HomeMy WebLinkAboutAPPROVED, Certainteed NOA NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 1 of 48
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
CertainTeed LLC.
20 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 20-0110.11 and consists of pages 1 through 48.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 2 of 48
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Type: Wood
Maximum Design Pressure: -127.5 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Dimensions
Test
Specification
Product
Description
All Weather/Empire Base
Sheet
39 3/8" x 65’10”;
Roll weight: 70 lbs.
(2 squares)
ASTM D 4601, Type
II
Asphalt coated, fiberglass reinforced
base sheet.
Flexiglas Base Sheet 39 3/8" x 98’9”; Roll
weight: 90 lbs.
(3 squares)
ASTM D 4601, Type
II
Modified Bitumen coated fiberglass
base sheet.
Flintlastic Base 20 39 3/8" x 49' 6”; Roll
weight: 90 lbs.
(1.5 squares)
ASTM D 6163,
Grade S, Type I
Modified Bitumen coated fiberglass
base sheet.
Flintglas Ply 4 39 3/8" x 164’7”; Roll
weight: 38 lbs.
(5 squares)
ASTM D 2178, Type
IV
UL Type G1
Fiberglass, asphalt impregnated ply sheet.
Flintglas Premium Ply 6 39 3/8" x 164’7”; Roll
weight: 40 lbs.
(5 squares)
ASTM D 2178, Type
VI
UL Type G1
Fiberglass, asphalt impregnated ply
sheet.
Flintlastic STA 39 3/8" x 32’ 10”; Roll
weight: 87 lbs.
(1 square)
ASTM D 6222,
Grade S, Type I
Smooth surfaced APP Modified
Bitumen membrane with non-woven
polyester mat reinforcement for torch
application.
Flintlastic GTA 39 3/8" x 32' 10"; Roll
weight: 105 lbs.
(1 square)
ASTM D 6222,
Grade G, Type I
Granule surfaced APP Modified
Bitumen membrane with non-woven
polyester mat reinforcement for torch
application.
Flintlastic GTA-FR 39 3/8" x 32’ 10”; Roll
weight: 105 lbs.
(1 square)
ASTM D 6222,
Grade G, Type I
Granule surfaced APP Modified
Bitumen membrane with non-woven
polyester mat reinforcement for torch
application.
Flintlastic GMS 39 3/8" x 32’ 10”; Roll
weight: 94 lbs.
(1 square)
ASTM D 6164,
Grade G, Type I
Granule surfaced SBS Modified
Bitumen membrane with non-woven
polyester mat reinforcement for mop
application.
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 3 of 48
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Dimensions
Test
Specification
Product
Description
Flintlastic FR-P 39 3/8" x 32’ 10"; Roll
weight: 101 lbs.
(1 square)
ASTM D 6164,
Grade G, Type I
Fire resistant, granule surfaced SBS
Modified Bitumen Membrane with
non-woven polyester mat
reinforcement for mop application.
Flintlastic Premium FR-P 39 3/8" x 32’ 10"; Roll
weight: 101 lbs.
(1 square)
ASTM D 6164,
Grade G, Type II
Fire resistant, granule surfaced SBS
Modified Bitumen Membrane with
non-woven polyester mat
reinforcement for mop application.
Flintlastic FR Dual Cap 39 3/8" x 32' 10"; Roll
weight: 103 lbs.
(1 square)
ASTM D 6162,
Grade G, Type II
Granule surfaced SBS modified
bitumen membrane with a nonwoven
polyester/fiberglass composite mat
reinforcement for use in cold or mop
applications.
Flintlastic Cap 30 39 3/8" x 32' 10"; Roll
weight: 86 lbs.
(1 square)
ASTM D 6163,
Grade G, Type I
Granule surfaced SBS Modified
Bitumen membrane with fiberglass mat
reinforcement for mop applications.
Flintlastic FR Cap 30 39 3/8" x 32' 10"; Roll
weight: 86 lbs.
(1 square)
ASTM D 6163,
Grade G, Type I
Fire resistant, granule surfaced SBS
Modified Bitumen membrane with
fiberglass mat reinforcement for mop
applications.
Flintlastic FR Cap 30 T 39-3/8” x 32’ 10”; Roll
weight: 100 lbs.
(1 square)
ASTM D 6163,
Grade G, Type I
Granule surfaced SBS Modified
Bitumen membrane with fiberglass mat
reinforcement for torch application.
