Loading...
HomeMy WebLinkAboutAPPROVED PA FL10758-R8Business Professional e i • Regulation r l SCIS Homo lrg 7n i User Registration I Floc mpkz Su6mlt Surcharge stXs & Facts Publkatrons Conran us ! scis site map Emirs E search d,Nr ' PraducY Approval USER, Public User Product Apl;?pOVaI Menu n Emduct pr A20cation Search '� Agtllicatlon Lista Application Dew[ FL # FL10758-RS Application Type Revision Code Verslon 2a20 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Erna-it Authorized Signature Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Email Category Subrategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg-keeler@owenscorning.com Greg Keeler 9reg.keeler@owenscornirig.com Greg Keeler 2790 Columbus Road Granville, Olt 43023 (740) 321-6345 greg.keeIer@OWenscorning.com Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Zachary R. Priest PE-74021 PRI Construction Materials Technologles, LLC 12/31/2024 Steven M. Urich, PE -, Validation Checklist - Hardcopy Received FLI0758 R8 COI_DCR140O3.4 Z020 FBC Eval Vents finalf https_//www_floridabuilding_orgipr/pr_app_dtl.aspx?param=wGEVXQwtDgrrtdAvIteOYOf2hC3xFtrydggfPhgLACiVmFHfXgoD3ASJQ%3dJ3d page i of 3 Certified By Sections from the Code 1708.2 Product Approval Method Method 2 Option B Date Submitted 08JIG/2020 Date Val ldated 12/16/2020 Date Pending FBC Approval 09/18/2020 ❑ate Approved 12/17/2020 FL # Model, Numiser or Name 10758.1 VentSure 4-Foot Strip Heat and Moisture Rldge Vents Llmits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: NIA Design Pressure: N/A Other: Refer to evaluation report 10758.2 EVentSure Low Profile Slant Back f Roof Vent With Exterior Louver ._........... _ Limits of Use Approval for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: NIA Other: Refer to evaluation report. 10758.3 1 Ventsure Rigid Roll Ridge Vent Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report, Description Copolymer plastic low profile attic ridge vents for installation In shingle roof systems Installation Instructions FL10758 R8 II OCR14003.4 20 20 FBC Eval Vent firlalF Verified By: Zachary R, Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FLID758 R8 AE OCRiA .4 202 FBC val Vents final df Created by Independent Third Party: Yes Galvanlzed metal roof vent Installation Instructions FL10 _U R6 LZ_ Qr.R 14QO3.4 2 120 FSC -val V n s E _pdf Verified By. Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports )�L107513_R9 AF—4 2 FBC Evall Vents f _per Created by Independent Third Party. Yes Ridge Ventilation System Installation Instructions LE 1075_R8 11—C)CR141003.4 2 2Q F C Ev I V fin . df Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports EL10758 R8&E_0 R4003.4 2024. FBC oval Van c [ina! :per Created by Independent Third Party: Yes back hIr_rt C4nlad Lis 2501B121 Stone 003 i,.7a4ahassoatL 373ao Phnne: asa aa7_in1.r The State of Florida is an AA�l employer. Cap%"; }t},007-2D13 smt1nr r-i��,na . - Pr, n := Scesslhdlty Sratemenr :: Refund to nt under Fle ride law, email addresses are public records. If you do not want your e-rrieil address released in response to a pub l ic-reoords request, do not send electronic maR to this entity, Instead, contact the office by phone or by traditional mall. if you have any questions, please rontart 850.487.1395- "'Pursuant to Section 455.275(I), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have One. The emalls provided may be used For offECiai communication with the Ilceril Now over email addresses are public record If you do not wish to supply a personal address, please provide the Department with an email address which can be made ava ill We to the pub ltc. To determine if you are a licensee under Chapter 455, F S-, pfea se click here . Product Approval Accepts: M �::] 'G—iii F] https_l/www.flortdahullding.org/prIpr_app_dtl.aspx?param=wGEVXQwtD4vIdAviteOYOl2hC32Ptrydg9fPhgLACiVmrHfXgoa3A5JQ ,3d13d Page 2 of 3 Cfedit cni d Safe https_//www_floridabullding.❑rg/pr/pr_app_dd-aspOparam=wGEVXQwtDgvfdAviteOYC%2hC3zFtrydggfPhgLACiVmFHfXgoD3A5JQ%3d%3d Page 3 of 3 � • CREEK Certificate pf Authorization No. 29824 (r 17520 Edinburgh Dr ... Tampa, FL 33647 TECHNICAL SERVICES, LLC (913) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7" EDITION (2020) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15. 2020 1 Owens Corning Parkway Toledo, OH 43657 (800) 438-7465 www.a,venscornin ,gM Quality Assurance: PRI Construction Materials Technologies (QUIA9110) $CaAE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708.2 Properties: Roof Ventilation REFERENCES ErAL Report No. Standard Year Architectural Testing, Inc (TST1558) 01 38660.04 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) 01-38660-05 TAS 100(A) 1995 Archltectural Testing, Inc (TST1558) C1774.01-109-18 TAS 10C(A) 1995 ASTM D 635 2014 ASTM D 1929 2016 PRI Construction Materials Technologies (TST5878) AVIG-005-02-01 ASTM D 2843 ASTM D 635 2016 2014 ASTM D 1929 2016 PRI Construction Materials Technologies (TST5878) AVIG-006-02-01 ASTM D 2843 ASTM G 155 2016 2013 PRI Construction Materials Technologies (TST5878) OCF-111-02-01 ASTM D 635 2014 ASTM D 1929 2016 PRI Construction Materials Technologies (TST5878) OCF-112-02-01 ASTM D 2843 ASTM G 155 2016 2013 PRI Construction Materials Technologies (ST5878) OCF-116-02-09 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OCF-223-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OHI-007-02-01 TAS 100(A) 1995 OCR14003.4 FL10758-R8 Pa e 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not f a CREEK TECHNICAL SERVICES, LLC PRODUCT 1)ESCRIPTION AND APPLICATION GWENS CORNING VentSureO Roof Ventilation VentSure" 4-Foot Strip 1-114" x 14-718" x 48" low -profile attic ridge vent consisting of a two -layer nylon - Heat and Moisture Ridge polyester composite- Available vwith or without a polyester fabric moisture barrier for Vents: installation in shingle roof systems. irI!i i 77L6�!1PJp�uak ■Itl llflr]! 1. ++ iva;i`a.. ;: ::�� tla+ ll rlllr lr If 1! i � Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBG requirements Roof slope: Minimum 3:12 to maximum 16112 Installation Height- Maximum 60-ft Attachment Method: Cut a 2-Inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 6-inches from the rake edges. Apply a %-inch wide bead of ASTM D 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga. 2'/-inch galvanized ring shank nails (shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 11 ga. 2'/2-inch galvanized ring shank roofing nails (shall comply with FBC Section 1506.5) provided with the vent or as directed by the shingle manufacturer's installation instructions. Allowable Roof Coverings: Asphalt shingles OCR14003.4 FL10758-RS Pa e 2 of 5 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid This evaluation report does not express nor mply warranty, installation, recommended use, or other product attributes that are not a� CREED owEnls coRNlrvc TECHNICAL SERVICES, t,LC VentSuree Roof Ventilation VentSureW'3 Low Profile 18' x 24' x 2-3116" (32" x 23" flange base) static off -ridge vent composed of ASTM Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with with Exterior Louver: FRG Section 1507.4.3. �' jZg Dock Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction- Roof deck shall be designed and installed in accordance with FBC requirements_ Roof slope- Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 114-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Race vent directly over the hole, ensuring the vent sits flat on the roof_ Fasten vent 4-inches a.c. and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per vent). Install baffle in %-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles OCR14003.4 FL1 D758 R8 This evaluation repun is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREEK Technical Services, LLC of any product Changes or quality assurance changes throughout the duration for which this report is valid This evaluatlon report does not express nor imply warranty, installation, recommended use, or other product attributes that are not CREEKGWENS CORNING i..�',u'M VentsuraS Roof Ventilation .,:i TECHNICAL SERVICES, LLC VentSureo Rigid Roll 518' x 11-1/4" x 20' attic ridge vent composed of high density polypropylene with a Ridge Vent: spun -bond polypropylene fabric - Deck Type. Roof deck shall he constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope. Minimum 2:12 to maximum 20:12 Instaliation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o,c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5). ensuring %-inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line' with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed by the shingle manufacturer's installation instructions, ensuring 1/4-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles LwTATioms 1) This report is not for use in the HVHZ. 2) Fire Classification is outside the scope of this evaluation - 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturers published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCR14003.4 FL10758-RB Page a of 5 This evaluation report is provided for Stata of Florfda product approval under Rule 61G20-3. The manufacturer shall notify CREEK TeChnical Services, LLC of any product changes or quality assurance changes Ihrougheut the duration for which this report is valid. This evaluatlon report does not express nor imply warranty, installation, recommended use, or other product attributes that are not � CREEK ....<' TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT OWENS CORNING VentSure(D Roof Ventilation 'rho products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 71h Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. •;1'�"1e� rill p frf'� �i Z 1! No 74021 STATE OF �D CERTIFICATION OF INDEPENDENCE 2020.12.15 1 3:59:34 —V5'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services. LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ❑CR14003.4 FL10758-R8 Pa e 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3 The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid_ This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not �..o.•iFr oll, nr(rirac oc.-! L.oroin