HomeMy WebLinkAboutEngineering Submittalj Engineering Submittal Cantilever Seawall Walk January 14, 2021 Design Parameters: FBC 2017 & ACI J Job Name-& Location: Bright's Seawall 602 Willows Ave. St. Lucie County, FL OF 7iHE TftEASURE COAST 1.LC. 806 Delaware Ave. (772) 267-1399 Fort Pierce, FL 34946 benchmarkengineeringtc@gmail.com GUILT STRONG LIKE BULL 0; cc c co ..R4� q��il�4u n 1la a ►RIkR�RRR Embeddment Length 72.0 in Hook Back Length 66.0 Instantaneous Deflection DL 450.0' Ib Instantaneous Deflection DL+LL 610.0 lb Length 48.00 in Unit Width 12.00 in Height 8.00 in Uniform Load - Dead Load j 100.22 Lb/ft Uniform load -Live Load ! 40.00 Lb/ft Concrete -Compressive Strength 3,000 psi Concrete Yield Strength 30,000 psi Concrete Modulus 4,350,000 psi Steel Modulus 29,000,000 psi Deflection Rating 1/360 in Top Steel #5 To Count 1.00 each Bottom Steel { #5 Bottom Count 0.00 each Modulus Ratio 7 Beam Inertia 44.19 in4 Neutral Axis 1.57 in Rebar Cover 3.50 in Diameter 0.63 in Top Steel Area a63 in2 Top Steel Spacing 12.00 in Diameter a63 in Bottom Steal Area 0.00 in2 Bottom Steel Spacing WA in Stirups NA lin Max Deflection Allowed 0.13 in Calculated Deflection 0.070 in DK ENru—EERVN(1 1 OF THE TREASURE COAST LLC. 806 Delaware Ave. (772) 267-1399 Fort Pierce, FL 34950 benchmarkensineeringtct:@gMail.com 1/5/21 Re: Permit # 2010-0024 Certification of structural Conformance New Seawall Cap 602 Willows Ave. I , I Dear Saint Lucie County Building Official: Please accept the following response to your plan review comments for the aforementioned project: 1. Comment: Please provide a structural analysis of the existing seawall, provide evidence that it will support the new structure. Response: Based on te Building Official's expressed concern, an additional field inspection was held w1ith the contractor on 1/5/21 to reassess the site conditions. It was determined that due i o the substantial digging by what must be hundreds of land crabs on the land side of the existing seawall, ballast rock and/or 57-stone shall be placed and compacted behind the existing seawall to ensure adequate compaction is available to support the cantileve load of the proposed seawall cap. The stone shall also prevent further land crab excavation to ensure the continued integrity of the proposed seawall cap. I wish to reiterate, per my design, the existing seawall will not support any loading by the prosed seawall cap.'Furthermore, the proposed seawall cap has been adequately reinforced to cantilever over the existing seawall. Thank you for your diligence and please feel free to contact me at (772) 267-1399 with any comments or concerns that you may have. Bowdoin �N��' 4p�N G. NUT �N 0r,c DH: c=US, st=Florida, I=Fart Pierce, o=Bowdoln G. Hutchlnson,.cn=Bowdoln G. Hutchinson c h i n s o nl-^'Date; 2021 01.0515:38.44-05'00' .,/ rr Adobe Acrobat version:2020,013.20074 This item has been electronically signed and sealed by Bowdoin G. Hutchinson, P.E. using a Digital Signature and Date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. COKITRAVCTOR COR