Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method i Project Name: DIFRANCESCO RESIDENCE Builder Name: TREFELNER CONSTRUCTION Street: HICKORY DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL , Permit Number: owner: COLTON DIFRANCESCO Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) i 1. New construction or existing New (From Plans) 10. Wall Types(1810.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1810.70 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1768.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1768.00 ft2 6. Conditioned floor area above grade (ft2) 1768 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(228.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 140 a. U-Factor: Sgl, U=0.32 177.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.32 30.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.19 a. Central Unit 29.4 SEER:16.00 c. U-Factor: Sgl, U=0.37 21.00 ft2 SHGC: SHGC=0.22 Area Weighted Average Overhang Depth: 2.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.216 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1768.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1768.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.129 Total Proposed Modified Loads: 60.76 PASS Total Baseline Loads: 61.94 I hereby certify that the plans and specification's covered by Review of the plans and Sr. ; this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. rrrq `�� .ate �, •O. PREPARED BY: �IgC Before construction is completed DATE: -12-2� this building will be inspected for 0, i compliance with Section 553.908 I hereby certify that this building, as d, ` 'n compliance Florida Statutes.; with the Florida Energy e. ©a.y, . . OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: i t - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/11/2021 9:29 AM EnergyGauge® UISA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: DIFRANCESCO RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1768 Lot # Qwner Name: COLTON DIFRANCESCO Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: TREFELNER CONSTRUCT[ Rotate Angle: 0 Street: HICKORY DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No 9. County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Epsting: New (From Plans) Comment: CLIMATE Design Temp V Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1768; 20060 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 176 1654.4 No 0 1 1 Yes Yes Yes 2 CLST 3 20 188 No 0 1 Yes Yes Yes 3 BATH 2 60 564 No 0 1 Yes Yes Yes 4 BEDROOM 2 176 1654.4 No 0 1 1 Yes Yes Yes 5 CLST 2 20 188 No 0 1 Yes Yes Yes 6 HALL 24 225.6 No 0 1 No Yes Yes 7 KITCHEN 374 5236 Yes 0 1 Yes Yes Yes 8 FAMILY ROOM 374 5236 No 0 1 Yes Yes Yes 9 MASTER BEDROO 256 2406.4 No 0 1 1 Yes Yes Yes 10 M WIC 66 1 620.4 No 0 1 No Yes Yes 11 M BATH 131 1231.4 No 0 1 Yes Yes Yes 12 LAUNDRY RM 63 592.2 No 0 1 Yes Yes Yes 13 M TOILET 28 263.2 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 26 ft 0 176 ft2 1 0 0 2 Slab -On -Grade Edge Insulation CLST 3 2 ft 0 20 ft2 ___ 1 0 0 3 Slab -On -Grade Edge Insulation BATH 2 6 ft 0 60 ft2 1 0 0 4 Slab -On -Grade Edge Insulation BED iROOM 2 26 ft 0 I 176 ft2 ___ 1 0 0 1/11/2021 9:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 20 ft2 __ 1 0 0 6 Slab -On -Grade Edge Insulation HALL 1 ft 0 24 ft2 -_ 1 0 0 7 Slab -On -Grade Edge Insulation KITCHEN 22 ft 0 374 ft2 -_ 1 0 0 8 Slab -On -Grade Edge Insulation FAMILY ROOM 22 ft 0 374 ft2 __ 1 0 0 9 Slab -On -Grade Edge Insulation MASTER BEDRO 32 ft 0 256 ft2 1 0 0 10SIab-On-Grade Edge Insulation M WIC 1 ft 0 66 ft2 __ 1 0 0 11SIab-On-Grade Edge Insulation M BATH 14 ft 0 131 ft2 __ 1 0 0 12SIab-On-Grade Edge Insulation LAUNDRY RM 9 ft 0 63 ft2 ___ 1 0 0 13SIab-On-Grade Edge Insulation I M ITOILET 11 ft 0 28 ft2 ___ 1 0 0 ROOF / V Roof # Type Materials Area Gable Area Roof Color Rad Barr Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 1977 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1768 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 3 20 Blown 176 ft2 0.1 Wood 2 Under Attic (Unvented) CLST 3 20 Blown 20 ft2 0.1 Wood 3 Under Attic (Unvented) BATH 2 20 Blown 60 ft2 0.1 Wood 4 Under Attic (Unvented) BEDROOM 2 20 Blown 176 ft2 0.1 Wood 5 Under Attic (Unvented) CLST 2 20 Blown 20 ft2 0.1 Wood 6 Under Attic (Unvented) HALL 20 Blown 24 ft2 0.1 Wood 7 Under Attic (Unvented) KITCHEN 20 Blown 374 ft2 0.1 Wood 8 Under Attic (Unvented) FAMILY ROOM 20 Blown 374 ft2 0.1 Wood 9 Under Attic (Unvented) MASTER BEDRO 20 Blown 256 ft2 0.1 Wood 10 Under Attic (Unvented) M WIC 20 Blown 66 ft2 0.1 Wood 11 Under Attic (Unvented) M BATH 20 Blown 131 ft2 0.1 Wood 12 Under Attic (Unvented) LAUNDRY RM 20 Blown 63 ft2 