Loading...
HomeMy WebLinkAboutAPPROVED Design Load Compliance form �l Planning& Development Services Department ' ` - Building&Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1577 Certification for Design Load Compliance Th Edition Project Name: Family Church / First Baptist Church of West Palm Beach Project Address: 115 NE Solida Drive Permit#: 2103-0301 Occupancy Type: Church Construction Type: Existing-Reroof INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • If submitting hard copy,submit(2)copies with all pertinent information.St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically,form should be uploaded into Bluebeam.Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format(PDF)version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply) 1. DESIGN CODE: Florida 2020 Code 7th Edition using ASCE 7-16 2. Structure Designed as(check one): X Enclose Partially Enclosed _Open 3. Risk Category: 1 II III IV Exposure Category: ✓ B C D 160 (P 0.07a) 14 LTIAtr►TE 4. Design Wind Velocity mph ASD ✓ LRFD End Zone Width: ft ►4 5. Mean Roof Height 35 ft Roof Pitch: 7 :12 Parapet: 0 ft �'CAU.oW0tOLl�) 6. Components&Cladding Design Pressures Used: •�� 1 :-61.2. -48?PAP) "S'4 irtF ' %.L4 r e-le: Zone 4r 5L•5 Zone 5: — (64.90 Garage: n/a .JaAZv.V-2A c'89•4(j�''�;•�KF) 6a. Roofs .7.1113 G s •►09.f?$F C IF-71*0 44.2 --109.5 �44fMNM�� .WAC-3r= '844 ap(-53.4,f6p) Maximum+/-pressures-}_ psf psf Or define individual zones on the plans 7. Design Loads: Floor: 60/150 PSF Roof-Dead: 20 PSF Roof-Live: 20 Balcony+/-n/a PSF Dock:n/a PSF Deck:n/a PSF Stairs: 100 PSF Fence: 0 PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain: Yes,roof diaphragm carries wind loading down through shear walls and into foundation. 9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: n/aA PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with th AIt4IoNtructural portions of the current Florida Building Code as adopted. EN JorC' �i Blake E. Joyce, P.E. #78432 1C Y P.E. (FL ) Signze, at Print Name Cert#&Co.CertofAuthorization = * 32 * = �G q Joyce Engineering, LLC (12397 157th St. N, Jupiter, FL 33478) Revised OR1 p. Company Name&Address 0 G� �� NA1. ���1/11110��i