HomeMy WebLinkAboutAPPROVED 0130_001M,AMI'�ut MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) ►nvw.rniamidade.Qaylerono�m
James Hardie Building Product, Inc.
10901 Elm Avenue
Fontana, CA 92337
SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product
Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit
APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail
Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details
Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the
manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020, bearing the Miami -Dade County
Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -
Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the
following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control
Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit
panels.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 17-0821.21 and consists of this page 1 and evidence pages E-1 and E-2, as well
as approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No. 20-0730.06
6t��e Expiration Date: May 1, 2022
Approval Date: November 12, 2020
Page 1
James Hardie Huactin Yroci acts. Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs
A. DRAWINGS "Submitted under NOA # 13-0311.07"
1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, Cem.Panel, Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel;
Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated
04/24/2013, prepared by the manufacturer, signed and sealed by Ronald 1. Ogawa,
P.E.
B. TESTS "Submitted under NOA # 13-0311.07"
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit
and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No.
100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and
sealed by Rick Curkeet, P.E.
"Submitted under NOA # 02-0729.02"
Laboratory Report Test Date Signature
2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E.
3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E.
4. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves P.E.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS "Submitted under NOA # I5-0122.04"
1. Statement letter of code confonnance to the 5"' edition (2014) FBC issued by Ronald
1. Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald 1.
Ogawa, P.E.
49��,
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0730.06
Expiration Date: May 1, 2022
Approval Date: November 12, 2020
E-1
James Hardie Building Products. inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation
Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013,
prepared by the manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 7`h Edition (2020) of the FBC and of no
financial interest issued by Construction Applied Engineering, dated 07/22/2020,
signed and sealed by V. Andrew Tan, P.E.
"Submitted under NOA # 17-0821.21 "
2. Statement letter of code conformance to the 6" Edition (2017) FBC and of no financial
interest issued by Ronald I. Ogawa & Associates, Inc., dated 07/30/2017, signed and
sealed by Ronald 1. Ogawa, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
VOA No. 20-0730.06
Expiration Date: May 1, 2022
Approval Date: November 12, 2020
E-2
WALL LENGTH
Stud Spacing at 16" O.C.
BE-- I I I
SEE
DETAIL A
-----------------
J I
PRODUCT REVISED
as complying with the Florida
Building Code
NoA-No. 20-0730.06
WALL Expiration Date05/01/2022
HEIG14
By
` Miami -Dade Product Control
-� -'
I
DETAIL A
t
I
I
l
r
2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
RA
S N
.i Zl-
NO. 156
2.
TATEOff: LuOR
1;
f
Nails at 16" O.C. (typ.)
3/8" Minimum Edge Distance
Sheathing fastener, as described in
Note 1
\ Panel fastener, as described in
Note 2
11 HardiePanel, Cempanel,
Prevail Panel Siding
Water -resistive barrier per
-� Florida Building Code Section
! 1404.2
5/8" thick / 5 ply APA rated
plywood sheathing fastened in
accordance with Florida Building James Hardie BL
Code Section 2322.3
• 10901,E
III 16 Fontana
Phone: 909-356-6300 SIZE FSCM NO
Fax 909-427-0634 A
Creator: E. Gonzales SCALE 1/2" = 1'-0" Date: 9/2S
SECTION B-B
5/8" thick / 5 ply APA rated
plywood sheathing in
accordance with Florida
Building Code Section
2322.3
Water -resistive
barrier per Florida
Building Code
Section 1404-2
2" X 4" S-P-F
Wood Studs
HardiePanel,
Cempanel,
Prevail Panel
Siding
HARDIEPANEL, CEMPANEL PREVAIL PANEL SIDING IN
■ All installation shall be done in conformance with this Nu
installation recommendations, and the applicable section
• Wood studs where HardiePanel, Cempanel, Prevail Panl
designed by an Engineer or Architect per the Florida Buil
N.O.A.
• [Note 1 ] 5/8" thick / 5 ply APA rated plywood sheathing
accordance with Florida Building Code Section 2322.3.