0.1 Wood 13 Under Attic (Unvented) M TOILET 20 Blown 28 ft2 0.1 Wood 1/11/2021 9:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT (SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S Exterior Concrete Block - Int InsuBEDROOM 3 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 _ 3 W Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 4 S Exterior Concrete Block- Int Insul BATH 2 4.1 6 0 9 4 56.0 ft2 0 0 0.6 0 _ 5 E Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 _ 6 S Exterior Concrete Block - Int InsuBEDROOM 2 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 _ 7 E Exterior Concrete Block- Int Insul CLST 2 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 8 W Exterior Concrete Block - Int Insul KITCHEN 4.1 22 0 14 0 308.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block- Int IrisLFAMILY ROO 4.1 22 0 14 0 308.0 ft2 0 0 0.6 0 10 N Exterior Concrete Block- Int InsuMASTER BE 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 11 W Exterior Concrete Block - Int InsuMASTER BE 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 _ 12 N Exterior Concrete Block- Int Insul M BATH 4.1 10 0 9 4 93.3 ft2 0 0 0.6 0 _ 13 E Exterior Concrete Block- Int InsuLAUNDRY R 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 14 N Exterior Concrete Block - Int Insul M TOILET 4.1 3 0 9 4 28.0 ft2 0 0 0.6 0 15 N Exterior Concrete Block - Int InsuLAUNDRY R 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Single Yes 0.32 0.22 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 W 2 Vinyl Low-E Single Yes 0.32 0.22 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 3 S 4 Vinyl Low-E Single Yes 0.37 0.22 Y 6.0 ft2 2 ft 0 in 1 ft 4 in None None 4 E 5 Vinyl Low-E Single Yes 0.32 0.19 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5 S 6 Vinyl Low-E Single Yes 0.32 0.22 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 8 Vinyl Low-E Single Yes 0.32 0.22 Y 9.0 ft2 2 ft 0 in 1 ft 4 in None None 7 W 8 Vinyl Low-E Single Yes 0.32 0.22 Y 48.0 ft2 2 ft 0 in 1 ft 4 in None None 8 E 9 i Vinyl Low-E Single Yes 0.32 0.22 Y 16.0 ft2 2 ft 0 in 1 ft 4 in None None 9 E 9 Vinyl Low-E Single Yes 0.32 0.22 Y 24.0 ft2 2 ft 0 in 1 ft 4 in None None 10 N 10 Vinyl Low-E Single Yes 0.32 0.22 Y 20.0 ft2 2 ft 0 in 1 ft 4 in None None 11 W 11 Vinyl Low-E Single Yes 0.32 0.22 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 12 N 12 Vinyl Low-E Single Yes 0.37 0.22 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 13 E 13 Vinyl Low-E Single Yes 0.32 0.19 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000504 2340.3 128.4 241.05 .1453 7 1/11/2021 9:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split Single SEER: 16 29.4 kBtu/hr 882 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None ILAUNDRY RM 0.92 50 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC ! Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- v — Return— Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar HeatinJan Feb Mar �,Apr Ar M Jun Jul May Jun Jul AuSep rl Au Se Oct M Oct W Nov Nov Dec Dec Ventin Jan Feb Mar A r Ma Jun Jul Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 I 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY ROOM 1/11/2021 9:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft. ft 0.3 MASTER BEDROO • Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft' ft 0.3 M BATH Default(8lbs/sq.ft. ft' ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ftz ft 0.3 M TOILET 1/11/2021 9:29 AM Energy-aug— USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software I Page 6of6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. HICKORY DRIVE, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1810.70 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1768.00 ft2 6. Conditioned floor area (ft2) 1768 b. NIA R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=0.32 177.00 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 140 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.32 30.00 ft2 SHGC: SHGC=0.19 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.37 21.00 ft2 a. Central Unit 29.4 SEER:16.00 SHGC: SHGC=0.22 d. U-Factor: N/A fP 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COPA.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.216 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF:0.92 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1768.00 ft2 Credits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Oth rwise, a new EPL Display Card will be completed based on installed Code mpliant fP es. Builder Signature: f Z Date: a4 Z Address of New Home: rCity/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/11/2021 9:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1