HomeMy WebLinkAboutFlood ElevationLEGAL DESCRIPTION
I I
I POC
I NORTHWEST
I CORNER
CREEKSIDE
I PLAT NO. 3
4O
ti
SET 5/8"
LB 4286
C-
OBI SET 5/8" IR
6] LB 4286 (T'
i0 �[dY
?v `WATER
LEGEND & ABBREVIATIONS
Be DENOTES BEARING BASE
CBS DENOTES CONCRETE BLOCK STRUCTURE
CD DENOTES CHORD DISTANCE
e DENOTES CHORD BEARING
rL DENOTES CENTER LINE
D.E. DENOTES DRAINAGE EASEMENT
F.F.E. DENOTES FINISH FLOOR ELEVATION
FIND DENOTES FOUND
IR/C DENOTES IRON ROD AND CAP
L.B. DENOTES LICENSED BUSINESS
L DENOTES ARC LENGTH
N/D DENOTES NAIL AND DISK
O.S.T. DENOTES OPEN SPACE TRACT
P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER
P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR
R DENOTES RADIUS
R/W DENOTES RIGHT OF WAY
U.E. DENOTES UTILITY EASEMENT
W.M.T. DENOTES WATER MANAGEMENT TRACT
A DENOTES INCLUDED ANGLE
DENOTES DRAINAGE FLOW
og,5 DENOTES PROPOSED ELEVATION
BENCHMARK
SANITARY MANHOLE
SS-34
RIM EL=16.76'
N.A.V.D. 1988
fr86 cI /i 51
I VACANT
SANITARY
RVICE
o S'79-
_s Og
FLOOD(ZONE
0
59.6Z,
PROPOSED
ENTRY
50
PROPOSED
MODEL 4EBB/C
F.F.E.=19.10
GARAGE F.F.E.=18.50
AC PAD
S87'40'51"W X?a_ 137.
49
VACANT
AREA SUMMARY IN SQUARE FEET
SOD:6,147 t
DRIVEWAY/WALKWAY:608 d
PROPERTY ADDRESS
3238 TRINITY CIRCLE, FORT PIERCE, FLORIDA
�� y/024
THOMAS P. KIERNAN DATE
Professional Surveyor & Mapper
Florida Certificate No. 6199
SET 5/8" IR/C
LB 4286 (TYP)
FLOOD ZONE
AE
PROPOSEDCOVERED
7r/�N
LANAI
r'
R=25.00'
A=30"43'22" FIND 4"x4" CM
L=13.41" PRM LB 4286
FND 4"x4" CM
PRM LB 4286
R=190.00,
A=2'30'38"
SET 5/8" IR/C ° L=8.33'
LB 4286 (TYP)
REVISION: MOVED AC PAD GLM 2-19-2020
Being all of Lot 50, according to the unrecorded plat of CREEKSIDE
PLAT NO. 4, St. Lucie County, Florida, more particularly described as
follows;
Commence at a point on the Southerly right-of-way of State Road 70
(Okeechobee Road) (a 200.00 foot wide right-of-way) being the
Northwest corner of CREEKSIDE PLAT NO. 3, as recorded in Plat Book
69, Page 30, Public Records of St. Lucie County, Florida; thence South
56'38'07" East, a distance of 1,776.32 feet to the POINT OF BEGINNING
of the following described parcel;
Thence South 7936'06" East, a distance of 130.00 feet to the intersection
with a non tangent curve concave to the West, having a radius of 355.00
feet, the chord of which bears South 12'54'17" West, 31.05 feet; thence
Southerly along the arc of said curve, a distance of 31.06 feet through a
central angle of 05'00'46" to a point of reverse curve to the left, having a
radius of 25.00 feet and a central angle of 30'43'22"; thence Southerly along
the arc, a distance of 13.41 feet to a point of reverse curve to the right
having a radius of 190.00 feet and a central angle of 02'30'38"; thence
Southerly along the arc, a distance of 8.33 feet; thence South 87'40'51"
West, a distance of 137.79 feet to the intersection with a non tangent curve
concave to the East, having a radius of 25.00 feet, the chord of which bears
North 0612'07" West, 25.97 feet; thence Northeasterly along the arc of said
curve, a distance of 27.31 feet through a central angle of 6235'14" to a
point of reverse curve to the left having a radius of 225.00 feet and a
central angle of 14'41'36"; thence Northerly along the arc, a distance of
57.70 feet to the POINT OF BEGINNING.