■ The siding panels shall be installed over 5/8" thick 15 ply
by a minimum of 2"X4" S-P-F wood studs spaced a maxi
■ [Note 2] The siding panel fastener shall be a 2" long, 0.2
diameter, corrosion resistant siding nail; the fasteners sh
and intermediate studs; the fasteners shall be driven thrc
plywood sheathing into wood studs located at 16" O.C.
■ Fasteners shall have a minimum edge distance of 3/8" al
corners.
HARDIEPANEL, CEM
INSTALLATION DETAILS V
Fastener Spacing per Florida
Building Code Section 2322.3
i
r
�. _ -� '
� Fastener Spacing per Florida
Building Code Section 2322.3
,11QE ! Tq 'IJ PRODUCT REVISED
complyingas with the Florida
c N S �' • �� Building Cade
w�V 2 70 �f NOA-No. 20-0730.06
;,�x p- $1662 * • Expiration Date05/01/2022
EEBy --
= y OF •, r Miami -Dade Product Control
re -1 .qt:\
• �j r
FRAMING
• NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND
BOTTOM CONNECTION)
■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
■ NOMINAL 5Z' THICK / 5 PLY APA RATED PLYWOOD
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA
BUILDNG CODE SECTION 2322.3
CLAWING
■ THE PANEL IS FASTENED WITH 2" LONG, 0.223" HEAD
DIAMETER, 0.092" SHANK DIAMETER, CORROSION
RESISTANT SIDING NAILS, PLACE NAILS 6" O.C. AT
PANEL EDGES AND INTERMEDIATE STUDS
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM A
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PRC
HARDIEPANEL, CEN
INSTALLATION DETAILS V
James Hardie Bi
109011
• Fontan,
Phone: 909-356-6300 s¢E FSCM NO k
Fax 909 427-0634 A
Creator: E. Gonzales SCALE 1" = 1'-0" Date: 9/2!
WALL LENGTH
Stud Spacing at 16" O.C.
BF 1- I -j
SEE
DETAIL A
WALL
IEIGHT
.i
PRODUCT REVISED`N
as complying with the Florida
�� �`". •\.� f `� r ��
Building Code
;1`,
,�A,r}j�,s Z I zs-4 `•
NOA-No. 20-0730.06
Expiration Date 05/01 /2022
'••iV0.816i72•;
t * 1
=j
--
sy —
<<
Miami -Dade Product ControlA.
STATE OF j
\•
IOf V�`,�~` 1
I
€
AL
/71�/!l111111r����LWr�}
.,
5/8" thick / 5 ply APA rated
plywood sheathing fastened
to metal studs as described
in Note 1
Water -resistive
barrier per Florida
Building Code
Section 1404.2
20ga, 3-5/8" X 1-5/8"
Metal C-stud
- LJI HardiePanel,
i SECTION B-B Cempanel,
Nails at 6" O.C. (typ.) Prevail Panel
3/8" Minimum Edge Distance Siding
HARDIEPANEL, CEMPANEL, PREVAIL PANEL SIDING IN
• All installation shall be done in conformance with this No
installation recommendations, and the applicable sectior
■ Metal studs where HardiePanel, Cempanel, Prevail Pan(
Sheathing fastener, as
designed by an Engineer or Architect per the Florida Bui
described in Note 1
N.O.A.
■
[Note 1] 5/8" thick / 5 ply APA rated plywood sheathing ;
Panel fastener, as described in
at panel edges and all intermediate supports using a No.
7— Note 2
bugle head screw
The siding panels shall be installed over 5/8" thick / 5 ply
supported by a minimum 20ga, Nominal 3-5/8" X 1-5/8" 1
O.C.
HardiePanel® Siding
[Note 2] The siding panel fastener shall be a minimum N
long* ribbed bugle head screw (*or screw shall have at k
framing); the fasteners shall be spaced at 6" O.C. at pan
�
fasteners shall be driven through the 5/8" thick / 5 ply AF
rWater -resistive barrier per
studs located at 16" O.C.
