HomeMy WebLinkAboutBuilding PlansGENERAL NOTES
STRUCTURAL DESIGN STATEMENT
1. DO NOT SCALE THESE DRAWINGS. WRITTEN DIMENSIONSTAKE
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE
PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH
SHALL REVIEW THESE DRAWINGS IN THEIR ENTIRETY BEFORE:
THE APPLICABLE STRUCTURAL PORTIONS OF THE BUILDING CODES.
COMMENCING CONSTRUCTION AND SHALL ACCEPT FULL
I ALSO CERTIFY THAT THE STRUCTURAL COMPONENTS, SYSTEMS, &
RESPONSIBILITY FOR ANY ERRORS OR OMISSIONS NOT REPORTED
RELATED ELEMENTS PROVIDE ADEQUATE RESISTANCE TO WIND
IMMEDIATELY IN WRITING TO THE WHOLE HOUSE ENGINEERING,
LOADS AND FORCES SPECIFIED BY THE CODES LISTED BELOW.
LLC. BACK CHARGES WILL NOT BE ACCEPTED.
2. THE GENERAL CONTRACTOR SHALL VERIFY THE BUILDING POSITION
WITHIN THE SETBACK LINES PRIOR TO COMMENCING
DESIGN PARAMETERS & ASSUMPTIONS
CONSTRUCTION.
CODE EDITION:
3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO E'E
■ FLORIDA BUILDING CODE 2020, 7TH EDITION
FAMILIARIZED WIT ALL EXISTING CONDITIONS AS THEY AR NOT
■ ASCE':7 (EXPOSURE CONDITION): B
NECESSARILY SHOWN ON THESE DRAWINGS.
CONSTRUCTION TYPE: VB
4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING
OCCUPANCY CLASSIFICATION: R_3
LOCATIONS OF ALL FLOOR, ROOF, AND WALL OPENINGS AND
PENETRATIONS.
BUILDING DESIGNED AS:
5. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO COORDINATE
❑ PART;ALLY ENCLOSED
THE WORK OF ALL TRADES, DETERMINE ERECTION PROCEDURE,
■ ENCLOSED
AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING, ITS
❑ OPEN
COMPONENTS, AND TRADE BASE DURING CONSTRUCTION.
❑ TESTEO (WIND TUNNEL)
6. ALL DETAILS AND SECTIONS SHOWN ON THESE DRAWINGS ARE
INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO
BUILDING HEIGHT:
ANY SIMILAR CONDITION ELSEWHERE IN THE WORK EXCEPT WHERE
■ <_ 60 FT,. ASCE 7.
A DIFFERENT DETAIL AND OR SECTION IS SHOWN.
❑> 6WF.T. MUST USE ASCE 7.
7. BUILDER IS RESPONSIBLE FOR ADEQUATE BRACING OF STRUCTURAL
OR NON-STRUCTURAL MEMBERS DURING CONSTRUCTION,
MEAN ROOF HEIGHT: <15 FT.
8. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PROVIDE ALL
FOR L01V RISE BUILDING WITH SLOPED ROOFS.
NECESSARY SHOP DRAWINGS, WINDOWS, DOORS, ETC. T
WHOLE HOUSE ENGINEERING, LLC FOR REVIEW AND APPROVAL.
RISK FACTOR: 11
9. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER
DETERMINED BUILDING USE/ OCCUPANCY, REFER TO ASCE 7
STRIPPED.
TABLE 1.5-1.
10. THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARETHE
PROPERTY OF WHOLE HOUSE ENGINEERING, LLC., AND SHALL NOT
INTERNAL PRESSURE COEFFICIENT: +/-0.18
BE USED OR REPRODUCED WITHOUT THE EXPRESS WRITTEN
CONSENT OF WHOLE HOUSE ENGINEERING, LLC.
