Loading...
HomeMy WebLinkAboutAPPROVED 0130_001M,AMI'�ut MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) ►nvw.rniamidade.Qaylerono�m James Hardie Building Product, Inc. 10901 Elm Avenue Fontana, CA 92337 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020, bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami - Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 17-0821.21 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 20-0730.06 6t��e Expiration Date: May 1, 2022 Approval Date: November 12, 2020 Page 1 James Hardie Huactin Yroci acts. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs A. DRAWINGS "Submitted under NOA # 13-0311.07" 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, Cem.Panel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald 1. Ogawa, P.E. B. TESTS "Submitted under NOA # 13-0311.07" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No. 100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and sealed by Rick Curkeet, P.E. "Submitted under NOA # 02-0729.02" Laboratory Report Test Date Signature 2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E. 3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E. 4. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under NOA # I5-0122.04" 1. Statement letter of code confonnance to the 5"' edition (2014) FBC issued by Ronald 1. Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald 1. Ogawa, P.E. 49��, Carlos M. Utrera, P.E. Product Control Examiner NOA No. 20-0730.06 Expiration Date: May 1, 2022 Approval Date: November 12, 2020 E-1 James Hardie Building Products. inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 7`h Edition (2020) of the FBC and of no financial interest issued by Construction Applied Engineering, dated 07/22/2020, signed and sealed by V. Andrew Tan, P.E. "Submitted under NOA # 17-0821.21 " 2. Statement letter of code conformance to the 6" Edition (2017) FBC and of no financial interest issued by Ronald I. Ogawa & Associates, Inc., dated 07/30/2017, signed and sealed by Ronald 1. Ogawa, P.E. Carlos M. Utrera, P.E. Product Control Examiner VOA No. 20-0730.06 Expiration Date: May 1, 2022 Approval Date: November 12, 2020 E-2 WALL LENGTH Stud Spacing at 16" O.C. BE-- I I I SEE DETAIL A ----------------- J I PRODUCT REVISED as complying with the Florida Building Code NoA-No. 20-0730.06 WALL Expiration Date05/01/2022 HEIG14 By ` Miami -Dade Product Control -� -' I DETAIL A t I I l r 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. RA S N .i Zl- NO. 156 2. TATEOff: LuOR 1; f Nails at 16" O.C. (typ.) 3/8" Minimum Edge Distance Sheathing fastener, as described in Note 1 \ Panel fastener, as described in Note 2 11 HardiePanel, Cempanel, Prevail Panel Siding Water -resistive barrier per -� Florida Building Code Section ! 1404.2 5/8" thick / 5 ply APA rated plywood sheathing fastened in accordance with Florida Building James Hardie BL Code Section 2322.3 • 10901,E III 16 Fontana Phone: 909-356-6300 SIZE FSCM NO Fax 909-427-0634 A Creator: E. Gonzales SCALE 1/2" = 1'-0" Date: 9/2S SECTION B-B 5/8" thick / 5 ply APA rated plywood sheathing in accordance with Florida Building Code Section 2322.3 Water -resistive barrier per Florida Building Code Section 1404-2 2" X 4" S-P-F Wood Studs HardiePanel, Cempanel, Prevail Panel Siding HARDIEPANEL, CEMPANEL PREVAIL PANEL SIDING IN ■ All installation shall be done in conformance with this Nu installation recommendations, and the applicable section • Wood studs where HardiePanel, Cempanel, Prevail Panl designed by an Engineer or Architect per the Florida Buil N.O.A. • [Note 1 ] 5/8" thick / 5 ply APA rated plywood sheathing accordance with Florida Building Code Section 2322.3. ■ The siding panels shall be installed over 5/8" thick 15 ply by a minimum of 2"X4" S-P-F wood studs spaced a maxi ■ [Note 2] The siding panel fastener shall be a 2" long, 0.2 diameter, corrosion resistant siding nail; the fasteners sh and