MANUF3. COORD. SPECIFIC SILL AND TRIM CONDITIONS W/ ELEVATIONS.4. ALL FENESTRATION TO COMPLY WITH FBC ENERGY CONSERVATION CODESECTION R402.4.3. AIR LEAKAGE.5. ALL FIRST FLOOR WINDOWS WITH A CLEAR PATH TO A POOL AND SECONDFLOOR WINDOW WITH ACCESS TO A DECK THAT LEADS TO A POOL SHALLCOMPLY WITH EXIT ALARM PER FBC R4501.17.1.96. EGRESS WINDOW NOTES:6.1 EGRESS WINDOWS ARE TO COMPLY WITH FBC R310.-SILL HEIGHT NOT MORE THAN 44" AFF.6.2 PER FBC R310.1.1-FOR FLOORS ABOVE OR BELOW GRADE EGRESS WINDOWS MUSTCOMPLY WITH A MIN. NET CLEAR OPENING OF 5.7 SQ. FT-FOR FLOORS AT GRADE EGRESS WINDOW MUST COMPLY WITH A MIN.NET CLEAR OPENING OF 5 SQ. FT.6.3 WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORETHAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW,THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BEA MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM INWHICH THE WINDOW IS LOCATED PER FBC R 312.2.03-03-210103-03-210129721891024MIN. 1/4" / FT.61415FLOOR SYSTEM169321611412913108SEE ELEV. & SECT.53DOOR SILL DETAILSCALE: 3" = 1' - 0"1DOOR HEAD (JAMB SIMILAR)SCALE: 3" = 1' - 0"2WINDOW HEAD (JAMB SIMILAR)SCALE: 3" = 1' - 0"4WINDOW SILL DETAILSCALE: 3" = 1' - 0"41718361913321611412951310820VERIFY FINISH FLOOR DIMENSIONS INTERIOR WALLEXTERIOR WALL78" MIN.18" MIN.PANEL BOTTOM RAILTYP. SILLWEEP HOLE (DO NOTBLOCK WITH EXTERIORFINISH FLOOR MATERIAL)CONCRETE SLAB S.S.D.EXTERIOR FINISH FLOORMUD SETINTERIOR FINISH FLOORTRACK LENGTH VARIESTandemRollTandemRollTandemRoll7SGD SILL - FLUSHSCALE: 3" = 1' - 0"5SGD JAMB/HEADSCALE: 3" = 1' - 0"13 1 2 3 4 6 8 99 11 EXTERIORINTERIORVERIFY FINISH FLOOR DIMENSIONS INTERIOR WALLEXTERIOR WALL78" MIN.18" MIN.PANEL BOTTOM RAILTYP. SILLWEEP HOLE (DO NOTBLOCK WITH EXTERIORFINISH FLOOR MATERIAL)CONCRETE SLAB S.S.D.MUD SETINTERIOR FINISH FLOORTRACK LENGTH VARIESTandemRollTandemRollTandemRoll6SGD SILL - STEPSCALE: 3" = 1' - 0"EXTERIOR FINISH FLOORTYPARTYPARTYPARTYPARTYPAR TYPAR FRAME WALLMASONRY WALL11a322a443452a62141a2WDW NOTSHOWN FORCLARITY1WINDOW & DOOR INSTALLATIONSCALE: 1 1/2" = 1' - 0"WINDOW & DOOR INSTALLATION:- COORDINATE COMPATIBILITY OF ALL PRODUCTS WITH OTHERPRODUCTS USED WITHIN THE ASSEMBLY; INCLUDING, BUT NOT LIMITEDTO, ALL SEALANTS AND INTERIOR AND EXTERIOR FINISHES THAT COMEIN CONTACT WITH THESE PRODUCTS.