Loading...
HomeMy WebLinkAbout702 ANITA STREET, FORT PIERCE, FL. 34982 PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 04/06/2021 Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Residential X PERMIT APPLICATION FOR:WATER HEATER REPLACEMENT PROPOSED IMPROVEMENT LOCATION: LIKE KIND Address: 702 ANITA STREET, FORT PIERCE, FL 34982 Property Tax ID #. 3403-331-0002-000-7 Lot No. Site Plan Name: 3 36 40 FROM NW COR HUNTS S/D RUN N 330 FT, TH E 940 FT FOR POB, Block No. Project Name: TH CONT E 120 FT, TH S 170 FT, TH W 120 FT, TH N 170 FT TO POB (29-B) (0.47 AC) DETAILED DESCRIPTION OF WORK: REPLACE LIKE KIND 30 GALLON WATER HEATER UNDER SINK IN COTTAGE New Electrical Meter Second Electrical Meter CONSTRUCTION INFORMATION: Additional work to be performed under this permit —check all that apply: Mechanical Gas Tank _ Gas Piping — Shutters Electric 1 Plumbing Total Sq. Ft of Construction: Cost of Construction: $ 2,134.85 OWNERAESSEE: NameJAMES OR DORIS STAPLETON ❑rlrlracc•702 ANITA STREET City: FORT PIERCE Sprinklers _ Generator Zip Code: 34982 Fax: NIA Phone No.561-310-2933 F-Maii.CRAZY4THEPUPPIES@GMAIL.COM Sq. Ft. of First Floor: Windows/Doors J Pond Roof Pitch Utilities: —Sewer —Septic Building Height: state: P L Fill in fee simple Title Holder on next page ( if different from the Owner listed above) CONTRACTOR: N.mP- MATT BLACK Company:BENJAMIN FRANKLIN PLUMBING Address:6945 NW LTC PARKWAY City: PORT SAINT LUCIE State: FL Zip Code: 34986 Fax: 772-871-9069 Ph,,, Nn772-871-9494 E-Mail PERMITS@BENFRANKLINPLUMBER.COM State or County LicenseCFC-1430437 If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: 1. NGINEER: x Not Appli Name: Address: Citv: Zip: Phone FEE SIMPLE TITLE HOLDER: Name: Address: Citv: Zip: Phone:_ State X Not Applicable MORTGAGE COMPANY: Name: Address: Citv: Zip: Phone:. X Not Applicable State: BONDING COMPANY: X Not Applicable Name:_ Address: City:_ Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, wails, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property: A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on thejobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording our Notice of Commencement. kfh-� signature of Owner/ Lessee/Contractor as Agent for Owner re of Contractor/License STATE OF FLORIDA STATE OF FLORIDA . COUNTY OF COUNTY OF L Sw9Fn to (or affirmed) and subscribed before me of P_bysical Presence or Online Notarization this day of ! 202� by Name of person making statement. Personally Known OR Produced Identification Type of Identification Produced D o REVIEWS DATE RECEIVED DATE COMPLETED JULIE JAME MCCAULEY Notary Public - State of F J Commissioak HH 499 eard l' My Comm. Expires Oct 1, 2024 FRONT I ZONING COUNTER REVIEW Swain to (or affirmed) and subscribed before me of Physical Presence or online Notarization this ]�j day of &L) j 202V by Name of person making statement. Personally Known -/ Type of Identification Produced OR Produced Identification (Signatu(h 10 JULIE JANE MCCA:;.*.v Commissio Notary Public • State o' q.�I m ion # HH 49824 My Comm. Expires Oct +, 2024 SUPERVISOR PLANS VEGETATION SEA TURT REVIEW REVIEW REVIEW REVIEW IANGROVE REVIEW Residential Electric Water Professional Classic Water Heaters 11 The new degree of comfort' Professional Classic® electric water heaters are engineered for longer life - resistored heating elements and premium grade anode rod Efficiency •.90-.93LIEF • Isolated tank design reduces conductive heat loss • Resistored copper upper element and resistored Lifeguard'" stainless steel lower element to prolong anode rod and tank life T� Performance • FHR: 45 - 67 gallons, based on gallon capacity • Recovery: 21 GPH at a 90' F rise System Sentinel (Available on selected models) • Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs pin point the exact location of functioning or non- functioning heating elements