Loading...
HomeMy WebLinkAboutProducts ReviewSLC -_mom _ Library 25T. Repi Unit Dimensions Commercial Rooftop » a«amg Units (Midrange) #m Al n oAxz Ipak .0 ! |\)(t;2 z8L )!_\!§\§§\! /§ -,§ < §! 670500Q / \ // !l_!M,_�L_ ��5���z,_ §((\(()\§(§)Nn \§ F . Furnished « _,;« Inc. zInstalled by Equipment Submittal Page 9za _a SLC - Morningside Library 25T Ipak Repl January 18, 2021 Unit Dimensions - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak TYPICAL PEDESTAL AND BASE DIMENSION DRAWING SHIPS FIELD GASK PEDESTAL ROOFCURB TYPICAL PEDESTALAND BASE PAN DETAIL TYPICAL ROOF CURB AND BASE PAN DETAIL DETAIL DETAIL - FTING LUG V LONG FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 10 of 24 Others SLC - Morningside Library 25T Ipak Repl Unit Dimensions - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak ELECTRICAL/ GENERAL DATA TONS GAS HEATING - PERFORMANCE Model (Tonnage): SAHLF25 (25 Ton) Heating Input: Unit Operating Voltage Range: 414506 Heating Output: Unit Primary Voltage: 460 Capacity Steps: Unit Hertz: 60 Unit Phase: 3 HEATING - GENERAL DATA Gas inlet pressure: (in w.c.) EER: 11.0 EER Gas Pipe Connection Size: IEER: 14.5 EER COMPRESSOR ELECTRIC HEATER Compressor 1 Count: 1.00 Each Electric Heater Kw: Compressor 1 RLA: Compressor 2 Count: 22.20 A 1.00 Each Electric Heater Full Load Amps: Compressor 2 RLA: 19.10 A Compressor 3 Count: Value not available Compressor3 RLA: Value not available SUPPLY FAN MOTOR EXHAUST / RETURN FAN MOTOR SECTION Number of Fans: 2.00 Each Number: Value not available Number of Motors: 1 Horsepower (Each): None Total Horsepower: 15 hp FC Exhaust/Return Fan Motor FLA: Value not available Supply Fan Motor Full Load Amps: 18.00 A Supply Fan Efficiency: 45.53 % CONDENSER FAN MOTOR FILTERS - TYPE Number: 3 Type: Horsepower (each): 1.0 Fumished: YES Condenser Fan Motor Full Load Amps (Total): 5.4 Number: 12 Recommended Sae: 20" #0" x2" PREFILTERS EVAPORATIVE CONDENSER pt Pump Horsepower. N/A Furnished: Pump Full Load Amps: IN Number: Sump Heater Full Load Amps: IN Recommended Sae: Sump Heater kW: N/A REFRIGERANTTYPE Is FINAL FILTERS - TYPE Charge Type: R-410A TYPe: Factory Charge (Circuit kl): 31.31b Furnished: Factory Charge (Circuit k2): Value not available Number: Recommended Sae: PREFILTERS Fumishad: Number: Recommended Sae: Notes: 1. LOAD 1=Current of the largest motor (compressor or fan motor); LOAD 2-Sum of the currents of all remaining motors; LOAD 3 =Current of electric heaters LOAD 4 =Control Power Transformer (20-40 and 24-48 ton units add 3 FL amps for wire sizing formula, 50-75 and 59 - 89 ton units add 6 FL amps) 2. For Electric Hea1 MCA, MOP, RDE values, calculate for both cooling and heating modes. ( When determining LOADS, the compressors do not operate when the unit is in heating mode) (On 70-89 ton single source units, heating Load 4 = 12 amps on 200,230 volt units and 9 amps on 460,575 volt units) 3. If selected Max Over Cur is less than the Min Ch Amp, then select the lowest maximum fuse size which is equal to or larger than the Min Cir Amp, provided the selected fuse size does not exceed 800 amps. 4. If the selected Recommended Dual Element fuse size is greater than the selected Max Over Cur Protection value, then select the Recommended Dual Element fuse size value to equal the Max Over Protection value. 5. Compressor KW at AHRI rating conditions of 80/67-95 6. Refrigerant charge is an approx. value. For a more precise value, see unit nameplate and service instructions. 7. Sump Heater is an optional feature. 8. Total Horsepower is the combined Horsepower for the Supply Fan Motors. FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 11 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Fan Curve - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak c� 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 0 1.5 ~ 1.0 EN Sol mm am 5000 10000 15000 20000 25000 30000 35000 40000 Airflow (cfm) 63Hz 125Hz 250Hz 500Hz 1 kHz 2 kHz 4 kHz 8 kHz Outdoor Noise: 1 1 1 1 1 1 1 1 Supply Duct: 1 1 1 1 1 1 1 -1 Return Duct: -1 -1 -1 -1 -1 -1 -1 -1 FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 12 of 24 Others SLC - Morningside Library 25T Ipak Repl Weight, Clearance & Rigging Diagram - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak CLEARANCE Note: When 2 or more units are to be placed side by side, the distance between the units should be increased to 150%of the recommended single unit clearance. The units should also be staggered to reduce span deflection & assure proper diffusion of exhaust air. CLEARANCE I 96- _ CLEARANCE CENTER OF GRAVITY AND INSTALL WEIGHT X-Y POINTS AIR COOLED DRAWING FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 13 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18. 2021 Weight, Clearance & Rigging Diagram - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak PL 2, X1 PL 4, X2 Center of Gravity X: 13.20 ft Point load X location 1: 4.000 in Center of Gravity Y: 3.87 ff Point load X location 2: 104.000 in Point load X location 3: 199.000 in Point Load 1: 358.2 lb Point load X location 4: 238.000 in Point Load 2: 386.4 lb Point load X location 5: N/A Point Load 3: 514.2 lb Point load X location 6: N/A Point Watl 4: 542.3 lb Point load X location 7: N/A Point Watl 5: 662.3 lb Point load X location 8: N/A Point Watl 6: 690.5 lb Point load Y location 1: 4.000 in Point Load 7: Point Wad 8: 723.1 lb 751.3 lb Point load Y location 2: 87.000 in Total Weight: 4628.3 lb Added Weight 13i 1. Double wall Notes: 1. The actual weight is stamped on the unit nameplate. 2. The weight shown represents the typical unit operating weight for the configuration selected. Estmated at +/- 10% of the nameplate weight. . 3. Add weight to the total unit weight. 