Flintlastic Base 20 T 39-3/8” x 33’; Roll
Weight: 81 lbs.
(1 square)
ASTM D 6163,
Grade S, Type I
Modified Bitumen, coated fiberglass
base sheet for torch application.
Flintlastic Ultra Poly SMS
Base Sheet
39 3/8" x 32’ 10”; Roll
weight: 90 lbs. (1
squares)
ASTM D 6164,
Grade S, Type I
Smooth surfaced SBS Modified
Bitumen Membrane with non-woven
polyester mat reinforcement for mop or
torched applications.
Glasbase Base Sheet 36" x 98’ 9”; Roll
weight: 75 lbs.
(3 squares)
ASTM D 4601, Type
II
Asphalt coated, fiberglass base sheet.
Flintlastic Poly SMS Base
Sheet
39 3/8" x 64' 3"; Roll
weight: 90 lbs.
(2 squares)
ASTM D 4601,
Grade S, Type II
Modified Bitumen coated polyester
base sheet.
Yosemite Venting Base Sheet 39 3/8" x 32’10”; Roll
weight: 85 lbs.
(1 square)
ASTM D 3909
ASTM D 4897, Type
II
UL Type G3
Mineral Surfaced fiberglass reinforced
buffer sheet.
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 4 of 48
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Dimensions
Test
Specification
Product
Description
Flintlastic APP Base T 39 3/8” x 65’ 4”; Roll
weight: 100 lbs.
(2 squares)
ASTM D 6509 Modified Bitumen coated fiberglass
base sheet.
Flintlastic Ultra Glass SA 39 3/8” x 33’11”; Roll
weight: 73 lbs.
(1 square)
ASTM D 1970
Self-adhering, fiberglass reinforced,
SBS modified bitumen base/ply sheet.
Black Diamond™ Base Sheet 36" x 68’7”; Roll
weight: 78 lbs.
(2 squares)
ASTM D 1970
ASTM D4601 Type I
Self-adhering fiberglass reinforced
modified bitumen base sheet
FlintBond Brush 5 gallon pails ASTM D 3019 Cold applied, SBS polymer modified
asphalt adhesive.
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 5 of 48
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
FlintBoard ISO Polyisocyanurate foam insulation CertainTeed LLC.
FlintBoardH ISO Polyisocyanurate foam insulation CertainTeed LLC.
FlintBoard ISO Cold Polyisocyanurate foam insulation CertainTeed LLC.
ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp.
ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp.
DensDeck Water resistant gypsum board Georgia Pacific Gypsum LLC
DensDeck Prime Water resistant gypsum board Georgia Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels LLC
ENRGY 3 Polyisocyanurate foam insulation Johns Manville Corp.
ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp.
Multi-Max FA-3 Polyisocyanurate foam insulation RMax Operating, LLC
SECUROCK Gypsum-Fiber Roof Board homogenous fiber reinforced USG Corp.
Structodek High Density Fiberboard
Roof Insulation
High Density Wood Fiber Insulation
board
Blue Ridge Fiberboard, Inc.
FescoBoard Expanded perlite and fiber insulation Johns Manville Corp.
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 6 of 48
APPROVED FASTENERS/ADHESIVES:
TABLE 3
Fastener
Number
Product
Name
Product
Description
Dimensions
Manufacturer
(With Current NOA)
1. Trufast #12 DP Fastener Insulation fastener for wood
and steel decks
various Altenloh, Brinch & Co. U.S.,
Inc.
2. Trufast 3” Metal
Insulation Plate
Galvalume steel plate 3” round Altenloh, Brinch & Co. U.S.,
Inc.
3. FlintFast #12 Coated, carbon steel screw various CertainTeed LLC.
4. FlintFast 3” Insulation
Plate
Galvalume AZ50 steel plate 3” round CertainTeed LLC.
5. FlintFast #14 Insulation fastener for wood
and steel decks
various CertainTeed LLC.
6. Simplex MAXX Cap Polymer fastner 1” long Simplex Nails, Inc.
7. #12 Standard Roofgrip Insulation fastener for wood
and steel.
various OMG, Inc.
8. OMG 3” Galvalume Steel
Plate
Galvalume stress plate 3” round OMG, Inc.
9. Trufast #14 HD Fastener Insulation fastener for wood
and steel decks
various Altenloh, Brinch & Co. U.S.,
Inc.
10. OMG Heavy Duty Insulation and membrane
fastener
Various OMG, Inc.
