HomeMy WebLinkAboutProject Information- wrightsoft® Project Summary House One Stop Cooling and Heating 7225 Sardscove Court, W irter Park, FL 32792 Pfnre: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC1817652 Notes: I Design I Information Weather: Melbourne Regional, FL, US Job: 1246 RHG Date: 07/23/2020 By: LVL Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 68 OF Inside db 74 OF Design TD 25 OF 17 OF I Daily tinge Relative humidity . 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 110656 Btuh Structure 10327 Btuh Ducts 1073 Btuh Ducts 2204 Btuh Central vent (0 cfm) I 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 11730 Btuh Use manufacturer's data n Rate/swin multiplier Equipment load 0.96 11980 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2372 Btuh Ducts 546 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1230 1230 Equipment latent load 2918 Btuh Volume (ft3) 9843 9843 Airchanges/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 14898 Btuh Equiv. AVF (cfm) 74 38 Req. total capacity at 0.75 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NBO1800GOA0 Cond CH14NB01800GOAO AHRI ref 9162108 Coil FB4CNP018L AHRI ref 9162108 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heating Input Sensible cooling 13350 Btuh Heating output 17600 Btuh @ 47°F Latent cooling. 4450 Btuh Temperature rise 0 OF Total cooling 17800 Btuh Actual air flow 0 cfm Actual air flow 593 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0.50 in H2O Space thermostat Load• sensible heat ratio 0.81 Capacity balance point = 33 OF Backup: Input =13 kW, Output = 43093 Btuh,4100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -d- wrightsoft- 2020-Nov-091138:10 Rigtt-Sute®Uriversal 201919.0.20 RSU18908 Page 1 Cogdna Ave\TBD Cogdna Ave 1246 B RHG - W Gaut Calc= MJ8 Frort Door faces: N -�- wrightsoft Right-JO Worksheet Job: 1246 RHG House I Date: 07/23/2020 One Stop Cooling and Heating By: LVL 7225 Sardscove Coot, W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OnaStopCooling.com License: CAC1817652 1 Room name House Krr 2 Exposed wall 127.9 it 10.0 It 3 Room height 8.0 It d 8.0 It heaV000l 4 5 Room dimensions Room area 1230.4 ft2 12.0 x 10.0 ft 120.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BWhhtz.0 (BtuW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PiS Heat Cool 6 12C-0sw - 12C-Osw -6.691 0.091 _ _n I e1 227 __ - 227 J 2.34 2.34 - - 246 116 - --242 75 - 948 170 _ - 667 52 176 - - -- - -8-0 0 v - - 74 0 - 168 0 173 0 11 4A5-2ov 4A5-2ov 0.320 0.320 a a 7.97 7.97 22.64 22.64 6 15 0 0 48 120 136 340 0 ' 0 0 0 0 0 0 0 y/ ! .. _G 11 DO T - 12C-0sw :4A5-2w--..._._.:.� ___•_ 0.390 0.091 _._-_-_0.320 - e s � ,-s.. 9.71 227 -___7.97 7.82 2.34 .-_.8.80 -- 20 384 .�: 15 20 195 �--836 ------ 120 157 ---~ 865 _.-._ _132 0 -�- 0 _- -- - 0 0 '�- -- 0 __.---0 0 --' -0 0 - --0 _.--0 � 369 12 V)J L�_pG - 12C-Osw 4A5-2ov .11D0.