HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design load Compliance
Project Name:GRIFFEN RESIDENCE
Project Address: 6801 COQUINA AVE N U E
Permit #: 201 0-0632 Occupancy Type: I I Construction Type: VB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
i
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or, multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: 'Form not required for interiorirenovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN, PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 201Z 1 Cgde Sixth Edition with 20 Supplements using ASCE 7-10
IStructure Designed as (check one):' /Enclosed Partially Enclosed Open
3. Risk Category: I _�1/ II III IV Exposure Category:_�,/_B C D
4. Design Wind Velocfty mph ASD LRFD//�� End Zone Width: p ft
5. Mean Roof Height 150 ft Roof Pitch: NA J2 Parapet:NA VA ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 22.2f1one 2: 22.2iZone 3: 22.2/Zone 4: 22.2/Zone 5: 22.2/-Garage:
7. Design Loads: Floor: NA PSF Roof/Dead: NA PSF Roof/Live: NA Balcony: NA PSF
Dock: NA PSF Deck: NA PSF Stairs: NA PSF Fence: NA PSF Railings: NA PSF
8. Were Shear Walls Considered For Structure? Yes -, Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Yes u Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: NA PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified-
"' RAMA PRANAV KF
`eR Print Name Cert # & Co. Cert Auth.
FL PE 88906
No. 88 6
Senatlke..QatViQM Seal c — WHOLE HOUSE ENGINEERING
ATE OF = Company Name & Address
S
FILE COP