4. Design Special weights are not displayed. Any weight added through COD (Custom Order Design) will not be accounted in the +/- 10%estimate 5. When 2 or more units ato be placed side by side, the distance between the units should be creased to 150% of there recommended single unit clearance. The units should also be staggered to reduce span deflection & assure proper diffusion of exhaust air. PL 6, X3 PL 8, X4 PL 3,X2 PL 5, X3 PL 7, X4 CENTER OF GRAVITY AND INSTALL WEIGHT X-Y POINTS AIR COOLED DRAWING FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 14 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak �° WARNING & AVERTISSEMENT A°. ADVERTENCIA HAZARDOUS VOLTAGE! TENSION DANGEREUSE! iVOLTAJE PELIGROSO! DISCONNECTALL ELECTRIC POWER COURIER TOUTES LES TENSIONS ET DESCONECTE TODA LA ENERGIA ELECTRICA, INCLUDING REMOTE DISCONNECTS OUVRIR LES SECTIONNEURSA DISTANCE, INCLUSO LAS DESCONEXIONES REMOTAS Y AND FOLLOW LOCK OUT AND TAG PUIS SUIVRE LES PROCEDURES DE SIGA LOS PROCEDIMIENTOS DE CIERRE Y PROCEDURES BEFORE SERVICING. VERROUILLAGE ET DES ETIOUETTES AVANT ETIOUETADO ANTES DE PROCEDERAL INSURETHATALLMOTOR TOUTE INTERVENTION. VERIFIER OUE TOUS SERVICIO. ASEGURESE DE OUE TODOS CAPACITORS HAVE DISCHARGED LES CONDENSATEURS DES MOTEURS SONT LOS CAPACITORES DEL MOTOR HAVAN STORED VOLTAGE. UNITS WITH DECHARGES. DANS LE CAS D'UNITES DESCARGADO EL VOLTAJE ALMACENADO. VARIABLE SPEED DRIVE, REFER COMPORTANT DES ENTRAINEMENTSA PARA LAS UNIDADES CON EJE DE TO DRIVE INSTRUCTIONS FOR VITESSE VARAIBLE, SE REPORTER AUX DIRECCION DE VELOCIDAD VARIABLE, CAPACITOR DISCHARGE. INSTRUCTIONS DE UENTRAINEMENT POUR CONSULTE LAS INSTRUCCIONES PARA LA DECHARGER LES CONDENSATEURS. DESCARGA DEL CONDENSADOR. FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT NE PAS RESPECTER CES MESURES DE EL NO REALIZAR LO ANTERIORMENTE IN DEATH OR SERIOUS INJURY. PRECAUTION FELT ENTRAINER DES INDICADO, RODER OCASIONAR LA MUERTE BLESSURES GRAVES POUVANTETRE O SERIAS LESIONES PERSONALES. MORTELLES. CAUTION IMPORTANT! USE COPPER CONDUCTORS ONLYI DO NOT ENERGIZE UNIT UNTIL CHECK-OUTAND UNITTERMINALS ARE NOT DESIGNED TO START-UP PROCEDURE HAS ACCEPT OTHER TYPES OF CONDUCTORS. BEEN COMPLETED. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. ATTENTION N'UTILISER QUE DES CONDUCTEURS EN CUIVREI LES BORNES DE UUNITE NE SONT PAS CONCUES POUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. UUTILISATION DE TOUTAUTRE CONDUCTEUR EAnHo PEUT ENDOMMAGER UEQUIPEMENT. SECTONED PRECAUCION DON ENS SECTION IUTILICE UNICAMENTE CONDUCTORES DE COBREI LASTERMINALES DE LA UNIDAD NO ESTAN \ DISENADAS PARAACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO DO LACE, PUEDE OCASIONAR DANO AL EQLIFO. AREA ICE PREFIX LOCATION CODE SHOWNN WHENN 5E UIED ELECTgIC UNIE 0V230V/m HZ� MAIN UNIT CONTROL INSIDE UNIT CONTROL BOX NITB LY INDENSERSECTION3TM HYDRONIC HEAT 39AL lB2119 1 '0.SI5 L3 LI t lz L3 ATINCSECTON spi aLX SELL EXTERNAL FIELD MOUNTED D-CE I Note: I I All wiring and components shown dashed to be supplied and installed by the customer in TI T2 accordance with local electrical codes. 53A IS LINE U L3 _—A L -�N— — _ _ r -- — — FLD = Furnished by Trans, U. S. Inc. / Installed by Equipment Submittal Page 15 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak ,& WARNING 0 AVERTISSEMENT /K ADVERTENCIA HAZARDOUS VOLTAGE! TENSION DANGEREUSEI iVOLTAJE PELIGROSOI DISCONNECTALL ELECTRIC POWER COUPER TOUTES LES TENSIONS ET DESCONECTE TODA LA ENERGIA ELECTRICA, INCLUDING REMOTE DISCONNECTS OUVRIR LES SECTIONNEURSA DISTANCE, INCLUSO LAS DESCONEXIONES REMOTAS Y AND FOLLOW LOCK OUT AND TAG PUIS SUIVRE LES PROCEDURES DE SIGA LOS PROCEDIMIENTOS DE CIERRE Y PROCEDURES BEFORE SERVICING. VERROUILLAGE ET DES ETIQUETTES AVANT ETIQUETADO ANTES DE PROCEDERAL INSURETHATALLMOTOR TOUTE INTERVENTION. VERIFIER QUE TOILS SERVICIO. ASEGURESE DE QUE TODOS CAPACITORS HAVE DISCHARGED LES CONDENSATEURS DES MOTEURS SONT LOS CAPACITORES DEL MOTOR HAVAN STORED VOLTAGE. UNITS WITH DECHARGES. DANS LE CAS D'UNITES DESCARGADO EL VOLTAJE ALMACENADO. VARIABLE SPEED DRIVE, REFER COMPORTANT DES ENTRAINEMENTSA PARA LAS UNIDADES CON EJE DE TO DRIVE INSTRUCTIONS FOR VITESSE VARAIBLE, BE REPORTER AUX DIRECCION DE VELOCIDAD VARIABLE, CAPACITOR DISCHARGE. INSTRUCTIONS DE L'ENTRAINEMENT POUR CONSULTE LAS INSTRUCCIONES PARA LA DECHARGER LES CONDENSATEURS. DESCARGA DEL CONDENSADOR. FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT NE PAS RESPECTER CES MESURES DE EL NO REALIZAR LO ANTERIORMENTE IN DEATH OR SERIOUS INJURY. PRECAUTION PEUT ENTRAINER DES INDICADO, RODER OCASIONAR LA MUERTE BLESSURES GRAVES POUVANTETRE O SERIAS LESIONES PERSONALES. MORTELLES. CAUTION IMPORTANT! USE COPPER CONDUCTORS ONLYI DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND UNITTERMINALS ARE NOT DESIGNED TO START-UP PROCEDURE HAS ACCEPT OTHER TYPES OF CONDUCTORS. BEEN COMPLETED. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. 22 "EAT ATTENTION F �Ieo91E �—wso—; sss'pinosC® r— (, N'UTILISER QUE DES CONDUCTEURS EN CUIVREI No — � , r a } LES BORNES DE UUNITE NE SONT PAS CONCUES POUR RECEVOIR D'AUTRES TYPES I I ^ Tet]�J DE CONDUCTEURS. _T TC L'UTILISATION DE TOUTAUTRE CONDUCTEUR PEUT ENDOMMAGER I-EQUIPEMENT. 3m] aee _ �— a a88 ass, 15 �Jr�fIlI PRECAUCION s 535 500 16 JJ ��� _ s 5a5 5N 1;---- IUTILICE UNICAMENTE CONDUCTORES DE COBRE! I LAS TERMINI LES DE LA UNIDAD NO ESTAN ass 50a 22 1 —1 DISENADAS PARAACEPTAR OTROS TIPOS DE CONDUCTORES. L_ I SI NO LO HACE, PUEDE OCASIONAR DANO AL EQUIPO. 22 REFRIG r NO —ass ' I RE 11�=as]—(1 olAoozlvoc® 25 FAILURE — 1e0z1 — a9'— (.) DEVICE PREFIX LOCATION CODE 22 D ACTIVE NO —50a J I AGNOSTICeJ —05 J AREA LOCATION I I 2a (eO5) l` No C—506 J I I I INSIDE UNDCONT110— 2 CONDENSER SECTION 3 MR HANDLER ®aUPP _J FaeY f 25 FAIL—UR'E _J=50 NC _la'1 UtOalc 28 EATNGEECTIONnON 20 VOC —SRJI �5.-5VOCa za vOC— W5—J — 5VDC I — 11 Iona Note: All wiring and components shown dashed to be �] supplied and installed by the customer in accordance with local elecirical codes. a�stz (Als) 2] FLD = Furnished by Trans, U. S. Inc. / Installed by Equipment Submittal Page 16 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak NOTES: a1 ALL WIRING AND COMPONENTS SHOWN DASHED TO BE SUPPLIED AND INSTALLED BY THE CUSTOMER IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. a CUSTOMER CONNECTIONS- MAIN UNIT CONTROL (CIRCUIT #1) -ARE LOCATED IN THE CONDENSER SECTION FOR 20 THRU 75 TON UNITS. aSEE CUSTOMER CONNECTION WIRE RANGE TABLE FOR ACCEPTABLE WIRE SIZES FOR CONNECTION TO MAIN UNIT TERMINAL BLOCK (1TB1/4TB2) OR DISCONNECT SWITCH (1SW4S15). a4 WIRES TO THE OPTIONAL STEAM AND/OR HOT WATER HEAT VALVE ARE SUPPLIED WITH THE UNIT. WIRE CONNECTIONS TO THE VALVE TO BE MADE BY THE CUSTOMER. aOPTIONAL5U57 REMOTE ZONE TEMP SENSOR IS USED FOR UNOCCUPIED HEAT/COOL TEMP CONTROL SENSING. a7 WHEN 5U69 REMOTE ZONE TEMP SENSOR IS USED, REMOVE 5U58 INTERGRAL ZONE TEMP SENSOR ATTACHED TO TERMINALS S7 AND S2. a8 WIRES USE SHI ELIDED TWISTED PAIR WIRE. aUSE SHIELDED TWISTED PAIR WIRE.WRAP SHIELD$ WITH TAPE TO PREVENT CONTACT WITH GROUND. 