ENCLOSED BUILDING.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
REQUIRED BUILDING AND TRADE PERMITS AND FOR THEIR
BASIC WIND VELOCITY PRESSURES:
RESPECTIVE COSTS.
APPROPRIATE POSITIVE/ NEGATIVE PRESSURE COEFFICIENTS HAVE
12. THESE DRAWINGS ARE DIAGRAMMATICAL AND ARE INTENDED TO
BEEN APPLIED TO MAIN WIND FORCE RESISTING SYSTEM, AND
SHOW DESIGN INTENT ONLY. THEY DO NOT SHOW EVERY OINOR
BUILDING ENVELOPE COMPONENTS AND CLADDING, AS
DETAIL OF CONSTRUCTION. ALL TRADES ARE RESPONSIBLE FOR
APPLICABLE;
FURNISHING COMPLETE BUILDING SYSTEMS AND ALL ITEMS THAT
WIND SFEED (3 SEC.GUST): 150 MPH
WOULD NORMALLY BE CONSIDERED INCIDENTAL TO THEIR
BASIC VELOCITY PRESSURE: 24.9 PSF
INSTALLATION.
NOTE:ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR
WINDOWS, DOORS, GARAGE DOORS AND SIMILAR ENVELOPE
FLOOR PLAN NOTES
ELEMENTS ARE INDICATED ON CONSTRUCTION PLANS.
l . NATURAL VENTILATION. I CERTIFY THAT THIS HOME IS DESI NED TO
COMPLY WITH THE NATURAL VENTILATION REQUIREMENTS OF
SECTION 402 OF THE FLORIDA BUILDING CODE, MECHANICAL.
2. SAFETY GLAZING. ALL GLAZING IN SLIDING AND SWINGIN
DOORS, INCLUDING SHOWER AND TUB ENCLOSURES, TO BE
SAFETY GLAZED -.t,3 PER FBC 2406.4 & R308.4. ALL GLAZING IN ANY
HAZARDOUS LOCATION OF A BUILDING WITH SILL LESS THAN 60"
A.F.F. SHALL BE SAFETY GLAZED AS PER FBC 2406.4 (5) & R 08.4(2)
ALL GLAZING WITHIN 24" OF AND PARALLEL TO A DOOR SHALL BE
TEMPERED.
3. FIRE BLOCKING. PROVIDE FIRE BLOCKING AT ALL CONCEALED
SPACES.
4. SHUTTERS. STORM SHUTTERS WITH AN ACCEPTED PRODUC
APPROVAL SHALL BE PROVIDED AT ALL OPENINGS EXCEP1 THOSE
PROTECTED BY APPROVED IMPACT RESISTANT DOORS AN
WINDOWS.
5. ROUGH OPENINGS. VERIFY ALL ROUGH OPENING AND MASONRY
OPENING SIZES WITH MANUFACTURER'S PRODUCT
SPECIFICATIONS.
6. EGRESS WINDOWS. EGRESS WINDOWS SHALL BE OPERAS E FROM
THE INSIDE WITHOUT THE USE OF TOOLS. EGRESS WINDOW SHALL
HAVE A MINIMUM NET OPENING OF 24" HIGH, 21 WIDE, A D MIN.
NET AREA OF 5.7 S.F. FOR 2ND FLOOR WINDOWS AND 5.0 S.F. FOR
1 ST FLOOR WINDOWS. THE SILL HEIGHT SHALL NOT BE MORTHAN
44" ABOVE THE FLOOR, LATCH AT 54" A.F.F. MAX.. OPERABLE
WINDOWS WITH A SILL PORTION OF THE OPENING LOCATED LESS
THAN 24" A.F.F. AND MORE THAN 72" ABOVE FINISHED GRADE:'
SHALL INCLUDE A WINDOW OPENING CONTROL DEVICE HAT
COMPLIES WITH SECTIONS R312 2 1 AND R312 2 2 OF THEF.R.C.
