FL # FL10758-RB
Application Type Revision
Cade Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/PhoneJEmail
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence or Proauct standards
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keelcr@owenscorning.com
Greg Keeler
g reg. kee le r0 o wen scorn I ng . co m
Greg Keeler
2790 Columbus Road
Granville, OH 43023
(740)321-6345
g reg.keeler@owenscorning,com
Roofing
Roofing Accessories that are an Integral Part of the Roofing System
Evaluation Report from a Florlda Reg lstered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Flardropy Received
Zachary R. Priest
PE-74021
PRI Constructfon Materials Technologles, LLC
12/31/2024
5teven M. Urich, PE
Validation Checklist Hardcopy Received
RJ0758 R8 COi OC 14 0 .4 2020 rBC Eval Vents final
https:llwww.floridabuliding.org/prfpr_app_dtl_aspx?param=wGEVXQwtDgvldAvlteCYDZ2bC3zFtrydgg[PhgLACiVmpHfxgcDSASJQ%3d%3d Page 1 of 3
Certified By
Sections from the Code
1708.2
Product Approval Method Method 2 Option B
Date Submitted
08J10/2420
Date Validated
12/16/2020
❑ate Pending FBC Approval
09/18/2020
Date Approved
12/17/2020
Summary of Prof
FL It f Model, Number or Name j Description I
10758.1 4-Foot Strip Heat and
Copolymer plastic low proffle attic ridge vents for Installation
__lVentSure
Moisture a en
9
In shingle roof systems
9
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10758 R8 LL-OCRI4003,4 202 FB Fval V n s final .pdf
Approved for use outside HVHZ: Yes
Verified By: Zachary R. Priest 74021
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to evaluation report
FL10758_ R8 AC OCR14003.4 2020.F%, Eval Vents final pddf
Created by Independent Third Party. Yes
_.....u._._. _._.._..
10756.2 VentSure Low Profile Slart Back
� Galvanized metal roof vent
mm Roof Vent with Exterior Lauver
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
1 FLI0758 R8 4 n _,a
Approved for use outside HVHZ: Yes
Verified By: Zachary R. Priest 74021
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to evaluation report.
FL107SB gLAE_QQR14003,4 202tl F(3G Fval V_P_nra_ final__. f
Created by Independent Third Party: Yes
10758.3 1 VentSure Rigid Roll Ridge Vent
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other* Refer to evaluation report.
Ridge Ventilation System
Installation Instructions
F 1 75 _3$ II QCR14005,4 2020 FBC Eval Vents final,--,ndf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
F1_1075g R8AC- OCRI400.4 2020 FBC Eval Vents fi al _,pdf
Created by Independent Third Party: Yes
Sack El
Ca ntact_Us 2fj blalf .tone Road. 7anaMssee Fl U3gq Ph One; arr-4A7.7A1e
The State of Florida Is ail AMEEO employer. Coomnollt 2007-2013 ate of Florida.:: Priv em n I III to ;; RRrund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a pub]Ic-remrds request„ do not send electronic
mail bo this entity. Instead, contactthe office by phone or by traditional mall, if you have any questFnns, please contact 850.487.1395. 'Aursuant to Section
455.275(1), Florida Statutes, effective O(Yoder 1, 2012, licensees licensed under Chapter 455. F.S. must provide the Department with an email address 1f they have
one. The ematls provided may be used for official communicat]on with the licensee. However email addresses ere public record. if you do not wish to Supply a
Personal addre55, please provide the Department with an email address which Can be made avallable to the public. To determine if you are a licensee under Chapter
455, F.5-, please dick h -
Product Approval Accepts:
WI F--7-0 P~- M
https:ljwww.rloridabuilding.orgipripr_app_dt1.aspxYparam=WGEVXQwtOgvldAVIYBQYCY2bC3ZFIrydggtPhgLACiVmFHfXqaD3A5JQ%3d%3d Page 2 of 3
�ecurit� a11:T.RIC
https:/jwww.floridabuilding_orgjprJpr_app_dtl.aspx?param=wGEVXQwtDgvldAvlteOYO"/2bC3zFtrvdg9fPhgi_ACiVmFHfXgoD3A5JQ%3d%3d Page 3 of 3
Certificate of Autharirption No. 29824
C R E E IK"' �i 17520 Edinburgh Dr
Tampa, FL33647
TECHNICAL SERVICES, L-LC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7'" EDITION (2020)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC fssuecf December 15. 2020
1 Owens Corning Parkway
Toledo, ON 43657
{800)438-7465
yyww. owenscomina.com
Quality Assurance: PRI Construction Materials Technologies (QUA9110)
SCOPE
Category:
Roofing
Subcategory:
Roofing Accessories that are an Integral Part of the Roofing System
Code Sections:
1708.2
Properties:
Roof Ventilation
REFERENCES
Entity
Report No.