11. 3 in. Round Metal Plate Galvalume AZ50 steel plate 3" round OMG, Inc.
12. AccuTrac Hextra Carbon steel fastener Various OMG, Inc.
13. AccuTrac Plate Galvalume stress plate. 3” square
OMG, Inc.
14. AccuTrac Flat Bottom
Plate
A2-SS aluminized steel plate 3” square OMG, Inc.
15. Millennium One Step
Foamable Adhesive
Polyurethane two component
high rise insulation adhesive
1.5 liters H.B. Fuller Company
16. Millennium One Step
Green Foamable Adhesive
Polyurethane two component
high rise insulation adhesive
1.5 liters H.B. Fuller Company
17. Millennium PG-1 Low
Viscosity Insulation
Adhesive
Polyurethane two component
low rise insulation adhesive
1.5 liters H.B. Fuller Company
18. Insta Stik Quik Set
Insulation
Polyurethane one component
moisture curing adhesive
It is supplied
in pressurized
cylinders with
a net weight
of 23 lbs.,
with a total
unit weight of
30 lbs.
The Dow Chemical Company
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 7 of 48
APPROVED FASTENERS/ADHESIVES:
TABLE 3
Fastener
Number
Product
Name
Product
Description
Dimensions
Manufacturer
(With Current NOA)
19. OMG OlyBond 500
Adhesive
Spray polyurethane foam
insulation adhesive
10 gal. bag-in-
box set and
1.5 liters
SpotShot
cartridge
OMG, Inc.
20. OMG OlyBond 500 Green
Adhesive
Spray polyurethane foam
insulation adhesive
10 gal. bag-in-
box set and
1.5 liters
SpotShot
cartridge
OMG, Inc.
APPROVED SURFACING/COATING OPTIONS:
TABLE 4
Chosen components must be applied according to manufacturer’s application instructions. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
System Number Manufacturer Application
1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at
60 lbs/sq.
2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60
lbs/sq.
3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
4. CertainTeed LLC.
FlintCoat A-150 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq.
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 8 of 48
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date
Factory Mutual Research Corp. FM 4470 3Y8A1.AM 03/23/96
FM 4470 0D3A3.AM 04/04/97
FM 4470 1D7A4.AM 11/09/98
FM 4470 2D0A0.AM 12/23/98
FM 4470 3024311 11/01/06
FM 4470 3031350 09/27/07
FM 4470 3036182 07/31/09
FM 4470 3039046 06/15/10
FM 4470 3048520 09/19/13
Underwriters Laboratories, Inc. UL 790 R11656 01/11/13
United States Testing Company ASTM D 5147 97-457-2R 12/02/87
ASTM D 5147 97-457-4 06/03/88
Momentum Technologies, Inc. ASTM D 6164 AX31G8F 06/05/09
Trinity|ERD TAS 114 (J) 3507.08.99-1 04/18/01
TAS 114 (J) 3504.06.01-1 06/05/01
TAS 114 3521.07.04 07/29/04
TAS 114 3533.01.06 01/06/06
TAS 114 (H) Letter 04/05/06
TAS 117 (B) 3503.10.06 10/10/06
TAS 117 (B) O6490.04.07-R1 06/27/07
TAS 117 (B) / ASTM D 6862 C8500SC.11.07 11/30/07
FM 4470, TAS 114, FM 4470,
TAS 114 (J)
C8370.08.08-R1 10/05/09
TAS 114 (H), TAS 117 (B), TAS
114 (J)
C30560.06.10 06/10/10
FM 4470, TAS 114 C32830.07.10 07/20/10
ASTM D 6164 / D 4798 C31410.01.11-2 01/10/11
TAS 117 B C35500.02.11 02/09/11
FM 4470 (K) / TAS 114 (J) 03515.07.03-1-R1 06/27/12
ASTM D 1876, TAS 114 (H),
TAS 117 (B)
C42110.08.12 08/13/12
FM 4474 / TAS 114 C39670.08.12 08/20/12
ASTM D 4601 C40050.09.12-1 09/28/12
ASTM D 1970 C40050.09.12-2 09/28/12
ASTM D 5147 / D 4798 C31410.10.10-R1 11/01/12
ASTM D 5147 / D 4798 C31410.01.11-1-R1 11/01/12
ASTM D 4798 C31410.01.11-2A-R1 02/21/13
ASTM D 4798 C31410.12.13 12/05/13
ASTM D 6222 C40050.12.13-R1 12/31/13
TAS 117, TAS 114 C30310.12.09-R1 03/07/14
ASTM D 2178 C47250.03.14 03/26/14
ASTM D 1876, TAS 114 (H),
FM 4474
C45620.03.14 03/27/14
ASTM D4601 CTR-SC8740.04.15-R2 04/21/15
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 9 of 48
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date
ASTM D 1876, TAS 114 (H),
FM 4474
C47320.03.14-R1 04/01/15
ASTM D 1876 C35460.05.11-R1 05/20/15
FM 4474 (D) / UL 1897 / TAS
114 (J)
CTR-SC10420.01.16 01/25/16
FM 4474 / TAS 114 (J) CTR-SC9175.09.16-2 09/06/16
FM 4470 (K) / UL 1897 / TAS
114 (J)
CTR-SC11590.08.16-