DRAWING INDEX 7. INTERIOR NON -BEARING WALLS. 25 GA., 3.5" STEEL STUDS 24"
O.C. (20GA. @ 16" O.C. IN AREAS RECEIVING TILE AND W T
SHEET SHEET TITLE REV AREAS) W/ 1/2" GYPSUM BOARD ON BOTH SIDES (TYPICAL). 2X4
P.T. SILL PLATE FASTENED TO SLAB -ON -GRADE BELOW WAL .
GN-1 GENERAL NOTES 8. BATHTUB AND SHOWER SPACES. BATHTUB & SHOWER FLOORS &
A 1.0 EXISTING AND PROPOSED PLANS WALLS ABOVE BATH TUBS WITH INSTALLED SHOWER HEADS & IN
SHOWER COMPARTMENTS SHALL BE FINISHED WITH AN
IMPERVIOUS, NON -CORROSIVE, NON -ABSORBENT & WATERPROOF
MATERIAL. MOISTURE RESISTANT BACKING BOARD REQUIRED
UNDER IMPERVIOUS WALL AREAS IN BATH TUB & SHOWER PACES.
SUCH WALL SURFACES SHALL EXTEND NOT LESS THAN C-O" ABOVE
THE ROOM FLOOR LEVEL.
9. GARAGE SEPARATION FROM DWELLING UNIT. GARAGES ALL BE
SEPARATED FROM THE DWELLING UNIT AND ITS ATTIC AREA BY
MEANS OF A MINIMUM 1 /2" GYPSUM BOARD APPLIED TO THE
GARAGE SIDE.
10.GARAGE DUCTS. DUCTS IN THE GARAGE & DUCTS PENETRATING
THE WALLS OR CEILINGS SEPARATING THE DWELLING UNIT ROM
THE GARAGE SHALL BE MIN..019„ SHEET METAL & SHALL HAVE NO
I
OPENINGS INTO THE GARAGE.
11.EXTERIOR OPENINGS. NO OPENINGS ARE PERMITTED IN THE
EXTERIOR WALL OF BUILDINGS SEPARATED FROM ADJACE14T
BUILDING BY A DISTANCE OF LESS THAN 6-0".
12.13ACKING FOR CABINETS. PROVIDE 2X4 MINIMUM HORIZONTAL
BACKING IN KITCHEN W/ TOP @ 35" A.F.F. & TOP @ 8'-0" A.F.F. & IN
BATHROOM VANITY AREAS W/ TOP @ 30" A.F.F. OR AS REQUIRED
FOR CABINET ATTACHMENT.
13. WOOD FRAME WALLS. WOOD FRAME WALLS AND HEADERS ARE
DESIGNED USING RATIONAL ANALYSIS.
14. SAFEGUARDS. WHERE THERE IS A DROP OF MORE THAN 4 FEET OR
MORE ON THE FAR SIDE OF THE OPERABLE OR FIXED GLAZED
PANELS 24" OR GREATER IN WIDTH AND THE SILL I LESS THAN 36"
ABOVE THE NEAR SIDE WALKING SURFACE, SAFEGUARDS SHALL BE
PROVIDED AS SET FORTH IN 4403.7.3.
CONCRETE PLAN NOTES
1. ALL CONCRETE TO ATTAIN A MINIMUM ULTIMATE COMPRESSIVE
STRENGTH OF 3,000 PSI IN 28 DAYS. AGGREGATES TO BE CLEAN
AND WELL GRADED, 1-1 /4" MAXIMUM SIZE. CONCRETE SLUMP IS
TO BE 5" MINIMUM TO 6" MAXIMUM. 2,500 PSI, FOR, SLABS ON
GRADE & FOUNDATIONS. I,
2. MINIMUM CONCRETE COVER FOR REINFORCING BARS:
• FOOTINGS CAST AGAINST SOIL: 3" MIN.
• SLABS (CAST AGAINST SOIL W/ VAPOR BARRIE 1 1 /2" MIN.