10 REMOVE JUMPER (1TB4-15&1TB4-16) AND INSTALL HIGH DUCT TEMP T-$TAT/OR FIELD SUPPLIED DEVICE. 11 REMOVE JUMPER (1T94-17 & 1TB4-18) WHEN FIELD SUPPLIED EXTERNALAUTO/STOP SWITCH (5S67) IS INSTALLED. 12 CHANGEOVER(5K87) AVAILABLE ONLY ON HVDRONIC HEAT UNITS OR MODULATING GAS HEAT UNITS. 13 ALARM OUTPUT SWITCHES ON ANY MANUAL RESET DIAGNOSTIC. 14 OPTIONAL HEAT MODULE AUX. TEMP (5RT16) IS USED FOR MORNING WARM-UP CONTROL ON UNITS WITH HEATING OPTION. 15 TERMINAL BLOCK 1TB17 AND ASSOCIATED WIRING REQUIRED WITH GBAS(1 U51)OPTION. DEMAND LIMIT RELAY (5K89) TO BE PROVIDED BY CUSTOMER. 16 VENTILATION OVERRIDE MODE CONTACTS RATED 12MA@ 24VDC MINIMUM (5K90 - 5K91 - 5K92 - 5K93 - 5K94) TO BE PROVIDED BY CUSTOMER. 17 WIRE NODES 533& 534 REQUIRED WITH BAS/NETWORK COMM MODULE(1 U54) OPTION. USE SHIELDED TWISTED PAIR WIRE. 18 FIELD CONNECTIONS TO DRIVE VAV BOXES FULL OPEN DURING NIGHT SETBACK MODE. 19 15A FUSE REPLACEMENT IS REQUIRED FOR 50 THRU 60 TON - 0.50 "A TRANSFORMER WITH 2O0V - 230V - 460V OR 575V UNIT VOLTAGE. 20A FUSE REPLACEMENT IS REQUIRED FOR 50 THRU 60 TON - 0.50 KVA TRANSFORMER WITH 380V OR 415V UNIT VOLTAGE. 21 CONTACTS RATED 12 MA@ 24VDC MINIMUM. 22 CONNECT TO 24VAC CLASS 2 CIRCUITS ONLY. 29 REMOVE JUMPER WHEN OPTIONAL FIELD SUPPLIED OUTSIDE AIR SENSOR (3RT3) IS INSTALLED AND THE UNIT DOES NOT HAVE ECONOMIZER. 24 FIELD SUPPLIED AND INSTALLED OCCUPIED/UNOCCUPIED CONTACTS (5K86) FOR USE ON UNITS WITHOUT REMOTE PANEL WITH NIGHT SETBACK (5U58). 25 GBAS 0-5V OPTION CONNECTIONS. 26 GBAS 0-10V OPTION CONNECTIONS. 27 FORGBAS INPUTS All-AI4,"GBAS 0-5V'REQUIRES 0-5V VDC AND "GBAS 0-10V" REQUIRES 0-10VDC. 28 'ACTIVE DIAGNOSTICS (BO5)"APPEAR$ WITH BOTH "GBAS 0-5V'AND "GBAS 0-1 OW. 29 SEE FUSE REPLACEMENT TABLE ON VFD PANEL FOR VFD POWER FUSES (F40, F41, F42). 30 SWITCH A53, LOCATED ON THE VFD, MUST BESET TO"U"(OFF). FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 17 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak FUSE REPLACEMENT TABLE CONDENSER FAN FUSE UNIT VOLTAGE 200 230 380 415 460 575 1F1 THRU 1F6 CLASS RKS I TIME DELAY I 25A 25A 15A 15A 15A 15A CONTROL POWER FUSE CONTROL (1 T1) TRANSFORMER RATING 0.25 KVA 0.30 KVA 0.50 KVA 0.75 KVA 1.00 KVA 1.50 KVA 1F7 CLASS CC -TYPE FNO-R 20-30 TON 6.25A 6.25A 10A 40 TON 15A 20A 20A 50-60 TON - - 15A - 20A - 70-75 TON - - - - 15A 20A ELECTRIC HEAT FUSE 4F19 THRU 4F36, 4F46, 47, 48 CLASS K5 60A COMPRESSOR PROTECTION FUSE 1 F44 & 1 F45 TYPE MTH 6A TRANSFORMER CIRCUIT FUSE 1 1F72 THRU 1F74 TYPE FNQ-R 15A VFD PROTECTION FUSES (CLASS'T' FUSES) OPTIONAL SUPPLY VFD 1 F57 - 1 F62, OPTIONAL EXHAUST / RETURN VFD 1 F63-1 F65 BELT DRIVE MOTOR 20-130 UNITS UNIT VOLTAGE FUSE RATING 3 HP 5 HP 7.5 HP 10 HP 15 HP 20 HP 25 HP 30 HP 40 HP 50 HP 200V/60/3 600V 40A 60A BOA 100A 150A 200A 225A 300A 350A N/A 230V/60/3 600V 30A 45A 70A 90A 125A 175A 200A 250A 300A N/A 380V/50/3 600V 15A 30A 45A 50A 90A 100A 125A 150A 200A N/A 415V/50/3 600V 15A 30A 45A SOA 90A 100A 125A 150A 200A N/A 460V/60/3 600V 15A 25A 35A 45A 60A 90A 100A 125A 150A 200A 575V/6013 600V 15A 15A 25A 35A 50A 70A 60A 100A 125A 175A OPTIONAL DIRECT DRIVE MOTOR 20-59 UNITS UNIT VOLTAGE FUSE RATING 3 HP 5 HP 7.5 HP 10 15 HP HP 1K-1.6K RPM 15 HP 1.7K-2.4K RPM 20 HP 25 HP 30 HP 20OV/60/3 600V 40A 60A 80A 100A 150A 150A 200A 225A 300A 230V/60/3 600V 25A 45A 70A 90A 125A 125A 175A 200A 250A 460V/60/3 600V 15A 25A 35A 45A 70A 60A 90A 100A 125A 5]5V/60/3 600V 75A 15A 2M 35A 50A 50A 70A 80A 100A OPTIONAL DIRECTMDIVE MOTOR fi0-89 TON UNIT VOLTAGE FUSE RATING 10HP 15 HP 1K-1.6K RPM 30 HP 30 1K-1.6K 1.7-2.4K RPM HP RPM 40HP SOHP 20py/60/3 600V 125A 175A U 300A 150A 350A N/A 230Vf60/3 600V 95A 150A 250A 250A 300A N/A 460V/60/3 600V 45A 70A 125A 125A 150A 200A 575V/60/3 600V 40A am— 125A 100A 125A 175A CUSTOMER CONNECTION WIRE RANGE NOTES: UNITS WITH MAIN POWER TERMINAL BLOCK (ALL VOLTAGES) UNITS WITH MAIN POWER DISCONNECT SWITCH (ALL VOLTAGES) A. BLOCK SIZE B DISCONNECT SIZE ARE CALCULATED BY SELECTING THE SIZE GREATERTHAN OREQUALTO1.15X (SUM OF UNIT LOADS). SEE UNIT LITERATURE FOR UNIT LOAD VALUES. BLOCK SIZE WIRE QTV CONNECTOR WIRE RANGE DISCONNECT SIZE WIRE OTY CONNECTOR WIRE RANGE 335AMP (1) #6-350 MCM 100AMP (1) #14-1/0 760 AMP (2) #4-500 MCM 250 AMP (1) #4-350 K-11 840 AMP (2) #2-600 MCM 400AMP (1)OR #1-600 K-11 OR (2) #1 -250 K-11 600AMP (2) 250-NO MCM 1000 AMP (3) 3/0 - 500 k MII OPTIONAL CONVENIENCE OUTLET FUSE 200V/60/3 230V/60/3 380V/50/3 415V/50/3 460V/60/3 575V/60/3 1 F55 AND 1 F56 (TIME DELAY TYPE FNQ-R FUSE) 12A 10A WA N/A 5A 4A FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 18 of 24 Others TRANE" Submittal Prepared For: Sold To: Date: January 18, 2021 Customer P.O. Number: Customer Project Number: Job Number: Job Name: SLC - Morningside Library 25T Ipak Repl Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Oty Product 1 Commercial Rooftop Air Conditioning Units (25T Intellipak Repl) Chris Cowling Trane U.S. Inc. 6965 Vista Parkway North, Suite 11 West Palm Beach, FL 33411 Phone: (561) 683-1521 Cell: (561) 683-1521 Fax: (561) 697-8714 The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified. It is the customer's responsibility to obtain such verification. ELECTRONIC SHOP DRAWING REVIEW By: Salas O'Brien Florida, Inc. NO EXCEPTIONS TAKEN Engineer's review is for general conformance with the design concept and contract documents. Markings or comments shall not be construed as relieving the Contractor from compliance with the project plans and specifications, n r departures therefrom. The Contractor r responsible for details and a racy, compliance with the Contract cuments Doand intent, for confirming and correcting all quantities and dimensions, for selecting appropriate fabrication processes, for techniques of assembly, and for performance of work in a safe manner. By: Joseph W. Detig, EI 01126/2021 J:IJOBS146158985121Submittal - 25T Ipak Unit - SLC Morningside Library RTU Repl 1-18-21.doc