Florida Building Code Section .
Fasteners shall have a minimum edge distance of 3/8" a
1404.2
corners.
HARDIEPANEL, CEM
5/8" thick / 5 ply APA rated INSTALLATION DETAILS ry
— plywood sheathing fastened James Hardie BL
to metal studs as described
in Note 1. 0 IL Fontana 10901 E
20ga, 3-5/8" X 1-5/8" Metal C-stud MR1
The wall and soffit frames are to be designed Phone: 909-356-6300 I SIZE FSCM NO
by the Architect or Engineer of Record in �` Fax 909-427-0634 __tA
compliance with the Florida Building Code_ Creator: E. Gonzales SCALE 1/2" = V-0" Date: 9/29
6.00in. �_16.00in.
i
6.00in.
6.00in.
• T
6.00in.
• PRODUCT REVISED /
as complying with the Florida
Building Code
NOA-No. 20-0730.06
Expiration Date 05/01 /2022
By _. -
Miami -Dade Product Control
FRAMING
• NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O.C.
FASTENED WITH 5/8" WAFER HEAD SCREWS (2 PER TOP
AND BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM /
BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PR(
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
■ NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6" OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL, CEh
NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE INSTALLATION DETAILS I
HEAD SCREW
CLADDING
• THE PANEL IS FASTENED WITH NO. 8-18, 0.315" HEAD James Hardie B
DIAMETER X 1-5/8 " LONG CORROSION RESISTANT 10901
RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT Fontan
LEAST 3 FULL THREADS PENETRATING THE METAL Phone: 909-356-6300 SIZE FSCM NO _
FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES Fax 909-427-0634 A
AND INTERMEDIATE STUDS
Creator: E. Gonzales SCALE 1" = 1'-0" Date: 912
Stud Spacings at 16" O.C. WALL LENGTH
BE
}
----- -- ------ _------- - 77--------
I
PRODUCT REVISED
I i
as complying with the Florida
Building Code
4. 1662 •� I
WALL
I
NOA-No. 20-0730.06
.
= +,�� t i
y r•:
HEIGHT
i
Expiration Date05/01/2022
I
By
Miami -bade Product Control
.--•------•--• •-• -r' ----
------- - -....__-..------ ...-------- -------- ----------------
-••---•---•------...---•----
BE
3/4" Minimum Edge Distance Nails at 16" O.C. (typ.)
DETAIL A _ Sheathing fastener, as
i described in Note 1
/f
Siding fastener, as
/ described in Note 2
i
i
1, HardiePlank,
Cemplank, Prevail
Lap Siding
/ Water -resistive barrier
�— per Florida Building
Code Section 1404.2
5/8" thick / 5 ply APA rated
plywood sheathing fastened
in accordance with Florida
Building Code Section
2322.3
2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code_
SEE
DETAIL A
11
Ztr ` 5/8" thick / 5 ply AP
I Ksheathing
rated plywood
in
accordance with
Florida Building Coi
Section 2322.3
Water -resistive
barrier per Florii
Building Code
Section 14042
2" X 4" S-P-F
Wood Studs
Lap Siding
EULC ,
B-B 1-1/4" tall X 5/11
thick starter stril
HARDIEPLANK, CEMPLANK PREVAIL LAP SIDING INSTALLA
• All installation shall be done in conformance with this Notice of
installation recommendations, and the applicable sections of tl-
• Wood studs where HardiePlank, Cemplank, Prevail Lap Siding
Engineer or Architect per the Florida Building Code and the re(
[Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall b
with Florida Building Code Section 2322.3.
Planks shall be applied horizontally commencing from the bolt(
laps at the top of the plank such that the exposure area of earl
■ [Note 2] The siding fastener shall be a 2-1/2" long, 0.223" heal
corrosion -resistant siding nail; The siding is fastened S B-1/4" (
fasteners are driven into wood studs through 5/8" thick / 5 ply /
are placed in the overlapping area approximately 3/4" from the
Vertical joints shall be placed over studs.