• SLABS (ABOVE GRADE LEVEL: 3/4" MIN.
• BEAMS AND COLUMNS: 1 1 /2" MIN.
3. REINFORCING BARS, UNLESS OTHERWISE SPEC,IF E , SHALL BE NEW
BILLET STEEL MEETING A.S.T.M. A615, GRADE 60. EINFORCING
BARS SHALL BE DETAILED, FABRICATED, SUPPC1R�f ID IN FORMS AND
SPACED WITH ACCESSORIES FOLLOWING THE' REQUIREMENTS OF
THE "MANUAL OF STANDARD PRACTICES FOR DEVILING
REINFORCED CONCRETE STRUCTURES. (A.C.I.318. ".
4. LAP ALL REINFORCING BAR SPLICES 48 BAR DIAMETERS (UNLESS
OTHERWISE NOTED). ALL REINFORCING BARS SHALL BE SECURELY
WIRED TOGETHER IN THE FORMS. TWO-WAY MAT OF STEEL SHALL
BE TIED AT ALTERNATE INTERSECTIONS BOTH WAYS. PROVIDE
CORNER BARS AT ALL CORNERS FOR ALL CONTINUOUS
REINFORCING IN UNIT MASONRY #5 X 5-0" (30" EACH WAY)
UNLESS OTHERWISE NOTED.
FOUNDATION PLAN NOTES
1. SLAB ON GRADE: 4" THICK 3,000 PSI CONCRETE SLAB WITH 6"X6" /
W 1.4 X W 1.4: WELDED WIRE MESH LOCATED IN THE MIDDLE TO
UPPER 1/3 OF SLAB, SUPPORTED 3'-0"ON CENTER MAX., ON 6-MIL.
VAPOR BARRIER, ON CLEAN 95% COMPACTED TERMITE TREATED
FILL. DESIGN SOIL BEARING CAPACITY IS 2,000 PSF ACTUAL
BEARING CAPACITY MUST BE CERTIFIED TO MEET . ,000 PSF MIN. BY
AN ARCHITECT OR A PROFESSIONAL ENGINEER.
2. CORNER BARS: ALL BARS OF FOUNDATION STEEL SHALL BE
CONTINUOUS AROUND CORNERS USING CORNER BARS W/ A
MINIMUM LAP SPLICE OF 30" (48 BAR DIAMETERS).
3. INTERSECTING BLOCK WALLS: AT ALL INTERSECTING BLOCK
WALLS, INTERWEAVE CONCRETE BLOCK OR BREAK OUT A 5" X 5'
HOLE BETWEEN WALLS@ 24" O.C. VERTICALLY TO ALLOW
CONCRETE TO FILL BOTH CELLS.
REINFORCED MASONRY NOTES
1. DESIGN OF THE REINFORCED MASONRY IS BASED ON THE
BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI
530) AND THE SPECIFICATIONS FOR MASONRY STRUCTURES (ACI
530.1) .
2. CONCRETE BLOCK SHALL BE NEW AND UNDAMAGED AND
CONFORM TO THE REQUIREMENTS OF ASTM C90, F'M = 1900 PSI
MIN. BLOCK IS TO BE HANDLED AND STORED TO PREVENT
DAMAGE TO AND CONTAMINATION OF THE UNITS.
3. MORTAR TO CONFORM TO THE REQUIREMENTS F ASTM C270,
TYPE M OR S. MORTAR TO BE TESTED IN ACCORgANCE WITH ASTM
C1314 AT THE BEGINNING OF THE PROJECT AND AT EVERY 5000 SF
OF WALL AREA.
4. GROUT FOR FILLED CELLS SHALL BE 3000 PSI (MIN) AND CONFORM
TO THE REQUIREMENTS OF ASTM C476 WITH A SLUMP OF 8" TO 10".
CONCRETE FILLED CELL MIX WITH A P OF 2500 PSI AND A SLUMP
OF UP TO 8" MAY BE SUBSTITUTED FOR THE SPECIFIED GROUT.