SLC - Morningside Library 25T Ipak Repl January 18, 2021 Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak ,& WARNING HAZARDOUS VOLTAGE! DISCONNECTALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCKOUT AND TAG PROCEDURES BEFORE SERVICING. INSURE THATALL MOTOR CAPACITORS HAVE DISCHARGED STORED VOLTAGE. UNITS WITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. CAUTION USE COPPER CONDUCTORS ONLVI UNITTERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. ,& AVERTISSEMENT TENSION DANGEREUSEI COUPER TOUTES LES TENSIONS ET OUVRIR LES SECTIONNEURS A DISTANCE, PUIS SUIVRE LES PROCEDURES DE VERROUILLAGE ET DES ETIQUETTES AVANT TOUTE INTERVENTION. VERIFIER QUE TOILS LES CONDENSATEURS DES MOTEURS SONT DECHARGES. DANS LE CAS D'UNITES COMPORTANT DES ENTRAINEMENTSA VITESSE VARAIBLE, BE REPORTER AUX INSTRUCTIONS DE L'ENTRAINEMENT POUR DECHARGER LES CONDENSATEURS. NE PAS RESPECTER CES MESURES DE PRECAUTION PEUT ENTRAINER DES BLESSURES GRAVES POUVANT ETRE MORTELLES. IMPORTANT! DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND START-UP PROCEDURE HAS BEEN COMPLETED. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. ATTENTION N'UTILISER QUE DES CONDUCTEURS EN CUIVREI LES BORNES DE UUNITE NE SONT PAS CONCUES POUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. UUTILISATION DE TOUTAUTRE CONDUCTEUR PEUT ENDOMMAGER I-EQUIPEMENT. PRECAUCION IUTILICE UNICAMENTE CONDUCTORES DE COBREI LAS TERMINI LES DE LA UNIDAD NO ESTAN DISENADAS PARAACEPTAR OTROS TIPOS DE CONDUCTORES. SI NO LO HACE, PUEDE OCASIONAR DANK) AL EQUIPO. DEVICE PREFIX LOCATION CODE AREA LOCATION INSIDE CONDENSER SECTION cr S MR HANDLER SECTON HEATINGEECTON 5 EXTERNAL FIELD MCUWED DEVICE Note: All wiring and companeni5 Shawn dashed to be supplied and installed by the customer in accordance with local elecirical codes. A ADVERTENCIA iVOLTAJE PELIGROSOI DESCONECTE TODA LA ENERGIA ELECTRICA, INCLUSO LAS DESCONEXIONES REMOTAS Y SIGA LOS PROCEDIMIENTOS DE CIERRE V ETIQUETADO ANTES DE PROCEDERAL SERVICIO. ASEGURESE DE QUE TODOS LOS CAPACITORES DEL MOTOR HAVAN DESCARGADO EL VOLTAJE ALMACENADO. PARA LAS UNIDADES CON EJE DE DIRECCION DE VELOCIDAD VARIABLE, CONSULTE LAS INSTRUCCIONES PARA LA DESCARGA DEL CONDENSADOR. EL NO REALIZAR LO ANTERIORMENTE INDICADO, RODER OCASIONAR LA MUERTE O SERIAS LESIONES PERSONALES. MERGE L EXiERNAtNITCH TOP I STOP SWITCH I REs 5OPTION E.El a �1 43 l :tsENR e 41 I 425azd---------� 5u5]� ----- -1T_ 6 L---------- Q MOTE 406 - - Z= Ta,eL_T aD9----- 3 y444 s rvsoRr, -Tr--ose 5rr t 421 ee n I I i I I I - - r " a ri---------------1---J Is _J ZONE ANE TEMP 43] a�ENaDR 66- EM W Fs �I e a69- 2 COMMON 1 1 ccua6Eo 21 1 HEAT7 350oEP UCONT_CTS 24 —ats COOLe 4M — _ 6 Grvo 5u66� ED SYSON9-415�--41]- - - J13( I I �ma--]HEAr I SERVICE IO -416� `-Sa] - J1�1 la) 1 L-414-- ecooL 1]— I_-- RE �o�E II-- - Grvon - II —we-- 9sva. Jvz li Hu `-J- 52 COMM 1*112-418� `416--4- -- J2'1 la) IMODULE24 E 9a� Is, SERVICE VAC 10 - ! L _ aa5 - - J2-21-1 E 5U69 REMOTTEEEL a L EMOTE -EAR1H J2i WmI NSS PANELJI GROUND - FLD = Furnished by Trans, U. S. Inc. / Installed by Equipment Submittal Page 19 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak ,& WARNING 0 AVERTISSEMENT A ADVERTENCIA HAZARDOUS VOLTAGE! TENSION DANGEREUSEI iVOLTAJE PELIGROSOI DISCONNECTALL ELECTRIC POWER COUPER TOUTES LES TENSIONS ET DESCONECTE TODA LA ENERGIA ELECTRICA, INCLUDING REMOTE DISCONNECTS OUVRIR LES SECTIONNEURSA DISTANCE, INCLUSO LAS DESCONEXIONES REMOTAS Y AND FOLLOW LOCK OUT AND TAG PUIS SUIVRE LES PROCEDURES DE SIGA LOS PROCEDIMIENTOS DE CIERRE Y PROCEDURES BEFORE SERVICING. VERROUILLAGE ET DES ETIQUETTES AVANT ETIQUETADO ANTES DE PROCEDERAL INSURETHATALLMOTOR TOUTE INTERVENTION. VERIFIER QUE TOILS SERVICIO. ASEGURESE DE QUE TODOS CAPACITORS HAVE DISCHARGED LES CONDENSATEURS DES MOTEURS SONT LOS CAPACITORES DEL MOTOR HAVAN STORED VOLTAGE. UNITS WITH DECHARGES. DANS LE CAS D'UNITES DESCARGADO EL VOLTAJE ALMACENADO. VARIABLE SPEED DRIVE, REFER COMPORTANT DES ENTRAINEMENTSA PARA LAS UNIDADES CON EJE DE TO DRIVE INSTRUCTIONS FOR VITESSE VARAIBLE, BE REPORTER AUX DIRECCION DE VELOCIDAD VARIABLE, CAPACITOR DISCHARGE. INSTRUCTIONS DE L'ENTRAINEMENT POUR CONSULTE LAS INSTRUCCIONES PARA LA DECHARGER LES CONDENSATEURS. DESCARGA DEL CONDENSADOR. FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT NE PAS RESPECTER CES MESURES DE EL NO REALIZAR LO ANTERIORMENTE IN DEATH OR SERIOUS INJURY. PRECAUTION PEUT ENTRAINER DES INDICADO, RODER OCASIONAR LA MUERTE BLESSURES GRAVES POUVANTETRE O SERIAS LESIONES PERSONALES. MORTELLES. CAUTION IMPORTANT! USE COPPER CONDUCTORS ONLYI DO NOT ENERGIZE UNIT UNTIL CHECK-OUTAND UNITTERMINALSARE NOT DESIGNED TO START-UP PROCEDURE HAS ACCEPT OTHER TYPES OF CONDUCTORS. BEEN COMPLETED. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. LA". IOry ro� sRTts ATTENTION o VERRIDE DU.T VEaur tfi LIMIT 15 MODE CCONrAC15 tfi MODULE �OVE RIDErv� OVERRIDE N'UTILISER QUE DES CONDUCTEURS EN Nm r vl , r vl Iv 1 21 AUxT P I MooOVES.-Ac CUIVREI L = J L J 14 ���a LES BORNES DE UUNITE NE SONT PAS 5 ° °9900 L J ��""� �""�� CONCUES POUR RECEVOIR D'AUTRES TYPES - Sze DE CONDUCTEURS. J L Ia io UUTILISATION DE TOUTAUTRE CONDUCTEUR PEUT ENDOMMAGER I- EQUIPEMENT. 16 I I L I_______I tT _J PRECAUCION I �______I- 39 °)5,3 _T- J I Lso me ,3---- IUTILICEUNICAMENTECONDUCTORESDE COBREI — — — — — — — — — — — 5 535 53n is ---------------- LAS TERMINI ALES DELAUNIDADNOESTAN I ` S S e 527 532 is, DISENADAS PARAACEPTAR OTROS TIPOS DE s 533 t9 — ?� CONDUCTORES. r 9 55o IN SS r ______- I I I SI NO LO HACE, PUEDE OCASIONAR DANO AL EQUIPO. I I I I I I I I I I I I I I I I I I I I I I I I DEVICE PREFIX LOCATION CODE S AREA LOCATION �J� nzR. 1li iz INSIDE UNIT CONTROLaox 2 CONDENSER SECTIONL �--o— J 1fi za �—F L� NTI-O L J �S Z� S MR HANDLER 3� �"� 14 r EATNOSEcnONnoN __E eEcan. c� OrrIO.AL tz sKeT Lam-{ �°—J OUAIRIDE zl C-oNOrncrVEp Ion tfi J SENSOR Note: j EEDEn T" All wiring and companeni3 Shawn dashed to be — — supplied and installed by the customer in accordance with local elecirical codes. DTE sa N_ saa a ROTrv.roMeTER ~r WHT TRACER t� I �-569—UU COMMUNICATIONS FLD = Furnished by Trans, U. S. Inc. / Installed by Equipment Submittal Page 20 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak ,& WARNING HAZARDOUS VOLTAGE! DISCONNECTALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCK OUT AND TAG PROCEDURES BEFORE SERVICING. INSURETHATALLMOTOR CAPACITORS HAVE DISCHARGED STORED VOLTAGE. UNITS WITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. 