-0.390- 0.091 0,320 w w w- 227 7.97 2.34 22.64 276 45 213 0 483 359 499 1019 214 0 0 0 0 0 0 0 0_ 0 0 0 R 12C-Osw 0.091 _ __9.71_-_11.99-- 227 ' 1.44 --1818-_-174 • 294 276 625 - 398 ---0 96 -- 96 - - .' 218 138 11D0, . _._.__- _ __ .:__ _0.390 -n_ _,- _ 9.71-.._-: 7.82 __----18 _ - ----18 - --- 174 • .._-._ 140 _-_.<<_0 , _ -_-__0 _- _ 0 C.-_. 16B30ad -- . 0032 0:80 2136 120 96 208 -,--__ __- - 29.33 _1,74 _0.00 _ --_1230 1230 _ .____1230 . _-_� 128 _•_._-_9BO -3758 _ 0 -_ _ -- 120 _ _120 __ ,10 -- 294 _. --0. 6 c) AED excursion 190 -92 Envelope loss/gain 8636 7019 822 480 12 a) Infiltration 2020 688 158 54 b) Roomventiladon 0 0 0 0 13 Internal gains: OccupantsQa 230 4 920 0 0 Applianceslother 1700 1200 Subtotal (lines 6to 13) 10656 10327 980 1733 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 72 545 14 Subtotal 10656 10327 1053 2278 15 Dudloads 100/0 21% 1073 2204 10% 21% 106 486 ETotal room load 11730 12531 1159 2764 Airrequired(dm) 0 593 0 131 to meet all requirements of -11.f- wr9gttitsoft� RigFrt-Bute®Universal 201919.0.20 RSU18908 2020-Nov-091128:10 Coquina Ave1TBD Cogrna Ave 1246 B RHG - W C.rui Calc = MJ8 FrortDoor faces: N Page 1 - wrightsoft° Right-J® Worksheet Dot,: ,gasRHG House Date: 07/23/202/2020 By: LVL One Stop Cooling and Heating 7225 Sandscove Coat, Winter Part, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.00m License: CAC1817652 1 Room name BED 3 MBED 2 Exposed wall 28.0 ft 31.0 ft 3 Room height 8.0 ft heaUcool 8.0 It heat/cool 4 5 Room dimensions Room area 1.0 x 135.5 ft 135.5 ft2 1.0 x 230.5 ft 230.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuW,F) (BtuhAt2) or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-Osw '4A5-2ov . _...__ 12C-0sw 0.691 __....0,320 0.091 J n n a 227 ..__ 7.97J 227I __ 2.34 _ __ 8.60 2.34 " 32 . -- - -- 0 88 -* 32 -. ._ _..._ 0 67 73 _. _. . 0 152 -. _. 75 , ._ . _ 0 157 _ _ 0 0 ...-____. 0 _ 0 _ 0 0 _ - 0 0 11 4A5-2ov 4A5-2ov 0.320 0.320 el a 7.97II 7.97I 22.64 22.64 6 15 0 0 48 120 136 340 0 0 0 0 0 0 0 0 V)J 11 DO ...___ ._ _�._ 12C Osw 4A5 2ov___ _, _ _ _ 12C-Osw _- 0 390 u91. _0320. 0.091 _ e sr -s_ w'� 9.71 22 _ 7.97 227 _ 7.82 2.34 _-_8:80 2.34 0 104 _ ___.... 0 0 0 104 . -.. ;.__ 0 0 -_ _ _ . 0 236 --- ___--0 0 _ 0 04 _____ . _0 0 0 _� 112 T..: 0 136 _ _ 0 `- - 11-2 _-_ 0 121 0 _ 04 ._ _ 0. 274 0 - 262 - 8 284 4A5-2ov 0 320 w 7.97 22.64 0 0 0 0 15 0 120 340 fj 11D0 12C-Osw __- 0390 0.091 _w1 , - _T9.71 227 _ _11.99 1.44 _- 0 0 0 0 ___.. 0 0 _-_-0 0 0 0 ._ _ _. 0 0 0 0 - -� - 0 - -- --0 0. _. -. 0 _--- -0 136 136 108.------._235 184 400 F _ _ -22A-cpm-_.___ ---1 180 I 2938 _-0.00 136 ..- - 28 823 . 0 _._._ _231 - 231 --�231.. 31. ;_ _ 911. 