- PROTECT ALL PRODUCTS AGAINST ATMOSPHERIC AND UV EXPOSUREPER MANUFACTURER'S WRITTEN INSTRUCTIONS.1. UNPROTECTED EXTERIOR WALL ASSEMBLY:- MASONRY CONSTRUCTION- FRAME ASSEMBLY - INSTALL TYPAR WEATHER RESISTANTBARRIER MEMBRANE PER MANUFACTURER'S WRITTENINSTRUCTIONS (CONTRACTOR TO SUBMIT ALTERNATIVE TOARCHITECT FOR REVIEW). AT SIDES AND BOTTOM OF OPENINGSHOLD TYPAR BACK 2" FROM EDGE OF OPENING TO ALLOWPROSOCO R-GUARD "FAST FLASH" TO BE APPLIED DIRECTLY TOTHE SHEATHING FOR THE FIRST 2".1a. PREPARE ROUGH OPENING - SEE PROSOCO R-GUARD SYSTEM FORMANUFACTURER'S WRITTEN INSTRUCTIONS.2. PT BUCK:MASONRY CONSTRUCTION- INSTALL 2x WITH RECESSED 14" Ø x312"TAPCONS AT 8" O.C. STAGGERED.2a. RECESS TAPCON AND/OR NAILS AND SEAL WITH PROSOCO R-GUARD "JOINT AND SEAM FILLER".3. AFTER INSTALLING PT BUCK - APPLY PROSOCO R-GUARD "JOINT ANDSEAM FILLER", PER MANUFACTURER'S WRITTEN INSTRUCTIONS.4. APPLY PROSOCO R-GUARD "FAST FLASH" PER MANUFACTURER'SWRITTEN INSTRUCTIONS.-ON FRAME ASSEMBLIES: APPLY PROSOCO R-GUARD "FASTFLASH" OVER TYPAR ON SIDES AND BOTTOM OF ASSEMBLY, ANDUNDER TYPAR DIRECTLY TO SHEATHING AT TOP OF ASSEMBLY.VERIFY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.-ON MASONRY ASSEMBLIES: REFER TO MANUFACTURERREPRESENTATIVE FOR RECOMMENDATIONS AT DIRECT APPLIEDSTUCCO APPLICATIONS ON EXTERIOR FACE OF WALL.5. INSTALL WINDOW ASSEMBLY PER WINDOW MANUFACTURER'SWRITTEN INSTRUCTIONS.NOTE: WHEN INSTALLING WINDOWS WITH FINS, ENCAPSULATETHE FIN WITH PROSOCO R-GUARD "JOINT AND SEAM FILLER".LEAVE OUTER COAT OPEN AT BOTTOM FIN FOR WEEPING.6. INSTALL BACKER ROD AND SEALANT AT INTERIOR SIDE OF THE UNITALONG THE BOTTOM OF THE UNIT AND UP 12" ON EACH SIDE. SEEMANUFACTURER'S WRITTEN INSTRUCTIONS.A6.12017-11-08SHEET NOSCALE 10/15/2019 AS INDICATED PROJECT NO DATE 1511 CHK BY NAG DRAWN BY Ph: 407-647-0938 Fax: 407-647-2499 email : Mark@nasrallah.com 3920 Edgewater Drive, Suite 101 Orlando, Fl. 32804 AA26001471 MARKDATE REMARK BY MN Designer hereby expressly reserves his copyright and other property rights in these plans. These plans and drawings are not to be reproduced, changed or copied in any form or manner whatsoever without first obtaining the express permission and consent of the architect., nor are they to be assigned to any party without first obtaining said written permission and consent. Written Dimensions on these drawings shall have precedence over scale dimensions: Contractors shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. Architectural Group Inc 2020-12-22 Building Department Permit Set not valid withoutoriginal or electronicsignature & sealMark P. NasrallahFla. Reg. AR 0008136Accuracy StatementThis item has been digitally signed and sealed by Mark P Nasrallah on the date containedwithin the digital signature above. Printed copies of this document are not consideredsigned and sealed and the signature must be verified on any electronic copiesSt. Lucie County, FL Gelcorp. Industries A Custom Residence For: "AVALON BY THE BEACH" - LOT 28 PARCEL ID 2021-03-03 01 BLDG DEPT. COM. CW