0 AVERTISSEMENT TENSION DANGEREUSEI COUPER TOUTES LES TENSIONS ET OUVRIR LES SECTIONNEURSA DISTANCE, PUIS SUIVRE LES PROCEDURES DE VERROUILLAGE ET DES ETIQUETTES AVANT TOUTE INTERVENTION. VERIFIER QUE TOILS LES CONDENSATEURS DES MOTEURS SONT DECHARGES. DANS LE CAS D'UNITES COMPORTANT DES ENTRAINEMENTSA VITESSE VARAIBLE, BE REPORTER AUX INSTRUCTIONS DE L'ENTRAINEMENT POUR DECHARGER LES CONDENSATEURS. NE PAS RESPECTER CES MESURES DE PRECAUTION PEUT ENTRAINER DES BLESSURES GRAVES POUVANTETRE MORTELLES. /K ADVERTENCIA iVOLTAJE PELIGROSOI DESCONECTE TODA LA ENERGIA ELECTRICA, INCLUSO LAS DESCONEXIONES REMOTAS Y SIGA LOS PROCEDIMIENTOS DE CIERRE Y ETIQUETADO ANTES DE PROCEDERAL SERVICIO. ASEGURESE DE QUE TODOS LOS CAPACITORES DEL MOTOR HAVAN DESCARGADO EL VOLTAJE ALMACENADO. PARA LAS UNIDADES CON EJE DE DIRECCION DE VELOCIDAD VARIABLE, CONSULTE LAS INSTRUCCIONES PARA LA DESCARGA DEL CONDENSADOR. EL NO REALIZAR LO ANTERIORMENTE INDICADO, RODER OCASIONAR LA MUERTE O SERIAS LESIONES PERSONALES. CAUTION IMPORTANT! USE COPPER CONDUCTORS ONLYI DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND UNITTERMINALS ARE NOT DESIGNED TO START-UP PROCEDURE HAS ACCEPT OTHER TYPES OF CONDUCTORS. BEEN COMPLETED. FAILURE TO DO SO MAY CAUSE DAMAGE TO NO — 614 — NC-615—� THE EQUIPMENT HUMIDIFICATION OM — 616 — ATTENTION N'UTILISER QUE DES CONDUCTEURS EN 3 OALARM UTPUT NO —448 — ON 049 — VAC MAX) ANC CUIVREI 22 124 —450 —� LES BORNES DE L'UNITE NE SONT PAS 18 VAVBox NO — 445 -- CONCUESPOUR RECEVOIRD'AUTRES TYPES RELAY 22 DE CONDUCTEURS. z4 vac Mrx I UUTILISATION DE TOUT AUTRE CONDUCTEUR PEUT ENDOMMAGER I- EQUIPEMENT 1TB16 PRECAUCION r----- ' 445 12 -- J 2 508 446 13 — — IUTILICE UNICAMENTE CONDUCTORES DE FF — — — — — 3 5U9 447 14 — COBREI --- 4 541 448 15 --_ 5 542 LAS TERMINI LES DE LA UNIDAD NO ESTAN a49 --- s 5-03 5017 -- J DISENADAS PARAACEPTAR OTROS TIPOS DE ] 544 81418 ---_� CONDUCTORES.Fr— 8 545 61519 — — — SI NO LO HACE, PUEDE OCASIONAR DANO AL--- EQUIPO. 9 Sa6 61620 --- — 11 613 22 DEVICE PREFIX LOCATION CODE AREA LOCATION INSIDE UNIT CONTROL SON2 SPACE CONDENSER SECTION iUMIDITYSENSOR S AIR HANDLER nO EATNGSECTION 546—NC HEAT MODE ROUTPUT ELAY —545 — coml IHYDRONIC HEAT OR MODULATING 22 5 EXTERNAL FIELD MauNrao DEVICE — 544 — GAS NO HEAT) Note: I � I I---5a3 —NC VO 22 All wiring and companeni8 Shawn dashed to be supplied and installed by the customer in 542 — cc- RELAY — - 541 — NO j OUTPUT accordance with local electrical codes. NC DIRTY 22 _ - — COM FILTER 25 a NO (B., I III — hl o-1D DA01)" FLD = Furnished by Trans, U. S. Inc. / Installed by Equipment Submittal Page 21 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak DANFOSS VARIABLE FREQUENCY DRIVE PROGRAMMING PARAMETERS MENU PARAMETER DESCRIPTION SETTING SET ONLY FOR 1-21 MOTOR POWER APPLICATIONS USING 3HP HIGH EFFICIENCY MOTORS SET ONLY FOR LOAD/MOTOR 1-22 MOTOR VOLTAGE 200/23OV 60HZ 380/415V SOHZ APPLICATIONS 1-24 MOTOR CURRENT SET BASED ON MOTOR NAMEPLATE 1-25 MOTOR NOMINAL SPEED 1800 RPM 1-73 FLYING START ENABLED BRAKES 2-01 DC BRAKE CURRENT 0% 3-15 REFERENCE 1 SOURCE ANALOG INPUT 53 30 REFERENCE/ RAMPS 3-41 RAMP I RAMP UP TIME 30SECONDS 3-42 RAMP I RAMP DOWNTIME 30SECONDS LIMITS/ 4-12 MOTOR SPEED LOW LIMIT 22HZ WARNINGS 4-18 CURRENT LIMIT 100%RATED CURRENT DIGITAL 5-40101 FUNCTION RELAY 1 NO ALARM IN/OUT 5-40111 FUNCTION RELAY RUNNING 14-01 SWITCHING FREQUENCY 4.5KHZ 14-12 FUNCTION AT MAINS DERATE SPECIAL IMBALANCE FUNCTIONS 1420 RESET MODE AUTOMATIC RESET X3 14-60 FUNCTION AT OVER DERATE TEMPERATURE FLD = Furnished by Trane V. S. Inc. / Installed by Equipment Submittal Page 22 o/ 24 Others SLC - Morningside Library 25T Ipak Repl Accessory - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al Qty: 1 Tag(s): 25T Ipak 5/15" BAYSEN119-ZONE SENSOR PROGRAMMABLE SENSOR TEST FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 23 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the 'ob. Product Family - Commercial Rooftop Air Conditioning Units (Midrange) Item Tag(s) Ot Descri Lion Model Number Al 25T Ipak 1 20-75 Ton Packaged Industrial Rooftop S SAHLF2540-00C5DD7E11 B*W*-H* BA--6T-M8--' ----- Field Installed Option Description Part/Ordering Number Programmable zone sensor FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 24 of 24 Others Table Of Contents Product Summary... Commercial Rooftop Air Conditioning Units (Midrange) (Item All) TagData..................................................................................................................................................3 ProductData............................................................................................................................................ 3 PerformanceData.................................................................................................................................... 4 MechanicalSpecifications........................................................................................................................ 5 UnitDimensions....................................................................................................................................... 9 FanCurve.............................................................................................................................................. 12 Weight, Clearance & Rigging Diagram................................................................................................... 13 Accessory.............................................................................................................................................. 15 Field Installed Options - Part/Order Number Summary Commercial Rooftop Air Conditioning Units (Midrange)......................................................................... 