R1
09/06/16
ASTM D 4601-04 (2012), Type II CTR-SC11145.09.16-
3C
09/19/16
ASTM D 4601-04 (2012), Type II CTR-SC11145.09.16-
3A
09/19/16
ASTM D 6163 CTR-SC11145.09.16-
5A
09/19/16
ASTM D 6222 CTR-SC11145.09.16-
7A
09/19/16
PRI Construction Materials ASTM D 6163 CTC-056-02-01 08/25/10
Technologies LLC ASTM D 6163 CTC-066-02-01 08/09/11
ASTM D 6222 CTC-071-02-01 08/08/11
ASTM D 6164 / D 4798 CTC-093-02-01 08/09/11
ASTM D 4601 CTC-126-02-01 03/12/12
ASTM D 2178 CTC-123-02-01 03/13/12
ASTM D 4601 CTC-127-02-01 03/13/12
ASTM D 6163 CTC-128-02-01 06/11/12
ASTM D 6163 CTC-129-02-01 06/11/12
ASTM D 6164 CTC-132-02-01 06/11/12
ASTM D 6164 CTC-161-02-01 05/09/13
ASTM D 6162 CTC-183-02-01 10/02/13
ASTM D 6164 CTC-190-02-01 12/02/13
ASTM D 1970 CTC-199-02-01 01/22/14
ASTM D 6163 CTC 319-02-01 08/22/17
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 10 of 48
APPROVED ASSEMBLIES:
Membrane Type:APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6” o.c. at wood
joists spaced maximum 24” o.c.
System Type A(1): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, Multi-Max FA-3, ENRGY 3, H-Shield,
FlintBoardH ISO
Minimum 1.5” thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of
approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet:One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to the
insulated substrate.
Ply Sheet:
(Optional)
One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS, Glasbase Base Sheet,
Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base or one or more plies of
Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black
Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA or Flintlastic
APP Base T torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P,
Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T
torch adhered.
Or
One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 11 of 48
(Optional)
Maximum Design
Pressure:
-52.5 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 12 of 48
Membrane Type: SBS Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type A(2): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and
approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, ENRGY 3, ENRGY 3 25 PSI, H-Shield,
FlintBoardH ISO
Minimum 1.5” thick N/A N/A
FescoBoard
Minimum ¾” thick N/A N/A
Structodek High Density Fiberboard Roof Insulation
Minimum ½” thick N/A N/A
DensDeck, DensDeck Prime
Minimum ¼” thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of
approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet
adhered to the insulated substrate in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 13 of 48
Ply Sheet:
(Optional)
One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or
one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic
Ultra Poly SMS Base Sheet torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium
FR-P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base/ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic
FR Cap 30 T torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 14 of 48
Membrane Type:APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with 8d ring shank nails spaced 6” o.c. at wood
joists spaced maximum 24” o. c.
System Type A(3):
Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet, Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, Multi-Max FA-3, ENRGY 3, H-Shield,
FlintBoardH ISO
Minimum 1.5” thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of
approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet:One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to the
insulated substrate.
Ply Sheet:
(Optional)
One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA
or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-60 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 15 of 48
Membrane Type:
SBS Modified
Deck Type 1I: Wood, Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with 8d ring shank nails spaced 6” o.c. at wood
joists spaced maximum 24” o. c.