0. n 6 c) AED excursion 79 81 Envelope loss/gain , 1558 1265 1742 1367 12 a) Infiltration 442 151 489 167 b) Room ventilation 0 0 0 0 13 Internal gains: Oaupants@ 1 Appliances/other 230 1 230 0 2 460 0 Subtotal (lines 6to 13) 2000 1646 2231 1993 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 238 189 76 60 14 Subtotal 2238 1834 2307 2053 15 Ductloads 10% 21% 225 392 10% 21% 232 438 Total room load 2463 2226 2539 2492 Air required (dm) 0 105 1 0 118 J 8th Ed. �}r wr➢gF�tTsoR• � AZUN Right-Suite@UriXprsal 20l9 l9.0.20 RSU18908 Coquina Ave1TBD Coquina Ave 1246 B RHG - W C,.rut Calc = MJ8 Frert Door faces: N 2020-Nov-0911:38:10 Page 2 i 1- wrightsoft° Right-JO Worksheet House ! One Stop Cooling and Heating Job: 1246 RHG Date: 07/23/2020 By: LVL 7225 Sandscove Coot, Winter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirig.com License: CAM 817652 1 Room name '. MBA 2 Exposed wall O ft 5.0 It 3 Room height 8.0 ft heaV000l 8.0 ft heaV000l 4 5 Room dimensions Room area 3.0 x 3.0 ft 9.0 ftz 11.0 x 5.0 It 55.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (BtuhA1z-*q (BtuhAt) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/Pi5 Heat Cool Gross N/P/S Heat Cool 6 y/- !_ G 12C-Osri 4A52ov- ----- _ .-- -- 0.091 --- . 0.320 - -n-I ---n.,. ------ - 227 - _._ .7.97 2.34 __- _8.60 0 __.: _0 0 .----- .---0 0 ---- - -- 0 - , O - - - - 0 .._._._ - -.0 0 0. 0 _ 12C-Osw 0.091 a 227 2.34 0 0 0 0 0 - 0 -- - ---- 0 -_ 0 11 4A5-2ov 4A5-2ov 0.320 0.320 a a 7.97 7.97 22.64 22.64 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Vh -._ 11D0 - - - 12C-bsw .4A5-2o,Y_-- --- - - - 0_390 0.091 -----0.320 -e- s - s:..:__72 9.71 227 ---�'� 2.34 _--8.80 - - -0 0 -,0 - ---0 -0 ., _ _ 0 - --0 0 - ... _ --0 - -0. 0 .. - 0 _ -- - 0 40 -- - ._ 0 0 40 --- ---0 0 - ' 91 - 0 0 - 94 -- -- --0 _L-G V)J 12C-Osw 0.091 w i 227 2.34 0 0 0 0 0 0 0 0 4A5-2ov 0.320 w, 7.97 9.71 22.64 11.99. 0 Q---- 0 0 0 0 0 0 0 0- 0 0 0 0 0 RIj _11D0 -- - - ----0390 0.091 --W' - 227 _ -1.44 -- - 0 0 ---- 0 -- - 0 --- 0 - - 6 _ _ _ - -0 _ _ _ _0 0 _.! -D _C - -- 11 _ DO - 16630ad0.0321°749 - -- -- - -- 0.390 - - - - n- - 1 - 9.71 ..--- --- -7.82 ------0 -- - 0 ----___9716�..__.__..5544 0 --- -0. ------0 - -. .0 __ -•--- 0 - - 0 ------55 • - 0 ------- 5 - - 0 -----,--147 - -- 0 95. - -- -- -0 6 c) AED excursion 1 11 Envelope loss/gain 17 15 281 178 12 a) Infiltration 0 0 79 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 Applianoesrother 0 0 0 0 0 0 Subtotal (lines 6 to 13) 7 15 360 205 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution -7 -15 108 86 14 Subtotal 0 0 468 291 15 Dud loads 10 % 21 % 0 0 10% 21 % 47 62 Total room load 0 0 516 353 Air required (cm) 0 0 0 17 Calculations -r" d- wprYgtitsoft� Right-Srite®Uriversal201919.0.20 RSU18908 Coquna Ave1TBD Coquina Ave 1246 B RHG - W C.iut Calc = MJ8 Frort Door faces: N 2020-Nov-091108:10 Page 3 i wrightsoftRight-J® Worksheet House One Stops Cooling and Heating Jab: 1246 RHG Date: 07/23/2020 By: LVL 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.00m License: CAC1817652 1 Room name LIV LAUN 2 Exposed wall 34.5 ft O It 3 Room height 8.0 It heaU000l 8.0 it heaU000l 4 Room dimensions 1.0 x 310.5 ft 3.0 x 6.0 ft 5 Room area 310.5 ft2 18.0 ft2 Ty Construction U-value Or I HTM Area (ft2) Load Area (ft) Load number (Btuh/ft --n (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS . Heat Cool Gross N/PS Heat Cool 6 .._ _ .. 