Standard
Year
Architectural Testing, Inc (TST1550)
01-38650 04
TAS 100(A)
1995
Architectural Testing, Inc; (TSTi558)
01-386S0.05
TAS 1CC(A)
1995
Architectural Testing, Inc (TST1558)
C1774.01-109-18
TAS 100(A)
1995
ASTM D 635
2014
ASTM D 1929
2016
ASTM D 2843
2016
PRI Construction Materials Technologies (TST5878)
AVIG-005-02-01
ASTM D 635
2014
ASTM D 1929
2016
ASTM D 2843
2016
PRI Construction Materials Technologies (TST5878)
AVIG-006-02-01
ASTM G 155
2013
PRI Construction Materials Technologies (TST5876)
OCF-111-02-01
ASTM D 635
2014
ASTM D 1929
2016
ASTM D 2843
2016
PRI Construction Materials Technologies (TST5878)
0CF-112-02-01
ASTM G 155
2013
PRI Construction Materials Technologies (TST5878)
0CF-116-02-01
TAS 100(A)
1995
PRI Construction Materials Technologies (TST5878)
OCF-223-02-01
TAS 100(A)
1995
PRI Construction Materials Technologies (TST5878)
OHi-007-02-01
TAS 100(A)
1995
OCR14003-4 FL10758-R8 Paue 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3 The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
ororifirvlE.r ad.i.ocnnrl he min
CREEK
>: TECHNICAL SERVICES, LL,C
PRODUCT DESCRIPTION AND APPLICATION
❑WENS CORNING
VentSureg Roof Ventilation
VentSure"4-Foot Strip 1-114" x 14-718" x 48" low -profile attic ridge vent consisting of a two -layer nylon -
Heat and Moisture Ridge polyester composite_ Available with or without a polyester fabric moisture barrier for
Vents: installation in shingle roof systems.
48"
14-718"
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12 to maximum 16112
installation Height: Maximum 50-11
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 6-inches from the rake
edges. Apply a '/,inch wide bead of ASTM D 4586 roofing cement along the entire
length of the outside edges of the vent to seal the vent to the field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga. 2%-inch galvanized ring shank nails
(shall comply with FBC Section 1506.5) provided with the vent, Fasteners are to be
installed on both sides of the vent 1, 12. 24. 36, and 47-inches from the start of each
vent piece.
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten to the deck in the same manner as the first
section. Fasten the ridge shingles over the vent to the deck on the marked "shingle
nail line" with two (2) minimum 11 ga. 2Y27inch galvanized ring shank roofing nails
(shall comply with FBC Section 1506.5) provided with the vent or as directed by the
shingle manufacturer's installation instructions.
Allowable Roof Coverings: Asphalt shingles
OCR14003.4 FL10758-RS Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Service,, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
c.wn inn[[.. n.t.2roccod hnn�:n
i OWENS CORNING
VentSureG Roof Ventilation
TECHNICAL SERVIcEs. LLC
VentSure�' Low Profile 18" x 24" x 2-3115" (32" x 23" flange base) static off -ridge vent composed of ASTM
Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with
with Exterior Louver: FBC Section 1507.4.3.
I
F'; n
ws� a-iA'
AA- 1 _, i
t j
LL
Deck Type: Roof deck shall be constructed of closeiy fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12
Installation Height: Maximum 33-ft
Attachment Method- Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from
the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM ❑ 4586 roofing cement
around inner and outer flange. Place vent directly over the hole, ensuring the vent
sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange
with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5), ensuring M.-inch penetration through wood deck (Minimum 18 nails per
vent).
Install baffle in 'Y inch bed of ASTM[ D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1500.5)
spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through
wood deck. Seal all nails and vent flange with ASTM d 4566 roofing cement.
Allowable Roof Coverings: Asphalt shingles
CCR14003.4 FL10758-RS Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Sorvices, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
cnenifir���,� erlrlrecc erl Fern in
- --_' CREEK OWENS CORNING
VentSureg) Roof Ventilation
TECHNICAL SERVtCEs. LLC
VentSurert' Rigid Roll 518" x 11-114" x 20' attic ridge vent composed of high density polypropylene with a
Ridge Vent: spun -bond polypropylene fabric,
neck Type- Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall he designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation_ The slot shall terminate approximately 12-inches from the rake
edges. Apply a continuous bead of polyurethane adhesive sealant along the entire
length of the outside edges of the vent to seal the vent to the field shingles. Center
the vent over the opening and fasten the vent 24-inches o.c. to the deck using
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5),
ensuring %-inch penetration through wood deck
Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line'
with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1566.5) or as directed by the shingle manufacturer's installation instructions.
ensuring %-inch penetration through wood deck. Outside edges of the shingles shall
be sealed with flashing cement -
Allowable Roof Coverings: Asphalt shingles
LIMITATIONS
1) This report is net for use in the HVHZ.
2) Fire Classification is outside the scope of this evaluation,
3) The roof deck and deck attachment shall be designed by others in accordance with the FBC.
4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the
manufacturer's published installation instructions. In the event of conflict, the more restrictive installation
shalt be enforced.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion prior to installation.
6) Installation of the roof assembly is outside the scope of this evaluation.
7) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
OCR14003A FL10758-RB Page 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify Mr=EK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
r-.e�� �<<i erfrirncccN hero �..
CREEK
TECHNICAL, SERVICES, LLC
COMPLIANCE STATEMENT
OWENS CORNING
VentSure® Roof Ventilation
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7�h Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
`.it{III llfjf/
F'' ( R. 1'r�`rr
No 74021
O=, STATE OF ,:�
p R tO,.���.
N A��;;.►'.
CERTIFICATION OF INDEPENDENCE
2020.1115
13:59:34
-05'D0`
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or dlstrlbuting products antler
this evaluation,
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any Other entity involved in the approval process of the
product.
EN❑ OF REPORT
OCR14003.4 FL10758-R8 PaQe 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
enenifn.�lhr aririrnecorl heroin