• The planks shall be installed over 5/8" thick / 5 ply APA rated F
minimum of 2"X4" S-P-F wood studs spaced a maximum of 16
• Fasteners shall have a minimum edge distance of 3/8".
HARDIEPLANK, CEMPL
INSTALLATION DETAILS M
James Hardie BL
I 10901 E
Fontana
Phone:909-356-6300 3IGE FSCMNO
Fax909-42i-0634 A
Creator: E. Gonzales SCALE 1/2" = 1'-o" Date: 9/29
Fastener Spacing per Florida
Building Code Section 2322.3
�__16 in. OC--�
k
I
i
i
W �'� T
Fastener Spacing per Florida
Building Code Section 2322.3
0.75in
PRODUCT REVISED
as complying with the Florida
Building Code
. NOA-No. 20-0730.06 - — —------
--------------- -.........
.
Expiration Date05/01/2022
By
Miami -Dade Product Control
s8.251n.
—
rr
FRAMING
• NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND
BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM AC
BY THE ARCHITECT OR ENGINEER OF RECORD IN
NOT PART OF THIS APPROVAL (MUST
PROVIDE ALTERNATE PROxj
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
■ NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA
HARDIEPLANK, CEMPL
BUILDING CODE SECTION 2322.3
INSTALLATION DETAILS V1
CLADDING
• PLANKS OVERLAP 1-1/4"
_
James Hardie Bl.
■ THE EXPOSURE IS <_8-1/4"
• THE PLANKS ARE FACE: NAILED WITH 2-1/2" LONG, 0.223"
• � �
10901 E
HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION-
Fontana
RESISTANT SIDING NAILS, PLACED 3/4" UP FROM THE
Phone: 909-356-6300
sVE
FSCM NO
BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION
Fax 909-427-0634
A
Creator: E. Gonzales
SCALE
V = V-0"
Date: 9129
40
Stud Spacing at 16" O.C. WALL LENGTI
-- -- - _ _---------
-------.-----
,,
� I I
"I PRODUCT REVISED
f j as complying with the Florida
Building Code
WALL NOA-No. 20-0730.06
Expiration Date 05101 /2022
—By
MIamFOade Product Cantral
-•- -�' '---------- — - --
i
Bt =
3/4" Minimum Edge Distance
DETAIL A
�r
/f
I
f
1
.��
'p, A 'of:
{CV
f--� L L)
lij4itil
�. - _ ----------------------
� 2$
Nails at 16" O.C. (typ.)
SEE
TAIL A
r
}
SECTIi
B-B
5/8" thick / 5 ply API
rated plywood
sheathing fastened
to metal studs as
described in Note 1
Water -resistive
barrier per Florida
Building Code
Section 1404.2
20ga- 3-5/8" X 1-5/E
t Metal C-stud
HardiePlank,
'Cemplank, Prevail
N,
Lap Siding
1-1/4" tall X 5/16"
thick starter strip
HARDIEPLANK, CEMPLANK, PREVAIL LAP SIQING INSTALLATION
■ All installation shall be done in conformance with this Notice of Acce
1 Sheathing fastener, as recommendations, and the applicable sections of the Florida Buildin
described in Note 1 Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will b
` Engineer or Architect per the Florida Building Code and the requirer
[Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be att-.
Siding fastener, as edges and all intermediate supports using a No.8-18, 0.315" head d
l described in Note 2 " Planks shall be applied horizontally commencing from the bottom cc
the top of the plank such that the exposure area of each plank is <- E
[Note 2] The siding fastener shall be a minimum No. 8-18, 0.315" hi
HardiePlank, screw over metal studs (*or screw shall have at least 3 full threads F
fastened 5 8-1/4" O.C. vertically and 16" O.C. horizontally; fastener:
Cemplank, thick / 5 ply APA rated plywood sheathing, fasteners are placed in tt
Prevail Lap Siding from the bottom edge of the overlapping plank_
■ Vertical joints shall be placed over studs.