Longer Life • Premium grade anode rod provides long-lasting tank protection Features • Electric junction box located above heating elements for easy installation ■ Over -temperature protector cuts off power in excess temperature situations • Automatic thermostat keeps water at desired temperature Plus... • RheemglasO tank lining resists corrosion and prolongs tank life • EverKleen® self cleaning device fights harmful sediment build-up with a high -velocity spiraling water stream — helps operating efficiency by saving energy, money and improving tank life • Enhanced -flow brass drain valve • Temperature and pressure relief valve included • Models are compliant to HUD Standards for manufactured housing and modular construction • Low lead compliant Warranty • 6-Year limited tank and parts warranty" • With ProtectionPlus'" the 6-year limited tank warranty becomes 10-year `See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to the AHRI Operations Manual and D.O.E. proceclures. Units meet or exceed the energy efficiency requirements of NAECA, ASHPAE standard 90, ICC Code and all state energy efficiency performance criteria. Professional Classic 19.9 to 55-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models Electric See specifications chart on back, PRrNTED IN U.S.A. 07120 WP FORM NO. PROF AH N Rev. 10 a The new degree of ca rfwr Professional Classic® Specifications Residential Electric water Professional Classic Water Heaters DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES[ ENERGY INFO. T Y P E NOMNAL GALLON CAPACITY RATER GALLON CAPACITY MODEL NUMBER OEF FIRST HOLM RATING G.P.H. RECOVERY IN G.P.H. 90' F RISE TANK HEIGHT A HELGHTTG WATER CONK. a DIAMETER O APPROX. SHIP wT. tLBs4 UNIFORM ENERGY FACTOR ILIEFI Tall 30 27 PROM T2RH95t 40 21 47-1/2 50-3/a 19 92 0.92 Taw 40 35 PROE40 T2 RH951 55 21 80-3/4 63-5/8 19-1/4 109 0.93 Tall 50 45 PROM T2RF1951 63 21 58-5/8 81-wo 1 20-1/4 121 0.93 Tall 55 55 PROE56 T2 RF194' 72 21 57 59-3/4 22-1/4 128 0.92 Med. 30 27 PROE30 M2 RH95' 45 21 37-1/2 40-1/2 20-1/4 92 0,90 Med, 40 36 PROE4D M2 RH95t 55 21 48-1/4 50-1/2 20-1/4 106 0.93 Med, 50 45 PROE50 Ad2 RI-195t 62 21 48 50-1/2 23 132 0.93 Short 19.9 - PROM $2 RH - 21 31-1/2 31-1/2 17 62 - Short 28 25 PROF28 S2 AH95 45 21 30 31-1/8 23 95 1 0.92 Short 30 27 PROE30 S2 RH95 B" 1 46 1 21 1 30-1/8 1 32 19-3/4 95 0.92 Short 36 33 PROE36 S2 RH95 46 21 31-1/2 33 24-1/4 118 0.92 Shod 3B 35 MOE38 S2 RH95 B- 51 21 31-1/2 32-5/6 23 108 0.92 Short 47 43 PROE47 82 RH95 54 21 32 34 26-1/4 149 0.93 Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) remdrements. t System Sentinel optional. Add ECi to the end of the model number. System Sentinel not available on single element models, available on dual element models only. System Sentinel not available In excess of 5 kW on 208 V models. " Insulation blanket recpAred to adh eie UFF val.ie. water .heater d nansions prior to raa" Insulation hlanKel. Blanket is included with water heater. • Heaters furnished with standard 240 volt AC, single phase non-siTAdlaneous wring, and 4500 watt upper and lower heating elements. • If heating elements of different wattages than those shown are demanded by zone ro"kements, they must be spe*Mcady requested • S ngle eio nrnt models ava Wk on special order (6WM max.). Substitute °1 ` for '2' 'n ROM number. • Some] Wiring Options - A knited rumber of special wrIV otJW are available. Consult factory tof DrM and availsAly. r A.w models eu ipped with treat traps. Recovery = wattage/2,42 x temp. rise *F. Example: 450OW = 21 GPH 2.42 x 90° Recovery cakwlatiors used are based or 4500 watt eiernents used in non-Slrrx WI6OUS operation. HOT g WATER COLD CONNECTION WATER RELIEF VALVE CONNECT[ CONNECTION Moor ROD DIAMETER A B WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 a www.rheem.com PRINTED IN U.S.A. 07/20 wP FOHM NO. PROF RH N Rev 10