12C 0sw -- - - - - - 0.091 227 .-.--- 2.34 -- 136 136 - 30$ -319 b:• - - 0 -- -0 0 4A572ov - -- - ---0.320 . -n ' - _7.97 . _ __ 8.60. 0 - - -0- - ---'- _0 -O - --0 - - - -0 ---.---0 - - - ---- 0 �r�/�] 12C-Osw 0.091 a 227 2.34 0 0 0 0 0 0 0 0 4A5-2ov 0,320 a 7.97 22.64 0 0 0 0 0 0 0 0 I-G 11 4A5-2ov 0.320 a 7.97 22.64 0 0 0 0 0 0. 0 0 L-0 11D0_-----_ 12C Osw _-0390 0.091 _e . s 9.71 227 7.82 2.34 0 0 _ _ _ 0 0 _ 0 0 0 0 _0. 0 _._ _ _ 0 0 --- 0 0 0 0 �--G 4A5,2ov_,_ _0 . _ _0 - - _--_ V+/ 12C-Osw 4A5-2ov 0.091 0.320 w r w 227 7.97 2.34 22.64 140 30 92 0 209 239 216 679 0 0 0 0 0 0 0 0 97111.9918.._ 1.8174`_--214----_�.000------ 0 12C-Osw ' 0.091 - - 227 _- 1.44 0 0 -0 0 24 54 .95 24 .11D0. - _ --- 0.390 n -----9.71 ---7.82_ _.�.-0 •.0 - - -0. ---__0 - - --0 -- -0 -- -0 0 C_. F. - 16B-30ad_.._._ 22Acpm- -= ------ _.0.032. -- -1 j80: _..: i _ 0.80 --29.38. 1.74 -----0.00 311- - --- --311 311 -- - -35 247 _- _ 1014 _--- 539 ---._._ 0 �8 __._ - _..18. _.. 18.14 -- - 0 --•--___ 31. - - 0 _ _. -- -0 _..._-_ __-_ 6 c) AED excursion 246 -29 Envelope loss/gain 2191 2213 69 37 12 a) Infiltration 544 186 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 500 Subtolal(lines 6to13) 2735 2399 169 537 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 142 117 -69 -537 14 Subtotal j 2877 2516 0 0 15 Duct loads 10% 21% 290 537 101/. 21% 0 0 Total room load 3167 3053 0 0 Airrequired (dm) 0 144 0 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-091118:10 Rigft-Suite@Uriversal 20l9 l9.0.20 RSU18908 Page 4 Coquina Ave\TBD Coquina Ave 1246 B RHG - W C�rut Calc = MJ8 Front Door faces: N I I I I- wrightsoft° Right-JO Worksheet Job: 1246 RHG House Date: 07/23/2020 By: LVL One Stopi Cooling and Heating 7225 Sardsceve Court, W irter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOrLStopCoolirg.com License: CAC1817652 1 Room name BA2 BED 2 2 Exposedwall 5.5 it 10.5 It 3 Room height 8.0 it heatl000l 8.0 ft heaVocol 4 5 Room dimensions Room area 9.0 x 5.5 it 49.5 f12 1.0 x 125.5 It 125.5 R2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BWhAt 10 (Btuhffl or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 %t' _ WIC 12C' Osw - - 4A5.2ov-_ _ _ 12C-Osw - 0.091 _ _ 0.320 0.091 - n n e1 227 _7.97 - 227 2.34 _-__-8.60 2,34 - _ _ 0 . _.-0 0 -- _ _ 0 0 __ _ - _ 0 _ _0 0 -0 . _ _ 0 -0 0- 0 0 0 __ 0 0 _ 0 0 11 4A5-2ov 4A5-2ov, 0.320 0.320 a a 7.97 7.97 22.64 22.64 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �p -- UN 11D0_.- - - ------ 12C•Osw __ 0399 0 091 e; ^-s 9.71 227 7.82 -- -2.34 _.- -- 0 44 --_ .0 44 _ 0 100 _ 0 - 109 0 - 84 0 . - - -69 0 - 156 0 1622 ___( 4A52ov_- . .___-._0320---s 797 1--.-- ---8.80 __-0 0._---0, _ :_ 0._._. _-_ 15 12 -___ 120 --__ 132. 0 0 V)! 12C-Osw 4A5-2ov 0.091 0:320 w w 227 7.97 2.34 22.64 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _---__-11D0 R -O_-_ _-- 12C91 sw -__-. 0.390wa•_- - 971 .227 __11.99_0 1.44 0 0__0-__00. 