System Type A(4):
Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved
tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, ENRGY 3, ENRGY 3 25 PSI, H-Shield,
FlintBoardH ISO
Minimum 1.5” thick N/A N/A
FescoBoard
Minimum ¾” thick N/A N/A
Structodek High Density Fiberboard Roof Insulation
Minimum ½” thick N/A N/A
DensDeck, DensDeck Prime
Minimum ¼” thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of
approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet:One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered
to the insulated substrate in a full mopping of approved asphalt applied within the EVT range
and at a rate of 20-40 lbs./sq.
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 16 of 48
Ply Sheet:
(Optional)
One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or
one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a
full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or
one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic
Ultra Poly SMS Base Sheet torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P,
Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T
torch adhered to base/ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-60 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 17 of 48
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater CDX plywood or wood plan attached with #8 screws spaced 6” o.c. at wood
joists spaced maximum 24” o.c.
System Type B(1): Base layer of insulation mechanically fastened, top layer adhered with approved adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardH ISO
Minimum 1.5” thick 1, 3 1:1.33 ft2
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening
details).
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardH ISO
Minimum 1.5” thick N/A N/A
Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium One
Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive in 3/4” – 1” wide beads
spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self-adhered to the
insulated substrate.
Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR, torch adhered to the ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-67.5 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 18 of 48
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8 screws spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type B(2): Base layer of insulation mechanically fastened, top layer adhered with approved adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardH ISO
Minimum 1.5” thick 1, 3 1:1.33 ft2
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening
details).
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum 1/4” thick N/A N/A
Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium One
Step Green Foamable Adhesive, Millennium PG-1 Low Viscosity Insulation Adhesive, Insta-Stik Quik Set
Insulation Adhesive, OMG OlyBond 500 Adhesive or OMG OlyBond 500 Green Adhesive in 3/4” – 1” wide beads
spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the insulated substrate.
Ply Sheet:
(Optional)
One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR, torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-90 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 19 of 48
Membrane Type: SBS/APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank
nails spaced 6” o.c. at wood joists spaced maximum 24” o.c.
System Type C(1): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold
Minimum 1.5” thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold
Minimum 1.5” thick 2 with 9 or 4 with 5 1:1.6 ft2
Note: Top insulation layer shall be mechanically attached using the fastener density listed above. The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in
compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self-adhered to the
insulated substrate.
Ply Sheet:
(Optional)
One ply of Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T, Flintlastic APP Base T
or Flintlastic STA torch adhered to the base sheet.
Membrane: Flintlastic FR Cap 30 T, Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply
sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 20 of 48
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8 screws spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type C(2): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardH ISO
Minimum 1.5” thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum 1/4” thick 1, 3 1:1.33 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the insulated substrate.
Ply Sheet:
(Optional)
One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR, torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-67.5 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 21 of 48
Membrane Type: APP Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8 screws spaced 6” o.c. at wood
joists spaced maximum 24” o.c.
System Type C(3): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardH ISO
Minimum 1.5” thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, ACFoam-III, FlintBoard ISO, FlintBoard ISO Cold, H-Shield, FlintBoardH ISO
Minimum 1.5” thick 1, 3 1:1.33 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal
resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load
requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self-adhered to the
insulated substrate.
Ply Sheet: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR, torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-75.0 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 22 of 48
Membrane Type: SBS Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank nails
spaced 6” o.c. at wood joists spaced maximum 24” o.c.
System Type D(1): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Any Approved Polyisocyanurate Listed in Table 2
Minimum 1.5” thick N/A N/A
Note: Insulation layer shall have preliminary attachment, prior to the installation of the base sheet, at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and
four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base
sheet shall be simultaneously fastened. See base sheet below for fasteners and density.
Base Sheet: One ply of Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Yosemite Venting
Base Sheet, Flintlastic Poly SMS Base Sheet and Flintlastic Ultra Poly SMS Base Sheet,
mechanically attached as described below.
Fastening #1: Trufast #12 DP Fasteners or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation
Plates, FlintFast #12 fasteners or FlintFast #14 fasteners with FlintFast 3” Insulation Plates
spaced 8” o.c. at the 4” wide laps and 8” o.c. in three, equally spaced staggered center rows.
Ply Sheet:
(Optional)
One ply of Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly
SMS Base Sheet applied in FlintBond Brush at a rate of 1.0 – 1.5 gal/sq to the base sheet.
Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-
P, Flintlastic Premium FR-P or Flintlastic GMS applied in FlintBond Brush at a rate of 1.0 –
1.5 gal/sq to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 23 of 48
Membrane Type: SBS Modified
Deck Type 1I: Wood, Insulated
Deck Description: 15/32" or greater APA rated plywood or wood plank attached with #10 wood screws spaced 6”
o.c. at wood joists spaced maximum 24” o.c.