intermediate studs; the fasteners shall be driven thrc plywood sheathing into wood studs located at 16" O.C. ■ Fasteners shall have a minimum edge distance of 3/8" al corners. HARDIEPANEL, CEM INSTALLATION DETAILS V Fastener Spacing per Florida Building Code Section 2322.3 i r �. _ -� ' � Fastener Spacing per Florida Building Code Section 2322.3 ,11QE ! Tq 'IJ PRODUCT REVISED complyingas with the Florida c N S �' • �� Building Cade w�V 2 70 �f NOA-No. 20-0730.06 ;,�x p- $1662 * • Expiration Date05/01/2022 EEBy -- = y OF •, r Miami -Dade Product Control re -1 .qt:\ • �j r FRAMING • NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) ■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING ■ NOMINAL 5Z' THICK / 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUILDNG CODE SECTION 2322.3 CLAWING ■ THE PANEL IS FASTENED WITH 2" LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION RESISTANT SIDING NAILS, PLACE NAILS 6" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM A NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PRC HARDIEPANEL, CEN INSTALLATION DETAILS V James Hardie Bi 109011 • Fontan, Phone: 909-356-6300 s¢E FSCM NO k Fax 909 427-0634 A Creator: E. Gonzales SCALE 1" = 1'-0" Date: 9/2! WALL LENGTH Stud Spacing at 16" O.C. BF 1- I -j SEE DETAIL A WALL IEIGHT .i PRODUCT REVISED`N as complying with the Florida �� �`". •\.� f `� r �� Building Code ;1`, ,�A,r}j�,s Z I zs-4 `• NOA-No. 20-0730.06 Expiration Date 05/01 /2022 '••iV0.816i72•; t * 1 =j -- sy — << Miami -Dade Product ControlA. STATE OF j \• IOf V�`,�~` 1 I € AL /71�/!l111111r����LWr�} ., 5/8" thick / 5 ply APA rated plywood sheathing fastened to metal studs as described in Note 1 Water -resistive barrier per Florida Building Code Section 1404.2 20ga, 3-5/8" X 1-5/8" Metal C-stud - LJI HardiePanel, i SECTION B-B Cempanel, Nails at 6" O.C. (typ.) Prevail Panel 3/8" Minimum Edge Distance Siding HARDIEPANEL, CEMPANEL, PREVAIL PANEL SIDING IN • All installation shall be done in conformance with this No installation recommendations, and the applicable sectior ■ Metal studs where HardiePanel, Cempanel, Prevail Pan( Sheathing fastener, as designed by an Engineer or Architect per the Florida Bui described in Note 1 N.O.A. ■ [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing ; Panel fastener, as described in at panel edges and all intermediate supports using a No. 7— Note 2 bugle head screw The siding panels shall be installed over 5/8" thick / 5 ply supported by a minimum 20ga, Nominal 3-5/8" X 1-5/8" 1 O.C. HardiePanel® Siding [Note 2] The siding panel fastener shall be a minimum N long* ribbed bugle head screw (*or screw shall have at k framing); the fasteners shall be spaced at 6" O.C. at pan � fasteners shall be driven through the 5/8" thick / 5 ply AF rWater -resistive barrier per studs located at 16" O.C. Florida Building Code Section . Fasteners shall have a minimum edge distance of 3/8" a 1404.2 corners. HARDIEPANEL, CEM 5/8" thick / 5 ply APA rated INSTALLATION DETAILS ry — plywood sheathing fastened James Hardie BL to metal studs as described in Note 1. 0 IL Fontana 10901 E 20ga, 3-5/8" X 1-5/8" Metal C-stud MR1 The wall and soffit frames are to be designed Phone: 909-356-6300 I SIZE FSCM NO by the Architect or Engineer of Record in �` Fax 909-427-0634 __tA compliance with the Florida Building Code_ Creator: E. Gonzales SCALE 1/2" = V-0" Date: 9/29 6.00in. �_16.00in. i 6.00in. 6.00in. • T 6.00in. • PRODUCT REVISED / as complying with the Florida Building Code NOA-No. 20-0730.06 Expiration Date 05/01 /2022 By _. - Miami -Dade Product Control FRAMING • NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 5/8" WAFER HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM / BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PR( COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING ■ NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL, CEh NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE INSTALLATION DETAILS I HEAD SCREW CLADDING • THE PANEL IS FASTENED WITH NO. 8-18, 0.315" HEAD James Hardie B DIAMETER X 1-5/8 " LONG CORROSION RESISTANT 10901 RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT Fontan LEAST 3 FULL THREADS PENETRATING THE METAL Phone: 909-356-6300 SIZE FSCM NO _ FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES Fax 909-427-0634 A AND INTERMEDIATE STUDS Creator: E. Gonzales SCALE 1" = 1'-0" Date: 912 Stud Spacings at 16" O.C. WALL LENGTH BE } ----- -- ------ _------- - 77-------- I PRODUCT REVISED I i as complying with the Florida Building Code 4. 1662 •� I WALL I NOA-No. 20-0730.06 . = +,�� t i y r•: HEIGHT i Expiration Date05/01/2022 I By Miami -bade Product Control .--•------•--• •-• -r' ---- ------- - -....__-..------ ...-------- -------- ---------------- -••---•---•------...---•---- BE 3/4" Minimum Edge Distance Nails at 16" O.C. (typ.) DETAIL A _ Sheathing fastener, as i described in Note 1 /f Siding fastener, as / described in Note 2 i i 1, HardiePlank, Cemplank, Prevail Lap Siding / Water -resistive barrier �— per Florida Building Code Section 1404.2 5/8" thick / 5 ply APA rated plywood sheathing fastened in accordance with Florida Building Code Section 2322.3 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code_ SEE DETAIL A 11 Ztr ` 5/8" thick / 5 ply AP I Ksheathing rated plywood in accordance with Florida Building Coi Section 2322.3 Water -resistive barrier per Florii Building Code Section 14042 2" X 4" S-P-F Wood Studs Lap Siding EULC , B-B 1-1/4" tall X 5/11 thick starter stril HARDIEPLANK, CEMPLANK PREVAIL LAP SIDING INSTALLA • All installation shall be done in conformance with this Notice of installation recommendations, and the applicable sections of tl- • Wood studs where HardiePlank, Cemplank, Prevail Lap Siding Engineer or Architect per the Florida Building Code and the re( [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall b with Florida Building Code Section 2322.3. Planks shall be applied horizontally commencing from the bolt( laps at the top of the plank such that the exposure area of earl ■ [Note 2] The siding fastener shall be a 2-1/2" long, 0.223" heal corrosion -resistant siding nail; The siding is fastened S B-1/4" ( fasteners are driven into wood studs through 5/8" thick / 5 ply / are placed in the overlapping area approximately 3/4" from the Vertical joints shall be placed over studs. • The planks shall be installed over 5/8" thick / 5 ply APA rated F minimum of 2"X4" S-P-F wood studs spaced a maximum of 16 • Fasteners shall have a minimum edge distance of 3/8". HARDIEPLANK, CEMPL INSTALLATION DETAILS M James Hardie BL I 10901 E Fontana Phone:909-356-6300 3IGE FSCMNO Fax909-42i-0634 A Creator: E. Gonzales SCALE 1/2" = 1'-o" Date: 9/29 Fastener Spacing per Florida Building Code Section 2322.3 �__16 in. OC--� k I i i W �'� T Fastener Spacing per Florida Building Code Section 2322.3 0.75in PRODUCT REVISED as complying with the Florida Building Code . NOA-No. 20-0730.06 - — —------ --------------- -......... . Expiration Date05/01/2022 By Miami -Dade Product Control s8.251n. — rr FRAMING • NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM AC BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROxj COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING ■ NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA HARDIEPLANK, CEMPL BUILDING CODE SECTION 2322.3 INSTALLATION DETAILS V1 CLADDING • PLANKS OVERLAP 1-1/4" _ James Hardie Bl. ■ THE EXPOSURE IS <_8-1/4" • THE PLANKS ARE FACE: NAILED WITH 2-1/2" LONG, 0.223" • � � 10901 E HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION- Fontana RESISTANT SIDING NAILS, PLACED 3/4" UP FROM THE Phone: 909-356-6300 sVE FSCM NO BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Fax 909-427-0634 A Creator: E. Gonzales SCALE V = V-0" Date: 9129 40 Stud Spacing at 16" O.C. WALL LENGTI -- -- - _ _--------- -------.