Loading...
HomeMy WebLinkAboutAPPROVED, Roof PackageS 1��jI'LI ILL R i- I LI v == #R LUCIE ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 152S of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 Asphaltic Shingles A, B, C A, B, D 2,4,5,6,7 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E Metal Roofs A, B, D Wood Shingles and Shakes A, B, D 1,2,4,6,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page From Product Approval: 2. Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4_ Other Component of Product Approval Municipal Permit Application S. 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 S Section A (General Information) Master Permit No. Process No. %a Contractors Name: elf ' C j Ci Lz Job Address ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes Prescriptive BUR-RAS 150 ROOF ROOF TYPE_ ❑ New roof ❑ Repair ❑ Maintenance XReroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) t7V Steep Sloped Roof Area (SF) J'70Z) Total (SF) 75P Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. T LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used,,; identify as "NA") System Manufacturer: 'id���r7 Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': one 1: Zone 2: Zone 3: Max. De gn Pressure, rom the spe ific product proval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): /Ba eaheet Fastener/Bonding rate ial: Ai Insulation Base Layer: Base Insultation Size and Thickness:` Base Insulation Fastener/Bonding Material: Top Insulation Layer: .._ VAI Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 11—" oc @ Lap, # Rows—L i ° oc Zone 1: " oc @ Lap, # Rows @ oc Zone 2: " oc @ Lap, # Rows r�I� @4-oc p oc Zone 3: " oc @ Lap, # Rows— Ca Number of Fasteners Per Insulation Boa. d: Zone VA: Zone 14EZone 2aZone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. FT. Parapet Height Top Insulation Size and Thickness: q4 K " FT. Top Insulation Fastener/Bonding Material: ,-Z Mean Base Sheet(s) & No. of Ply(s): Roof Base Sheet Fastener/Bonding Material: r 2 Height i Ply Sheet(s)' & No. of Ply(s):r Ply Sheet fastener/Bonding Material: Top �' .�� TPI : L T vff� Top Ply Fastener/Bonding Material: T. L UCI Section D (Steep Slope Roof System) ! r Roof System Manufacturer: " A- ` 1 � t Notice of Acceptance Number: 7 Minimum Design Wind Pre ures, If Appli ble (From RAS e 27 or Calc tions): Zone 1:-"one 2e:�Zone 2n: one 2r: Zone 3e: Zone 3r: Wk Deck Type: Type Underlayment �Z Roo 5Io pe: 12 Insulation: Fire Barrier: Ridge Vent' aton'? Fastener Type & Spacing: L Adhesive Type:IA- Type Cap Sheet; . Mean Roof Height: T Roof Covering: Type & Size Drip �j �(�iE . Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable_ Method 1'IVloment Based Tile Calculations Per RAS 12T (Zone 1: x X _� _ Mg. = Mn Product Approval ML (Zone 2e: _ x ? = - M9; = MIft Product Approval Mf (Zone 2n: x 2L _ _) -Mg: = Mom, Product Approval Mf (Zone 2r: x),= - Mg: M0 Product Approval Mf (Zone 3e: x X _ _) -- Mg. = Mrs. Product Approval Mom_..._ (Zone 3r: x A _ _. - Mg: = M,sr Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf��/ Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25, 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3.12 4:12 32.2 30.4 34.4 32.2 36.0 33.8 37.4 35.1 39_8 37.3 5:12 6:12 28.4 26.4 30.1 28.0 3 .6 29.4 32.8 30.5 34.9 32.4 7:12 * 24.4 25.9 27.1 28.2 30.0 Must be used in conjunction with a list of moment ba ed a systems • For Upfift based the systems use Method 3. Compare t values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, the e the attachment method is acceptable. Method 3 "U Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:=-W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= ) - cos r =Fr2e Product Approval F (Zone 2n: x L -x W:= cos r =Fran Product Approval F' (Zone 2r: x L =x W:= ) -W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W: =;7-) -W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:=/ j -W: cos r =Fr3r Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis I prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope B Job Site Product Approval Aerodynamic Multiplier a Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance M8 Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W =width Product Approval All calculations must be submitted to the building official at the time of permit application.