System Type D(2): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Any Approved Polyisocyanurate Listed in Table 2
Minimum 1.5” thick N/A N/A
Note: Insulation layer shall have preliminary attachment, prior to the installation of the base sheet, at an
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and
four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base
sheet shall be simultaneously fastened. See base sheet below for fasteners and density.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base
Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic
Ultra Poly SMS Base Sheet, mechanically attached as described below.
Fastening #1: Fastened with Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plates or FlintFast #14
Fasteners with FlintFast 3” Insulation Plates spaced 8” o.c. at the 4” wide laps and 8” o.c. in
three, equally spaced staggered center rows.
Ply Sheet
(Optional):
One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet
adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet,
Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS
Base torch applied to base sheet or one ply of Black Diamond Base Sheet or Flintlastic Ultra
Glass SA self-adhered to the base sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-97.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 24 of 48
Membrane Type:
SBS Modified
Deck Type 1: Wood, Non-insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with 8d ring shank nails spaced 6” o.c at
wood joists spaced maximum 24” o.c.
System Type E(1):
Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet
mechanically attached as detailed below.
Fastening #1: Fastened with Simplex MAXX Cap fasteners spaced 9” o.c. in the 2” side lap and 12” o.c. in
two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P,
Flintlastic Premium FR-P or Flintlastic GMS adhered to the base sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR
Cap 30 T, torch-applied to base sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf (See General Limitation #9)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 25 of 48
Membrane Type:
APP Modified
Deck Type 1: Wood, Non-insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with 8d ring shank nails spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(2):
Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Flintlastic APP Base T mechanically attached as detailed below.
Fastening #1: Fastened with Simplex MAXX Cap fasteners spaced 9” o.c. in the 2” side lap and 12” o.c. in
two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium
FR-P or Flintlastic GMS adhered to the base sheet with approved mopping asphalt applied
within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR Cap 30 T, torch-
applied to base sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf (See General Limitation #9)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 26 of 48
Membrane Type:
APP Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(3): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet:
(Optional)
One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA
or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 27 of 48
Membrane Type:
SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(4): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet:
(Optional)
One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic Ultra
Poly SMS Base Sheet torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P,
Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T
torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 28 of 48
Membrane Type:
SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #8d ring shank nails spaced 6” o.c.
at wood joists spaced 24” o.c.
System Type E(5): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet or Yosemite Venting Base Sheet, mechanically attached as
described below.
Fastening #1: Fastened with FBC HVHZ nails and tin caps spaced 6” o.c. at the 3” lap and 6” o.c. in four,
equally spaced staggered center rows.
Ply Sheet:
(Optional)
One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic
Ultra Poly SMS Base Sheet, torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P,
Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic
FR Cap 30 T torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 29 of 48
Membrane Type: SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater APA rated CDX plywood or wood plank attached with 8d ring shank nails
spaced 6” o.c. at wood joists spaced maximum 24” o.c.
System Type E(6): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Yosemite Venting
Base, Flintlastic Poly SMS Base and Flintlastic Ultra Poly SMS Base, mechanically attached as
described below.
Fastening #1: Trufast #12 DP Fasteners or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plates,
FlintFast #12 fasteners or FlintFast #14 fasteners with FlintFast 3” Insulation Plates spaced 8”
o.c. at the 4” wide laps and 8” o.c. in three, equally spaced staggered center rows.
Ply Sheet
(Optional):
One ply of Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS
Base Sheet applied in FlintBond Brush at a rate of 1.0 – 1.5 gal/sq. to the base sheet.
Membrane: One ply of Flintlastic Cap 30, Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P,
Flintlastic Premium FR-P or Flintlastic GMS applied in FlintBond Brush at a rate of 1.0 – 1.5
gal/sq to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 30 of 48
Membrane Type:
APP Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with 8d ring shank nails spaced 4” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(7): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet:
(Optional)
One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more Flintglas Ply 4 or Flintlgas Premium Ply 6 adhered to the base sheet in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of
Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA or
Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-60 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 31 of 48
Membrane Type:
SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with 8d ring shank nails spaced 4” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(8): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet:
(Optional)
One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase
Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic Ultra
Poly SMS Base Sheet torch adhered.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P,
Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T
torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-60 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 32 of 48
Membrane Type: SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with #8 wood screws spaced 6” o.c. at wood
joists spaced at maximum 24” o.c.