24 SLC - Morningside Library 25T Ipak Repl January 18, 2021 Tag Data - Commercial Rooftop Air Conditioning Units (Midrange) (Qtv: 1) Item I Tag(s) Oty I Description Model Number Al 25T Ipak 1 1 20-75 Ton Packaged Industrial Rooftop S SAHLF2540-00C5DD7E11 B`W`-H`BA--6T-M 8- `----` Product Data - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al City: 1 Tag(s): 25T Ipak High efficiency unit DX Cooling only R-410A refrigerant 25 Ton unit 460 Volt-60 Hertz-3 Phase 0-100% Economizer (Motorized Damper) Sloped Stainless Steel Drain Pan Grease Lines / Filter Gauge 2.00" [51 mm] internal Spring isolators MERV 8 High efficiency throwaway filters (1 set) 15 HP FC Fan VAV (DTC) with supply VFD & bypass Programmable zone sensor (Fld) Low ambient damper(s) control cULus Unit disconnect switch with high fault SCCR (65k SCR rating) Motors with internal shaft grounding ring Hinged access doors BACnet communication interface module 0-10 volt Generic B.A.S Module Professionally -applied condenser coil coating Factory Start-up and 1 s' year Parts, Labor & Refrigerant warranty 2nd-5th year Whole Unit Parts warranty Excludes: Curb or Curb adapter (re -use existing), Controls wiring or integration labor, Unit casing coating (cond coil only), Smoke Detectors, Final Filters, Labor warranty, Anything not listed above. FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 3 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Performance Data - Commercial Rooftop Air Conditioning Units (Midrange) Tags 25T I ak Supply airflow cfm 10000 Cooling entering DB F 80.00 Cooling entering WB F 67.00 Ambient DB F 95.00 Cooling leaving coil DB F 57.50 Coolina leaving coil WB F 56.47 Cooling leaving unit DB F 60.62 Cooling leaving unit WB F 57.66 Gross total capacity MBh 331.32 Gross sensible capacity MBh 251.00 Gross latent capacity MBh 80.32 Net total capacity MBh 297.14 Net sensible capacity MBh 216.81 Fan motor heat MBh 34.18 Evaporator face area (sq ft 20.30 Supply duct static pressure in H2O 2.000 Return duct static pressure in H2O 0.500 Component S.P. drop in H2O 0.940 Total static pressure in H2O 3.440 Supply motor bhp (bhp) 11.89 Supply fan rpm (rpm) 1291 Supply fan efficiency % 45.53 System power kW 35.78 EER @ AHRI (EER) 11.0 IEER @ AHRI (EER) 14.5 Minimum circuit am acit A 71.25 Maximum overcurrent protection (A) 90.00 Minimum disconnect switch size (A) 75.00 Recommended dual element A 80.00 Compressor 1 count Each 1.00 Compressor 1 RLA A 22.20 Compressor 2 count Each 1.00 Compressor 2 RLA A 19.10 Supply fan motor FLA A 18.00 Supply motor count 1 Supply fan count Each 2.00 Condenser fan FLA A 5.40 Other FLA A 1.00 R-410A refrigerant charge - circuit 1 Ib 31.3 Installed point load 1 Ib 358.2 Installed point load 2 Ib 386.4 Installed point load 3 Ib 514.2 Installed point load 4 Ib 542.3 Installed point load 5 Ib 662.3 Installed point load 6 Ib 690.5 Installed point load 7 Ib 723.1 Installed point load 8 Ib 751.3 Total installed weight Ib 4628.3 Note: Unit performance based on 10,000 CFM at 80/67 Entering Air Temp and 2.5" ESP. Performance can be re -run at different conditions if desired. FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 4 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 Mechanical Specifications - Commercial Rooftop Air Conditioning Units (Midrange) Item: Al City: 1 Tag(s): 25T Ipak General - R410A Units shall be specifically designed for outdoor rooftop installation on a roof curb and be completely factory assembled and tested, piped, internally wired, fully charged with R-410A compressor oil and shipped in one piece. Units shall be available for direct expansion cooling only, or direct expansion cooling with natural gas, electric, hot water or steam heating. Filters, outside air system, exhaust air system, optional non -fused disconnect switches and all operating and safety controls shall be furnished factory installed. All units shall be cULus approved and factory run tested. Cooling capacity shall be rated in accordance with AHRI Standard 360. All units shall have decals and tags to aid in service and indicate caution areas. Electrical diagrams shall be printed on long life water resistant material and shall ship attached to control panel doors. Casing Exterior panels shall be zinc coated galvanized steel, phosphatized and painted with a slate grey air-dry finish durable enough to withstand a minimum of 672 hours consecutive salt spray application in accordance with standard ASTM 13117. Screws shall be coated with zinc -plus -zinc chromate. Heavy gauge steel hinged access panels with tiebacks to secure door in open position shall provide access to filters and heating sections. Refrigeration components, supply air fan and compressor shall be accessible through removable panels as standard. Unit control panel, filter section, and gas heating section shall be accessible through hinged access panels as standard. Optional Double Wall Construction hinged access doors shall provide access to filters, return/exhaust air, heating and supply fan section. All access doors and panels shall have neoprene gaskets. Interior surfaces or exterior casing members shall have 1/2" Tuf-Skin fiberglass insulation. Unit base shall be watertight with heavy gauge formed load bearing members, formed recess and curb overhang. Unit lifting lugs shall accept chains or cables for rigging. Lifting lugs shall also serve as unit tiedown points. Hinged Access Doors Hinged access doors shall provide easy access to supply fan, filters, exhaust/return fan, and heating section.These access doors shall feature double wall construction with dual density insulation sandwiched between heavy gauge galvanized steel panels for strength and durability Air -Cooled Condenser Coil - R410A Condenser coils shall have all Aluminum Microchannel coils. All coils shall be leak tested at the factory to ensure pressure integrity. The condenser coil is pressure tested to 650psig Subcooling circuit(s) shall be provided as standard. Condenser Fans and Motors All condenser fans shall be vertical discharge, direct drive fans, statically balanced, with aluminum blades and zinc plated steel hubs. Condenser fan motors shall be three-phase motors with permanently lubricated ball bearings, built-in current and thermal overload protection and weathertight slingers over motor bearings. Low Ambient Low ambient dampers shall be provided on condenser fan to allow the