Loading...
HomeMy WebLinkAboutEngineering .tee Architectonic Inc St. Lucie County Planning& Development Services Building and Code Regulation Division April 1,2021 RE: 4180 N Highway A1A, Fort Pierce,FL 34949 To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2020 Florida Building Code, 165 mph wind zone, exposure "C", risk category II. From Table 1609.3.1: V„it= 165mph V,,d= 124mph From Table 1609.7(1): 16'h x 7'w door, 165mph=+23.7/-26.8 From Table 1609.7(2): 30' mean roof height, Exposure C= 1.40 Required Design Pressures: 24.8 x 1.40=34.7 -27.6 x 1.40=-38.7 Product:DAB Door Company,Series Model 924/811 Steel Garage Door, NOA#20-0901.24 Product Pressures: +48.0&-52.0 F.�-0� Respeetful�y Submitted;°`. SE -,® 111 ..n :o p�, r Mict%el'�Seal,AIA�96 .® Ar llitedtOnic, Inc. cep 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce,Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1