Containing 0.208 acres, more or less.
f
GRAPHIC SCALE
20 0 10 20
GENERAL NOTES ( Dr Tsar )
1 l h - 20 e.
1. The last date of field work was 06-14-19
2. Additions or deletions to survey maps or reports by other than the signing party or
parties is prohibited without written consent of the signing party or parties.
3. Reproductions of this map are not valid without the original signature and raised seal of
a Florida Licensed Surveyor and Mapper.
4. Lands shown hereon were not abstracted by this office for rights -of -way, easements of
record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This information
should be obtained through appropriate title verification.
5. All above ground fixed improvements, if any, have been located and shown hereon.
6. Underground foundations and improvements were not located as part of this survey.
7. Flood Note: By graphic plotting only, this property is in Zone X and AE 16.9, according to
the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February
16, 2012. The exact designation can only be determined by an elevation certificate. No
additional search of the public records has been preformed. There may be additional map
Amendments affecting this property.
8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel
and the use of existing field elevation data.
9. The bearings shown hereon are based on Plat information and are referenced to the
Northerly property line of Lot 50 which bears South 79'36'06" East and all bearings are
relative thereto.
10. No easements are shown hereon other than those depicted on the plat. No search of
the public records has been performed to find additional easements that may exist.
11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988.
12. The building setbacks shown hereon, although based on the best available information, are
not certified to and must be verified prior to design or construction.
13. All improvements relating to this plat are either proposed or under construction.
U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008
Federal Emergency Management Agency Expiration Date: November 30, 2022
National Flood Insurance Program
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9. -
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agenticompany, and (3) building owner.
SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
At Building Owner's Name
Policy Number:
D.R. Horton, Inc. (15-141.004.050)
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Company NAIC Number:
Box No.
3238 Trinity Circle
City State ZIP Code
Fort Pierce Florida 34945
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Creekside Plat No. 4, Lot 50; Parcel ID: 2327-502-0058-000-2
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. 27.404861 N Long.80.419894 W Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
AT Building Diagram Number 1 B
A8. For a building with a crawlspace or enclosure(s):
a) Square footage of crawlspace or enclosure(s) 0.00 sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 0
c) Total net area of flood openings in A8.1b 0.00 sq in
d) Engineered flood openings? ❑ Yes ❑x No
A9. For a building with an attached garage:
a) Square footage of attached garage 450.00 sq It
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 0
c) Total net area of flood openings in A9.b 0.00 sq in
d) Engineered flood openings? ❑ Yes Z No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
B2. County Name
B3. State
St. Lucie County, 120285
St. Lucie
Florida
84. Map/Panel
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flo79..
Base Flood Elevation(s)
Number
Date
Effective/
Zone(s(Zone
AO, use Base Flood Depth)
Revised Date
12111GO170
K
02-19-2020
02-19-2020
AE9.
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9:
❑x FIS Profile ❑ FIRM ❑ Community Determined ❑ Other/Source:
811. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No
Designation Date: ❑ CBRS ❑ OPA
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 1 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
3238 Trinity Circle
-
City State ZIP Code
Company NAIC Number
Fort Pierce Florida 34945
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction` ❑x Finished Construction
"A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations — Zones At—A30, AE, AH, A (with BFE), VE, VI—V30, V (with BFE), AR, ARIA, AR/AE, AR/A1—A30, AR/AH, AR/AO.
Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters.
Benchmark Utilized: AF6653 Vertical Datum: NAVD 1988
Indicate elevation datum used for the elevations in items a) through h) below.