unit. Evaporator Coil - R410A Internally enhanced copper tubing of 3/8" or 1/2" O.D. shall be mechanically bonded to heavyduty aluminum fins of configured design. All coils shall be equipped with thermal expansion valves and factory pressure and leak tested. Sloped Stainless Steel Drain Pan The double sloping stainless steel drain pan shall promote runoff of standingwater from condensation inside the unit.Two drain pipes shall be installed through the base channel on each side of the unit.The evaporator drain pan shall be constructed of 14 gauge stainless steel. On units 40 tons and larger, the intermediate drain pan shall be constructed of 16 gauge stainless steel.This shall provide protection in corrosive environments Compressors - R410A The Trane Scroll compressor shall be industrial grade, direct drive 3600 RPM maximum speed scroll type. The motor shall be suction gas-cooled hermetic design. Compressor shall have centrifugal oil pump with dirt separator, oil sight glass, and oil charging valve. Compressor shall also be provided with thermostatic motor winding temperature control to protect against excessive motor temperatures resulting from over -/under -voltage or loss of charge, high and low pressure cutouts, and reset relay. High Efficiency Unit High efficiency unit shall meet ASHRAE 189.1-2011 and CEE Tier 2 Commercial Unitary AC and HP Specification for FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 5 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 utility rebate requirements. Phase Monitor Shall protect 3-phase equipment from phase loss, phase reversal, and low voltage. Any fault condition shall produce a Failure Indicator LED, and send the unit into an emergency stop condition. cULus approved. (Standard on 20-75T units) Supply Fan Supply fan motors shall be either open drip -proof or enclosed fan cooled. All supply fans shall be dynamically balanced in factory. Supply fan shall be test run in unit and shall reach rated rpm. All 60 Hz supply fan motors meet the Energy Independence Security Act of 2007 (EISA). All 50 Hz supply fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Forward Curved Supply Fan Supply fans shall have two double -inlet, forward -curved fans mounted on a common shaft with fixed sheave drive. Fans shall be factory -tested to reach rated rpm before the fan shaft passes through first critical speed. Fan shaft shall be mounted on two grease lubricated ball bearings designed for 200,000 hours average life. Optional extended grease lines shall allow greasing of bearings from unit filter section. Fan motor and fan assembly shall be mounted on common base to allow consistent belt tension with no relative motion between fan and motor shafts. Entire assembly shall be completely isolated from unit and fan board by double deflection rubber -in -shear isolators, or by optional 2" deflection spring isolation. Variable Frequency Drive Unit shall include factory -installed and tested variable frequency drive[s] (VFD) to provide motor speed modulation. The VFD shall receive a 0-10VDC speed signal from the unit controller. The drive will respond to the signal by accelerating or decelerating to maintain the controlling set point (duct static, space pressure, etc). VFD shall also include the following features: 1. Designed, constructed, and tested in accordance with NEMA ICS, NFPA, and IEC standards and housed in a plastic IP20 enclosure. 2. DC link reactors on both the positive and negative rails of the DC bus equal to 3 % impedance to minimize power line harmonics. 3. Full rated output current continuously - 110 % of rated current for 60 seconds and 160 % of rated current for up to 0.5 second while starting. 4. Isolation between the Drive's power circuitry and control circuitry to ensure operator safety and to protect connected electronic control equipment from damage caused by voltage spikes, current surges, and ground loop currents. 5. Audible noise reduction through automatic adjustment of the carrier frequency and frequency avoidance. 6. Rated at 40C with a standard operating range of -10 to 50C (14 to 124F) ambient temperatures and 0 to 95 % relative humidity 7. Self -diagnostics and motor protections such as: cULus listed overload, phase loss, and internal thermal overload 8. Off/Stop and Auto/Start selector switches to start and stop the AC Drive and determine the speed reference a. On units with bypass, an AC Drive/Off/Bypass hand selector switch shall be provided in the unit control box b. In DRIVE mode speed reference shall be provided by a 0-10 VDC analog input 9. A keypad interface which shall be programmable by language and feature multiple lines for easy reading. 10. Controlled and/or accessible points such as AC Drive Start/Stop, speed reference, and fault diagnostics. 11. Meter points such as motor power in HP, motor power in kW, motor kW-hr, motor current, motor voltage, hours run, DC link voltage, thermal load on motor, Thermal load on AC Drive and Heatsink temperature. 12. Troubleshooting features such as: a. AC Drive memory storage of the last 10 faults and related operational data FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 6 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 b. Four simultaneous displays: frequency or speed, run time, output amps and output power c. Keypad which shall display: Reference Signal Value, Output Frequency in Hz or percent, Output Amps, Motor HP, Motor kW, kW 13. Coated circuit boards for protection against corrosive environments 14. Field readable BACnet points to allow for communication of stauts, setpoints and diagnostics to the BAS. Bypass control Shall provide full nominal airflow in the event of drive failure. Internal Shaft Grounding Ring Motors shall have internal bearing protection for use with VFDs. Extended Grease Lines Lines shall be provided to allow greasing of supply and exhaust/return fan bearings through he filter access door. Two-inch Spring Isolators Supply and ExhausVReturn fan (if applicable) assemblies shall be isolated with two-inch nominal deflection to reduce transmission of vibrations 0-100 percent modulating economizer Operated through the primary temperature controls to automatically utilize OA