System Type E(9): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet:
(Optional)
One or more plies of Glasbase Base Sheet, loose laid.
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet,
mechanically attached as described below.
Fastening #1: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6” o.c. at the 3” lap
and 6” o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self-adhered to the base
sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T
torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-60 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 33 of 48
Membrane Type: APP Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with #8 wood screws spaced 6” o.c. at wood
joists spaced maximum 24” o.c.
System Type E(10): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet:
(Optional)
One or more plies of Glasbase Base Sheet, loose laid.
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet,
mechanically attached as described below.
Fastening #1: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6” o.c. at the 3” lap
and 6” o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self-adhered to the base
sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-60 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 34 of 48
Membrane Type: SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6”o.c. at wood
joists spaced maximum 24” o.c.
System Type E(11): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet:
(Optional)
One or more plies of Glasbase Base Sheet, loose laid.
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet,
mechanically attached as described below.
Fastening #1: OMG #12 Standard Roofgrip fasteners with OMG 3” Galvanized Steel Plates or AccuTrac
Plates or Trufast #12 DP fasteners with Trufast 3” Metal Insulation Plates or Flintfast #12
fasteners with Flintfast 3” Insulation Plates spaced 7” o.c. at the 4” wide laps and 7” o.c. in two,
equally spaced staggered center rows.
Ply Sheet: One ply of Flintlastic Ultra Glass SA, self-adhered to the base sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T
torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-67.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 35 of 48
Membrane Type: SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater APA rated plywood or wood plank attached with #8 screws spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(12): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base
Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic
Ultra Poly SMS Base Sheet, mechanically attached as described below.
Fastening #1: Cap nails: 1” diameter, 0.032” thick metal cap with 0.120” shank diameter, annular ring shank
nails spaced 6” o.c. at the 4” wide laps and 6” o.c. in five, equally spaced staggered center rows.
Ply Sheet
(Optional):
One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet
adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet,
Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS
Base torch applied to base sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-67.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 36 of 48
Membrane Type: SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with #8 wood screws spaced 6” o.c. at wood
joists spaced maximum 24” o.c.
System Type E(13): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet or All Weather/Empire Base Sheet, mechanically attached as described below.
Fastening #1: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6” o.c. at the 3” lap and 6
o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to the base
sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30
T torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-82.5 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 37 of 48
Membrane Type: APP Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with #8 wood screws spaced 6” o.c. at wood
joists spaced maximum 24” o.c.
System Type E(14): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Sheet or All Weather/Empire Base Sheet, mechanically attached as described below.
Fastening #1: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6” o.c. at the 3” lap and 3
o.c. in four, equally spaced staggered center rows.
Ply Sheet: One ply of Black Diamond Base Sheet, self-adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-82.5 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 38 of 48
Membrane Type:
SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(15): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet
mechanically fastened with Simplex MAXX Cap fasteners spaced 6” o.c. in the 2” side lap and
6” o.c. in two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium
FR-P, Flintlastic Cap 30 or Flintlastic GMS adhered to the base sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR
Cap 30 T, torch-applied to base sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-90 psf. (See General Limitation #9)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 39 of 48
Membrane Type:
APP Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(16): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners
spaced 6” o.c. in the 2” side lap and 6” o.c. in two evenly divided, staggered rows in the center
of the sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR, torch-applied to the base sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-90 psf. (See General Limitation #9)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 40 of 48
Membrane Type:
SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(17): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic
Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as
described below.
Fastening #1: Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3” Metal
Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac
Hextra with AccuTrac Flat Bottom plates, FlintFast #12 fasteners or FlintFast #14 fasteners with
FlintFast 3” Insulation Plates spaced 6” o.c. at the 4” lap and 6” o.c. in three, equally spaced
staggered center rows.
Ply Sheet:
(Optional)
One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a
full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or
one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch
applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P,
Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic
FR Cap 30 T torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-97.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 41 of 48
Membrane Type: SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater APA rated plywood or wood plank attached with #10 wood screws spaced
6”o.c. at wood joists spaced maximum 24” o.c.
System Type E(18): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, All Weather/Empire Base
Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic
Ultra Poly SMS Base Sheet, mechanically attached as described below.