Water -resistive The planks shall be installed over 5/8" thick / 5 ply APA rated plywol
~� barrier per Florida 20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a maximum of
Fasteners shall have a minimum edge distance of 3/8 .
Building Code
-- Section 1404.2
5/8" thick / 5 ply APA rated
plywood sheathing fastened to
metal studs as described in
Note 1
20ga, 3-5/8" X 1-5/8" Metal C-stud
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
HARDIEPLANK, CEMPL
INSTALLATION DETAILS W
James Hardie BL
10901 E
Fontana
Phone: 909-356-6300 svuF FSCM NO
Fax 909-427-0634 A
Creator: E. Gonzales SCALE 1 /2" = 1'-0" f Date: 9/29
6.00in.
F
6.0110•in, lI
��---16 in. OC--- .
6.00in.00
1
0.75in
PRODUCT REVISED
as complying with the Florida
Building Code �.
-•---- -• NOA-No. 20-0730.06 ------•- -----------------------
Expiration Date05/01/2022
By :.
Miami -Dade Product Control • ■
----------•------ ------ --- -- ---- ---------�- - — --�_ ..-----
<8.25in. �.
FRAMING
■ NOMINAL 20 GAUGE 3-518" X 1-5/8" STEEL STUDS 16"
O.C. FASTENED WITH 5/8" LONG RIBBED BUGLE HEAD
SCREWS (2 PER TOP AND BOTTOM CONNECTION)
■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM A
BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PRO
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6" OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A
NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE HEAD SCREW HARDIEPLANK, CEMPL
CLADDING INSTALLATION DETAILS N
■ PLANKS OVERLAP 1-1/4"
■ THE EXPOSURE IS _< 8-1/4" James Hardie BI.
■ THE PLANKS ARE FASTENED WITH NO. 8-18, 0.315" , 10901 E
HEAD DIAMETER X 2-1/4" LONG CORROSION- Fontana
RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW
SHALL HAVE AT LEAST 3 FULL THREADS Phone_ 909-35E>-5300 SIZE FscM No
PENETRATING THE METAL FRAMING), PLACED 3/4" UP Fax 909 427-0634 A
FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Creator: E. Gonzales scplF 1" =1'-0" Date: 9/29
WALLLENGTH
Stud Spacing at 16" O.C.
B F--I I
--
.I .E_
i
j
i = I PRODUCT REVISED
j as complying with the Florida t
Building Code 1 I'
NOA-No. 20-0730.06
WALL
HEIGHT': I Expiration Date05/01/2022
j B
Miami -Dade Product Control t
-- y - _ - - - -- - --- - --
DETAIL A
TNails at 4" O.0 (typ.)
3/8" Minimum Edge Distance
SEE
PRODU
DETAIL A
HardieS
-------T_
nonasbe
r ^1
accorda
l
!ti
and mee
1
Building
SOFFITWidth
2" X 4" S-P-F
r'
Wood Studs
4'
DESIGN
HardieSoffit,
Installati
Cemsoffit
Wood S
55ECTIOIV 8-B
51
'fr
HARDIESOFFIT. CEIVISOFFIT PANEL INSTALLATION DETAIL:
'offit fastener, as - All installation shall be done in conformance with this Notice c
lescribed in Note 1 installation recommendations, and the applicable sections of I
Wood studs where HardieSoffit, Cemsoffit will be installed shl
Architect per the Florida Building Code and the requirements
HardieSoffit, Cemsoffit The soffit shall be installed over minimum 2"X4" S-P-F wood:
[Note 1] The soffit fastener shall be a 2" long, 0.223" head di-,
corrosion resistant siding nail; the fasteners shall be spaced s
intermediate studs; the fasteners shall be driven into wood sti
Fasteners shall have a minimum edge distance of 3/8" and a
HARDIESOFFIT,
INSTALLATION DETAILS \6
-F Wood Studs James Hardie Bt
mes are to be 10901 E
itect or
Fontana
i compliance Phone: 909-35&8300 SIZE FSCM NO
ng Code. Fax 909-427-0634 A
Creator: E. Gonzales SCALE 1/2" = 1'-0" Date: 9/25
4.4ain. s� 16.00in.
