Loading...
HomeMy WebLinkAboutEnergy Code`FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building PerformanCe Method A Project Name: 27598 - Model (1310) - Eastside Builder1 Eastside Builders Address: Lot: 359, Sub: , Plat: Permitting Office: City, State: Sebastian, FL Permit dumber: Owner: Himes Residence Jurisdiction Number: Climate Zone: Central { 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit Cap: 30.0 kBtu/hr 3. Number of units, if multi -family 1 _ I SEER: 12.00 4. Number of Bedrooms 2 _ b. N/A 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 1310 ftz c. N/A r 7. Glass area & type Single Pane Double Pane _ - a. Clear glass, default U-factor 0.0 ft2 0.0 ft2 _ 13. Heati sys b. Default tint 0.0 ft2 225.1 ftz _ a. Electri ea Cap: 27.0 kBtu/hr c. Labeled U or SHGC 0.0 ft2 0.0 ft2 HSPF: 6.80 8. Floor types _ b. N/A a. Raised Wood, Stem Wall ft2 _ b. N/A _ c. N/A _ c. N/A _ 9. Wall types _ 14. Hot water systems a. Concrete, Int Insul, Exterior R=4.1, 901.0 ft2 _ a. Electric Resistance Cap: 40.0 gallons b. Frame, Wood, Exterior R=19.0, 80.0 ft2 _ EF: 0.90 _ c. N/A _ b. N/A _ d. N/A e. N/A c. Conservation credits 10. Ceiling types _ (HR-Heat recovery, Solar a. Under Attic R=30.0, 1370.0 ft2 _ DHP-Dedicated Beat pump) b. N/A _ 15. HVAC credits PT, c. N/A (CF-Ceiling fan, CV -Cross ventilation, 11. Ducts _ HF-Whole house fan, a. Sup: Unc. Ret: Unc. AH: Attic Sup. R=6.0, 225.0 ft _ PT -Programmable Thermostat, b. N/A MZ-C-Multizonecooling, MZ-H-Multizone heating) Glass/Floor Area: 0.17 Total as -built points: 19987 PASS Total base points: 20044 I hereby certify that the by this calculation ar Energy Code. PREPARED DATE: D I hereby ce ' y tha his compliance with the Flc OWNER/AGENT- _ DATE: lans and pecifications covered pli e rida com building, as designed, is in Review of the plIns and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING O�FICIAL: DATE: FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: 359, Sub:, Plat:, Sebastian, FL, j PERMIT #: BASE AS -BUILT FGLASSPES ditioned X BSPM = Points IF Floor Area Type/SC O, e; A a P1 Points .18 1310.0 25.78 6078.9 Double, Tint q TAT_ 7' 4$. `5+ .. Y9 [d.99 689.4 Double, Tint E 1.0 8.5 23.2 45.16 0.99 1040.5 Double, Tint NE 1.0 7.3 16.2 32.90 0.99 526.2 Double, Tint N 1.0 4.7 10.7 20.63 0.96 211.0 Double, Tint N 1.0 4.5 26.6 20.63 0.95 522.5 Double, Tint N 1.0 6.3 23.2 20.63 0.98 468.5 Double, Tint W 3.3 6.7 46.4 40.60 0.74 1391.5 Double, Tint S 1.0 6.3 46.4 33.69 0.95 1492.3 Double, Tint S 1.0 5.7 16.2 33.69 0.94 512.1 As -Built Total: 225.1 6854.0 WALL TYPES Area X BSPM = Points Type I R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 4.1 901.0 1.18 1063.2 Exterior 981.0 1.90 1863.9 Frame, Wood, Exterior 19.0 80.0 1.00 80.0 Base Total: 981.0 1863.9 As -Built Total: 981.0 1143.2 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 40.0 7.20 288.0 Exterior 40.0 4.80 192.0 Base Total: 40.0 192.0 As -Built Total: 40.0 288.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1310.0 2.13 2790.3 Under Attic 30.0 1370.0 2.13 X 1.00 2918.1 Base Total: 1310.0 2790.3 As -Built Total: 1370.0 2918.1 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 0.0(p) 0.0 0.0 Raised Wood, Stem Wall 0.0 166.0 -5.80 -962.8 Raised 166.0 -3.43 -569.4 Base Total: -569.4 As -Built Total: 166.0 -962.8 INFILTRATION Area X BSPM = Points Area X SPM = Points 1310.0 14.31 18746.1 1310.0 14.31 18746.1 EnergyGauge® DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details i ADDRESS: Lot: 359, Sub:, Plat:, Sebastian, FL, PERMIT #: i BASE AS -BUILT Summer Base Points: 29101.8 Summer As -Built Points:i 28986.6 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSMI x AHU) 28986.6 1.000 (1.087 x 1.150 x 1.10) 0.284 0.950 10760.0 29101.8 0.4266 12414.8 28986.6 1.00 1.375 0.284 0.950 10760.0 EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCPB v3.30 i � I FORM 60OA-2001 - WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: 359, Sub:, Plat:, Sebastian, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1310.0 5.86 1381.8 Double, Tint SE 1.0 7.3 16.2 8.18 1.01 134.3 Double, Tint E 1.08.5 23.2 9.46 1.00 220.5 Double, Tint NE 1.0; 7.3 16.2 11.04 1.00 178.9 Double, Tint N 1.0 4.7 10.7 11.29 1.00 120.4 Double, Tint N 1.01 4.5 26.6 11.29 1.00 299.3 Double, Tint N 1.0 6.3 23.2 11.29 1.00 261.3 Double, Tint W 3.3 6.7 46.4 10.07 1.04 487.5 Double, Tint S 1.0 6.3 46.4 7.70 1.00 359.2 Double, Tint S 1.0 5.7, 16.2 7.70 1.01 126.1 As -Built Total: 225.1 2187.4 WALL TYPES Area X BWPM = Points Type I R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Concrete, Int Insul, Exterior 4.1 901.0 3.31 2977.8 Exterior 981.0 2.00 1962.0 Frame, Wood, Exterior 19.0 80.0 1.10 88.0 Base Total: 981.0 1962.0 As -Built Total: 981.0 3065.8 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 40.0 7.60 304.0 Exterior 40.0 5.10 204.0 Base Total: 40.0 204.0 As -Built Total: 40.0 304.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1310.0 0.64 838.4 Under Attic 30.0 1370.0 0.64 X 1.00 876.8 Base Total: 1310.0 838.4 As -Built Total: 1370.0 876.8 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 0.0(p) 0.0 0.0 Raised Wood, Stem Wall 0.0 166.0 1.80 298.8 Raised 166.0 -0.20 -33.2 Base Total: -33.2 As -Built Total: 166.0 298.8 INFILTRATION Area X BWPM = Points Area X WPM = Points 1310.0 -0.28 -366.8 1310.0 -0.28 -366.8 i EnergyGauge® DCA Form 60OA-2001 EnergyGaugeO/FlaRES'2001 FLRCPB v3.30 e � FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: 359, Sub:, Plat:, Sebastian, FL, j PERMIT #: BASE AS -BUILT Winter Base Points: 3986.2 Winter As -Built Points: 6366.0 Total Winter X System = Heating Total X Cap X Ducts X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 6366.0 1.000 (1.078 x 1.160 x 1.11) 0.502 0.950 4213.2 3986.2 0.6274 2500.9 1 6366.0 1.00 1.388 0.502 0.950 4213.2 EnergyGaugeTm DCA Form 600A-2001 EnergyGauge®/FIaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: Lot: 359, Sub:, Plat:, Sebastian, FL, ! PERMIT #: BASE I AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2564.00 5128.0 40.0 0.90 2 1.00 2507.02 1.00 5014.0 As -Built Total: 5014.0 CODE COMPLIANCE STATUS BASE AS -BUILT i Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 12415 2501 5128 20044 10760 4213 5014 19987 PASS 1� EnergyGauge'rm DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCPB v3.30 TORM 60OA-2001 - - Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: Lot: 359, Sub:, Plat:, Sebastian, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the to late. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous linfiltration barrier is installed that is sealed i to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. RA-22 nT14FR PRFSCRIPTIVF MFA-RURFS (must he mpt or PyepAded by all residences-1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6712. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeT" DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SC The higher the score, the more efficient the hl 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Glass area & type a. Clear - single pane b. Clear -double pane c. Tintlother SHGC - single pane d. Tint/other SHGC - double pane 8. Floor types a. Raised Wood, Stem Wall b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Frame, Wood, Exterior c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Attic b. N/A i Himes Residence, Lot: 359, Sub:, Plat:, Sebastian, FL, New Single family _ 1 2 _ No 1310 ftz Single Pane Double Pane 0.0 ftz 0.0 ftz 0.0 ftz 225.1 ftz 0.0 ftz 0.0 ftz R=0.0, 166.0ft2 _ 12. Cooling systems a. Central U b. N/A c. N/A ' 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems I _ a. Electric Resistance R=4.1, 901.0 ftz _ I R=19.0, 80.0 ftz _ b. N/A Cap: 27.0 kBtu/hr HSPF: 6.80 Cap: 40.0 gallons EF: 0.90 _ c. Conservation credits _ (HR-Heat recovery, Solar DHP-Dedicated heat pump) R=30.0, 1370.0 ftz _ 15. HVAC credits PT, (CF-Ceiling fan, CU-Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, Sup. R=6.0, 225.0 ft _ MZ-C-Multizone cooling, Mg-H-Multizone heating) i I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EP Display Card will be completed based on installed Code co pliant fea es. Builder Signature: Date: (p C3 i Address of New Home: City/FL Zip: *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not, a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPAIDOE EnergyStarTMdesignation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a! Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Effici r.ency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCPB v3.30) BUILDING INPUT SUMMARY REPORT Title: 27598 - Model (1310) - Easts Family Type: Single %address Type: Lot Information H Owner: Himes Residence New/Existing: New Lot #: 359 W# n of Units: 1 Builder Name: Eastside Builders Bedrooms: Conditioned Area: 2 Subdivision: 1310 Platbook: (blank) (blank) 0 a Climate: Central Permit Office: (blank) Total Stories: Worst Case: 1 Street: No County: N/A (blank) Jurisdiction #: (blank) Rotate Angle: (blank) City, St, Zip: Sebastian, FL, U) 0 0 LL # Floor Type R-Val Area/Perimeter Units N O # Door Type j Orientation Area Units 1 Raised Wood/Stem Wall 0.0 166.0ft' 1 1 Wood Exterior 20.0 ft2 2 N (' # Ceiling Type R-Val Area Base Area Units 0 Z # System Type j Efficiency Capacity 1 Under Attic 30.0 1370.0 ft2 1310.0 ft2 1 1 Central Unit SEER: 12.00 30.0 kBtu/hr Z J J Q V V Credit Multipliers: None Credit Multipliers: PT N .J J Q # Wall Type Location R-Val Area Units # System Type Efficiency Capacity 1 Concrete Block - Int Insul Exterior 4.1 901.0 ft2 1 2 Frame - Wood Exterior 19.0 80.0 ft2 1 Z Q LU 1 Electric Heat Pump HSPF: 6.80 27.0 kBtu/hr = Credit Multipliers: IPT y Return Air Handler Location Location Supply Supply R-Val Lengths # 1 Panes Tint Ornt Double Tint SE Area OH 16.2 ft2 Length OH Hght Union 1.0 ft 7.3 ft 1d. Uncond. Attic 6.0 225.0 ft 2 Double Tint E 23.2 ft2 1.0 ft 8.5 ft 13 Double Tint NE 16.2 ft2 1.0 ft 7.3 ft 14 Double Tint N 10.7 ft2 1.0 ft 4.7 ft 15 None FW Double Tint N 26.6 ft2 1.0 ft 4.5 ft 1ltipliers:' 6 Double Tint N 23.2 ft2 1.0 ft 6.3 ft 1 Type EF Cap. Conservation Type Con.EF 7 8 Double Tint W Double Tint S 23.2 ft2 23.2 ft2 3.3 ft 6.7 ft 2m 1.0 ft 6.3 ft 2c Resistance 0.90 40.0 None 0.00 9 Double Tint S 16.2 ft2 1.0 ft 5.7 ft 1 (n # Use Default? Annual Operating Cost Electric Rate 3: 1 Yes N/A N/A 0 LL p Z_ UJI Rater Name: CodeOnlyPro Class #: 3 Pool Size: 0 V Rater Certification #: CodeOnlyPro Duct Leakage Type: N/A Pump Size: 0.00 hp iJ) Area Under Fluorescent: 0.0 Visible Duct Disconnects: N/A Dryer Type: Electric Area Under Incandescent: 1310.0 Leak Free Duct System Proposed: No Stove Type: Electric NOTE: Not all Rating info shown HRV/ERV System Present?: No Avg Ceil Hgt: tnergyuaugew (version: I-LMI:I-'ti v3.sU)' Himes Residence Sebastian, FL Summary Energy Code Results Residential Whole Building Performance Method A Project Title: ! Code Only 27598 - Model (1310) - Eastside Professional Version Climate: Central 5/4/2005 Building Loads I Base As -Built Summer: 29102 points Summer: 28987 points Winter: 3986 points Winter: 6366 points Hot Water: 4513 points Hot Water:. 4513 points Total: 37601 points Total: 39865 points Energy Use Base As -Built Cooling: 12415 points Cooling: 10760 points Heating: 2501 points Heating: 4213 points Hot Water: 5128 points Hot Water:; 5014 points Total: 20044 points Total: 19987 points PASS e-Ratio: 1.00 EnergyGauge®(Version: FLRCPB v3.30)