Fastening #1: Fastened with Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plates or FlintFast #14
Fasteners with FlintFast 3” Insulation Plates spaced 8” o.c. at the 4” wide laps and 8” o.c. in
three, equally spaced staggered center rows.
Ply Sheet
(Optional):
One ply of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet
adhered to base sheet in a full mopping of approved asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq. or one ply of Glasbase Base Sheet, All Weather/Empire Base Sheet,
Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Base 20 T or Flintlastic Ultra Poly SMS
Base torch applied to base sheet or one ply of Black Diamond Base Sheet or Flintlastic Ultra
Glass SA self-adhered to base sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved
mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of
Flintlastic FR Cap 30 T torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-97.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 42 of 48
Membrane Type:
SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(19): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet
mechanically fastened with Simplex MAXX Cap fasteners spaced 6” o.c. in the 2” side lap and
6” o.c. in three evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium
FR-P, Flintlastic Cap 30 or Flintlastic GMS adhered to the base sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR
Cap 30 T, torch-applied.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-105 psf. (See General Limitation #9)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 43 of 48
Membrane Type:
APP Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4”o.c. at
wood joists spaced maximum 24” o.c.
System Type E(20): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners
spaced 6” o.c. in the 2” side lap and 6” o.c. in three evenly divided, staggered rows in the center
of the sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR, torch-applied to the base sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-105 psf. (See General Limitation #9)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 44 of 48
Membrane Type: SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with #8 wood screws spaced 6” o.c. at wood
joists spaced maximum 24” o.c.
System Type E(21): Base sheet mechanically fastened
All General and System Limitations apply.
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet,
mechanically attached as described below.
Fastening #1: Base sheet shall be fastened with OMG 12 Standard Roofgrip fasteners with OMG 3 in. Round
Metal Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3” Metal Insulation
Plates or FlintFast #12 Fasteners with FlintFast 3” Insulation Plates spaced 7” o.c. at the 4” lap
and 7 o.c. in three, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered to the base
sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T
torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-105.0 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 45 of 48
Membrane Type: SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with #8 wood screws spaced 6” o.c. at wood
joists spaced maximum 24” o.c.
System Type E(22): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet:
(Optional)
One ply of Glasbase Base Sheet, loose laid.
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet,
Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet,
mechanically attached as described below.
Fastening #1: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4” o.c. at the 3” lap and
4” o.c. in four, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self-adhered to the base
sheet.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-
P, Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T
torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-105 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 46 of 48
Membrane Type: APP Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32” or greater plywood or wood plank attached with #8 wood screws spaced 6” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(23): Base sheet mechanically fastened
All General and System Limitations apply.
Separation Sheet:
(Optional)
One ply of Glasbase Base Sheet, loose laid.
Base Sheet: One or more plies of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS
Base Sheet, mechanically attached as described below.
Fastening #1: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4” o.c. at the 3”
lap and 4” o.c. in four, equally spaced center rows.
Ply Sheet: One ply of Black Diamond Base Sheet, self-adhered to the base sheet.
Membrane: One ply of Flintlastic GTA or Flintlastic GTA-FR torch adhered to ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-105 psf (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 47 of 48
Membrane Type:
SBS Modified
Deck Type 1: Wood, Non-Insulated
Deck Description: 15/32" or greater CDX plywood or wood plank attached with #10 wood screws spaced 4” o.c. at
wood joists spaced maximum 24” o.c.
System Type E(24): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic
Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as
described below.
Fastening #1: Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3” Metal
Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac
Hextra with AccuTrac Flat Bottom plates, FlintFast #12 fasteners or FlintFast #14 fasteners with
FlintFast 3” Insulation Plates spaced 6” o.c. at the 4” lap and 6” o.c. in four, equally spaced
staggered center rows.
Ply Sheet:
(Optional)
One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base
Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base
Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic
Ultra Poly SMS Base Sheet, torch applied.
Membrane: One ply of Flintlastic GMS, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P,
Flintlastic Cap 30 or Flintlastic FR Cap 30 adhered to base or ply sheet with approved mopping
asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic
FR Cap 30 T torch adhered to base or ply sheet.
Surfacing:
(Optional)
Any of the approved surfacing/coating options listed in Table 4.
Maximum Design
Pressure:
-127.5 psf. (See General Limitation #7)
NOA No.: 20-0723.29
Expiration Date: 06/19/23
Approval Date: 09/17/20
Page 48 of 48
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping
with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap
and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not
acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of
either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof
Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from
Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS
117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this
NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE