HomeMy WebLinkAboutEngineering Ffl � c® y WOLTERS ENGINEERING z I CONSULTING ENGINEERING,DRAFTING,NE G, RE Road N CODE C PLIA IM Beach,FL 33412 ST. L I E OO U NTx%.@61)225-1982 PRODUCT EVALUATIO 0CC �� (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1000 26 GA.GALVALUME 1" NAILSTRIP 16"WIDE ROOF PANEL(FLPA#27499.1) MANUFACTURER: DYNAMIC METALS LLC 340 PIKE ROAD WEST PALM BEACH, FL 33411 To all concerned, The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16"Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel(50 ksi min)that meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.40-450-44 and G3443.14- 450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "NSS16-HZ dated 8/15119, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 3. Supplemental Calculations to support"NSS16-HZ drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 16"(nominal) Fastener Spacing across panel: 16"(at Nailstrip) (Panels overlap with male/female snap fit) Min. Slope: HVHZ: 2712" Non-HVHZ: V2712" (with Lap Sealant) 3"112" (no Lap Sealant in Field Zone) 5MCIALIZING IN IMPACT F,�5I5fmr CUI?TAwx1-5, 5f0rF.rPoN1r5, &WiWnN5 Y..J Field Perimeter&Corner Installation Installation Max. Design Pressure: -116 psf -176 psf Fastener Spacing: 3" From Ends 6" Max. O.C. 3" From Ends 6" Max. O.C. Min Panel Fasteners. #10x1 Panclip Fasteners #10x1 Panclip Fasteners Panel Sealant: Continuous bead of Geocel 2300 or 2320 at Nailstrip side of seam Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ, 1"round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ, 1"round plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be used to prevent galvanic reactions. Minimum Substrate: '/2' (15/32" min)4-ply CDX Plywood or 3/a'solid wood planks S.G. _ .42 min. nailed to 2x rafters spaced 24" max.on center with 8d ring-shank nails spaced 6"on center. Note: The%"wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. SFF-CIALIZING IN IMPACT FE515fANT CLIF AINWALL5, 5fO EFFOW5, $ WINPOW5 4. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 5. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, "Dynamic Metals FL#27499.1, DM Class 1000". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3m party CIA provider, to the dimensions shown on Drawing NSS16-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re-Roofinq: The DM Class 1000 Series 26 Ga. Galvalume 1"Nailstrip 16"Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If you have any questions or need more information concerning this approval, please contact me. Thank you, bV c No 62354 *cottolters FL PE#62354 a Off 20 2020 O' STATE OF �1till111004 i i 5PECIALIZING IN IMPACT I?F515TANT CUI?fAINWPU5, 5T0IVP,ONT5, & WIN19OW5 c r � = 3 s �_ rn 0 F 0 CAI rn � W r o = rn N TT1 01 m ) O 0 n (D LAJ d COW O O ffl N N(D 0 N 7p X O N 1 p�p 7 W O N a C1 co 0 5. 0� (n x to � y O r rr i G. Sni DYNAMIC METALS �a�R PE/�62>5LWM4* ..a4 �•• WGLmm ENGWE6NNG~* * •• 340 PIKE ROAD www.dynomicmetal.net (con/27194) • 152n 20"N STATE OF ;w NnME CHANGE _ 85 19 r I WEST PALM BEACH,FL 33782 FAX:(561)629-7291 ttm PAW 6E11CIi,R 1]ete�,p'.• � \ (561)225-102 (�10 'c�: 15T SU6WiTAL _ 6 16 18 PH:(561)629.7288 EMAIL:info@dynamicmetal.net '�,�s�;. PRINTS ISSUED FOR REV.9 DATE