GROUT (OR FILLED CELL MIX) TO BE TESTED EVERY POUR AND AT
EVERY 50YARDS MINIMUM. WHEN GROUTING IS STOPPED FOR
ONE HOUR OR MORE, THE GROUT SHALL BE STOPPED 1.5" BELOW
THE TOP OF THE CONCRETE BLOCK.
5. REINFORCING STEEL SHALL COMPLY WITH ASTM A615, GRADE 60.
ALL STEEL TO BE #5'S UNLESS NOTED OTHERWISE, PLACED IN THE
CENTER OF THE CELLS, UNLESSNOTED OTHERWISE. CELLS TO BE '
FREE OF MORTAR AND CELLS SHALL ALIGN VERTICALLY TO
MAINTAIN A CLEAR UNOBSTRUCTED VERTICAL CELL, MINIMUM
WIDTH OF GROUT SPACE SHALL BE 4". STEEL TO BE LAPPED 48 BAR
DIAMETERS MINIMUM AND HOOKED INTO BEAMS 10"MINIMUM.
6. CLEANOUTS SHALL BE PROVIDED FOR ALL FILLED CELLS AT THE
BOTTOM OF EACH LIFT FOR INSPECTION,
7. MATERIAL CERTIFICATES SHALL BE SUBMITTED AND APPROVED FOR
THE REINFORCING STEEL, MASONRY UNITS, MORTAR AND GROUT
MATERIALS.
8. WHERE DOWELS WERE NOT PROPERLY PLACED IN THE
FOUNDATION, NEW DOWELS MAYBE DRILLED( /4" X 8" DEEP
MIN.) AND SET IN PLACE WITH EPDXY WITH 'US A CHOR
ULTRA -BOND EPDXY'.
9. SHORING DESIGN MUST BE SUBMITTED AND APPIJOVED PRIOR TO
PLACING BLOCK ON STRUCTURAL MEMBERS NOT DESIGNED FOR
THE WEIGHT. THE DESIGN OF THE BRACING OF WALLS UNDER
CONSTRUCTION MUST ALSO BE SUBMITTED AND. PPROVED PRIOR
TO CONSTRUCTION.
FRAMING PLAN NOTES
i. THE ROOF FRAMING PLAN SHOWS LOCATION & DIRECTION OF
ALL ROOF MEMBERS (TRUSSES AND GIRDERS). FOR INDIVIDUAL
TRUSSES, SEE LAYOUT & ENGINEERING SHEETS BY TRUSS
MANUFACTURER.
2. ALL CONCRETE BEAMS TO BE A MINIMUM OF 8" X 12" WITH (2) #5
BARS TOP & (2) #5 BARS BOTTOM UNLESS NOTED OTHERWISE ON
PLANS.
3. AT ALL POURED CONCRETE BEAM AND BOND BEAM
INTERSECTIONS, EXTEND BOND BEAM STEEL 30" INTO POURED
BEAMS.
4. ANY OF THE SPECIFICALLY NOTED BEAMS MAY BE BUILT UP TO 1"
SMALLER OR 2" LARGER WITHOUT ANY CHANGE OF REQUIRED
STEEL,
5. STIRRUPS NOT REQUIRED UNLESS NOTED OTHERWISE.
6. ALL HEADERS & WOOD BEAMS TO BE (2) 2''X12" HEM -FIR #2 UNLESS
NOTED OTHERWISE ON PLAN.
7. #2 S.Y.P. MAY BE SUBSTITUTED ANYWHERE HEM -FIR IS !SPECIFIED.
8. PROVIDE FILLED CELLS @ MINIMUM 6" ABOVE & 6" BELOW ALL
EXPANSION BOLT LOCATIONS IN C.B.S. WALLS (TYPICAL).
