ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A, B,C 1,2,3,4,5,6,7
Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7
Asphaltic Shingles A, B,D 1,2,4,5,6,7
Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7
Metal Roofs A,B,D 1,2,3,4,5,6.7
Wood Shingles and A, B, D 1,2,4,5,6,7
Shakes
Other As Applicable 1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable, RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form Roof1nfoFeb21 Rev Feb 18,2021
ST. LUCIE
Section A (General Information)
Master Permit No. Process No.
Contractors Name: ffi Cli+h eW 0(07—d License#_�A`N 13301905
Job Address Q�l t��—, ' L-j 1 Ct1 l�rl�l �' ��1Ci� �(L, '1 �e
ROOF CATEGORY
❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
(Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE-
0 New roof ❑ Repair ❑ Maintenance 6'Reroofing ❑Recovering
ROOF SYSTEM INFORMATI4..,
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 1\V� Total (SF)
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and level ]early identify dimensions of eleva ed pressure zones and location of parapets.
See A4iached
1
I j
i
1
i
I � !
I �
Low Slope Estimating, LLC Report Name: Drawing
LOWWSL ESTIMATING P: 214-585-3992
Print Date: 2/11/2021 1:11:44 PM
Bid: 115 ne salida, port st lucie
Section: Section 1 Page: sancuary
�u
�t
9
i
Thurcrlav_ Fphruary 11. 2021 Penn
ST. LUCIE
Section C ow Slope Roof) Surfacing:
Fill in specific ro assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1':_.._." oc @ Lap,#Rows @ °oc
(If a component is not u d,identify as"NA") Zone 1:—"oc @ Lap,#ROWS ® °00
System Manufacturer: Zone 2:—" oc @ Lap,#Rows ® "oo
Zone 3:—" oc @ Lap,# Rows @ °ac
Product Approval No.:
Number of Fasteners Per Insulation Board:
Design Wind Pressures, From RAS 128 Calculations: Zone 1': Zone 1: Zone 2: Zone 3:
Zone 1':_Zone 1: Zone 2: Zon 3: Illustrate Components Noted and Details as Applicable:
Max. Design Pressure, from the specific prod t approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing,Coping, Etc.,
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: Flashing,Component Material,Material'Thickness,Fastener
Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness:
Comply with RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet&No.df Ply(s): FF
FT.
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT.
Top Insulation Fastener/Bonding Material:
Mean
Base Sheet(s)&No. of Ply(s): i Roof
Base Sheet Fastener/Bonding Material: Height
Ply Sheet(s)'&No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
ST. LUCIEVV& tK"'
Section D (Steep Slope Roof System)
Roof System Manufacturer: �-41, A e ell fLON.An.% ckvy)
Notice of Acceptance Number- DR)
Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations):
Zone 1:-Zone 2e:-Zone 2n:-Zone 2r:-Zone 3e:-Zone 3r:
Deck Type:
Type Underlayment: -Psw 3D urvie(
Roof Slope: 14ncn� .
12] Insulation:
Fire Barrier:
Ridge Ventilation? ^ I Fastener Type&Spacing: oc 4;n tCL4
Adhesive Type: r
Type Cap Sheet:
Mean Roof Height: Roof Covering:
Type&Size Drip
Edge:
ST. LUCIE
Section E(Tile Calculations)
For oment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf. If the Mf values
are gr ter than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable.
11
Method 1 'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _x _ )--Mg: =M', Product Approval Mi
\2n
x = )-Mg: =M", Product Approval Mr
x X = -Mg: =M Product Approval Mf
x = )-Mg: =M,2, Product Approval Mf
x _ )--Mg: =M� Product Approval Mfx = �J-Mg: =Mr.� Product Approval Mf
Method 2 "Simplified Tile Calculations Per Table Below"
Required Mome(Mr) From Table Below Product Approval Mr
Mr required Moment Resistance*
Mean Roof Height Roof Slope 15, 20' 25' 30' 40'
2:12 K34.4 36.5 38.2 39.7 42.2
3:12 2.2 34.4 36.0 37.4 39.8
4:12 36,4 32.2 33.8 35.1 37.3
5:12 28. 30.1 31.6 32.8 34.9
6:12 26.4 28.0 29.4 30.5 32.4
7:12 24.4 25.9 27.1 28.2 30.0
*Must be used in conjunction with a list of mo ent based tile systems
• For Uplift based tile systems use Method 3. Co pare the values for F'with the values for Fr If the F'values are greater than or
equal to the Fr values,for each area of the roof,t n the the attachment method is acceptable.
Method 3"Up\Basedl-,Ieulations Per RAS 12T
(Zone 1: x L =x W:= )-W: i Product Approval F'
(Zone 2e: x L =x W:= )-W: r2e Product Approval F'
(Zone 2n: x L =x W:= )-W: r2n Product Approval F'
(Zone 2r: x L =x W:= )-W: 2r Product Approval F'
(Zone 3e: x L =x W:= )-W: 3e Product Approval F'
(Zone 3r: x L =x W:= )-W: 3r Product Approval F'
Where to Obtain Informal n
Description Symbol Where to find
From applicNableS 1Z7 or by an engineering analysis
Design Pressure Zones 1,2e,2n,2r,3e,3rprepared bySCE 7
Mean Roof Height H Job Site
Roof Slope i3 Job Site
Aerodynamic Multiplier a Product App
Restoring Moment due to Gravity Mg Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resistance Mg Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculations must be submitted to the building official at the time of permit application.