0 _0 _ 0 _0 �--- -11D.4 - - - 00.0390 _ n, -- -9.71 -- 7.82 . -----0 - - 0 -- - - -0 - ---0 •---- -0 - .0_._ - - -O C F- -- 1613-30ad :22A m.._ - - -- 0.032 -----1.180 - = i 0.80 --- 29.38. 1.74 -. _0.00 50 - ---50 50 -.. -B 39 -- - 162 86 .-- - 0 126 -- - 126 126 - ---11, 100 __ --309. 218 --- --Q ---- -- -- - - - --- ------ -- 8 c) AED excursion j 11 -29 Envelope lossrgain 301 178 684 482 12 a) Infiltration 87 30 166 56 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 388 208 850 769 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 119 94 357 283 14 Subtotal 507 302 1207 1052 15 Dudloads 110°/ 21%1 51 64 10% 21% 12-2 225 Total room load I I 1 558 366 1320 1277 Air required (dm) 0 17 0 60 Calculations al ogr.esofe- .4CA Rigfi-Suite®Univ rsal 201919.0.20 RSU18908 Coquina Ave1TBD Coquina Ave 1246 B RHG - W Cad Calc = MJ8 Frort Door faces: N 2020-Nov-09 11 38:1 0 Page 5 * wrightsoft' i Right-JO Worksheet House One Stop lCooling and Heating Job: 1246 RHG Date: 07/23/2020 By: LVL 7225 Sandscove Court, Wirier Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwKOneStopCooling.com License: CAGI817652 1 Room name FOY 2 Exposed wall 3.4 It 3 Room height 8.0 It heaU000l 4 5 Room dimensions Room area I 1.0 x 176.9 ft 176.9 ftz Ty Construction U-value Or I HTM Area (in) Load Area Load number (Btuh/itz-°F) I (BlJjhj2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y1 ! . G 12C-OsW _ '-4A5 2ov _-� - - - - 0.091 - - 0.320 n --n F 227 ---' 7.97 2.34 :r _. 8.60 - _ 0 _ - -0 - 0 .. 0 ' 0 ' 0 = - - 0 - - - -- - - - - -- V[�� 12C-Osw 0.091 a i 227 2.34 28 8 18 19 11 4A5-2ov 4A5-2ov 0.320 0.320 a a 1 7.97 7.97 22.64 22.64 0 0 0 0 0 0 0 0 --0'----- V)/ 11D0_ ^. 12C•Osw _ 0390. 0 091 __ e� " s 971 2 27 7.82 2.34 - 20 20 0 _ 195 0 157 -- 0 - - _ .�._ •`- _.. _ -- ___ I--( 4A5.2ov- --- - --- ..0320 : s-1 .---T97 _u- 8.80 V�✓ 12C-Osw 4A5-2ov 0.091 0.320 w w 2.27 7.97 2.34 22.64 0 0 0 0 0 0 0 0 --- R---227 11DO 0.390 w 9.71 11.99 1.44 0 _--..174 0 - -1� 0 ---__� 0 _.._..�M - - - - __.._..-_- -_ 0390n 9.71.. .7.82 . _ 18------ -18 _174 140--__ C 166-30ad ___-._.... 0.032 0.80 1.74 177 177 141 307 -_... F__.._ - - - . .22Acpm - -- = - -- - -.__. _.. _...__._ 1.180.: -- ---- _29.38 -----0.00- --177 ....___ =-3 _ ._ _- -100' - - -- -.__ -.- - --- --------. . 6 c) AED excursion -44 Envelope loss/gain 981 803 12 a) Infiltration 55 19 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 Subtotal (lines 6 to 13) t 1036 822 i Less external load 0 0 Lesstransfer 0 0 Redistribution -1036 -822 14 Subtotal 0 0 15 Duct loads 10% 21 % 0 0 Total room load 0 0 Air required (cfm) 0 0 wrYgFrrtsoTt� Right -Suite® Uriver.1201919.0.20 RSU18908 Coquina Ave\TBD Coquina Ave 1246 B RHG - W C.