9. SPACE FLOOR TRUSSES ACCORDINGLY TO AVOID CONFLICT W/
PLUMBING FIXTURE DRAINS ABOVE. COORDINATIE W/
ARCHITECTURAL PLANS.
10. ANY WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE
TREATED.
ABBREVIATIONS:
AB
ANCHOR BOLT
ABV
ABOVE
AFF
ABOVE FINISHED FLOOR
AFI
ARC FAULT INTERRUPT
ALUM
ALUMINUM
AHU
AIR HANDLER UNIT
BF
BI-FOLD
BP
BI-PASS
BLK
BLOCK
BRKFST
BREAKFAST
BLK'G
BLOCKING
BM
BEAM
BRG
BEARING
BTM
BOTTOM
CAB
CABINET
CER
CERAMIC
CJ
CONTROL JOINT
CL
CENTER LINE
CLG
CEILING
CLO
CLOSET
CLR
CLEAR
CMU
CONCRETE MASONRY UNIT
COL
COLUMN
CONC
CONCRETE
CONN
CONNECTION
CSMT
CASEMENT
CTR
CENTER
DBL
DOUBLE
DF
DRINKING FOUNTAIN
DIA
DIAMETER, ALSO O
DSP
DISPOSAL
DP
DESIGN PRESSURE
DR
DOOR
DW
DISHWASHER
EA
EACH
EE
EACH END
EJ
EXPANSION JOINT
ELEC
ELECTRIC
EMER
EMERGENCY
EQ
EQUAL OR EQUIVALENT;
ES
EACH SIDE
ESP
ELECTROSTATIC PAINT
EW
EACH WAY
EXT
EXTERIOR
EXST
EXISTING
EXP
EXPANSION
FBC
FLORIDA BUILDING CODE
FDN
FOUNDATION
FF
FINISHED FLOOR
FLUOR
FLOURESCENT
FO
FLOOR OUTLET
FIR
FIRE RATED
FRDR
FRENCH DOOR
FRM
FRAME
FRM'G
FRAMING
FT
FOOT, FEET
FURR
FURRING
GT
GIRDER TRUSS
GA
GAUGE
GALV
GALVANIZED
GFI
GROUND FAULT INTERRUPT
GL
GLASS
GND
GROUND'
GYP
GYPSUM
GYP BID
GYSPUM WALL BOARD
HB
HOSE BIB
HC
HOLOW CORE
HT
HEIGHT
HORZ
HORIZONTAL
HM
HOLLOW METAL
H PS
HOOPS
HR
HOUR
HVAC
HEAT VENT. & AIR COND.
HVHZ
HIGH VELOCITY HURRICANE ZONE
ID
INSIDE DIMENSION
INSUL
INSULATION
INT
INTERIOR
LAM
LAMINATE
LAV
LAVATORY
LG
LONG
LIN
LINEN
LGT
LIGHT
LT
LAUNDRY TUB
MAX
MAXIMUM
MC
MEDICINE CABINET
MECH
MECHANICAL
MRH
MEAN ROOF HEIGHT
MTL
METAL
MFR
MANUFACTURER
MW
MICROWAVE
MIN
MINIMUM
MIR
MIRROR
MO
MASONRY OPENING
MONO
MONOLITHIC
OBSC
OBSCURE
OC
ON CENTER
ABBREVIATIONS (CONTINUED):
OHD
OVER HEAD DOOR
OPP
OPPOSITE
OS
OUTSIDE DIMENSION
PLF
POUNDS PER LINEAR FOOT
PSF
POUNDS PER SQUARE FOOT
PSI
POUNDS PER SQUARE INCH
PT`
PRESSURE TREATED
PRT'N
PARTITION
PH
PHONE
PKT
POCKET
PLYWD
PLYWOOD
PNL
PANEL
R
RADIUS
REF
REFERENCE
REINF
REINFORCING
REQ'D
REQUIRED
REQ'M
REQUIREMENT
RM
ROOM
RO
ROUGH OPENING
SC
SOLID CORE
SQHED
SCHEDULE
SGD
SLIDING GLASS DOOR
SF.