❑ NGVD 1929 ❑ NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom Floor (including basement, crawlspace, or enclosure floor) 19.1 ❑x feet ❑ meters
b) Top of the next higher floor N/A ❑x feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑x feet ❑ meters
d) Attached garage (top of slab) 18.3 ❑x feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building 18.9 feet meters
(Describe type of equipment and location in Comments)
f) Lowest adjacent (finished) grade next to building (LAG) 18.2 ❑ feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 18.7 ❑x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including ❑
feet ❑ N/A meters
structural support
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
/ certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false
statement may be punishable by fine orimprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by.a licensed land surveyor? ❑x Yes ❑ No ❑ Check here if attachments.
Certifier's Name License Number
Thomas P. Kiernan 6199
Title
Professional Surveyor
v� �q
XAddress U
f1i
Company Name
Culpepper & Terpening, Inc.
2980 South 25th Street
City State ZIP Code
Fort Pierce Florida 34981
Signature Date Telephone Ext.
�� �� 464-3537 206
(772)
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
Comments (including type of equipment and location, per C2(e), if applicable)
The elevation referenced in Section C2, item e) is: A/C pad at rear of building.
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 2 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
3238 Trinity Circle
City State ZIP Code
Company NAIC Number
Fort Pierce Florida 34945
SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED)
FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request,
complete Sections A, B,and C. For Items El—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only,
enter meters.
Et. Provide elevation information for the following and check the appropriate boxes to show whether theelevation is above or below
the highest adjacent grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement,
crawlspace, or enclosure) is ❑ feet []meters ❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement,
crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG.
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions),
the next higher floor (elevation C2.b in
the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E4. Top of platform of machinery and/or equipment
servicing the building is ❑ feet ❑ meters '❑ above or ❑ below the HAG.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's
floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G.
SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or
community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner or Owner's Authorized Representative's Name
Thomas P. Kiernan
Address City State ZIP Code
2980 South 25th Street Fort Pierce Florida 34981
Signature Date Telephone
(772)464-3537
Comments
❑ Check here if attachments.
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 3 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
3238 Trinity Circle
City State ZIP Code
Company NAIC Number
Fort Pierce Florida 34945
SECTION G - COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete
Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement
used in Items G8-G10. In Puerto Rico only, enter meters.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,
engineer, or architectwho is authorized by law to certify elevation information. (Indicate the source and date of the elevation
data in the Comments area below.)
G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE)
or Zone AO.
G3. ❑ The following information (Items G4-G10) is provided for community floodplain management purposes.
G4. Permit Number
G5. Date Permit Issued
G6. Date Certificate of
Compliance/Occupancy Issued
G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement
G8. Elevationof as -built lowest floor (including basement)
❑ feet ❑ meters
of the building: Datum
G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum
G10. Community's design flood elevation: ❑ feet ❑ meters Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments (including type of equipment and location, per C2(e), if applicable)
❑ Check here if attachments.
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 4 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE See Instructions for Item AS. Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
3238 Trinity Circle
City State ZIP Code
Company NAIC Number
Fort Pierce Florida 34945
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item A6. Identify all photographs with date taken; "Front View" and 'Rear View"; and, if required, 'Right Side View" and
"Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
tad .
1
Photo One
Photo One Caption FrontlRight 1/4 angle 10/14/2020 Clear Photo One
�f
Photo Two
Photo Two Caption Rear/Left 1/4 angle 10/14/2020 Clear Photo Two
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 5 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
3238 Trinity Circle
City State ZIP Code
Company NAIC Number
Fort Pierce Florida 34945
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with: date taken; "Front View" and 'Rear View", and, if required, 'Right Side View" and "Left Side View." When applicable,
photographs must show the foundation with representative examples of the Flood openings or vents, as indicated in Section A8.
Photo Three
Photo Three
Photo Three Caption Clear Photo Three
Photo Four
Photo Four
Photo Four Caption Clear Photo Four
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 6 of 6