{ut Calc = MJ8 Frort Door faces: N 2020-Nov-091138:10 Page 6 - - wrightsoft. Duct System Summary Job: 1246 RHG Date: 07/23/2020 House By- LVL One Stop Cooling and Heating 7225 Sandsoove Curt, Winter Parr FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopGooling.com License: CAC1817652 Project• • For: Wade Jurney Homes Heating Cooling External static pressure 0 in H2O 0.50 in H2O Pressure losses , 0.16 in H2O 0.16 in H2O Available static pressure -0.2 in H2O 0.34 in H2O Supply/return available pressure 0.080/-0.080 in H2O 0.170/0.170 in H2O Lowest fri cti on rate -0.13 in/100ft 0.273 in/1OOft Actual air flow 0 clm 593 cfm Total effective length (TEL) 124 ft Supply Branch Detail Table Name Design (Btuh) Htg' (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA 2 c . 366 0 17 0.287 4.0 Ox 0 M Fx 18.3 100.0 st2 BED2 c 1277 0 60 0.292 6.0 Ox0 VI Fx 16.6 100.0 st2 BED3 c 2226 0 105 0.273 6.0 Ox 0 VIFx 24.5 100.0 st2 KIT c 2764 0 131 0.295 6.0 Ox0 VIFx 15.3 100.0 st1 Llv c 3053 0 144 0.302 7.0 Ox 0 VI Fx 12.7 100.0 st1 MBA c 353 0 17 0.293 4.0 Ox 0 VI Fx 15.9 100.0 st1 MBED c 2492 0 118 0.275 6.0 Ox 0 VIFx 18.5 105.0 st1 Trunk Htg i Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 0 410 0.275 522 12.0 0 x 0 VinIFIX st2 PeakAVF 0 183 0.273 685 7.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat[ Trunk rb1 Ox0 0 593 0 0 0 0 Ox 0 VIFx * wrightsoft`° 2020-Nov-091138:11 ..., .•, .., am� RigtVSUte®Uriver—I —9 19.0.20 RSU18908 Page 1 Cogdria Ave\TBD Coqure Ave 1246 B RHG - W C.iut Calc = MJ8 Frort Door faces: N Static Pressure and Friction Rate Job: 1246 RHG -�- wrightsoft, Date: 07/23/2020 House By: LvL One Stop Cooling and Heating 7225 Sandscove Coin, W ir4er Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCooling.com License: GAM 817652 For: External static pressure Pressurelosses Coil Heatexchanger Supply diffusers Return grilles Fi Iter Humidifier Balancing damper Other device Wade Jurney Homes Heating Cooling (in H2O) (in H2O) 0 0.50 0 0 0 0 0.03 0.03 0.03 0.03 0.10 0.10 0 0 0 0 0 0 Available static pressure -0.2 0.34 Total• supply Return (ft) (ft) Measured length of run -out 13 0 Measured length of trunk 11 0 Equivalent length of fittings 100 0 Total length Total effective length Supply Ducts Return Ducts 124 Heating (i n/100ft) -0.129 < 0.06 -0.129 < 0.06 Fitting Equivalent LengthDetails Supply 4X--35,11 A=20,11 G_-5,1 A=35,11 Gam: Total EL=100 Return TotalEL=0 0 124 Cooling (in/100ft) 0.273 > 0.18 0.273 >0.18 t Wrigt>tt�softN 2020-Nov-091138:11 �, •4•- s•� •,•-,n �, Rigfi-Sute®Uriversal201919.0.20RSU18908 Page ...Coquna Ave\TBD Coqure Ave 1246 B RHG - WC. ! rLI Calc = MJ8 From Door faces: N 4" Bath Duct to Roof W(Fan Broan 1688F 50 CFM 8x4 17 cfm Job #:1246 RHG Performed by LVL for: Wade Jumey Homes Level 1 MBED 10x6 18 cfm 24x4 I SRB 2 4 ^ 12 " MBA 8x4 17 cfm 24x14 RA 10x6 593 cfm 60 cfm LAUN BED2 6 FOY 7 " M 24x4 BA'2 4" SRB 1 1 Ox6 6 " 105 cfm 24 x 4 BED 3 i i UV tOx8 144 cfm Ix �7" GAR 131 cfm 10x6 Krr One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 www.OneStopCooling.com U MC-1:1.5 TQV 14.0 SEER H.P. AC SLAB BY BUILDER 2' FROM WALL 4" Dryer Duct to Cap w/Dryer Vent Box Scale:1 : 36 Page 1 Right -Suite® Universal 2019 19.020 RSU18908 2020-Nov-091129 00 CoquinaAve 1246 B RHG- WC.rut