HomeMy WebLinkAboutAPPROVED, Roof PackageS 1��jI'LI ILL R
i- I LI v ==
#R LUCIE
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 152S of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Attachments Required
See List Below
Low Slope Application
A, B, C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
Asphaltic Shingles
A, B, C
A, B, D
2,4,5,6,7
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D, E
Metal Roofs
A, B, D
Wood Shingles and
Shakes
A, B, D
1,2,4,6,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
From Product Approval:
2.
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4_
Other Component of Product Approval
Municipal Permit Application
S.
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
S
Section A (General Information)
Master Permit No.
Process No.
%a
Contractors Name: elf ' C j Ci Lz
Job Address
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes
Prescriptive BUR-RAS 150
ROOF ROOF TYPE_
❑ New roof ❑ Repair ❑ Maintenance XReroofing ❑ Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) t7V Steep Sloped Roof Area (SF) J'70Z) Total (SF) 75P
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
T LUCIE
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used,,; identify as "NA")
System Manufacturer: 'id���r7
Product Approval No.:
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': one 1: Zone 2: Zone 3:
Max. De gn Pressure, rom the spe ific product proval
system:
Deck:
Type:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
/Ba eaheet Fastener/Bonding rate ial:
Ai
Insulation Base Layer:
Base Insultation Size and Thickness:`
Base Insulation Fastener/Bonding Material:
Top Insulation Layer: .._ VAI
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 11—" oc @ Lap, # Rows—L i ° oc
Zone 1: " oc @ Lap, # Rows @ oc
Zone 2: " oc @ Lap, # Rows r�I� @4-oc
p oc
Zone 3: " oc @ Lap, # Rows— Ca
Number of Fasteners Per Insulation Boa. d:
Zone VA: Zone 14EZone 2aZone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.
FT.
Parapet
Height
Top Insulation Size and Thickness: q4 K " FT.
Top Insulation Fastener/Bonding Material: ,-Z
Mean
Base Sheet(s) & No. of Ply(s): Roof
Base Sheet Fastener/Bonding Material: r 2 Height
i
Ply Sheet(s)' & No. of Ply(s):r
Ply Sheet fastener/Bonding Material:
Top
�' .��
TPI : L T
vff�
Top Ply Fastener/Bonding Material:
T. L UCI
Section D (Steep Slope Roof System) ! r
Roof System Manufacturer: " A- ` 1 � t
Notice of Acceptance Number: 7
Minimum Design Wind Pre ures, If Appli ble (From RAS e 27 or Calc tions):
Zone 1:-"one 2e:�Zone 2n: one 2r: Zone 3e: Zone 3r: Wk
Deck Type:
Type Underlayment �Z
Roo 5Io pe:
12 Insulation:
Fire Barrier:
Ridge Vent' aton'? Fastener Type & Spacing:
L
Adhesive Type:IA-
Type Cap Sheet; .
Mean Roof Height: T Roof Covering:
Type & Size Drip �j �(�iE .
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values
are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable_
Method 1'IVloment Based Tile Calculations Per RAS 12T
(Zone 1: x X _� _ Mg. = Mn Product Approval ML
(Zone 2e: _ x ? = - M9; = MIft Product Approval Mf
(Zone 2n: x 2L _ _) -Mg: = Mom, Product Approval Mf
(Zone 2r: x),= - Mg: M0 Product Approval Mf
(Zone 3e: x X _ _) -- Mg. = Mrs. Product Approval Mom_..._
(Zone 3r: x A _ _. - Mg: = M,sr Product Approval Mf
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval Mf��/
Mr required Moment Resistance*
Mean Roof Height Roof Slope
15'
20'
25,
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3.12
4:12
32.2
30.4
34.4
32.2
36.0
33.8
37.4
35.1
39_8
37.3
5:12
6:12
28.4
26.4
30.1
28.0
3 .6
29.4
32.8
30.5
34.9
32.4
7:12
*
24.4
25.9
27.1
28.2
30.0
Must be used in conjunction with a list of moment ba ed a systems
• For Upfift based the systems use Method 3. Compare
t values for F' with the values for Fr If the F' values are greater than or
equal to the Fr values, for each area of the roof, the
e the attachment method is acceptable.
Method 3 "U
Based Tile Calculations Per RAS 12T
(Zone 1: x L =x W:=-W:
cos r =Fri Product Approval F'
(Zone 2e: x L =x W:= ) -
cos r =Fr2e Product Approval F
(Zone 2n: x L -x W:=
cos r =Fran Product Approval F'
(Zone 2r: x L =x W:= ) -W:
cos r =Fr2r Product Approval F'
(Zone 3e: x L =x W: =;7-) -W:
cos r =Fr3e Product Approval F'
(Zone 3r: x L =x W:=/ j -W:
cos r =Fr3r Product Approval F
Where to Obtain Information
Description Symbol Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
I prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
B
Job Site
Product Approval
Aerodynamic Multiplier
a
Restoring Moment due to Gravity
Mg
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
M8
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight W Product Approval
Tile Dimensions L = length W =width Product Approval
All calculations must be submitted to the building official at the time of permit application.