SQUARE FOOT
SH
SINGLE HUNG
SHF
SHELF
SHWR
SHOWER
SPEC
SPECIFICATION(S)
SMIS
SHEET METAL SCREW
SQ
SQUARE
SS
STAINLESS STEEL
ST
STIRRUPS
STD'
STANDARD
STL
STEEL
SW
SWITCH
SYM
SYMMETRICAL
TMP'D
TEMPERED
TB
THROUGH BOLT
TBM
TIE BEAM
THK
THICK
T&G
TONGUE & GROOVE
TOB
TOP OF BEAM
TOBB
TOP OF BOND BEAM
TOPL
TOP OF WOOD PLATE
TOTB
TOP OF TIE BEAM
TPH
TOILET PAPER HOLDER
TYP
TYPICAL
LINO
UNLESS OTHERWISE NOTED
UL
UNDERWRITERS LABORATORIES
VERT
VERTICAL
A
VERIFY IN FIELD
WA
WEDGE ANCHORS
W/
WITH
wC
WATER CLOSET
WEB;
WOOD
"Wh
ELECTRIC WATER HEATER
WM
WASHING MACHINE
WP
WATERPROOF
WPH
WALL PHONE
WSCT
WAINSCOT
WT
WEIGHT
-7--a /a-o(
At
ElOcr
PREPARED FOR:
SHERYL GRIFFEN
F! F
WHOLE HOUSE ENGINEERING
4451 ST. LUCIE BLVD, SUITE201
FORT PIERCE, FL 34946'
CONTACT: 772.409.1003
ENGINEERING(c,)WHENGINEERING.NET
DRAWING NOTICE:
THESE DRAWINGS AND DOCUMENTS ARE
CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE
ENGINEERING, LLC. AND MAY NOT BE
REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF
WHOLE HOUSE ENGINEERING, LLC.
WARNING: DO NOT SCALE DRAWINGS.
PLEASE CONTACT DESIGNER WITH ANY
QUESTIONS REGARDING DIMENSIONS.
ARCHITECTURAL SYMBOLS CONTAINED
WITHIN THESE DOCUMENTS ARE FOR
GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY IN ORDER TO MEET
THE MANUFACTURER'S SPECIFICATIONS.
REVISION
aTE I BY I REV
PROJECT NUMBER, NAME & ADDRESS:
RENOVATION FOR:
GRIFFEN RESIDENCE
6801 COQUINA
AVENUE
FORT PIERCE, FLORIDA
DRAWN BY:
D SANDERS
SHEET TITLED :
GENERAL NOTES
SHEET NO. :
EXISTING ALUMNIUM EXISTING STRUCTURE
TUBE STEEL (OUT OF SCOPE
F_ ------ — — — — — — — — — — ---
D5L 2 x 4 TOP PLATE I I
WITH MIN 24" OVERLAP EXISTING ROOF
AT SPLICE --- ------------------- ------ --
-- -- — — — — — ----
3/8" TOGGLE BOLT WITH SIMPSON H3 CLIP WITH 10
I" FLAT WA5HER AT 24" Sd NAILS AT TOP AND
O.G. MAX SPACING 50TTOM OF EACH STUD
6
/ 65x 4 SH T in
1/2" GYPSUM DRYWALL01/_6 x 6
2 x 4 WOOD STUDS HARDI PANEL
(MIN 02 SPF) AT 12" O.C. + SIDING
HARDIPANEL SIDING OVER
TYVECK HOUSE WRAP OVER R-11 SATT INSULATION
1/2" CDX PLYWOOD SHEATHING
DEIL.26 +212
FRENCH
S I S
6 60 36 48
+22.2 +22.2
-29.6 -296
it
:fa
STUDY
EXISTING CEILING +212 SH 9