----- ,, � I I "I PRODUCT REVISED f j as complying with the Florida Building Code WALL NOA-No. 20-0730.06 Expiration Date 05101 /2022 —By MIamFOade Product Cantral -•- -�' '---------- — - -- i Bt = 3/4" Minimum Edge Distance DETAIL A �r /f I f 1 .�� 'p, A 'of: {CV f--� L L) lij4itil �. - _ ---------------------- � 2$ Nails at 16" O.C. (typ.) SEE TAIL A r } SECTIi B-B 5/8" thick / 5 ply API rated plywood sheathing fastened to metal studs as described in Note 1 Water -resistive barrier per Florida Building Code Section 1404.2 20ga- 3-5/8" X 1-5/E t Metal C-stud HardiePlank, 'Cemplank, Prevail N, Lap Siding 1-1/4" tall X 5/16" thick starter strip HARDIEPLANK, CEMPLANK, PREVAIL LAP SIQING INSTALLATION ■ All installation shall be done in conformance with this Notice of Acce 1 Sheathing fastener, as recommendations, and the applicable sections of the Florida Buildin described in Note 1 Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will b ` Engineer or Architect per the Florida Building Code and the requirer [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be att-. Siding fastener, as edges and all intermediate supports using a No.8-18, 0.315" head d l described in Note 2 " Planks shall be applied horizontally commencing from the bottom cc the top of the plank such that the exposure area of each plank is <- E [Note 2] The siding fastener shall be a minimum No. 8-18, 0.315" hi HardiePlank, screw over metal studs (*or screw shall have at least 3 full threads F fastened 5 8-1/4" O.C. vertically and 16" O.C. horizontally; fastener: Cemplank, thick / 5 ply APA rated plywood sheathing, fasteners are placed in tt Prevail Lap Siding from the bottom edge of the overlapping plank_ ■ Vertical joints shall be placed over studs. Water -resistive The planks shall be installed over 5/8" thick / 5 ply APA rated plywol ~� barrier per Florida 20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a maximum of Fasteners shall have a minimum edge distance of 3/8 . Building Code -- Section 1404.2 5/8" thick / 5 ply APA rated plywood sheathing fastened to metal studs as described in Note 1 20ga, 3-5/8" X 1-5/8" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. HARDIEPLANK, CEMPL INSTALLATION DETAILS W James Hardie BL 10901 E Fontana Phone: 909-356-6300 svuF FSCM NO Fax 909-427-0634 A Creator: E. Gonzales SCALE 1 /2" = 1'-0" f Date: 9/29 6.00in. F 6.0110•in, lI ��---16 in. OC--- . 6.00in.00 1 0.75in PRODUCT REVISED as complying with the Florida Building Code �. -•---- -• NOA-No. 20-0730.06 ------•- ----------------------- Expiration Date05/01/2022 By :. Miami -Dade Product Control • ■ ----------•------ ------ --- -- ---- ---------�- - — --�_ ..----- <8.25in. �. FRAMING ■ NOMINAL 20 GAUGE 3-518" X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 5/8" LONG RIBBED BUGLE HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) ■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM A BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PRO COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE HEAD SCREW HARDIEPLANK, CEMPL CLADDING INSTALLATION DETAILS N ■ PLANKS OVERLAP 1-1/4" ■ THE EXPOSURE IS _< 8-1/4" James Hardie BI. ■ THE PLANKS ARE FASTENED WITH NO. 8-18, 0.315" , 10901 E HEAD DIAMETER X 2-1/4" LONG CORROSION- Fontana RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS Phone_ 909-35E>-5300 SIZE FscM No PENETRATING THE METAL FRAMING), PLACED 3/4" UP Fax 909 427-0634 A FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Creator: E. Gonzales scplF 1" =1'-0" Date: 9/29 WALLLENGTH Stud Spacing at 16" O.C. B F--I I -- .I .E_ i j i = I PRODUCT REVISED j as complying with the Florida t Building Code 1 I' NOA-No. 20-0730.06 WALL HEIGHT': I Expiration Date05/01/2022 j B Miami -Dade Product Control t -- y - _ - - - -- - --- - -- DETAIL A TNails at 4" O.0 (typ.) 3/8" Minimum Edge Distance SEE PRODU DETAIL A HardieS -------T_ nonasbe r ^1 accorda l !ti and mee 1 Building SOFFITWidth 2" X 4" S-P-F r' Wood Studs 4' DESIGN HardieSoffit, Installati Cemsoffit Wood S 55ECTIOIV 8-B 51 'fr HARDIESOFFIT. CEIVISOFFIT PANEL INSTALLATION DETAIL: 'offit fastener, as - All installation shall be done in conformance with this Notice c lescribed in Note 1 installation recommendations, and the applicable sections of I Wood studs where HardieSoffit, Cemsoffit will be installed shl Architect per the Florida Building Code and the requirements HardieSoffit, Cemsoffit The soffit shall be installed over minimum 2"X4" S-P-F wood: [Note 1] The soffit fastener shall be a 2" long, 0.223" head di-, corrosion resistant siding nail; the fasteners shall be spaced s intermediate studs; the fasteners shall be driven into wood sti Fasteners shall have a minimum edge distance of 3/8" and a HARDIESOFFIT, INSTALLATION DETAILS \6 -F Wood Studs James Hardie Bt mes are to be 10901 E itect or Fontana i compliance Phone: 909-35&8300 SIZE FSCM NO ng Code. Fax 909-427-0634 A Creator: E. Gonzales SCALE 1/2" = 1'-0" Date: 9/25 4.4ain. s� 16.00in. 4.00in.1 . � PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0730.06 Expiration Date 05/01 /2022 By Miami -Dade Product Control . . r FRAMING NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CLADDING THE SOFFIT IS FASTENED WITH 2" LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION RESISTANT SIDING NAILS, PLACE NAILS 4" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM AC NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PRO\ HARDIESOFFIT, INSTALLATION DETAILS V James Hardie BI 10901 E FontanE Phone: 909-3513-6300 slzE FSCM No Fax 909-427-0634 A Creator: E. Gonzales SCALE 1" = V-0" Date: 9/2E - — WALL LENGTH - Stud Spacing at 16" O.C. BF— I f, --- --- �: PRODUCT REVISED I as complying with the Florida Building Code NOA-No. 20-0730.06 WALL j Expiration D��ate05101/2022 IEIGHT ; ' f By Irk - Miami -Dade Miami -Dade Product Control I � y 1.- .-..5... _ -.• --- - - •-------- Nails at 6" O.C. (typ.) 3/8" Minimum Edge Distance DETAIL A r f I SEE DETAIL A Ile I 20ga, 3-518" X 1-5/8" Meta: C-stud HardieSoffit, Cemsoffit SECTION BBB E H a tE C rf C S V 0 Ir N HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DE • All installation shall be done in conformance with this Nc installation recommendations, and the applicable sectioi Soffit fastener, as Metal studs where HardieSoffit, Cemsoffit will be installe described in Note 1 Architect per the Florida Building Code and the requirerr The soffit shall be installed over minimum 20ga, Nomina a maximum of 16" O.C. HardieSoffit, Cemsoffit [Note 1] The soffit fastener shall be a minimum No. 8-1 f ribbed bugle head screw (*or screw shall have at least 3 framing);the fasteners shall be spaced at 6" O.C. at pane fasteners shall be driven into metal studs located at 16" Fasteners shall have a minimum edge distance of 3/8" a corners. 20ga, 3-5/8" X 1-5/8" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. Phone: 909-356-6300 Fax 909-427-0634 Creator: E. Gonzales HARDIESOFFIT, INSTALLATION DETAILS N James Hardie BL 10901 E Fontana E �-SCM NO A SCALE 1/2" = 1'-0" i Date: We - — - 6.00in.� � �16A0in� �-- — 6.00in. PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0730.06 Expiration Date 05/01 /2022 B rd v Y Miami -Dade Product Control ■ FRAMING ■ NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 5/8" WAFER HEAD SCREWS (2 PER TOP FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM A( AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROM ■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CLADDING HARDIESOFFIT, THE SOFFIT IS FASTENED WITH NO. 8-18, 0.315" HEAD INSTALLATION DETAILS N DIAMETER X 1-1/4 " LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 11011 FULL THREADS PENETRATING THE METAL FRAMING), PLACE James Hardie BI SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE 10901 E STUDS Fontana Phone: 909-356-6300 slzE FSCM NO Fax 909-427-0634 A Creator: E. Gonzales SCALE Date: 9/2E