Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance2 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Century Complete - 1 Project Address: XXXX Co Permit #: ina ;Ave, Fort Pierce, FL 34951 Occupancy Type: Construction Type: RECEIveo NOV 13 AID ft La91 INSTRUCTIONS FOR USE: 4 • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential,'; (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 20.17 Code Sixth Edition with 20 NSA Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.33 ft 5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +19.3,-30.6 Zone 2: +19.3,;53.3 Zone 3: +19.3,-78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,44.8 Garage: +31.7/-38.6 7. Design Loads: Floor: 40 'PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: NSA PSF Dock: NSA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? Y Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 1500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that struct al elements depicted on these plans provide adequate resistance to the design forces sp ;'�S Glee OOa,® oo�®e aQ��� James G. Friling � � � c'a�® Print Name Cert # & Co. Cert Auth. No *% 7824 j�• PE #77824 COA #27228 g Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002 ,,°�tS' °eo� R I �'`.� •:a I Company Name & Address Revised 12rd7if i °L �IG711OIQRd` ,.