Loading...
HomeMy WebLinkAboutEVERHARD, WILLIAM_REVISION - SIGNED PEC031821DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 SAFETY LABELS PV-5.1 ATTACHMENT PLAN 5.1 PV-5.2 ATTACHMENT PLAN 5.2 PV-5.3 ATTACHMENT PLAN 5.3 PV-5.4 ATTACHMENT PLAN 5.4 PV-5.5 ATTACHMENT PLAN 5.5 PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXMODULE DATASHEET ARRAY WIRING BOX DATASHEET ARRAY WIRING BOX DATASHEET ARRAY WIRING BOX DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET UL 1703 CLASS A FIRE CERTIFICATION UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER EVERHARD PROPERTY ADDRESS 4305 REDWOOD DR, FORT PIERCE, FL 34951 US ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ CITY OF FORT PIERCE UTILITY COMPANY FLORIDA POWER & LIGHT CO ELECTRICAL CODE 2017 NEC (NFPA 70) FIRE CODE 2018 NFPA 1 OTHER BUILDING CODES 2020 FL BUILDING CODE CONTRACTOR INFORMATION COMPANY ENERGY SOLUTIONS DIRECT LICENSE NUMBER CBC1260807 ADDRESS 7965 9TH AVE S, ST. PETERSBURG, ST. PETERSBURG, FL 33707 PHONE NUMBER (800) 425-1175 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PV SYSTEM WITH NO ENERGY STORAGE DC RATING OF SYSTEM 11.52KW AC RATING OF SYSTEM 8.64KW AC OUTPUT CURRENT 36.0A INVERTER(S)36 X ENPHASE IQ7-60-2-US MODULE AXITEC AC-320MH/120S ARRAY WIRING (3) BRANCH OF 12 IQ7-60-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.12(A) UTILITY SERVICE 120/240V 1Φ SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 2% HIGH 33°C (91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED 160 MPH (ASCE7-10) RISK CATEGORY II WIND EXPOSURE CATEGORY C GROUND SNOW LOAD 0 PSF P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951PROJECT SUMMARY DOC ID:152525-188037-0 DATE:3/17/21 CREATOR: REVIEWER:P.C. REVISIONS PV-1 THIS ITEM HAS BEEN SIGNED AND SEALED BY PEDRO CRUZ, PE ON 18-MAR-2021 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED IS NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED IN ANY ELECTRONIC COPIES. GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. (N) AC COMBINER, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFNC CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE ROADWAY (N) VISIBLE, LOCKABLE, READILY-ACCESSIBLE AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER, OUTDOOR (E) MAIN SERVICE PANEL (MSP), OUTDOOR (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 6 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 0° AZIMUTH (N) TRANSITION BOX, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING (E) UTILITY METER, OUTDOOR (N) TRANSITION BOX, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 14 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 90° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 8 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 180° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 5 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 90° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 3 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 180° AZIMUTH ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951SITE PLAN DOC ID:152525-188037-0 DATE:3/17/21 CREATOR: REVIEWER:P.C. REVISIONS PV-2 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 16.7FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 6.6 FT = MAX(MIN(0.4 * 16.7 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:3/17/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.1 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 14.4FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 5.7 FT = MAX(MIN(0.4 * 14.4 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:3/17/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.2 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 16.7FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 6.6 FT = MAX(MIN(0.4 * 16.7 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:3/17/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.3 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 14.4FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 5.7 FT = MAX(MIN(0.4 * 14.4 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:3/17/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.4 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 16.7FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 6.6 FT = MAX(MIN(0.4 * 16.7 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:3/17/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.5 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". GENERAL NOTES 1 ACCESS AND SPACING REQUIREMENTS SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESSION FROM THE ROOF. THE AHJ SHALL BE PERMITTED TO REDUCED OR MODIFY ROOF ACCESS BASED UPON FIRE DEPARTMENT VENTILATION PROCEDURES OR ALTNERATIVE METHODS THAT ENSURE ADEQUATE FIRE DEPARTMENT ACCESS, PATWAYS, AND SMOKE VENTILATION. (NFPA 1 11.12.2.2.1) 2 NOT LESS THAN TWO 36 IN. (914 MM) WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM GUTTER TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLAN WITH A PV ARRAY, A 36 IN. (914 MM) WIDE PATHWAY FROM GUTTER TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PV ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. (NFPA 1 11.12.2.2.2.1) 3 FOR PV ARRAYS OCCUPYING UP TO 33 PERCENT OF THE PLAN VIEW ROOF AREA, A MINIMUM 18 IN. (457 MM) PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. FOR PV ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW ROOF AREA, A MINIMUM OF 36 IN. (914 MM) PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. (NFPA 1 11.12.2.2.2.2) 1.5 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.12.2.2.2.1 ROADWAY ROOF ACCESS POINT 3.0 FT. WIDE SMOKE-VENTILATION SETBACK, PER NFPA 1 11.12.2.2.2.2 1.0 FT. WIDE FIRE ACCESS PATHWAY PV MODULES INSTALLED ON ROOF WITH EVEREST CROSSRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 6/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1, 2, OR 3 MODULES. THE AXITEC AC-320MH/120S IS TYPE 1. 1.5 FT. WIDE SMOKE-VENTILATION SETBACK, PER NFPA 1 11.12.2.2.2.2 0.8 FT. WIDE FIRE ACCESS PATHWAY 1.5 FT. WIDE FIRE ACCESS PATHWAY TOTAL PLAN VIEW ARRAY AREA IS 583.2 SQ.FT, WHICH REPRESENTS 14.0% OF TOTAL PLAN VIEW ROOF AREA (4170.4 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951FIRE SAFETY PLAN DOC ID:152525-188037-0 DATE:3/17/21 CREATOR: REVIEWER:P.C. REVISIONS PV-7