for "free" cooling. Automatically modulated return and CA dampers shall maintain proper temperature in the conditioned space. Economizer shall be equipped with an automatic lockout when the outdoor high ambient temperature is too high for proper cooling. Minimum position control shall be standard and adjustable at the Human Interface Panel or with a remote potentiometer or through the building management system. A spring return motor shall ensure closure of CA dampers during unit shutdown or power interruption. Mechanical cooling shall be available to aid the economizer mode at any ambient. Low leak economizer dampers shall be standard with a leakage rate of 2.5 percent of nominal airflow (400 CFM/ton) at 1" wg. static pressure. Economizer Control with Dry Bulb An outdoor temperature sensor shall be included for comparing the outdoor dry bulb temperature to a locally adjustable temperature setpoint. The setpoint shall be programmed at the human interface, or remote human interface, to determine if outdoor air temperature is suitable for economizer operation. High efficiency throwaway, MERV 8 Shall be two-inch high efficiency MERV 8 media filters with average dust spot efficiency of 25-35 percent and an average arrestance in excess of 90 percent when tested in accordance with ASHRAE 52-76. Differential Pressure Gauge A factory -installed, dial -type, differential pressure gauge shall be piped to both sides of the filter to indicate status. Gauge shall maintain a +/- 5 percent accuracy within operating temperature limits of -20OF to 120°F. Gauge shall be flush -mounted with casing outer wall. Filter sections consisting of pre- and post -filters shall have a gauge for each. Unit Controller DDC microprocessor controls shall be provided to control all unit functions. The control system shall be suitable to control CV or VAV applications. The controls shall be factory -installed and mounted in the main control panel. All factory -installed controls shall be fully commissioned (run tested) at the factory. The unit shall have a Human Interface Panel with a 16 key keypad, a 2 line X 40 character clear English display as standard to provide the operator with full adjustment and display of control data functions. The unit controls shall be used as a stand-alone controller, or as part of a building management system involving multiple units. 1 The unit shall be equipped with a complete microprocessor control system. This system shall consist of temperature and pressure (thermistor and transducer) sensors, printed circuit boards (modules), and a unit mounted Humanlnterface Panel. Modules (boards) shall be individually replaceable for ease of service. All microprocessors, boards and sensors shall be factory mounted, wired and tested. The microprocessor boards shall be stand-alone DDC controls not dependent on communications with an on -site PC or a Building Management Network. The microprocessors shall be equipped with on -board diagnostics, indicating that all hardware, software and interconnecting wiring are in proper operating condition. The modules (boards) shall be protected to prevent RFI and voltage transients from affecting the board's circuits. All field wiring shall be terminated at separate, clearly marked terminal strip. Direct field wiring to the I/O boards is not acceptable. The microprocessor's memory shall be non-volatile EEPROM type requiring FLD = Furnished by Trane U.S. Inc. / Installed by Equipment submittal Page 7 of 24 Others SLC - Morningside Library 25T Ipak Repl January 18, 2021 no battery or capacitive backup, while maintaining all data. 2 Zone sensors shall be available in several combinations with selectable features depending on sensor. 3 The Human Interface Panel's keypad display character format shall be 40 characters x 2 lines. The character font shall be 5 x 7 dot matrix plus cursor. The display shall be Supertwist Liquid Crystal Display (LCD) with blue characters on a ray/green background which provides high visibility and ease of interface. The display format shall be in clear English. Two or three digit coded displays are not acceptable. 4 The keypad shall be equipped with 16 individual touch -sensitive membrane key switches. The switches shall be divided into four separate sections and be password protected from change by unauthorized personnel. The six main menus shall be STATUS, SETPOINTS, DIAGNOSTICS, SETUP, CONFIGURATION and SERVICE MODE. BACnet Communication Interface Module Option shall provide control and monitoring of the rooftop by Tracer SC or a 3rd party building management system utilizing BACnet protocol. Unit Interrupt Rating (High Fault Short Circuit Current Rating-SCCR) An optional 65,000 Amp rating (480V) and 25,000 Amp rating (600V) shall be applied to the unit enclosure using a non -fused circuit breaker for disconnect switch purposes. Fan motors, compressors, and electric heat circuits shall be included with protective devices that will provide the elevated level of fault protection. The unit shall be marked with approved cULus markings and will adhere to cULus regulations. BAYSENS119 Programmable Zone Temperature Sensor Configured as a Variable Air Volume Unit The electronic programmable sensor shall be Auto or Manual changeover with seven day programming. Programmable sensor shall have System Off, Auto and Service LCD indicators as standard. Night setback sensor shall have up to four programs per day which can be individually configured to occupied or unoccupied. Certified AHRI Performance Packaged Rooftop units cooling, heating capacities and efficiencies are rated within the scope of the Air -Conditioning, Heating & Refrigeration Institute (AHRI) Certification Program and display the AHRI Certified® mark as a visual confirmation of conformance to the certification sections of AHRI Standard 340-360 (I-P) and ANSIZ21.47 and 10 CFR Part 431 pertaining to Commercial Warm Air Furnaces. The applications in this catalog specifically excluded from the AHRI certification program are: -Ventilation modes -Heat Recovery. -Units larger than nominal 63 tons in Cooling -Evaporative Condensers FLD = Furnished by Trane U. S. Inc. / Installed by Equipment Submittal Page 8 of 24 Others