52 x 48
4" 9
1-1'_411
12"
GI-011
NI
IN
PREVIOUS SGD
OENING
PREPARED FOR:
SHERYL GRIFFEN
8d NAIL H3 CLIP WITH 10 - _ u _�._ _ „ _
Sd NAILS AT TOP AND -� � � �4 4451 ST: LUCIE BLVD, SUITE 201
50TTOM OF EACH STUD _ FORT PIERCE, .4 3.100
er
4946
L.—_..__ CONTACT: 772.409.1003
&CALEE 1/4" ]'-Oil =JGG�L� j/[l 11 j' ENGINEERING(a7WHENGINEERING.NET
3/0" DIA WEDGE ANCHORS2 x 4 P.T. BOTTOM PLATE
AT 24" O.C. MAX SPACING
WOOD 5ASE
DRAWING NOTICE:
EXISITNG GRADE EXISTING CONCRETE SLAS THESE DRAWINGS AND DOCUMENTS ARE
CONFIDENTIAL AND ARE THE SOLEI
Iii AND FOOTING
7V PROPERTY OF WHOLE HOUSE
ENGINEERING, LLC. AND MAY NOT BE
0 ° ` d AFF / REPRODUCED, DISSEMINATED OR
/ I REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF
a I
WHOLE HOUSE ENGINEERING, LLC.
I
I I WARNING. DO NOT SCALE DRAWINGS.
PLEASE CONTACT DESIGNER WITH ANY
I
I QUESTIONS REGARDING DIMENSIONS.
it I II
ARCHITECTURAL SYMBOLS CONTAINED
NOTE : WITHIN THESE DOCUMENTS ARE FOR
TIE ALL NEW ELECTRICAL INTO SPARE
GRAPHIC PURPOSES ONLY. SIZE AND
CIRCUITS IN EX15ITNG 150 AMP PANEL LOCATION MAY VARY IN ORDER TO MEET
F T THE MANUFACTURER'S SPECIFICATIONS.
WP
"I 0—"CFI-----------EXIU, ---
---- —---
-- _ — --_------=
SCALE : 3/4" = 1'
EXTERIOR DOOR & WINDOW
DESIGN PRESSURES s
PRODUCT
1 APPROVAL
EXP.
OPENING
PRODUCT RATED NUMBER
WIDTH
HEIGHT
COMMENTS
REMARKS
DESIGN
DESIGN PRESSURES
PRESSURES
Pos. NEG.
4'4"
4'-0"
SINGLE HUNG WINDOW
JELD-WEN
SEE PLAN
+50.0
-55.0
FL31796.1
31011
4' 0"
SINGLE HUNG WINDOW
JELD-WEN
SEE PLAN
+65.5
76.2
F1_31796.1
3- `0"
5' 0"
SINGLE HUNG WINDOW
JELD-WEN
SEE PLAN
+65.5
76.2
FL31796.1
51011
F 1
64"
DOUBLE FRENCH DOORS
RSL
1 1
SEE PLAN
1
N/A
INIA
1
FL# 15419
�1
N
p5L. 26fo4
FF ENCH DRS
HAIRDI PANEL
SIDING
LICENSE # 88906
RAMA PRANAV KRISTAN
SCALE 1/4" = 1'-0"
IR VATE OF a
EXISTING 1400E a'fs/q•� `pR�O `Q��a
q
U I
I'
� I
I,
I
X I HARD PANEL
w I SIDING
SGALEE : 1/4" = V-011
REVISION DATE BY REV
PROJECT NUMBER, NAME & ADDRESS:
RENOVATION FOR:
EXISTING ROOF GRIFFEN RESIDENCE
6801 COQUINA
AVENUE
u FORT PIERCE, FLORIDA
- I
- I N
I
X
DRAWN BY:
D SANDERS
EAST
I SHEET TITLED
TONEXISTING / PROPOSED
SCALE -. 1/4" = I'-011 E COPY
SHEET NO. :
A