4.00in.1 .
� PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 20-0730.06
Expiration Date 05/01 /2022
By
Miami -Dade Product Control
. .
r
FRAMING
NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM
CONNECTION)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY
THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE
WITH THE FLORIDA BUILDING CODE
CLADDING
THE SOFFIT IS FASTENED WITH 2" LONG, 0.223" HEAD
DIAMETER, 0.092" SHANK DIAMETER, CORROSION
RESISTANT SIDING NAILS, PLACE NAILS 4" O.C. AT PANEL
EDGES AND INTERMEDIATE STUDS
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM AC
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PRO\
HARDIESOFFIT,
INSTALLATION DETAILS V
James Hardie BI
10901 E
FontanE
Phone: 909-3513-6300 slzE FSCM No
Fax 909-427-0634 A
Creator: E. Gonzales SCALE 1" = V-0" Date: 9/2E
- — WALL LENGTH -
Stud Spacing at 16" O.C.
BF— I
f, --- ---
�:
PRODUCT REVISED
I as complying with the Florida
Building Code
NOA-No. 20-0730.06
WALL j Expiration D��ate05101/2022
IEIGHT ; ' f By Irk -
Miami -Dade Miami -Dade Product Control
I � y
1.- .-..5... _ -.• --- - - •--------
Nails at 6" O.C. (typ.)
3/8" Minimum Edge Distance
DETAIL A
r
f
I
SEE
DETAIL A
Ile I
20ga, 3-518" X 1-5/8"
Meta: C-stud
HardieSoffit,
Cemsoffit
SECTION BBB
E
H
a
tE
C
rf
C
S
V
0
Ir
N
HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DE
• All installation shall be done in conformance with this Nc
installation recommendations, and the applicable sectioi
Soffit fastener, as Metal studs where HardieSoffit, Cemsoffit will be installe
described in Note 1 Architect per the Florida Building Code and the requirerr
The soffit shall be installed over minimum 20ga, Nomina
a maximum of 16" O.C.
HardieSoffit, Cemsoffit [Note 1] The soffit fastener shall be a minimum No. 8-1 f
ribbed bugle head screw (*or screw shall have at least 3
framing);the fasteners shall be spaced at 6" O.C. at pane
fasteners shall be driven into metal studs located at 16"
Fasteners shall have a minimum edge distance of 3/8" a
corners.
20ga, 3-5/8" X 1-5/8" Metal C-stud
The wall and soffit frames are to be
designed by the Architect or Engineer
of Record in compliance with the
Florida Building Code.
Phone: 909-356-6300
Fax 909-427-0634
Creator: E. Gonzales
HARDIESOFFIT,
INSTALLATION DETAILS N
James Hardie BL
10901 E
Fontana
E �-SCM NO
A
SCALE 1/2" = 1'-0" i Date: We
- — - 6.00in.� � �16A0in� �-- —
6.00in.
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 20-0730.06
Expiration Date 05/01 /2022
B rd v
Y
Miami -Dade Product Control
■
FRAMING
■ NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O.C.
FASTENED WITH 5/8" WAFER HEAD SCREWS (2 PER TOP
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM A(
AND BOTTOM CONNECTION)
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROM
■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
CLADDING
HARDIESOFFIT,
THE SOFFIT IS FASTENED WITH NO. 8-18, 0.315" HEAD
INSTALLATION DETAILS N
DIAMETER X 1-1/4 " LONG CORROSION RESISTANT RIBBED
BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3
11011
FULL THREADS PENETRATING THE METAL FRAMING), PLACE
James Hardie BI
SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE
10901 E
STUDS
Fontana
Phone: 909-356-6300 slzE FSCM NO
Fax 909-427-0634 A
Creator: E. Gonzales SCALE
Date: 9/2E